EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

Similar documents
EasyAir office sensor advanced grouping SNS200

Sensors. EasySense Outboard-Mount for High Bay

Sensors. EasyAir. office sensor advanced grouping SNS200. Design-in Guide. Single, compact, cost-effective luminaire control

Indoor Controls. SpaceWise SWZG2. Wireless technology

Fixture control made simple

Experience the future of lighting with SR

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Single, compact, cost-effective fixture control

Single, compact, cost-effective fixture control

Technical Application Guide

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Savings, control, and comfort without complexity

Tri-level Control HF Sensor

Tri-level Control Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Wireless High Bay Sensor (WHS100) Installation Instructions

Built-in HF Sensor for High Bay

VESICA LINEAR SUSPENDED VES L

SCS motion sensors Surface/wall mounting - PIR

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Vive PowPak Fixture Controls

Wireless Wall-Mount Sensor

, ,

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Detector switch - Dual Tech SCS

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

IP65 High Bay Dual Sense Sensor

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

performance PowerBalance, surface mounted Benefits Features Application Specifications

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LPCMPIRM65 & LPCMPIRDSI65

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Tri-level Control HF Sensor

CoreLine Waterproof the clear choice for LED

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

600 Watt Dimmer Install Guide

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Wireless Wall-Mount Sensor

Enhancing your petrol station with smart lighting

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Daylight harvest function to regulate light output for maintaining required lux level

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Smart Thermostat RDS110

LPC3BSP65 & LPC3BDP65

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Flexible, energy-efficient

SonoSelect and SonoSafe Energy Meters

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Installation Guide. Ceiling PIR Detector (311) Features and Connections

IP65 High Bay Dual Sense Sensor

E529 Smart Digital Thermostat Product Guide

TENOCHCA HALL - FAN COIL UNITS, RESTROOM AND FINISH RENOVATION PROJECT NO

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Integrated PIR detectors

Detector switch - Dual Tech

Ledinaire Batten Simply great LED

Wireless Wall-Mount Sensor

TX1 ArcMesh transmitter

Product Portofolio NODE W/ SENSOR SENSORS NODES RELAY SWITCHES STRUCTURE INFRA- LOG-RLY LOG-DR10V LOG-10V12 LOG-LBKO10V LOG-EBOX LOG-AP3 LOG-USB

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Tri-level Control HF Sensor

Maestro 0 10 V Dimmer Sensor

Installation instructions

Product Specifications Dialog Room Controller* (*patent pending)

Mini Product Guide.

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Connectivity Control Confidence

Manual & Technical Documentation V1.1

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

Optimal control for superior lighting performance

Fortimo LED Line Gen2 Module

1126 Series Ceiling Mount PIR Motion Detector

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Fitting instructions

Applied Lighting Controls

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

A flexible and affordable retail toolbox

East Central College

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

False Ceiling HF Sensors

ArenaVision LED gen2 enabling sports venues to offer a new. experiences. ArenaVision LED gen2. Benefits. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Transcription:

Sensors EasyAir SNH200 Datasheet EasyAir SNH200 EasyAir SNH200 is the ideal solution for per-fixture control of new light luminaires for high bay applications. It combines occupancy sensing, daylight harvesting and task tuning in a single package for easy assembly in OEM luminaires or installation in the field. EasyAir operates with the established Philips Xitanium SR LED driver standard of a simple two-wire connection between the sensor and the driver, thus eliminating the need for multiple components and auxiliary devices. The result is a cost-effective and easy-to-design-in solution ideal for energy-savings. An intuitive app for Android smartphones allows quick and easy configuration and commissioning during and after installation. EasyAir includes advanced grouping functionality which enables occupancy sharing and zoning capability. Up to 40 sensors can be operated together in a single group, and the group can then be divided into a maximum of 6 zones. With this advanced functionality, the group can be programmed such that a zone comes up to full light level upon motion detection while other zones dim up to a lower background light level. This enhances energy savings while still providing lighting in adjacent areas. EasyAir SNH200 does not require gateways, network connections or dashboards. The sensors in the group communicate to each other via Zigbee for simple area-based control. It is an uncomplicated means to achieve energy savings in industrial high bay applications while maintaining aesthetics in the space. May 2018

