Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Similar documents
Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

IMPLEMENTATION OF DISPLACEMENT VENTILATION SYSTEM BY USING A WALL-MOUNTED AIR CONDITIONER

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

How to ensure Thermal Comfort in buildings with CFD

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Comfort and health-indoor air quality

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Experimental study of space cooling using ceiling panels equipped with capillary mats

Yan Xue 1 and Qingyan Chen 2,1* Abstract

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Space Air Diffusion II

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Heat transfer and heating rate of food stuffs in commercial shop ovens

Basic CFD model of heat pipe

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

AR/IA/UP 241 Lecture 5: Psychrometrics

New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow

CHAPTER 2 LITERATURE REVIEW

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

Considerations in the Design of Smoke Management Systems for Atriums

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Compression of Fins pipe and simple Heat pipe Using CFD

Experimental Investigation of Tube Configuration for a Surface Condenser

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol

Displacement Ventilation

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

NUMERICAL SIMULATION OF THE HEAT LEAKAGE AT THE GASKET REGION OF DOMESTIC REFRIGERATORS

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

A study of radiant cooling for a room with daytime application in tropical climate

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

A Study of Drying Uniformity in a New Design of Tray Dryer

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Leakage of Mildly Flammable Refrigerants into a Room

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

,Chaojian He6, f. School of Guangxi University, Nanning , China.

American Society of Heating, Refrigerating and Air-Conditioning Engineers

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

DYNAMIC THERMAL MODELING OF A RADIANT PANELS SYSTEM AND ITS ENVIRONMENT FOR COMMISSIONING: APPLICATION TO CASE STUDY

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Residential ventilation concepts based on the idea of displacement airflow distribution

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Virtual Household Refrigerators at Steady-State and Transient Conditions. Numerical Model and Experimental Validation.

Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Heat Transfer in Evacuated Tubular Solar Collectors

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Drying principles and general considerations

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Experimental Verification of Cooling Load Calculations for Spaces with Non-Uniform Temperature Radiant Surfaces

Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Transcription:

INDOOR CLIMATE DESIGN BASED ON FEEDBACK CONTROL OF HVAC COUPLED SIMULATION OF CONVECTON, RADIATION, AND HVAC CONTROL FOR ATTAINING GIVEN OPERATIVE TEMPERATURE Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan ABSTRACT In this paper, a new CFD (Computational Fluid Dynamics) simulation method, coupled with a radiative heat transfer simulation and HVAC (Heating, Ventilating, and Air-Conditioning) control is presented. This new method can be used to assess the heating and cooling loads of different HVAC systems under the condition of same human thermal sensation (e.g. same operative temperature, etc.). To examine the performance of the new method, the thermal environment of the summer season within a semienclosed space which opens into an atrium space is analyzed under the steady-state condition. The most energy efficient HVAC system under the same thermal sensation can be chosen by using this method. The radiation-panel cooling system with air-curtain is found to be the most energy-efficient for cooling the semi-enclosed space in this study. INTRODUCTION CFD technique is used to analyze indoor thermal environments. CFD simulations (for summer season) until now have been conducted with given cooling loads in a room (Fig. 1 (a)). Since it is difficult to take into account the effects of velocity and temperature distributions in the room in advance, the B.C.s (Boundary Conditions) related to cooling load in the conventional simulation system are fixed as shown in Fig. 1 (a) and the indoor climate of the given B.C.s is analyzed. HVAC systems are, however, controlled based on temperature management of room air and the indoor climate of a targeted condition of the HVAC is obtained. Different types of HVAC system produce different thermal environments such as different vertical temperature distributions, different radiative fields, etc. Differences of thermal environment produce significant effects on the cooling loads and the indoor climate itself. In this context, CFD simulation should be able to address these problems, i.e., allow modification of the cooling load in the simulation procedure. Thus, a new simulation method that can feed back the output of the CFD to the input conditions for controlling the HVAC system is proposed as shown in Fig. 1 (b) and Fig. 2. Here the indoor climate of the targeted condition of the HVAC is obtained. This system is called here a new design method for HVAC systems with feedback [1]. This paper presents the new CFD method which is coupled with a radiative heat transfer simulation and HVAC control. This new method can provide information for modifying cooling loads which precisely INPUT (B.C.) shape of room, cooling load, types of HVAC system, etc. Indoor Thermal Environment Analysis by CFD OUTPUT velocity, tem perature, and humidity distribution, etc. (a) Conventional indoor climate simulation with B.C. of fixed cooling load INPUT (B.C.) shape of room, cooling load, types of HVAC system, etc. Indoor Thermal Environment Analysis by CFD OUTPUT velocity, tem perature, and humidity distribution, etc. modifing B.C. responding to OUTPUT Feedback system for HVAC control Feedback system is stopped when OT reaches the target value (b) New method; Indoor climate analysis with B.C. of feedback cooling load Fig. 1 Concept of Indoor Climate Simulation with/without Feedback System for HVAC Control (B.C. : Boundary Condition, OT: Operative Temperature) 1

