Yale University Design Standards

Similar documents
DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

DOMESTIC WATER PACKAGED BOOSTER PUMPS

A. Section Joint Sealants: Seal fixtures to walls and floors.

University of Rochester October 17, 2008 Brooks Landing Business Center

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

Union County Vocational - Technical Schools Scotch Plains, New Jersey

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

GENERAL PLUMBING REQUIREMENTS

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Mechanical Inspection Plumbing

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

SECTION PLUMBING FIXTURES

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

GENERAL PLUMBING REQUIREMENTS

GARCIA GALUSKA DESOUSA Consulting Engineers

DESIGN GUIDELINES AND TECHNICAL STANDARDS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

2016 Plumbing Supplemental Plan Review List

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

A. This Section includes the following domestic water piping specialties:

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

Design and Construction Standards SECTION PLUMBING EQUIPMENT

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

Read Only Document Not For Distribution

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION PLUMBING EQUIPMENT

MATERIALS Traps TRAPS. No. IPC IRC Description

SECTION PLUMBING EQUIPMENT

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

Read Only Document Not For Distribution

Sanitary Drainage Systems

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

SECTION PLUMBING

CONTENTS. B. System Design and Performance Requirements

GENERAL PLUMBING REQUIREMENTS

PLUMBING REQUIREMENTS

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

PLAN REVIEW SUBMITTAL GUIDE

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

Plumbing and Drainage

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS July 2011

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

A. This Section includes the following emergency plumbing fixtures:

PLUMBING FIXTURES CHAPTER 27

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:

JAMES P. KISSANE, ARCHITECT

SECTION STEAM CONDENSATE PUMPS

University of New Hampshire Scholars' Repository

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

Plumbing Guidelines 2012 IBC/ANSI A

BSD Technical Standard. Division 22: Plumbing

PHCC Educational Foundation Plumbing Year 4

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

SECTION PLUMBING SPECIALTIES

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

DESIGN CRITERIA See Part II for additional information regarding Energy and Water Efficiency, etc.

NYC Department of Education

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Mechanical/Plumbing Specification

PLUMBING INSTALLATIONS

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

CONTENTS. B. System Design and Performance Requirements

FEATURES. Other Fed-Flush Arrangements

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

NYC Department of Education

Gulfport, Mississippi 21 May 2007

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

NYC Department of Education

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Special Requirements For Health Care Facilities

SECTION ELECTRIC WATER HEATERS

Work Order Number PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20

NYC Department of Education

PRICE BOOK CONTENTS 010 PIPE

Level I Chapter 1 Worksheet

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Transcription:

Change History Date Description of Change Pages / Sections Modified Change Approver Initials 3/26/13 Add text encouraging discussion of innovation in 2 15410, A (Summary) SO newly available products. 3/26/13 Add to item: Dual flush Toilet/ flush valve 6 15410, B. #4b.(Fixture Types, SO Water Closets) 3/26/13 Add check valves on hot and cold water supply lines to 6 15410, C, #1 (Plumbing Fixtures, SO faucet to avoid short circuiting through faucet. Add hose bib and r.p backflow preventer for cleaning station Manufacturers, Faucets) 3/26/13 Add to both items: Add check valves on hot and cold 6-15410, B, #4 & #5 (Plumbing SO water supply lines to faucet. Add hose bib and r.p backflow preventer for cleaning station. Fixtures, Manufacturers, Janitor s Sink & Mop Basin) 3/26/13 Add to item: Dual flush Toilets - flush valve 10 15140, C #16. (Manufacturers, SO Flush valves) 3/26/13 Add 2 nd paragraph: re. combined bottle filler feature. 15-15415, C. (Drinking Fountains SO and Water Coolers, Product Standards) 3/16/13 Remove Tiger Flow from list 20-15441, E, #3 (Manufacturers, SO Add Grundfos to the list City and Hot Water Pressure Booster Pumping Systems) 3/26/13 Add Maxi-Therm to the lists for both. 28 15480, E #1 & #2 (Manufacturers, Gas Domestic Water Heaters, Gas & Electric) SO Subdivision 15400: Plumbing Fixtures and Equipment 1

Section 15410: Plumbing Fixtures 15410 Plumbing Fixtures This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Manufacturers D. Quality Control This section contains design criteria for plumbing fixtures, including faucets and flush valves. We encourage use of innovative new products: When designers want to use new products, they are required to present to Yale Utilities and Engineering for discussion, review and approval. B. System Design and Performance Requirements Design the plumbing system for safety, longevity, durability, and flexibility. Provide thermostatic mixing and pressure balancing valves for all baths and showers. 1. Fixture Quantities (General) Yale University will tolerate under-fixturing on individual floors or in specific building areas only if horizontal or vertical occupant access to fixtures in other areas is sensible. a. Base quantities on the anticipated maximum, normal-use bui1ding capacity. b. Quantities must be satisfactory to code-enforcing officials and/or funding agencies. Use the quantities listed in Table 1 as a guide for preliminary planning. Subdivision 15400: Plumbing Fixtures and Equipment 2

Section 15410: Plumbing Fixtures c. For all new or remodeled building construction, the aim is to satisfy anticipated demand. However, avoid over-fixturing because of the comparatively high cost of these facilities and spaces. d. When comparing proposed quantities to codes or other required standards, be aware that codes and standards usually apply to fixture totals for an entire single-type occupancy building. Therefore, fixture quantities on each floor of such a building need not necessarily meet codes or standards. 2. Fixture Quantities Verify fixture quantities as specified by state and local building codes. a. Office Buildings The OSHA quantities for water closets and urinals listed in Table 1 are satisfactory. Table 1. Fixture Quantities Water Closets, Lavatories, and Urinals Men Women Men & Women Persons WCs Urinals WCs Persons Lavatories 1-5 1 0 1 1-15 1 6-15 1 0 1 16-36 2 16-35 2 0 2 31-60 3 36-55 2 1 3 61-90 4 56-80 3 1 4 91-125 5 81-110 4 1 5 126-170 6 111-150 4 2 6 171-205 7 151-190 5 2 7 Subdivision 15400: Plumbing Fixtures and Equipment 3

