EIA-232D Protocol And Data Formats for the AFP-200 Fire Alarm Control Panel

Similar documents
FieldServer Driver - Serial FS Notifier NCA

Section 9 System Operation

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Section 8 System Operation

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Fire Command Center. XR2400F User s Guide

The Challenger Version 8 User Guide

AFP-300/AFP-400 Analog Fire Panel

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

USER MANUAL FOR OPERATING SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

2000 Series. Program Entry Guide. Control Panels

TrueAlarm Fire Alarm Systems

P2267 NETWORK INTERFACE

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Laptop / PC Programming Manual

HERCULES 6 GRAPHICS SYSTEM

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Simplex Panel Interface Guide

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

SC-F3G User Manual 1.0

user manual Document No , Revision 03 November 2015

IRIS Touch Firmware Enhancements and Additions from Version to Version

FieldServer FS Secutron

ANNUNCIATOR FIXED MODULE

SCAN200E USER S MANUAL

1. Introduction. 1.1 Features

D1255RB/D1256RB/D1257RB

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Water alarm. Water detection system L-PS-X / LS-X. Højmevej Odense SV Tlf Fax

Liquid Crystal Display LCD-80. Installation Manual. Document /9/02 Rev: D2 PN 15037:D2 ECN

DS7400Xi Addressable Control/ Communicator

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

21-light Remote Annunciator. Owner s Manual

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

UAS 7000 Local Management

Halton SAFE / 7.14 user guide and installation instructions

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

VISTA-50P VISTA-50PUL

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Trident User s Manual

Xtralis VESDA LCD Programmer Quick Reference Guide

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Operating Instructions MXL Multi-Line Keyboard/Display Panel

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Fire Alarm Control Panels FPD-7024

Intelligent Security & Fire Ltd

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Added password for IP setup page : Password must be in IP format!

The ACM-8R Annunciator Control Module

FMR Installation Instructions. Addressable Fire System Controller

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

INSTALLATION INSTRUCTIONS

Fire Command Center XR2500F. User s Guide

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

FST DFS Notifier Onyx 640

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

GLOBAL. InstallatIon & operation manual

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Model A1700 Series Annunciator

AES FireTap Model 7770

FCD-wire Contents. List of Figures

The supplier and installer of the system should be approved by the local civil defence authority.

/14 Rev. A LYNX Touch L5210 Series

Section 4: Operating Instructions

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

FieldServer Driver - Serial FS Grinnell TFX Minerva

SYSTEM 5000 USER MANUAL

SENTROL ZX400/ZX410. Security System Control. Programming

FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators reference guide

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ID2000. operating manual

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

FS Mircom FX2000 Fire Alarm Panel

XR500/XR100. User s Guide

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

ModBus DE-1 INSTALLATION AND USER MANUAL

D1265. User's Guide. Touchscreen Keypad

Document No Issue 4 user manual

MPC-6000 / MPC-7000 / RND-2

Transcription:

12 Clintonville Road Northford, CT 06472 TEL (203) 484-7161 FAX 203.484.7718 EIA-232D Protocol And Data Formats for the AFP-200 Fire Alarm Control Panel DOCUMENT # 50078 05/18/94 REV: A P/N 50078:A ECN 94-143