1. CFD LOOP 2 OUTPUTS: velocity, temperature, and humidity distribution INPUT 2 (B.C.): modification of temperature & velocity B.C. regarding HVAC control IN PU T 1 (B.C.) : modification of temperature B.C. regarding the radiation calculation LOOP 1 wall temperature (T s ) convective heat transfer (q c ) FEEDBACK 1: with radiative heat transfer simulation FEEDBACK 2: with HVAC control 2. Radiation radiative heat transfer (q r ) radiative 3. Heat Balance of W all heat transfer (q r ) calculate q c using heat balance of wall (q s +q c +q r +q cd =0) q cd : conductive heat transfer through wall q s : total heat component at wall 4. Calculate OT Evaluate the therm al sensation of H um an Model operative 5. System Control temperature (OT n ) calculate new HVAC cooling load (q p,n+1 ) q p,n+1 =q p,n +C(OT n -OT n+1 ) OT n+1 = (T arget V alue) C : empirical constant (0.2-10.0) LOOP 1: conventional coupled sim ulation of convection, radiation, and humidity transport LOOP 2: newly developed part composed of HVAC system control Fig. 2 Procedure of Simulation including HVAC System Control take into account the temperature distribution, etc., and also the resultant indoor climate. In the simulation, HVAC outputs (e.g., inflow air temperature, inflow air volume, etc.) are modified by changing the input B.C.s using a feedback system of HVAC control as shown in Fig. 1 (b) and Fig. 2. These modifications are determined based on the simulations with the modified input B.C.s to keep the operative temperature of a human model at the target temperature (Fig. 1 (b), Fig. 2) [note 1]. To examine the performance of the new CFD method, the thermal environment of a semi-enclosed space (Fig. 3), which opens into an atrium space, is analyzed under the steady-state condition. In the study, the cooling condition in summer is analyzed. The atrium space is not fully air-conditioned, and its thermal environment is not the same as that of the semi-enclosed space. The opening between them causes the heat exchange between the two by air circulation and radiation. It is clear that both convective and radiative heat exchanges affect the cooling load of the semi-enclosed space. To predict the cooling load precisely, the amount of these exchanges must be accurately estimated. In this paper, two types of HVAC system are compared: one is a radiationpanel cooling system and the other is an all-air cooling system. Using the new CFD simulation with feedback system, the required cooling loads for attaining the same thermal sensation are quantitatively estimated and compared. The effects of an air-curtain at the entrance opening are also studied. COUPLED SIMULATION OF CONVECTION, RADIATION, AND HVAC CONTROL A feedback system, which returns the information of HVAC control, is added to the conventional coupled simulation of convection and radiation as shown in Fig. 2. In the procedure of the simulation, the feedback system modifies the B.C.s of CFD. In the usual HVAC system in a room, the air temperature at a specific point (e.g. exhaust outlets) is selected as the control target. However, it would be more rational for HVAC control systems to modify the HVAC outputs based on the thermal sensation of the occupants. In this paper, the thermal sensation of an occupant is evaluated based on his operative temperature (OT). The HVAC outputs are thus modified to keep the OT at the target temperature (). CFD Simulation Indoor flow and temperature fields are calculated based on 3D CFD simulation, using the standard k-ε model. In the radiation analysis, the view factor is calculated by the Monte Carlo method [8] and the radiation heat transfer between the walls by Gebhart s absorption factor method [9]. Humidity distribution in the room is given by solving the humidity transport equation based on CFD. The authors have already confirmed by comparing the predicted results of room air flow and wall temperature with experimental results that the CFD coupled with the radiative heat transfer simulation is a sufficiently reliable tool for analyzing indoor thermal environments [5]. HVAC Control System Using the time-dependent CFD simulation coupled with HVAC control, it is possible to control the timedependent HVAC outputs dynamically responding to dynamic changes of various B.C.s (e.g. solar radiation, outdoor temperature, etc). In this paper, however, 2

