IECEx Certificate of Conformity

Similar documents
IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

DB5 Intrinsically Safe Sounder Type DB-5

srra, of Conformity IECEx Gert f cate ?-ot,b

IECEx Certificate of Conformity

Intrinsically Safe Solutions

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity


IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Intrinsically Safe Flame Detector Installation Guide

IECEx Certificate of Conformity

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

SET Installation and Operating Instructions. Level switch for one sensor

Certificate of Conformity

IECEx Certificate of Conformity

Certificate of Compliance

14300 MAINS SEPARATOR ALARM MANUAL

4) Intrinsic Safety Certification

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Tank Gauging System Special Safety Instruction

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

Inductive slot sensor

EU DECLARATION OF CONFORMITY

Installationsmanual GWSL1100/2100, GWML3100

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Universal Tank Alarm Type Installation, Operation & Maintenance

OilSET-1000 (12 VDC)

Rosemount 702 Wireless Discrete Transmitter

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

IECEx Certificate of Conformity

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

slra IEC of Gonformity IECEx Cert f cate ü* t4

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

RT FLOW RATE TOTALISER

User s Manual YTA610 and YTA710 NEPSI Certification

Technical Data. General specifications. Rated operating distance s n 5 mm

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

Solar Separator Alarm Type Installation, Operation & Maintenance

SET-2000 Oil/Sludge 12 VDC

Technical Data. Dimensions

Australian/New Zealand EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZ. Cerc1ficace ofconfor1221t:y. Issue No.: 6 Date oflssue:

E2S Datasheet v10a

Technical Data. Dimensions

SET-2000 Hi Level/Oil

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL (ATEX)

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

PEPPERL+FUCHS GmbH

FLASHLIGHT ANSI STANDARDS

Orbis IS Product Guide MAN 3041

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Annubar Flowmeter Series

FLASHLIGHT ANSI STANDARDS

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Intrinsic Safety Solenoid Valves :-

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Declaration of conformity

Technical Data. Dimensions

Flameproof Manual Call Points Series MCP

Manual Isolating Barrier D461R1 (Revision 01)

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No. : Status: Date of Issue: Applicant: IECEx BAS 07.0067 Current 2017-04-03 Eaton Electric Limited Great Marlings Butterfield Luton Bedfordshire LU2 8DL Page 1 of 4 issue No.:8 Certificate history: Issue No. 8 (2017-4-3) Issue No. 7 (2016-10-5) Issue No. 6 (2014-3-28) Issue No. 5 (2011-11 - 22) Issue No. 4 (2011-1-31) Issue No. 3 (2010-3-11) Issue No. 2 (2009-5-6) Issue No. 1 (2008-1-30) Issue No. O (2007-11- 12) Equipment: Optional accessory: MTL5511 / MTL5514 / MTL5514-T I MTL5516C I MTL5517 Switch I Proximity Detector Interface Type of Protection: Intrinsic Safety Marking: [Ex ia Ga] llc [Ex ia Da] lllc [Ex ia Ma] I -20 c s Ta s +60 C - MTL5511/14/16C/17 Models -20 c s Ta s +65 C - MTL5514-T Model only Approved for issue on behalf of the IECEx Certification Body: Position: Technical Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SGS Baseefa Limited Rockhead Business Park Staden Lane Buxton, Derbyshire, SK17 9RZ Unit~~ ingdom

Certificate No.: Date of Issue: Manufacturer: IECEx BAS 07.0067 2017-04-03 Eaton Electric Limited Great Marlings Butterfield Luton Bedfordshire LU2 8DL Issue No.: 8 Page 2of4 Additional Manufacturing location(s): MTL Instruments PVT Limited No 3 Old Mahabalipuram Road Sholinganallur Chennai India This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-11 : 2011 Edition: 6.0 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 11 : Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/BAS/ExTR07.0127/00 GB/BAS/ExTR 10.0296/00 GB/BAS/ExTR 16. 0238/00 GB/BAS/ExTR08. 0009/00 GB/BAS/ExTR11.0295/00 GB/BAS/ExTR17.0096/00 GB/BAS/ExTR 10. 0026100 GB/BAS/ExTR 14. 0065/00 Quality Assessment Report: GB/BAS/QAR06. 0022/06 GB/BAS/QAR07. 0017 /06