Table of Contents Section 1.0 Introduction... Page 3 Section 2.0 Protocol... Page 3 Section 3.0 Interface Connections... Page 3 Section 4.0 Input Characters... Page 3 Section 4.1 Special Function Keys... Page 3 Section 5.0 Output Characters... Page 4 Section 5.1 Printer Characters... Page 4 Section 5.2 Message Terminator... Page 4 Section 6.0 Modes of Operation... Page 5 Section 6.1 Local Terminal Mode... Page 5 Section 6.2 Local Monitor Mode... Page 5 Section 6.3 Remote Monitor Mode... Page 5 Section 7.0 Message Formats and Descriptions... Page 6 Section 7.1 Alarm Messages... Page 6 Section 7.2 Point Trouble Messages... Page 7 Section 7.3 Normal Messages (Addressable Detectors)... Page 8 Section 7.4 Normal Messages (Addressable Modules)... Page 8 Section 7.5 Pre-Alarm Messages... Page 9 Section 7.6 Pre-Alarm Clear Messages... Page 9 Section 7.7 System Trouble Messages... Page 10 Section 8.0 Read Status... Page 11 Section 8.1 Point Read... Page 11 Section 8.2 Alarm and Trouble Status... Page 11 Section 8.3 Read All Points... Page 11 Section 8.4 Read History - Step... Page 12 Section 8.5 Read History - All... Page 12 Section 9.0 Status Change... Page 12 Section 9.1 Disable/Enable... Page 12 Section 9.2 Detector Sensitivity... Page 13 Section 9.3 Clear Verification Counters... Page 13 Section 9.4 Clear History Buffer... Page 13 Section 9.5 Action and Alert Levels... Page 14 Section 10.0 System Commands... Page 14 Section 10.1 Acknowledge... Page 14 Section 10.2 Signal Silence... Page 14 Section 10.3 System Reset... Page 15 Section 10.4 Manual Evacuate... Page 15 Appendix A: AFP-200 Type Codes... Page 16 Appendix B: AFP-200 Status Banners... Page 17 Appendix C: European Mode... Page 18 2

1.0 Introduction This document defines the protocol and data formats that the Notifier AFP-200 Fire Alarm Control Panel uses to communicate information over the EIA-232D serial interface. 2.0 Protocol The AFP-200 FACP protocol is as follows: - serial communications - 2400 BAUD - full duplex - 1 start bit - 7 data bits - 1 parity bit - even parity - 1 stop bit 3.0 Interface Connections The serial interface used to connect the AFP-200 to external devices (terminals, monitors and printers) is located on the AFP-200 motherboard terminal block TB4 and is as follows: AFP-200 TB4 Function DB-25 Connector Terminal 1 Transmit Pin 3 Terminal 2 Reference Pin 7 Terminal 3 Receive Pin 2 4.0 Input Characters The following sections describe the valid data characters the AFP-200 FACP will process, all other input characters will be ignored. The general input characters are as follows: Characters Hexadecimal Codes A - Z 41-5A a - z 61-7A 0-9 30-39 Space 20 ( 28 ) 29-2D. 2E Back Space 08 Carriage Return 0D ~ 7E 4.1 Special Function Keys The following list defines the character codes the AFP-200 FACP will look for when a special function key is depressed. These keys must be programmed as defined for proper special function key operation. Key Function Code F1 Read Status ~A F2 Alter Status ~B F5 Prior ~E F6 Next ~F F12 Acknowledge ~L F13 Signal Silence ~M F14 System Reset ~N Shift F13 Manual Evacuate ~Q 3

5.0 Output Characters The general output characters are as follows: Characters Hexadecimal Codes A - Z 41-5A 0-9 30-39 Space 20 " 22 # 23 ( 28 ) 29 * 2A + 2B, 2C - 2D. 2E / 2F : 3A = 3D? 3F Carriage Return 0D Line Feed 0A BELL 07 Solid Block FF ESCape 1B @ 40 f 66 g 67 5.1 Printer Characters The printer characters are as follows: Characters Hexadecimal Codes A - Z 41-5A 0-9 30-39 SPace 20 " 22 # 23 ( 28 ) 29 * 2A + 2B, 2C - 2D. 2E / 2F : 3A = 3D? 3F Carriage Return 0D Line Feed 0A ESCape 1B x 78 NULL 00 5.2 Message Terminator The terminator for an 80 character output message is a Carriage Return (0D hexadecimal) followed by a Line Feed (0A hexadecimal). 4