wall temperature ( ) atrium space (15 15 ) air temperature ( ), humidity (%) air mixing radiation from atrium exhaust outlet (3.0 0.1) lighting (3.00.2) 6.0 air curtain (3.00.1) atrium (1515) semi-enclosed space (a) Semi-closed Space Opening into Atrium (b) Details of Semi-closed Space Fig. 3 Semi-enclosed Space for Simulation (unit: m) (half the space of the symmetrical room is illustrated) Table 1 Cases Analyzed and Conditions Given Case 1 2 3 4 Atrium Wall and air temperature [].0.0.0.0 Humidity [%].0.0.0.0 Given sensible heat load [kw] 0.6 0.6 0.6 0.6 Semi-enclosed Given latent heat [kw] 0.1 0.1 0.1 0.1 space Operative temperature for human model [].0.0.0.0 Radiation-panel for cooling Area [m 2 ] 15.1-15.1 - Humidity [%] 0.0 0.0 Supply outlet of all-air [m 3 /s] 1620.0-907.0 cooling system Air flow rate [h -1 ].0 17.0 Air flow rate [ACH] [h -1 - ].0.0 Air-curtain Outlet velocity [m/s] - 3.0 3.0 Cooling load [kw] 0.0 0.0 3.0 human model (1.680. 0.1) symmetrical plane radiation panel for cooling (Case 1, 3) 3.0 suppy outlet (0..3) diffuser type (Case 2, 4) the assumption of steady-state indoor and outdoor conditions, which means that no dynamic changes of indoor/outdoor cooling loads, is introduced. In the simulation, the HVAC outputs are modified in proportion to the difference between the target value of OT and the output value i.e., simple proportional control is used here for the HVAC control. Procedure of New Simulation Method The procedure of the simulation is illustrated in Fig. 2. In this paper, two types of HVAC system are compared: one is a radiation-panel cooling system and the other is an all-air cooling system. In the case of the radiation-panel cooling system, the heat flux of the surface of the radiation-panel is modified based on q p,n+1, while the temperature of the supply outlets is modified in the case of the all-air cooling system [note 2, 3]. The cooling loads of the HVAC systems, to achieve the target value of the OT of the human model (), can be given through these simulations. The feedback system is stopped when this target point is achieved. OPTIMAL DESIGN BASED ON CFD FEEDBACK MECHANISM In this paper, only the B.C. of the heat flux of the radiation-panel and the air temperature of the supply outlet are modified in the simulation. However, with this method, other B.C.s (e.g., locations of supply outlets, number of supply outlets, etc.) can be modified so as to control the indoor climate at the target temperature. Through these simulations, the optimal design of HVAC system can be achieved. Although the description here concerns cooling system control, the same control could of course be applied to a heating system. SEMI-ENCLOSED SPACE To examine the performance of the new method, the thermal environment of a semi-enclosed space, which opens into an atrium space (15 m height), is analyzed (Fig. 3). For simplicity, all the walls, ceiling, and floor is assumed to be adiabatic. For this semienclosed space, two types of HVAC system are used for the study: one is a radiation-panel cooling system and the other is an all-air cooling system. In the CFD calculation here, the thermal environment of the atrium is modeled simply; the air and wall temperature, and humidity of the atrium are fixed at and % respectively. For this reason, only radiation heat transfer is analyzed within the atrium and thus the CFD simulation within the atrium is not carried out. 3