Features Occupancy sensing, daylight harvesting and task tuning in one device Occupancy sharing, 40 sensors max per group, 6 zones max per group 2-wire connection, with Xitanium SR drivers or SR bridge Operates with Philips Xitanium SR LED drivers and qualified wireless switches Configuration of sensor parametersif desired - using NFC or IR Philips Field Apps, available on Google PlayStore for free 5m to 16m mounting height; IP65 rated Benefits Combines functionality to reduce need for multiple components Quick task tuning in the field to optimize light and power levels Cost-effective solution for energysavings and code-compliance strategies 5-year limited system warranty with Philips Xitanium LED drivers Configuration and commissioning from the floor Applications Warehouses Assembly areas Cold storage Ordering data Commercial product name Description EOC 12NC MOQ EasyAir SNH200 industry sensor advanced grouping 8718696 748541 00 9290 016 25706 20 pcs IR Dongle Mandatory infrared accessory for grouping and configuring from floor level 8718699 611811 00 9290 016 51106 1 pc Product Data Physical Information Overall Dimensions Refer to drawing Housing (Luminaire Hole) M20 threaded nipple for M20 knockout Net Weight per Piece 185gm Color Light gray housing (RAL7035), translucent cover Wiring (2) 18AWG wires, unpolarized; 60cm length; 8mm strip length Electrical Information Input Voltage Powered by SR driver low voltage interface Current Consumption 45mA peak and 15mA at 15V (average) Nominal Power Consumption 200mW (average) Occupancy Sensing Type Passive infrared (PIR) Enable/Disable Enabled by default Occupancy Mode Auto-on/auto-off; Manual-on/auto-off ; Manual-on / manual-off Group Occupancy Sharing Enabled/disabled Group Lighting Behavior Background level/task level Hold Time 2 minutes - 60 minutes Viewing Angle ±30 Background Light Level 0% - 100% Prolong Time 0 minutes - 150 minutes, or infinite Grace Fading 0 seconds - 25 seconds Response Time/Fading to Switch On/Off 0.7 seconds Daylight Sensing Enable/Disable Disabled by default Auto-Calibration Upon power-up; disabled when daylight sensing is disabled Viewing Angle +/- 10 Task Tuning Full Light Setting 5% - 100% 2-11 Datasheet - EasyAir SNH200 May 2018

Environment & Approbation Operating Ambient Temperature Range Ingress Rating Operating Humidity Storage Temperature Max Case Temperature (Tcase) Agency Approbations Warranty Digital Interface Other -30 C to +65 C Tested for compliance to IP65 by Dekra 20% to 85% relative humidity -30 C to +80 C +65 C CE, ENEC, RED, EMC 5 years Xitanium SR Wireless Protocol Zigbee, IEEE 802.15.4 Encryption No. SR Drivers per Sensor Max Distance Switch-to-First Sensor Max Distance Sensor-to-Sensor No. Sensors per Group No. of Zones per Group No. Sensors per Zone No. Switches per Group/Sensor Mounting Height Field Configuration AES-128 4 max. 15m line-of-sight 15m line-of-sight 40 max. 6 max. 40 max. 5 max. 5m to 16m via NFC or IR, parameters set via Philips Field Apps; Configuration via IR requires a specific IR dongle available via Philips Compatible LED Drivers Logistic code 12NC Description 9290 015 40806 Xitanium 100W 0.15-0.5A 300V SR 230V ixt 9290 015 40906 Xitanium 150W 0.2-0.7A 300V SR 230V ixt 9290 015 05006 Xitanium 75W 0.7-2.0A 54V SR 230V 9290 015 07706 Xi SR 75W 0.2-0.7A SNEMP 230V S240 sxt 9290 015 07806 Xi SR 75W 0.3-1.05A SNEMP 230V S240 sxt 9290 015 07506 Xi SR 150W 0.2-0.7A SNEMP 230V S240 sxt 9290 015 07606 Xi SR 150W 0.3-1.05A SNEMP 230V S240 sxt Specifications available at www.lighting.philips.co.uk/oem-emea/support/technical-downloads 3-11 Datasheet - EasyAir SNH200 May 2018

Sensor Dimensions (mm) 40 43 +1-0 30 14 +0.5-0 M20x1.5 ø115 +1-0 63 86 60 21.5 NFC antenna (side) RF antenna (side) RF receiver Daylight sensor LED indicator and Occupancy sensor (PIR) 4-11 Datasheet - EasyAir SNH200 May 2018

Wiring Diagram Connectors EasyAir SR SR (2) 18AWG wires, non-polarized Overall length 60cm Strip length 8mm LED+ LED+ LED- LED- RSET2 SGND SR- SR+ GROUND LINE NEUTRAL NC XITANIUM SR LED DRIVER NFC ANTENNA Note: Above depicts connecting wires from sensor to Xitanium SR drivers that include connectors. For connection to Xitanium SR drivers that include leads, use wirenuts suitable for 18AWG solid wire. 5-11 Datasheet - EasyAir SNH200 May 2018

Occupancy sensing detection patterns The plots below show the top and side view of the occupancy coverage based on NEMA test, an industry standard. In the side view, it is visible that coverage ratio of mounting height: diameter at ground level is at maximum 1:1. For example if the mounting height is 12m, the maximum diameter coverage is 12m. Disclaimer: 1. In these plots, the white areas are blind spots and the detection is based on subject s motion. An idle subject may not continue to trigger occupancy detection once the hold time expires. 2. As PIR based sensing works on temperature difference between the subject and the ground level, the occupancy detection could vary due to clothing and size of subject. Position (m) 10 8 6 4 2 Top view Mounting Height (m) 0 2 4 6 Side view Max. height - 16m 0 8-2 10-4 -6 12-8 14-10 -10-8 -6-4 -2 0 2 4 6 8 10 16-10 -8-6 -4-2 0 2 4 6 8 10 Position (m) Horizontal position (m) Max. coverage - 16m Warning: Place heat radiating devices outside of the monitoring cone. Avoid drafts (e.g. from ventilators or heating systems). 6-11 Datasheet - EasyAir SNH200 May 2018

