Installation manual for room air conditioner

Similar documents
YH9FZH12/18/24BAH-AFX

Ductless Split Air Conditioner

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Ductless S plit Air Conditioner

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

[FLARE CONNECTION TYPE] ATTENTION

Split-type Air-Conditioner

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Split-type Air-Conditioner

Ductless S plit Air Conditioner

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Split-type Air-Conditioner

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION

INVERTER SPLIT - TYPE

1. BEFORE INSTALLATION

Choosing the installation site. Installation. 07 Choosing the installation site

FLOOR TYPE AIR CONDITIONERS

TERRA Series CH-S09FHCP CH-S12FHCP CH-S18FHCP CH-S24FHCP. For proper operation, please read and keep this manual carefully.

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Notices for installation

1. BEFORE INSTALLATION

SPLIT WALL-MOUNTED AIR CONDITIONER

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

Air Conditioner Service Manual KSWT SERIES INSTALLATION INSTRUCTION. Wall-mounted Split Type

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

1. BEFORE INSTALLATION

GMZ3-24H-S GMZ4-28H-S GMZ4-36H-S

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Air Conditioner. user installation & manual manual. imagine the possibilities

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

42PHW / 42PHQ 42PHQ...K

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

AIR CONDITIONER (MULTI-SPLIT TYPE)

DAIKIN AIR CONDITIONER

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM1403DT-A RAV-SM1603DT-A. Model name: Concealed Duct High Static Pressure Type

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

1. BEFORE INSTALLATION

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only.

Installation Manual Super-Slim Four-Way Cassette

Mini-Split Air Conditioner

Safety Precautions (1)

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

AIR CONDITIONER SPLIT WALL MOUNTED

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Saunier Duval Clima, S.A.

1. BEFORE INSTALLATION

INSTALLATION MANUAL. R410A Split Series. Models ARX20GV1B ARX25GV1B ARX35GV1B ARX20JV1B ARX25JV1B ARX35JV1B. Installation manual R410A Split series

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

ROOM AIR CONDITIONER INSTALLATION MANUAL

High Wall Split Air Conditioners 53QHCT KHCT

CLIMATISEUR CACHÉ SYSTÈME SPLIT AVEC COMMANDE

SPLIT-TYPE ROOM AIR CONDITIONER

GMZ2-14H-S GMZ2-18H-S

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER

Operation & Installation Manual

INSTALLATION INSTRUCTIONS

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

INSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A

Indoor Unit Operation & Installation Manual

UltraV Series Outdoor Units

AIR CONDITIONER CASSETTE

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Split Air Conditioner

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

AIR CONDITIONER FLOOR CEILING

CLIMATISEUR CENTRAL AVEC CONTRÔLE ÉLECTRONIQUE SPLIT SYSTÈME - SÉRIE CD CENTRAL AIR CONDITIONER WITH ELECTRONIC CONTROL

SPLIT -TYPE ROOM AIR CONDITIONER

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

KTIM. Four-way Cassette Type

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

INSTALLATION MANUAL For authorized service personnel only.

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

AIR CONDITIONER CONSOLE

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

SPLIT -TYPE ROOM AIR CONDITIONER

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

INSTALLATION MANUAL. R410A Split Series. Models RXS20K2V1B RXS25K2V1B. Installation manual R410A Split series

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Split Air Conditioner

Transcription:

Installation manual for room air conditioner HSU-26HEK03/R2(D)/I HSU-35HEK03/R2(D)/I HSU-53HEK03/R2(D)/I HSU-71HEK03/R2(D)/I HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O Read this manual before installation and keep it for future reference. Please explain to the user how the product works and refer them to the operation manual. NO.0010553937

Content Preparation ccessory parts Selection pipe Drawing for the installation of indoor and outdoor units Refrigerant charge label Check for installation and test run p3 p3 p3 p3 p5 p6 p8 p8 2