Table 2 Indoor Cooling Loads (given) Human Lighting Total Sensible Heat (kw) 0.2 0.4 0.6 Latent Heat (kw) 0.1 0.0 0.1 55 W and W are generated by one human model for sensible heat and latent heat respectively. The other sensible heat is assumed to be provided from the floor. Table 3 Conditions for Calculation Pressure Static pressure 0 at atrium Pressure B.C. Inflow k in = 3/2(U in 0.05) 2, ε in = C µ k 3/2 in /l in, l in = width of the opening, T in = Outflow Free slip Supply Outlet k in = 3/2(U in 0.05) 2, ε in = C µ k 3/2 in /l in, l in = width of the opening, T in is modified in response to the HVAC B.C. control system during CFD Velocity Generalized log-law, free slip at symmetric plane Temperature Radiation-panel: 5.5, adiabatic surface: 3.0, others: 4.0 (W/m 2 ) Convective heat transfer coefficient (α c ) Wall, Radiation-panel, 1. Human model: emission rate is fixed (Table 2). 2. Radiation-panel: AH (Absolute Humidity) is given corresponding to the saturated and Human vapor pressure, when the surface temperature of radiation-panel is lower than dew Humidity Model point temperature of the air. In other cases, Gradient of AH = 0. Humidity transfer coefficient α is calculated based on Lewis Relation. 3. Other wall: Gradient of AH = 0. Emissivity Wall, human model: 0.9 of radiation Symmetrical plane: 0.0 CFD : 40 (L)18 (W)18 (H) Mesh Radiation: 16 (L) 5 (W) 8 (H) [symbol] U in : air velocity of supply outlet [m/s] k in : turbulent kinetic energy of supply outlet [m 2 /s 2 ] ε in : dissipation rate of turbulent kinetic energy [m 2 /s 3 ] l in : turbulence length scale [m] T in : temperature of supply outlet [] α c : convective heat transfer coefficient [W/(m 2 )] α : humidity transfer coefficient [kg/(m 2 s(kg/kg))] 0.001α c Table 4 Predicted Results of Cooling Loads (values are given for half space of semi-enclosed space) Case 1 2 3 4 Sensible cooling load by [kw] 1.1 8.4 1.0 4.1 air-mixing Latent cooling load by [kw] 0.9 16.7 1.2 8.3 air-mixing Semi-enclosed space Sensible cooling load by [kw] 0.2 0.05 0.2 0.09 radiation Total cooling load [kw] 2.2 25.15 2.4 12.49 Air-mixing rate [m 3 /h] 931.0 5990.0 3370.0 36.0 Average room air temperature [].8 25.8.7.3 Sensible cooling load [kw] 1.9 1.8 Radiation-panel for Latent cooling load [kw] 1.0-1.3 cooling Surface temperature [] 14.4 14.2 - Temperature [] 9.6 8.5 Supply outlet of all-air Sensible cooling load [kw] - 9.0-4.8 cooling system Latent cooling load [kw] 16.8 8.4 The radiation-panels are installed in three walls (Fig. 3 (b), Case 1, 3 (Table 1)), operated below the dewpoint temperature. Consequently the panels have the ability to remove the humidity of the air in the room. In the case of the all-air cooling system, cold air is supplied through the supply outlets in the ceiling (Fig. 3 (b), diffuser type, one outlet for Case 4 and two outlets for Case 2). The efficiency of the air-curtain from the ceiling is also examined. It is installed to minimize the mixing of air between the atrium and the semi-enclosed space. Half of the semi-enclosed space (3.0 m) is analyzed since the space has a symmetrical configuration. The HVAC systems are controlled so as to keep the operative temperature (i.e. thermal sensation) of the human model in the center of the room at the target value (OT = ). CASES ANALYZED (Table 1) Four cases of HVAC system are analyzed in this study. The radiation-panel cooling system is used for Cases 1 and 3 and the all-air cooling system for Cases 2 and 4. In Cases 3 and 4, the air-curtain is installed at the entrance opening of the semi-enclosed space in order to minimize mixing of the air (Fig. 3). Since the temperature and relative humidity (RH) of the supply air of the air-curtain are set so as to be the same as those of the returned air itself, the air-curtain does not contribute to removing the cooling load. In case of 4