6.0 Modes of Operation The AFP-200 FACP may communicate with a remote terminal, computer or printer connected to its EIA-232 serial port. The EIA-232 port can be configured for interactive operation or for monitoring only. Interactive operation requires that all equipment be UL listed under UL Standard for Safety UL864 and be installed/configured as directed under "Local Terminal Mode (LocT)" or "Local Monitor Mode (LocM)." Electronic Data Processing (EDP) listed equipment is permitted for ancillary system monitoring when the system is installed/configured as directed under "Remote Monitor Mode (RemM)." Note: The use of EDP listed equipment is also permitted for temporary applications such as system servicing or programming. The EIA-232 ports on some terminals/computers, including the Notifier CRT-2, are not isolated from earth ground. These devices should be connected to the AFP-200 via isolation modems only, since their direct connection would result in a ground fault being introduced on the AFP-200. There are three different operating modes for the EIA-232 port, Local Terminal, Local Monitor, and Remote Monitor. The operating mode is selected during panel programming, under the system parameters section (7=SYSTEM). The operation of each mode is described in the following section. 6.1 Local Terminal Mode (LocT) Local Terminal Mode operation allows the user to perform Read Status and Alter Status operations from the terminal. In addition the user can also Acknowledge, Signal Silence, Reset, and perform a Drill function from the terminal. A user definable password is required to perform the Alter Status function. The following functions are available when operating in Local Terminal Mode: Note: The Terminal must be mounted in a UL-864 listed enclosure, a Notifier Rack-51, Rack-67 or arranged to provide equivalent protection against unauthorized use. Read Status Display the status of an individual point (Detector, Module, Panel Circuit, or Zone) Display a list of all the points in alarm or trouble Display a list of all programmed points in the system Step through the history buffer event by event Display the entire history buffer Alter Status Disable/Enable an individual point Change the sensitivity of a detector Clear the verification counter of all detectors Clear the entire history buffer Set the AWACS alert and action levels Control Functions Acknowledge Signal Silence System Reset Drill 6.2 Local Monitor Mode (LocM) Local Monitor mode operation allows the same functions as Local Terminal mode with the exception that a password is required to perform Acknowledge, Silence, Reset, and Drill. Because of this password security feature the terminal does not need to be enclosed in a rack to prevent unauthorized use. 6.3 Remote Monitor Mode (RemM) Remote Monitor mode operation only permits the user to perform the Read Status function. This mode can be used with UL EDP listed terminals, including personal computers using Notifier PK-1 release 2.0 software or terminal emulation software. It is also intended for terminals that are connected through modems, including FSK modems connected through a public switched telephone network. 5

7.0 Message Formats and Descriptions The following section describes the different types of 80-character message strings produced by the AFP-200 Fire Alarm Control Panel. These are shown using the 1 line by 80 character format that would typically be displayed on a monitor or 80-column printer. Sections 8.0 and 9.0 detail inquiries and programming changes that may be made via the EIA-232D port. Note: Section 7.0 details the AFP-200 messages as they would appear while the panel is operating in normal USA mode. For information regarding European mode operation refer to Appendix C. 7.1 Alarm Messages ALARM:@SMOKE@(ION)@@<CUSTOM@POINT@LABEL@<CUSTOM@ZONE@LABEL>@@HH:MMA@MM/DD/YY@DNN Status Field ALARM: ACTIVE Type Code Field (12 Characters) SMOKE@(ION) SMOKE(PHOTO) HEAT(ANALOG) MONITOR PULL@STATION SMOKE@DETECT HEAT@DETECT WATERFLOW SUPERVISORY TAMPER NON@FIRE HAZARD@ALERT FIRE@CONTROL ABORT@SWITCH MAN.@RELEASE SILENCE SYSTEM@RESET EVACUATE PAS@INHIBIT TROUBLE@MON BURGLAR@ALA Custom Point Label (19 Characters) The user defined label for the activated device will be displayed in this field. Custom Zone Label (19 Characters) The user defined label for the first zone that is mapped to this device will be displayed in this field. Time of Alarm/Activation The time the device was activated will be displayed in an hour:minutes format, with the last character of the string being either an A for AM or a P for PM. Date of Alarm/Activation (8 Characters) The date the device was activated will be displayed in a month/date/year format. Leading zeros for the month and date will be present if required. Device Type and Address An M (Module) or D (Detector) will be displayed followed by a two digit address (01 to 99). 6