Preparation ccessory parts Necessary tools for installation Remote controller (1) Drain hose (1) Driver Nibbler Hacksaw Hole core drill Spanner (17,19 and 26mm) Gas leakage detector or soap-and-water solution Vacuum pump Torque wrench (17mm, 22mm, 26mm) Pipe cutter Flaring tool Knife Measuring tape Reamer Refrigeration gauges Power source Install an exclusive circuit for the power. Check the power source voltage is the same as the rating plate. Selection of installation place Indoor Unit The place chosen to install the indoor unit should be: Not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not blocked or restricted. Where it is possible to drain easily, and where piping can be connected with the outdoor unit. Where conditioned air can be evenly distributed through the whole room. Where there is more than 1m distance from televisions, radios, wireless dry battery (2) Mounting plate (1) Plastic cap (4) Ø4X25 Screw (4) Selection of pipe NOTE: The thickness of the pipe must be at least 0.8mm. Cushion (4) Drain-elbow (1) Model Liquid pipe (Ø) Gas pipe (Ø) HSU-26HEK03/R2(D)/O ") 9.52mm (3/8") HSU-35HEK03/R2(D)/O ") 9.52mm (3/8") HSU-53HEK03/R2(D)/O ") 12.7mm (1/2") HSU-71HEK03/R2(D)/O ") 15.88mm (5/8") Power requirements Model Max rated current HSU-26HEK03/R2(D)/O 6.1 HSU-35HEK03/R2(D)/O 6.0 HSU-53HEK03/R2(D)/O 10.5 HSU-71HEK03/R2(D)/O 13.8 Pipe supporting plate (1) are on. Outdoor Unit The place chosen to install the outdoor unit should be: Strong enough to bear the unit, where vibration and noise are not increased. Where discharged air and noise do not cause a nuisance to the neighbours. Where a distance marked 3

Drawing for the installation of indoor and outdoor units More than 5cm (26/35/53) More than 10cm (71) ttention must be paid to the rising up of drain hose Optional parts for piping Non-adhesive tape C dhesive tape Saddle (L.S.) with screws More than 10cm G D E Connecting electric cable for indoor and outdoor Drain hose F G Heating insulating material Piping hole cover Left rrangement of piping directions Rear left Rear right More than 10cm F the outdoor unit (Unit:mm) Z elow Right More than 10cm (26/35/53) C X Y X More than 15cm (71) More than 10cm (26/35/53) More than 20cm (71) Dimensions Model x y z HSU-26HEK03/R2(D)/O 140 500 256 HSU-35HEK03/R2(D)/O 140 500 256 HSU-53HEK03/R2(D)/O 113.5 583 319.5 and G are supplied parts D HSU-71HEK03/R2(D)/O 113.5 633 340 Fixing of outdoor unit pipe length is 2m. E Fix the unit to concrete or block with horizontally. More than 60cm More than 15cm (9/12/18) More than 25cm (24) earthquake or strong wind. unit by attaching a vibration-proof mat. The picture above is just for your reference. Please refer to the actual product purchased. 4