human model radiation-panel 3m/s (a) Case 1 0.3m/s (b) Case 2 air-curtain 3m/s (c) Case 3 Fig. 4 0.3m/s (d) Case 4 Flow Fields (Section through center of the room) <T< 25 () (a) Case 1 (average room air temperature:.8) < <T< (b) Case 2 (25.8) <18 18 20 22 22.5 21 22 23 > (c) Case 3 (.7) Fig. 5 Temperature Distribution (d) Case 4 (.3) the all-air cooling system in which the air-curtain is not installed (Case 2), the air volume from the supply outlets is increased to 1.8 times larger than that in Case 4, and two supply outlets are installed [note 4]. CONDITIONS FOR CALCULATION For analyzing the air-mixing between the atrium and the semi-enclosed space, a pressure type boundary condition is applied. Detailed information about the indoor cooling loads and the CFD boundary conditions are shown in Tables 2 and 3 [note 5, 6]. RESULTS Cooling Loads of Semi-enclosed Space (Table 4) The sensible cooling loads of the radiation-panel cooling systems (Case 1: 1.9 kw, Case 3: 1.8 kw, see Table 4) are % lower than that of the all-air cooling system with the air-curtain (Case 4: 4.8 kw). In Case 2, in which the all-air cooling system with no aircurtain is applied, the sensible cooling load (9.0 kw) is five times larger than those of the radiation-panel cooling systems. The latent cooling loads for the radiation system (Case 1: 1.0 kw, Case 3: 1.3 kw) are also lower than those for the all-air cooling systems (Case 2: 16.8 kw, Case 4: 8.4 kw). Induced by the supply jet of the air-curtain, the air-mixing rate between the atrium and the semi-enclosed space in Case 3 (3370 m 3 /h) becomes larger than that of Case 1 (913 m 3 /h). But since the air from the atrium cannot enter deeply inside the room as it is blocked by the air-curtain, the sensible cooling load due to air- 5

< < <h<62 62 62 64 64 68 68 70 72 h= (a) Case 1 (b) Case 2 58 58 56 58 62 61 63 64 67 65 < 64 68 64 62 < < 58 (%) (c) Case 3 (d) Case 4 Fig. 6 Relative Humidity Distribution mixing in Case 3 (1.0 kw) becomes a little smaller than that of Case 1 (1.1 kw). Flow Fields (Fig. 4) In Case 1 (Fig. 4 (a)), the air from the atrium enters at the upper part of the entrance opening and goes out near the floor. The cold air descends near the radiation-panel due to the negative-buoyancy effect. The air-mixing rate becomes smaller than the other cases (Table 4). On the other hand, in Case 2 (Fig. 4 (b)), the total cooling load (25.15 kw) is greater than the other cases due to the large air-mixing rate. In Case 3 (Fig. 4 (c)), the descending air flow pattern near the radiation-panel observed in Case 1 disappears due to the air-circulation induced by the air-curtain. The airmixing rate in Case 3 becomes 3.6 times as large as that in Case 1. In Case 4 (Fig. 4 (d)), the cold air from the supply outlet is mixed immediately with the room air by the effect of the air circulation. The air-mixing rate of Case 4 decreases compared to the result in Case 2. The blocking effect of the air-curtain is obvious in this case. Temperature Fields (Fig. 5) In Case 1 (Fig. 5 (a)), temperature stratification is formed; the temperature difference between the upper and the bottom part is about 4-5. The average room air temperature (.8) is higher than those of other cases. But the operative temperature for the human model is the same for all cases (.0). On the other hand, in Case 3 (Fig. 5 (c)), the temperature stratification disappears due to the air circulation induced by the air-curtain. The average room air temperature (.7) becomes lower than that in Case 1. In Case 2 (Fig. 5 (b)) which has two supply outlets, the temperature at the inner part of the room (22-) is lower than that in Case 1, due to the cold air from the supply outlet. Reflecting the lower air-mixing rate, Case 4 (Fig. 5 (d)) shows a lower average room temperature (.3) than the other cases. The temperature in the room is distributed uniformly in this case. Relative Humidity (Fig. 6) In Case 1 (Fig. 6 (a)), the relative humidity exceeds % in the whole area. Because of the cold air generated by the radiation-panel, high RH is observed near the floor, and so a stratification of RH is produced. In Case 2 (Fig. 6 (b)), RH is about % around the human model. The lowest RH distribution is observed in Case 2 compared to the other cases, which may be attributed to the large amount of latent cooling load removed by the HVAC system (16.8 kw). The latent cooling load of Case 2 is greater than that of other cases. In Case 3 (Fig. 6 (c)), the stratification of RH, which was observed in Case 1, disappears due to the air circulation produced by the aircurtain. The RH around the human model in Case 3 is about 65%, the highest among the four cases. In Case 4 (Fig. 6 (d)), a uniform RH distribution is observed. Distribution of Wall Surface Temperature and MRT of Human Model (Fig. 7) MRT (.6) for Case 1 is much lower than those of the all-air cooling systems (Case 2, 4), despite having a much higher average room air temperature. The average surface temperature of the radiationpanel is 14.4. The temperatures of the ceiling and the floor for Case 1 are lower than those of Case 2, which have large view factors between the radiationpanels so that a large amount of heat is removed by 6

