Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Product Data RELIABILITY FEATURES

62DA,DB,DC,DD,DE,DF07-38

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Commercial. Submittal Data Form

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

RGE 13 A T - 1 A

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Submittal Data Performance Data Electrical Data

13 GEP A L P - 1 A

Ruud Commercial Achiever Series Package Gas Electric Unit

RHEEM PACKAGE GAS/ELECTRIC

Advanced Product Data

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

GUIDE SPECIFICATIONS - 48TC**04-14

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Product Data. Fig. 1 - Unit 50VR -A

Advanced Product Data

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Summary Page

4YCC3048A3096A /3/ /

Input Cap. (Btuh) Stage 2

Product Data. 48LC Ultra High Efficiency Gas Heat/Electric Cooling Packaged Rooftop 3to5NominalTons. Carrier s Most Efficient Commercial Rooftop Ever!

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PAR5. Product Specifications

Input Cap. (Btuh) Stage 2

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

TECHNICAL SPECIFICATIONS

R-410A LUXAIRE ACCLIMATE DYX MODELS 2-4 TON 60 Hertz

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

GUIDE SPECIFICATIONS - 48LC*004-06

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

G6RC Series TECHNICAL SPECIFICATIONS

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

RG7D 1-Stage Heat Series

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. Fig. 1 - Unit 50EZ -A

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

GUIDE SPECIFICATIONS 48LC**14-26

GUIDE SPECIFICATIONS - 48HC*D17-28

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL SPECIFICATIONS

Model 581B Sizes to12 1 2Tons

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Product Data KUWAIT SERIES

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

SUBMITTAL DATA. Medbrooke ADD. Stuart Mc Munn Company 137 North Sixth Street Clarksburg, WV for. Prepared for

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

REPLACEMENT PARTS LIST

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

High Heat COP. High/Low Stage

Transcription:

Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Copyright 2008 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 11/08 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No:48TC---03SB Replaces: NEW

Job Data: Location: Buyer: Buyer P.O.#: Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: This product has been designed and manufactured to meet Energy Star criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. DESCRIPTION units are high-efficiency, single -packaged electric cooling, gas heating units that are pre-wired and pre -charged with PuronR (R-410A) HFC refrigerant. Units utilize an all aluminum flat micro-channel tube with louvered fins condenser coil NOVATIONt. The units are factory tested in both heating and cooling modes. These units meet the ASHRAE 90.1-2007 and Energy Star minimum efficiency levels as well as also meeting 2010 efficiency standards. Base Unit S Puron (R-410A) HFC refrigerant S ARI certified efficiency levels up to 11.1 EER S Rated in accordance with ARI Standard 360 S Designed in accordance with Underwriters Laboratories Std 1995 and listed by UL and UL, Canada S Two-stage cooling capacity control S Non-corrosive composite sloping design; side or center drain condensate pan. Meets ASHRAE Standard 62 S Standard cooling operating range from 40_F upto 115_F (4_C upto46_c). Field installable accessory extends the minimum down to -20_F (-29_C). S Convertible from vertical to horizontal airflow for slab mounting S Two-inch disposable return air filters S Thru-the-bottom power and gas entry capability S Single point gas and electric connections S 24-volt control circuit protected with resettable circuit breaker and 75-VA transformer S Belt drive, constant torque, permanently lubricated evaporator-fan motor S Totally enclosed condenser motors with permanently lubricated bearings S Low-pressure and high-pressure switches S Full perimeter base rail with built-in rigging adapters and fork truck slots S Centralized Terminal Board for component and unit wiring connections STANDARD FEATURES Cabinet S Access panels with easy grip handles and NO-STRIP screw collar S Pre -painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection S Fully insulated cabinet S Tool-less filter access door Refrigerant System S Acutrolt refrigerant metering system S Liquid line filter drier S Scroll compressors with internal line-break overload protection S Copper tube, aluminum fin evaporator coil S NOVATION all aluminum condenser coil S Removable gauge line plugs for reading refrigerant pressure with unit panels in place Gas Heat S IGC solid-state gas heat exchanger control for on-board diagnostics, anti -cycle protection, LED error code designation, burner control logic and energy saving indoor fan motor delay S Gas efficiencies up to 82% S Designed in accordance with ANSI Z21.47 (design and test standard for gas furnaces) and ANSI Z233.1 (National Fuel Gas code relating to appliance installation requirements) S Induced draft combustion S Redundant gas valve, with up to 2 stages of heating S Flame roll -out safety protector S Solid-state electronic direct spark ignition system 2

STANDARD FEATURES (cont.) Standard Warranty S 15-year gas heat exchanger - Stainless Steel S 10-year gas heat exchanger - Aluminized S 5-year compressor S 3-year NOVATION condenser coil S 1-year parts PERFORMANCE DATA Unit Operating Weight lb Cooling Gross Total Capacity: Btuh at Condenser Air Temperature _F Gross Sensible Capacity: Btuh Compressor Power Input: kw Indoor Entering db _F wb _F Airflow External Static Pressure in.wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp Curb Weight Heating Heating Capacity: Stage 1 Stage 2 Heating Capacity Total Stage 1 Stage 2 Heating Capacity Total lb Btuh Btuh Btuh kw kw kw ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection Job Name Architect Engineer Contractor Unit Designation SUBMITTAL DATA 3

OPTIONS AND ACCESSORIES FACTORY -INSTALLED OPTIONS (FIOPs) j Open protocol RTU-MP controller communicates to. LON, MODBUS, BACNET and Johnson N2 protocols. j CCN Direct Digital Control (DDC) - PremierLink j Through the base connectors for gas and electric conduit/piping j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Economizer with dry bulb sensing and barometric relief j Economizer with enthalpy sensing and barometric relief j 2 position motorized outdoor air damper j Non-fused disconnect j Powered 115-volt convenience outlet j Non-powered 115-volt convenience outlet j High static evaporator fan motor j Return Air smoke detector j Supply Air smoke detector j CO 2 sensor j Condenser hail guard - louvered style OPTIONAL WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start -Up and Optional Extended Warranty Price price pages for further information. FIELD INSTALLED ACCESSORIES j Economi$ert IV-electromechanical, gear driven with Belimo actuator (2-10v DC signal) and controller j Economi$ert2-compatible with DDC controls; gear driven with Belimo actuator (4-20mA) signal and no controller j Power exhaust j Two-position motorized outdoor air damper j Manual outside air damper 25% j Manual outside air damper 50% j Roofcurb - 14 inch (356mm) tall j Roofcurb - 24 inch (610mm) tall j Thru-the -bottom connections-electrical only j Thru-the-bottom connections-electrical and gas j Condenser hail guard - louvered style j Flue shield j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Winter start kit, down to 25_F (-4_C) j Low ambient head pressure controller, downto0_f (-18_C) j Low ambient head pressure controller, down to -20_F (-29_C) j Time Guard II compressor anti -cycle protection Economizer Sensors j Single Dry bulb control j Differential Dry bulb control j Single enthalpy control j Differential enthalpy control j CO 2 - wall mounted j CO 2 - duct mounted j CO 2 - unit mounted 4

CERTIFIED DIMENSION 08, 12 C08495 5

CERTIFIED DIMENSION 08, 12 C08496 6

CERTIFIED DIMENSION 14 C08497 7

CERTIFIED DIMENSION 14 C08498 8

ROOF CURB DETAILS ROOFCURB ACCESSORY CRRFCURB003A01 CRRFCURB004A01 1-2 (356) 2-0 (610) UNIT SIZE 08, 12, 14 C08546 9

10

11

12