Indoor Unit 1 Fitting of the Mounting Plate and Positioning of the Wall Hole 1. Find a suitable mounting location, ensuring there is adequate support to hold the weight of the unit, check it is level, then temporarily fasten the plate. 2. Check the plate is level, by hanging a thread with a weight from the central top of the plate or using a spirit level, then fasten securely. 3. Determine the wall hole location using a measuring tape. 2 Making a Hole on the Wall and Fitting the Piping Hole Cover Make a hole of mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation. Wall hole Ømm Indoor side Outdoor side Thickness of wall (Section of wall hole) G Piping hole pipe 3 Installation of the Indoor Unit HSU-26HEK03/R2(D)/I 938 Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them with adhesive tape [ Left Left-rear piping ] In case of left side piping, cut away, with a nibbler, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. 1. Insert the drain hose into the cavity of heat insulation materials of indoor unit. 265 245 20 20 245 2. Insert the indoor/outdoor electric cable from the back of the indoor unit, and pull it out on the front side, then connect them. 3. Coat the seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials, and it with adhesive tape. 60 100 60 229 480 110 Indoor/outdoor electric cable HSU-35HEK03/R2(D)/I 1046 Lid for right piping Lid for under piping pipe Lid for left piping Heat insulation material Drain hose Piping Pipe supporting plate Fix with adhesive tape 299 268 268 Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. 13 13 [ Other direction piping ] 70 191 85 667 135 70 Cut away, with a nibbler, the lid for piping (according to the piping direction) and then bend the pipe according to the position of wall hole. When bending, be careful not to crush the pipes. Connect the indoor/outdoor electric cable. 320 260 HSU-53HEK03/R2(D)/I 1156 260 Fixing the indoor unit body Hang the unit body onto the upper notches of the mounting plate. Move the body from side to side to it is securely. In order to the body onto the mounting plate,hold up the body on an angle from the underside and then pull it down perpendicularly. mounting plate 12 12 Unloading of indoor unit body 70 40 138 860 HSU-71HEK03/R2(D)/I 105 70 When you remove the indoor unit, use your hand to raise the body from the hooks, then lift the bottom of the body outward slightly and lift the unit on an angle until it separates from the mounting plate. Hooks mounting plate Fix a mounting bar to the side bar and lintel (sold separately), and then fasten the plate to the mounting bar. Refer to note 1, When the mounting plate is, for the position of wall hole. 5

1 2 ( ) ( ) cont. 4 Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. DRED Function 6.Please consult your reseller and/or installer to determine if you have a DRED appliance. Connect output from your home's electricity power meter (where available) to the RJ45 connector on the outdoor unit, as shown. (This function is unavailable on some models.) When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe is fitted or installed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. fter the cable connection, always fasten the connected cable with the wiring cover. 1 Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units (see page 4) Note When connecting the cable, the terminal number of indoor and outdoor units carefully. If wiring is not correct, the system will not operate correctly. Damage to the PC due to incorrect wiring is not covered by warranty. 2 Connection of pipes To bend a pipe, use the correct bending tool, so as not to crush the pipe, and the bending radius should be 30 to 40 mm or longer. Connect the pipe gas side The connection pipe is specialized for R410. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Electrical connection Spanner Torque wrench Pipe diameter (Ø) Liquid side 6.35mm (1/4") Liquid/Gas side 9.52mm (3/8") Gas side 12.7mm (1/2") Gas side 15.88mm (5/8") Fastening torque 18 N.m 42 N.m 55 N.m 60 N.m 4G0.75mm 2 e careful that foreign materials such as sand, etc. do not enter the pipe. The charge of refrigerant must be conducted by professional air conditioner engineer. efore adding additional refrigerant, perform air evacuation from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. 6 Power cable: 3G1.5mm 2 HSU-26HEK03/R2(D)/O HSU-35HEK03/R2(D)/O 4G0.75mm 2 Power cable: 3G2.5mm 2 HSU-53HEK03/R2(D)/O HSU-71HEK03/R2(D)/O POWER POWER 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire and power cable is H05RN-F or H07RN-F. 2. If the PC board fuse is broken replace with a T.3.15/250VC (Indoor) or T.25/250VC (Outdoor). 3. The wiring method should be in line with the local and national wiring standards. 4. fter installation, the power isolator should be easily reached. 5. breaker should be incorporated into wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. { 1 2 3(C) L N Oil trap CUTION Max.Elevation: max = 10m (HSU 26/35) = 15m (HSU 53/71) In case the elevation is more than 5m, oil trap shoud be installed every 5~7m Max. Length: max = 15m (HSU 26/35) = 25m (HSU 53/71) Model ase charge Pre charge pipe length dditional charge amount HSU-26HEK03/R2(D)/O 1000g 7m 20g/m HSU-35HEK03/R2(D)/O 1080g 7m 20g/m HSU-53HEK03/R2(D)/O 1550g 10m 20g/m HSU-71HEK03/R2(D)/O 2100g 10m 50g/m