Radiation-panel Surface Temp. : 14.4 CoolingLoad : 1889 W Human Model Surface Temp. :.2 MRT :.6 OT :.0 17 16 15 13 14 10 12 > 23 25 14 () Radiation-panel (a) CASE 1 (b) CASE 2 Human Model Surface Tem p. :.3 MRT :.1 OT :.0 32 25 Radiation-panel Surface Temp. : 14.2 Cooling Load : 1814 W Human Model Surface Temp. :.2 MRT :.9 OT :.0 16 15 14 (c) CASE 3 (d) CASE 4 Fig. 7 13 12 > 12 14 >14 Radiation-panel Wall Temperature Distribution and MRT of Human Model Human Model Surface Tem p. :.2 MRT :.7 OT :.0 > <.5.5 radiation. In Case 2 (Fig. 7 (b)), the temperature of the ceiling is about. On the other hand, the temperature of the floor is relatively low (20-) due to the cold air from the supply outlet. MRT is.1. The difference in MRT between Cases 1 and 3 (Fig. 7 (c)) is very small (0.3). In Case 4 (Fig. 7 (d)), the ceiling has a lower temperature compared with Case 2. This indicates that the air-curtain effectively blocks the hot air coming from the atrium. 50 40 20 10 12.0 43.0.6 37.6 17.4 14.4 40.6.0 35.8 (W) 19.3 Characteristics of Heat Transfer in Human Model (Fig. 8) In case of the radiation-panel systems (Case 1, 3), the amount of heat transfer by radiation from the human body is about four times larger than that by convection. Half of the total heat load from the human model (55W) is removed by the radiation-panel. But in the case of the all-air cooling systems (Case 2, 4), the amount of heat transfer by convection is two times larger than that by radiation on the contrary. 0 Case 1 Case 2 Case 3 Case 4 Fig. 8 convective heat transfer radiative heat transfer absorbed by wall (except radiation panel) radiative heat transfer absorbed by radiation panel Characteristics of Heat Transfer from Human Model CONCLUSIONS 1. A new CFD technique, coupled with a radiative heat transfer simulation and HVAC control, was proposed. With this new method, the required cooling loads for attaining the same thermal sensation for occupants (OT = ) were quantitatively evaluated for several HVAC systems. 2. In order to control the thermal environment of the semi-enclosed space, which opened into an atrium, the radiation-panel system was evaluated as very energy-efficient in this study. 3. In case of the all-air cooling system, the cooling load was reduced by installing an air-curtain at the entrance opening. 4. The analyses showed that the feedback design system for HVAC supported by the coupled simu- 7