7.2 Point Trouble Messages TROUBL@PULL@STATION@<CUSTOM@POINT@LABEL@ZXX@<<TROUBLE@TYPE>>@HH:MMA@MM/DD/YY@DNN Status Field TROUBL CLR@TB Type Code Field (12 Characters) SMOKE@(ION) SMOKE(PHOTO) HEAT(ANALOG) MONITOR PULL@STATION SMOKE@DETECT HEAT@DETECT WATERFLOW SUPERVISORY TAMPER NON@FIRE HAZARD@ALERT FIRE@CONTROL ABORT@SWITCH MAN.@RELEASE SILENCE SYSTEM@RESET EVACUATE PAS@INHIBIT TROUBLE@MON BURGLAR@ALA Custom Point Label (19 Characters) The user defined label for the activated device will be displayed in this field. Zone Number The zone number of the first zone that is mapped to this device will be displayed in this field. Trouble Type (16 Characters) The type of trouble for this device will be displayed in this field. INVALID@REPLY DEVICE@DISABLED OPEN@CIRCUIT SHORT@CIRCUIT MAINTENANCE@REQ DET@FAILED@TEST DRIFT@COMPENSATE Time of Alarm/Activation The time the device was activated will be displayed in an hour:minutes format, with the last character of the string being either an A for AM or a P for PM. Date the Trouble occurred (8 Characters) The date the device entered trouble or cleared will be displayed in a month/date/year format. Leading zeros for the month and date will be present if required. Device Type and Address An M (Module), D(Detector), or B(Bell Circuit) will be displayed followed by a two digit address, 01 to 99 for detectors and modules and 01 to 04 for Bell circuits. 7

7.3 Normal Messages (Addressable Detectors) NORMAL@SMOKE(PHOTO)@<CUSTOM@POINT@LABEL@ZXX@ZXX@ZXX@ZXX@ZXX@@HH:MMA@MM/DD/YY@DNN Status Field NORMAL ON OFF Type Code Field (12 Characters) SMOKE@(ION) SMOKE(PHOTO) HEAT(ANALOG) Custom Point Label (19 Characters) The user defined label for the activated device will be displayed. Zone Mapping (20 Characters) The zone(s) (up to five) that the device is mapped to will be displayed in this field. The format is as follows Zxx_ where xx is the zone number (01 through 99) and _ is a blank space. Time The time the device was displayed will be shown in an hour:minutes format, with the last character of the string being either an A for AM or a P for PM. Date (8 Characters) The date will be displayed in a month/ date/year format. Leading zeros for the month and date will be present if required. Device Type and Address An D for Detector will be displayed followed by a two digit address 01 to 99. 7.4 Normal Messages (Addressable Modules) NORMAL@MONITOR@@@@@@<CUSTOM@POINT@LABEL@ZXX@ZXX@ZXX@ZXX@ZXX@@@@@@@@@@@@@@@@@@MNN Type Code Field (12 Characters) MONITOR PULL@STATION SMOKE@DETECT HEAT@DETECT WATERFLOW SUPERVISORY TAMPER NON@FIRE HAZARD@ALERT FIRE@CONTROL ABORT@SWITCH MAN.@RELEASE SILENCE SYSTEM@RESET EVACUATE PAS@INHIBIT TROUBLE@MON BURGLAR@ALA Device Type and Address An M for Modules or a B for Bell Circuit will be displayed followed by a two digit address 01 to 99 for Modules and 01 to 04 for Bell (Panel) Circuits. Note: Refer to Section 7.3 (above) for the remaining field descriptions. 8