Occupancy Sensing (continued) Full-On Sequence Field Task Level = 100% Hold Time (configurable) Grace Fading (configurable) Light Level Background light level (configurable) Fading to Switch On (fixed) Prolong Time (configurable) T1 T2 T3 T4 T5 T6 T7 Fade to Switch Off (fixed) Switch On Sequence Switch Off Sequence 7-11 Datasheet - EasyAir SNH200 May 2018

Daylight Sensor The light sensor measures the total amount of light with an opening angle of 10 whereas PIR has 30, all calculated from normal. The following aspects should be observed during installation: Minimum distance from the window - refer below graph Prevent light reflections from outside entering the sensor (for example sunlight reflection from a car/truck bonnet) as this will lead to incorrect light regulation. As a guideline the formula 0.174 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the top of the window to the ceiling. Photosensor spatial reponse Minimum distance versus mounting height Wall Sensor distance to window Window SNH200 Sensor height (H) with respect to window Minimum distance from window [meters] 3,0 2,5 2,0 1,5 1,0 0,5 0,0 0 2 4 6 8 10 12 14 16 18 20 Floor Sensor mounting height with respect to window [meters] Photosensor spectral response Output current (Normalized) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 200 300 400 500 600 700 800 900 1000 ALS Human Eye Wavelength (nm) 8-11 Datasheet - EasyAir SNH200 May 2018

Philips Field Apps: EasyAir NFC and EasyAir Industry IR Note: Use of IR requires from IR Dongle from Philips to configure and group from floor level. EasyAir parameters can be configured via Philips Field Apps available in Google PlayStore. For list of supported phones, please visit our website. 1. EasyAir NFC This app allows configuring EasyAir parameters only when you can physically access the sensor with a smartphone, making use of near field communication (NFC) technology. 2. EasyAir Industry IR - This app allows commissioning (grouping and zoning) of sensors. It is also possible to add switches or configure sensor settings via this app using Android phone and specific IR device from Philips Lighting. Philips Field Apps can be downloaded for free from Google PlayStore. The user needs to register on our portal to receive username and password. Refer to app manual on our website for more details. Default Factory Settings Occupancy based control Auto-on, Enabled Daylight Based Control Auto-on, Disabled Daylight dependent switching Default disabled Daylight dependent override Default disabled LED Indicator Enabled Occupancy Mode Auto-on/off Group Occupancy Sharing Enabled Group Light Behaviour Background level Field Task Tuning 100% Background Light Level 20% Hold Time 15 minutes Prolong Time 15 minutes Grace Fading 10 seconds Fade to Switch On 0.7 seconds Fade to Switch Off 0.7 seconds 9-11 Datasheet - EasyAir SNH200 May 2018

IR Dongle EasyAir SNH200 can be commissioned and configured through InfraRed (IR) technology. To achieve high heights upto 16m with minimal interference, it is mandatory to use the IR Dongle accessory available via Philips. Ensure that you stand and point from right under the sensor to avoid interference with neighbouring sensors. For support, consult your Philips representative. Luminaires Advise on installer s positioning for correct commissioning of SNH200 using IR Dongle Configuration via Mobile App EasyAir parameters can be configured via Philips Field Apps available for Android phones. It is mandatory to use IR dongle with an Android phone for commissioning and configuration of SNH200. Two options are available: 1. EasyAir NFC This app allows configuring EasyAir parameters only when you can physically access the sensor with a smartphone. The correct functioning of this app is strongly dependent on the strength and placement of NFC antenna within the Android phone*. 2. EasyAir Industry IR This app allows configuring EasyAir parameters plus enables grouping to a wireless switch, which can be done with an Android phone and a specific IR dongle* from Philips. * Note: Please refer the list of recommended phones on our website for details on NFC and IR support per Android phone. You must first register for Philips Field Apps to receive a username and password, then download Philips Field Apps from the Google Play Store. Refer to www.lighting.philips.co.uk/oem-emea/products/ easy-to-integrate-wireless-sensors for details, including recommended Android phones and app manual. Compliance to Radio Equipment Directive (RED) The Directive ensures a single market for Radio and Telecommunication Terminal Equipment by setting harmonized standards for safety and health, electromagnetic compatibility and the efficient use of the radio spectrum. This applies to all products using the radio frequency spectrum. This device is compliant to the underlying harmonized standards which is verified by an independent Notified Body. Any changes or modifications not expressly approved by Philips could void the user s authority to operate this equipment. This product is intended for commercial use only. Hereby, Philips Lighting declares that the radio equipment type EasyAir is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity and technical information is available on the website: http://www.lighting.philips.co.uk/oem-emea/support/technical-downloads 10-11 Datasheet - EasyAir SNH200 May 2018

Disclaimer 2018 Philips Lighting Holding B.V. All rights reserved. This document contains information relating to the Philips Lighting portfolio, intended for companies who may be interested in developing their product offering. Note that the information provided is subject to change. Philips Lighting does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. 2018 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. www.lighting.philips.co.uk/oem-emea/ support/technical-downloads 05/2018 Data subject to change