Certificate No.: IECEx BAS 07.0067 Date of Issue: 2017-04-03 Issue No.: 8 Page 3of4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The MTL551 1 I MTL5514 / -MTL5514-T I MTL5S16C I MTL5S17 Switch /Proximity Detector Interface are designed to restrict the transfer of energy from unspecified non-hazardous area apparatus to up to two intrinsically safe circuits by limitation of voltage and current. A transformer and relays provide galvanic isolation between the hazardous and nonhazardous area circuitry. Each channel of the interface monitors either a detector or switch located in the hazardous area and controls nonhazardous area loads via relays. Some models of the interface are fitted with independent phase reverse controls and Line Fault Detection (LFD) circuitry allow an alarm condition to be signalled for either state, set by switches on the side of the interface. The apparatus comprises an isolating transformer, relays, zener diodes and current limiting resistors to provide voltage and current limitation on each channel. These, together with other electronic components are mounted on a single printed circuit board and housed in a plastic enclosure. Polarised plugs and sockets are provided for connection to the hazardous and non-hazardous area. LED indication is provided to indicate Power-on, state of the outputs and LFD status. The above listed models are all built on a common printed circuit board. The differences between the models relate to the configuration of relays and non-hazardous area connections. The MTL5514-T Single Channel Switch I Proximity Detector Interface with Line Fault Detection (LFD) Alarm is of similar construction to the MTL5514 variant of the equipment with the same input and output parameters, but has an extended ambient temperature range. See annex for model and electrical data. SPECIFIC CONDITIONS OF USE: NO

Certificate No.: IECEx BAS 07.0067 Date of Issue: 2017-04-03 Issue No. : 8 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 8.1 To permit the addition of the MTL5514-T Single Channel Switch I Proximity Detector Interface with Line Fault Detection (LFD) Alarm to the range covered by the certificate. The MTL5514-T is of similar construction to the MTL5514 variant and has the same input and output parameters, but has an extended ambient temperature range of -20 C to +65 C. The Equipment Title, Marking section and Schedule was revised to detail the new variant of the equipment. The Certificate Annex (now Issue 3) was updated to list the new variant. ExTR: GB/BAS/ExTR17.0096/00 File Reference: 17/0165 Annex: IECEx BAS 07.0067 Annex Issue 3.pdf

SGS Baseefa Limited Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ ANNEX to IECEx BAS 07.0067 Issue No. 3 Date: 2017/04/03 MTL5511 / MTL5514 / MTL5514-T / MTL5516C / MTL5517 Switch / Proximity Detector Interface Model Range: Model No. MTL5511 MTL5514 MTL5514-T MTL5516C MTL5517 Single Channel Switch / Proximity Detector Interface Single Channel Switch / Proximity Detector Interface with Line Fault Detection (LFD) Alarm Single Channel Switch / Proximity Detector Interface with Line Fault Detection (LFD) Alarm Two Channel Switch / Proximity Detector Interface Two Channel Switch / Proximity Detector Interface with Line Fault Detection (LFD) Alarm Non-Hazardous Area Terminals 7 to 14 U m = 253V r.m.s. The circuit connected to non-hazardous area terminals 13 & 14 is designed to operate from a d.c. supply voltage of up to 35V. Non-hazardous area terminals 7 to 12 are connected to relay contacts which can switch up to 253V r.m.s, 2A r.m.s. and 100VA. Hazardous Area Terminals 1 w.r.t. 2 / 3 (Channel 1) Hazardous Area Terminals 4 w.r.t. 5 / 6 (Channel 2)* U o = 10.5V C i = 0 I o = 14mA L i = 0 P o = 37mW * For MTL5516C & MTL5517 Models only The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area load connected must not exceed the following values: GROUP CAPACITANCE INDUCTANCE OR L/R RATIO (µf) (mh) (µh/ohm) IIC 2.41 175 983 IIB** 16.8 680 1,333 IIA 75.0 1,000 1,333 I 95.0 1,000 1,333 ** Group IIB parameters also applicable for associated apparatus [Ex ia Da] IIIC Notes: 1) The above load parameters apply when one of the two conditions below is given: - the total L i of the external circuit (excluding the cable) is < 1% of the L o value or - the total C i of the external circuit (excluding the cable) is < 1% of the C o value. 2) The above parameters are reduced to 50% when both of the two conditions below are given: - the total L i of the external circuit (excluding the cable) is 1% of the L o value and - the total C i of the external circuit (excluding the cable) is 1% of the C o value. The reduced capacitance of the external circuit (including cable) shall not be greater than 1µF for Groups IIB, IIA & I and 600nF for Group IIC. Page 1 of 1