7.5 Pre-alarm Messages PREALM@SMOKE(PHOTO)@<CUSTOM@POINT@LABEL@<STATUS>@PPP%/SSSS@@@HH:MMA@MM/DD/YY@DNN Pre-alarm Field PREALM Type Code Field (12 Characters) SMOKE@(ION) SMOKE(PHOTO) Custom Point Label (19 Characters) The user defined label for the activated detector will be displayed. Status Field (7 Characters) The status of the detector will be displayed in this field. The status will be one of the following: ACTION: ALERT: Percentage of Alarm (4 Characters) If the device is an Ionization detector, the percent of the alarm threshold is displayed in the following format 000% to 100%. If the device is a Photoelectric detector, the actual percent of obscuration is displayed in the following format 0.00% to 1.00%, 1.50% or 2.00% depending of the sensitivity setting. Sensitivity (4 Characters) The sensitivity of the detector will displayed in this field. If the device is an Ionization detector, the sensitivity will be displayed as either LOW_, MED_, or HIGH. If the device is a Photoelectric detector, the sensitivity will be displayed as 1.00%, 1.50%, or 2.00%. Time The time the device was displayed will be shown in an hour:minutes format, with the last character of the string being either an A for AM or a P for PM. Date (8 Characters) The date will be displayed in a month/date/ year format. Leading zeros for the month and date will be present if required. Device Type and Address An M for Module, D for Detector, or a B for Bell Circuit will be displayed followed by a two digit address 01 to 99 for Modules and Detectors and 01 to 04 for Bell Circuits. 7.6 Pre-alarm Clear Messages CLEAR@@SMOKE(PHOTO)@<CUSTOM@POINT@LABEL@ZXX@@@@PREALM@CLEAR@@HH:MMA@MM/DD/YY@DNN Status Field (5 Characters) The status of the detector will be displayed in this field. CLEAR Zone Number The zone number of the first zone that is mapped to this device will be displayed in this field. Pre-Alarm Clear Banner (12 Characters) Note: Refer to Section 7.5 (above) for the remaining field descriptions. 9

7.7 System Trouble Messages TROUBL@IN@SYSTEM@@@@<<<TYPE@OF@TROUBLE>>@@@@@@@@@@@@@@@@@@@@@HH:MMA@DAY@MM/DD/YY Trouble in system banner followed by 4 blanks (20 Characters) Type of Trouble (20 Characters) Each banner is preceded by a blank space. @GROUND@FAULT @AC@FAIL @BATTERY @STYLE@6 @OPTION@MODULE @TERM.@SUPERVISORY @ANNUN.@1@TROUBLE @ANNUN.@2@TROUBLE @ANNUN.@1@NO@ANSWER @ANNUN.@2@NO@ANSWER @EPROM@ERROR @INTERNAL@RAM@ERROR @EXTERNAL@RAM@ERROR @PROGRAM@CORRUPTED @NO@DEVICES@INSTALLED @AVPS.@TROUBLE Time The time the device was displayed will be shown in an hour:minutes format, with the last character of the string being either an A for AM or a P for PM. Day of Week A three letter abbreviation for the actual day of the week, such as: MON, TUE, WED, THU, FRI, SAT, SUN. Date (8 Characters) The date will be displayed in a month/date/year format. Leading zeros for the month and date will be present if required. 10