cont. 3 Connection of Electrical Cable Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. If wiring is not correct, proper operation can not be carried out and the controller may be damaged. Fix the cable with a clamp. 4 ttaching Drain-Elbow 4 If the drain-elbow is used, please attach it as (Note: Only for heat pump unit.) 45 5 Evacuation Method: Use vacuum pump Step 1 Remove the service port cap from the 3 way valve, the valve caps for the 2 way & 3 way valves. Connect hose to the service port (low) side of the manifold gauge. Then connect the centre hose from the manifold gauge to the vacuum pump. 2-way valve Liquid Side 3-way valve Gas Side Gauge manifold (for R410) Step 4 Open the 2-way valve to an angle of anticlockwise 90 degrees. fter 6 seconds, close the 2-way valve and test for refrigerant gas leakage. Open 90 O Step 5 2-way valve 3-way valve No gas leakage? If ok, proceed to Step 6. In case of refrigerant leakage, tighten parts of pipe connections. If leakage stops, then proceed to Step 6. If this does not stop gas leakage, reclaim all refrigerant from the service port. fter and repeating vacuuming on the system, with the prescribed refrigerant level. Check again for leaks. Step 6 Detach the charge hose from the service port, open 2-way valve and 3-way valve. Turn the valve anticlockwise until closed. Tube (for R410) Vacuum pump (for R410) 2-way valve 3-way valve Step 2 Open the tap on the low side of the manifold and operate the vacuum pump. If the gauge (low) reaches a vacuum immediately repeat step 1 above again. Open Step 7 To prevent refrigerant leakage, tighten the service port s taps and caps to ensure they are sealed. 2-way valve 3-way valve Valve rod cap Step 3 Vacuum for over 15min. Check the (low) gauge which should read -0.1 MPa (-76 cm Hg) at Iow pressure side. fter completion of vacuuming the system, close the low tap on the manifold and turn off the vacuum pump. Check the low side gauge to see if it holds for 1-2 min. If the gauge does not hold pressure, check all the and return to the beginning of Step 3. Valve rod cap Service port cap Step 8 fter the caps, check for refrigerant gas leakage around the caps. Close CUTION If the refrigerant of the air conditioner leaks, it is necessary to reclaim all the refrigerant, then pull a vacuum EFORE recharging the refrigerant into the air conditioner according to the amount marked on the name plate. Please do not charge with refrigerant, except as (R410), or allow air to enter into the cooling circulation system. Otherwise, this may cause abnormal high pressure in the system which may lead to personal injuries or damage to piping. 7

cont. 1 Power Source Installation The air conditioner must be wired with a dedicated circuit to the distribution board. The protection device should be sized to meet the current requirements of the unit as shown on page 3 and comply with local and national wiring standards. If installing the air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker. 2 Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burrs must be removed. Refrigerant charge label Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410 1= 2 2= kg 1 F E kg 1+2= kg Protocol. Do not vent into the atmosphere. Refrigerant type: R410 GWP* value:1975 GWP=global warming potential C D Flare tool for R410 Conventional flare tool Clutch-type clutch-type(rigid-type) Wing-nut type (Imperial-type) 0~0.5mm 1.0~1.5mm 1.5~2.0mm Flare tooling die 1.Cut pipe 2.Remove burs 3.Insert the flare nut 4.Flare pipe be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). factory refrigerant charge of the product: see unit name plate C D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging Correct Incorrect Check for installation and test run Please kindly explain to our customers how to operate the unit through the instruction manual. Lean Damage of flare Crack Partial Too outside Check items for test run Put check mark in boxes 3 On Drainage Please install the drain hose to be always sloping downhill. Examples of incorrect Gas leak from connecting pipe? Insulation of pipe connecting? re the indoor and outdoor interconnecting cables interconnecting cables It becomes high midway. The end is immersed in water. Less than 5cm It waves. The gap with the There is the bad ground is too small. smell from a ditch Is drainage securely carried out? Is the earth line securely connected? Is power source voltage correct? Is there any noise? condensate is carried to outdoor. In case that the attached drain hose is in a room, please apply insulation to drain. Is the indicator lamp lit? re cooling and heating (when in heat pump) performing normally? Is the operation of room temperature adjustment normal? 8