lation is a very powerful tool for environmental design. REFERENCES 1. S. Kato, Application of CFD for analyzing the indoor environment (Part 7), The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, Jan. 1998 (in Japanese) 2. Taeyeon Kim, S. Kato, and S. Murakami, Heat Load Analysis through Coupled Simulation of Convection, Radiation and System Control, Summary of Technical Paper of The Society of Heating, Air Conditioning and Sanitary Engineering of Japan, 1998 (in Japanese) 3. Taeyeon Kim, S. Kato, and S. Murakami, Study on Indoor Thermal Environment Controlled by Panel Cooling System with Condensation (Part 6), 3-D Coupled Simulation of Radiation, Convection, Heat Conduction and Humidity Transport within Gymnasium, Summary of Technical Paper of Architectural Institute of Japan, 1997 (in Japanese) 4. S. Murakami, S. Kato, D. Choi, H. Kobayashi, and T. Omori, Numerical Study on Thermal Environment in Air-conditioned Room by means of Coupled Simulation of Convective and Radiative Heat Transport (Part 2), Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No. 59, Oct. 1995 5. S. Murakami, S. Kato, D. Choi, H. Kobayashi, and T. Omori, Numerical Study on Thermal Environment in Air-conditioned Room by means of Coupled Simulation of Convective and Radiative Heat Transport (Part 1), Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No. 57, Feb. 1995 6. S. Murakami, S. Kato, and Jie Zeng, Combined Simulation of Airflow, Radiation and Moisture Transport for Heat Release from Human Body, ROOMVENT 98, 1998 7. S. Murakami, New Scales for Ventilation Efficiency and Their Application Based on Numerical Simulation of Room Airflow, ISRACE, 1992 8. Omori, T., Taniguchi, H., and Kudo, K., Prediction method of radiant environment in a room and its application to floor heating, SHASE Trans., 42, 9-18, 1990 9. Gebhart, B., A new method for calculating radiant exchanges, ASHRAE Transactions 65:321-332, 1959 NOTE 1 Usual HVAC systems in a room are controlled based on the air temperature at specific points of the room. But in the case where radiation has a large contribution, it is more rational to control the HVAC based on the OT at a target point. NOTE 2 Operative Temperature (OT) for a human model is defined as: OT = ( αcta + α rt r )/( αc + α r ) [] (1) α c : convective heat transfer coefficient [W/m 2 ] α r : radiative heat transfer coefficient [W/m 2 ] T a : air temperature [] T r : radiation temperature ( = MRT ) [] Since the convective heat transfer (q c [W/m 2 ]), the radiative heat transfer (q r [W/m 2 ]), the surface temperature of the human model (T cl []), the air temperature, and the radiation temperature are given in the process of simulation, α c and α r can be calculated as follows: q c = α (T T ) [W/m 2 ] (2) c a cl q r = α r (MRT Tcl ) [W/m 2 ] (3) Mean Radiation Temperature (MRT) of surface i of the human model is calculated based on: N MRTi = 4 Bij (Tj + 3) B ij j= 1 4 3 [] (4) : Gebhart absorption coefficient view from surface i to j T j : temperature of surface j [] N : total number of surfaces NOTE 3 In the present simulation, the latent heat removed by the radiation-panel is not controlled by the HVAC control system directly. In the case where the surface temperature of the radiation-panel becomes lower than the dew point temperature of the air near the radiationpanel, the absolute humidity (AH), which corresponds to the saturated vapor pressure of the surface of the radiationpanel, is given to the air on the surface. In other cases, it is assumed that no latent heat is removed by the radiationpanel. This means that the gradient of AH is set to be 0 on the radiation-panel. NOTE 4 In this paper, the operative temperature that does not consider the effects of humidity is used to evaluate the thermal sensation of occupants. To compare all cases under the same thermal sensation, the RH around the human model must be made the same for all cases. In the case of the all-air cooling system, the RH at the supply outlets is fixed at 0%. 0% RH of supply air is, of course, impractical. However, with this condition, RH around the human model can be kept at about % in Cases 2 and 4, which is similar to that for Cases 1 and 3. NOTE 5 A work-station of 9.-SPECint95 and 5.75- SPECfp95 is used for this simulation. About,000 iterations (220 hours in CPU time) were required for the steadystate solution. NOTE 6 In this simulation, the human thermal sensation is evaluated by operative temperature as the first step of the study; the influence of humidity (water vapor pressure) for the thermal sensation is not considered. In order to evaluate the human thermal sensation more precisely, such the effect will be included in the next step. 8