8.0 Read Status The Read Status function enables the user to: 1) View the present status of any point in the system 2) View all current alarms and troubles 3) View the status of all points, zones and system parameters 4) View a selected portion or all of the history buffer (650 events) A Read Status inquiry is initiated by sending a ~A to the AFP-200 Fire Alarm Control Panel. If the function keys are properly programmed this corresponds to pressing the function key F1. The AFP-200 will respond by sending the following character string: Read@point=1@@@@@@Alm/tbl@Status=2@@@@@Read@All@Points=3@@@History:@Step=4/All=5 8.1 Point Read To perform a Read Status on any point in the system the user must press the number 1 and the Enter key. The AFP-200 will respond by sending the following string: Enter@D(Det.)@/@M(Mod.)@/@B(Bell)@/@Z(Zone),AA@@OR@S(system@params.) The user may now perform a Read Status on any Detector, Module, Bell (panel) circuit, Zone, or System parameter by entering information in the following format: Dxx Enter where D is for Detector and xx is any address from 01 through 99 Mxx Enter where M is for Module and xx is any address from 01 through 99 Bxx Enter where B is for Bell Circuit and xx is circuit 01 through 04 Zxx Enter where Z is for Zone and xx is any zone number 01 through 99 S Enter where stands S for System parameters Once a detector, module, bell circuit or zone number is entered, the user may step through a list of these devices/zones by using the Prior (F5) or Next (F6) function keys. These function keys actually send a ~E and ~F to the AFP-200 respectively. 8.2 Alarm and Trouble Status To see a list of all the devices that are currently in alarm or trouble, the user should press the number 2 followed by the Enter key. The AFP-200 will send a series of 80-character lines for each alarm and trouble, including system troubles. Each line of text will be followed by a blank line. An example of an Alarm/Trouble Status report is shown below. TROUBL@IN@SYSTEM@@@@@GROUND@FAULT@@@@@@@@@@@@@@@@@@@@@@@@@@@@@03:26@FRI@04/30/94 TROUBL@IN@SYSTEM@@@@@BATTERY@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@03:45@FRI@04/30/94 8.3 All Points To get a continuous list of all detectors, modules, bell circuits, and zones in the system the user must press the 3 followed by Enter. The AFP-200 will send an 80-character line followed by a blank line for each device/zone in the system. 11

8.4 Read History - Step The user has the option of stepping through the history buffer one event at a time. Upon pressing the number 4 followed by Enter, the AFP-200 will respond with the following: EVENT@HISTORY@START@@@@@@@@@@@@@@@@@@@@EVENTS@IN@HISTORY@:@XXX Number of events in buffer The total number of events in the history buffer will be displayed in this field. The history buffer may contain up to 650 events. If the history buffer is empty, the following message will be sent by the AFP-200: @@@HISTORY@EMPTY@@@@@@@@@@@@@@@@@@@@@@@@**************************************** The AFP-200's pointer will be at the top of the history buffer. Pressing Next (F6)(~F) will cause the AFP-200 to respond by sending the oldest history event in 80-column format. Pressing Next again will allow the user to step one event at a time forward through the history buffer. By pressing the Prior (F5)(~E) key a user may step backwards through the history buffer. A sample history buffer report is shown below. ALARM:@SMOKE@(ION)@@<CUSTOM@POINT@LABEL><<CUSTOM@ZONE@LABEL>@HH:MMA@MM/DD/YY@DNN @ACKNOWLEDGE@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@12:45P@FRI@04/22/94 8.5 Read History - All By pressing 5 and then Enter, the panel will respond by sending the oldest event in the history buffer followed by a blank line. The panel will then continue to send each subsequent event (from the oldest to the most recent) until the entire history buffer has been dumped. 9.0 Status Change The Status Change function enables the user to: 1) Disable or enable any point in the system 2) Change the sensitivity of any addressable photoelectric or ionization detector in the system 3) Globally clear the verification counter 4) Clear the entire history buffer 5) Globally set the Action/Alert levels for the AWACS operation A Status Change inquiry is initiated by sending a ~B to the AFP-200 Fire Alarm Control Panel. If the function keys are properly programmed this corresponds to pressing the F2 function key. The AFP-200 will respond by sending the following character string: 1=Disable@2=Sensitivity@3=Clear@Verification@4=Clear@History@@5=Set@Action/Alert 9.1 Disable/Enable The user may selectively enable or disable any point in the system including addressable detectors, modules, and bell/panel circuits. After pressing the number 1 and then Enter, the AFP-200 will respond with the following inquiry. 12

Disable/Enable@D(Det.)@/@M(Mod.)@/@B(Bell@ckt.),AA From this menu prompt, the user may enable or disable any detector, module, or bell circuit. To enable or disable a specific device, the user must enter a D (detector), M (module), or B (bell circuit) followed by a two digit address. The address must be in the range of 01 to 99 for detectors and modules, and from 01 to 04 for bell/panel circuits. The example below shows addressable detector 30 being disabled. D30@Now@Enabled,@Enter@E(Enable)@/@D(Disable)@or@Esc.@to@Abort To disable this detector the user must enter a D. Shortly after pressing the D key, the AFP-200 will enter a trouble condition because a device has been disabled and the appropriate trouble message will be sent from the EIA-232 port. 9.2 Detector Sensitivity The user may change the sensitivity of any photoelectric or ionization detector in the system. This is done by pressing the number 2 and Enter at the Status Change prompt. An example of changing a detectors sensitivity is shown below. Det.@Sensitivity@@@@Enter@point:@AA,E 91 D91@now@@Hi@sens.@Enter@H,@M,@or@L@to@change,@Esc.@to@Abort Note: At the detector sensitivity prompt, the user need only enter the two digit address of the detector to change, it is not necessary to prefix the address with a D. 9.3 Clear Verification Counters The verification counters for all the addressable detectors may be reset back to zero by using this feature. The user must enter the number 3 followed by the Enter key. The AFP-200 will respond with the following prompt. Press@Enter@to@Clear@Verification@Counts@or@Esc.@to@Abort Pressing the Enter key will globally reset all the verification counters to zero. The Escape key aborts the operation without affecting the counters. 9.4 Clear History The entire history buffer may be cleared by using this function. The user must press the number 4 followed by the Enter key. The AFP-200 will respond with the following menu prompt. Press@Enter@to@Clear@History@or@Esc.@to@Abort Pressing the Enter key will erase the entire history buffer, all events will be lost. Pressing the Escape key aborts the function with no action being taken. 13

9.5 Action and Alert Levels By using this function the user may set the Alert and Action levels (AWACS operation) to any value between 1% to 100%. The user must press the number 5 followed by the Enter key. The control panel will respond with the following prompt. Set@%@of@Alarm:@Alert(T)@&@Action(N)@@@@Format:@TxxNxx@@then@Enter Example: To enter an Alert level of 60% and an Action level of 85%, the user would use the following format: T60N85 followed by the Enter key. 10.0 System Commands While connected to the EIA-232D interface, the user may send Acknowledge, Signal Silence, System Reset, and Manual Evacuate commands to the AFP-200. Note: The AFP-200 must be programmed for Local Terminal Mode (LocT) or Local Monitor Mode (LocM) in order for these commands to be accepted. The message formats for these commands are detailed in the following sections. 10.1 Acknowledge When the user initiates an Acknowledge (by pressing the F12 key and sending a ~L) the panel will respond with the following message: @ACKNOWLEDGE@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@HH:MMA@DAY@MM/DD/YY Time Day of Week Note: For detailed field descriptions, refer to Section 7.6 Date (8 Characters) 10.2 Signal Silence When the user sends a Signal Silence command (by pressing the F13 key and sending a ~M) to the AFP-200, the panel will respond with the following message string: @ALARM@SILENCED@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@HH:MMA@DAY@MM/DD/YY Note: For detailed field descriptions, refer to Section 7.6 Time Day of Week Date (8 Characters) 14

10.3 System Reset When the user sends a System Reset command (by pressing the F14 key and sending a ~N) to the AFP-200, the panel will respond with the following message string: @@@SYSTEM@RESET@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@HH:MMA@DAY@MM/DD/YY Note: For detailed field descriptions, refer to Section 7.6 Time Day of Week Date (8 Characters) 10.4 Manual Evacuate When the user sends a Manual Evacuate (Drill) command (by pressing Shift F13 which sends a ~Q) to the AFP- 200, the panel will respond with the following message string: @MANUAL@EVACUATE@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@HH:MMA@DAY@MM/DD/YY Time Day of Week Date (8 Characters) Note: For detailed field descriptions, refer to Section 7.6 15

Appendix A: AFP-200 Type Codes The following is a list of all the valid Type ID's for the AFP-200 Fire Alarm Control Panel. The Type ID's are listed under their respective categories. Detectors Monitor Modules Control Modules Panel Circuits 123456789012 123456789012 123456789012 123456789012 SMOKE(PHOTO) MONITOR RELAY BELL@CIRCUIT SMOKE@(ION) PULL@STATION STROBE@CKT STROBE@CKT HEAT(ANALOG) SMOKE@DETECT BELL@CIRCUIT HORN@CIRCUIT WATERFLOW HORN@CIRCUIT AUDIBLE@CKT SUPERVISORY AUDIBLE@CKT RELEASE@CKT TAMPER RELEASE@CKT REL@CKT@ULC NON@FIRE REL@CKT@ULC HAZARD@ALERT RELEA.@FORMC FIRE@CONTROL ABORT@SWITCH MAN.@RELEASE SILENCE SYSTEM@RESET EVACUATE PAS@INHIBIT TROUBLE@MON BURGLAR@ALA 16

Appendix B: AFP-200 Status Banners The following is a list of all the AFP-200 character strings that may appear in the point status/system trouble field of an 80-character message. Status Strings Point Trouble Strings System Trouble Strings 1234567890123456 1234567890123456 12345678901234567890 ON INVALID@REPLY GROUND@FAULT OFF DEVICE@DISABLED AC@FAIL NORMAL MAINTENANCE@REQ BATTERY ACTIVE DET@FAILED@TEST STYLE@6 ALARM: DRIFT@COMPENSATE OPTION@MODULE CLR@AL OPEN@CIRCUIT TERM.@SUPERVISION TROUBL SHORT@CIRCUIT ANNUN.@1@TROUBLE CLR@TB PREALM ANNUN.@2@TROUBLE ANNUN.@1@NO@ANSWER ANNUN.@2@NO@ANSWER EPROM@ERROR INTERNAL@RAM@ERROR EXTERNAL@RAM@ERROR PROGRAM@CORRUPTED NO@DEVICES@INSTALLED AVPS.@TROUBLE 17

Appendix C: European Mode Operation The AFP-200 Fire Alarm Control Panel may be programmed to operate in European mode. This selection is made in the system parameters section of programming (refer to the AFP-200 Instruction Manual) by changing the USA TIME banner to EUR TIME. Operating the AFP-200 in European mode affects certain 80-character message fields. European mode changes the 12-hour time format to 24-hour (military) time and changes the date display by placing the day before the month. In USA mode, the date appears in a format of MM:DD:YY. However, in EUR mode, the date appears in a DD:MM:YY format. Example: When the panel is operating in European mode, a time of 3:38 PM will be displayed as 15:38 and the date November 14, 1994 will be displayed as 14/11/94. In addition to time/day changes, European mode also affects two status banners in the 80-character messages. When the AFP-200 displays a trouble message, the character string TROUBL is replaced by the string FAULT as shown in the example below. FAULT@@SMOKE(PHOTO)@TECH.@PUBLISHING@@@@Z01@INVALID@REPLY@@@@15:38@@14/11/94@D42 When a device or zone is disabled, the AFP-200 will display a disable message and the character string DISABLED will be replaced by ISOLATED as shown below. FAULT@@SMOKE(PHOTO)@TECH.@PUBLISHING@@@@Z01@DEVICE@ISOLATED@@15:38@@14/11/94@D42 18