Section 15410: Plumbing Fixtures b. Research Buildings Per code, fixture quantities should be the same as for office buildings, but only if it is anticipated that all occupants will be in the building as constantly as occupants of an office building. If the building program does not define this constancy, it must be determined for its effect on fixture quantities. If proposed quantities are less than the code requirements, a code exception will be investigated. c. Places Of Assembly Designers may recommend fixture quantities in places of assembly. See the applicable code for minimum requirements. However, provide no less than two of each type of fixture in any one toilet room. d. Libraries Per code, a library, depending on its type, could fall into either the same category as an office building or in the public or semi-public building category. Evaluate each library according to its type and category. Some small libraries can be categorized as classrooms. A large library, such as Sterling Memorial, could fall into a category not covered by code. As a guide for such a separate category, about one sanitary fixture (water closet or urinal) per 50 reader seats (and about the same number of lavatories) should be adequate, if facilities for staff are considered separately. A proposal involving such a separate category should be approved by code or funding authorities prior to incorporation into a building. e. Classroom Buildings Yale University does not yet have an inventory of fixtures (and adequacy of same) in its classroom buildings. Until such an inventory is available, use Table 2 as a guide. The number of fixtures must be approved by code or funding authorities before incorporation into a building. However, unless the anticipated use by either sex is nominal (under 25), provide at least two of each fixture for each sex. Subdivision 15400: Plumbing Fixtures and Equipment 4

Section 15410: Plumbing Fixtures Table 2. Classroom Fixtures Men Women Fixture Type Student Stations per Fixture WCs 100 Urinals 110 Lavatories 150 WCs 60 Lavatories 100 f. Other Building Types If fixture quantities are not stated in the building program for other types of buildings, base the quantities on modifications of those developed by the architect and approved by Yale University and code or funding authorities for the types of buildings listed above. g. Counting Fixtures for the Handicapped Include all fixtures provided for the physically handicapped in the fixture count. Wherever "unisex" toilet rooms are used, apply each WC as a deduction from the combined requirement for both sexes before apportioning the remaining needs among such gang toilet rooms as might be designated for each sex. Unisex toilet rooms are preferred, where feasible, for this use. 3. Mounting of Fixtures Hang fixtures on walls wherever possible. Use chair hangers or (as for a battery of lavatories) a less expensive substitute. 4. Fixture Types a. Lavatories Yale University prefers vitreous china lavatories with integral back and front faucets. The minimum size is 20" W x 18" outside. Space is 26" o.c. Subdivision 15400: Plumbing Fixtures and Equipment 5

Section 15410: Plumbing Fixtures b. Water Closets Water closets must be elongated, siphon-jet action, with open front white seats. Include flush valves where feasible and specify dual-flush flush valves where appropriate. c. Urinals Urinals (men only) must be vitreous china, siphon-jet action, with flush valves. For standards of quality, see the manufacturers and model numbers listed below under Manufacturers. 5. Plumbing Fittings For lavatory faucets, use fittings that are not self-closing. C. Manufacturers Yale University requires the use of low flow plumbing fixtures. The flush valves for toilets and urinals must be manufactured by the China Manufacturer. The model numbers for low flow fixtures and flush valves must be compatible. Provide the model numbers for all flush valves for toilets and urinals on the shop drawings for the project. Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. Faucets Symmons S-90-2-G-FR for a regular sink, with a centerset single lever, extra-long wrist operation, and grid strainer assembly. S-90-2-G-FR-W for a handicapped sink, with a 4" centerset single lever, extra-long wrist operation, and grid strainer drain assembly. S-93-2 for a kitchen sink with a hose spray. Speakman SC-5772 for a kitchen sink, with a hose spray and an 8" deck fitting. SC-5811 for a mop basin, with an 8" faucet center. Provide integral check valve on hot and on cold water supplies to mop sink faucet. SC-5811-RCP for a slop sink, with an 8" faucet center. Provide integral check valve on hot and on cold water supplies to slop sink faucet. Subdivision 15400: Plumbing Fixtures and Equipment 6

Section 15410: Plumbing Fixtures Moen 4420 Kohler Triton T&S No. B-720 POL cold water hose bib for cleaning solution system. Provide with reduced pressure backflow preventer WATTS No. 909. American Standard 2. Metering Faucets Symmons S-61-G Kohler S-60-G (for a regular sink temperature selection and 4" centerset grid strainer drain assembly) T&S Laboratory 3. Shower Valves Symmons 4-500-X Symmons 1-500, for PWG 4. Angle Stops Brasscraft Furiyne Ansonia (Teledyne) A-200 series 5. Janitor s Sink Kohler K-6718, (wall hung K-6673 trap standard adjust for 3" IPS connect c.o. plug strainer s.s. rim guard, black back) American Standard 7692.023 Provide check valve on hot and cold water supplies to Janitor s sink faucet. Provide cold water hose bib T&S Brass No. B-720-POL and reduced pressure backflow preventer WATTS No. 909 for cleaning solution system. 6. Mop Basin Fiat MSB-3624, 36" x 24" x 10" with shelf MSB-2424, 24" x 24" x 10" without shelf Subdivision 15400: Plumbing Fixtures and Equipment 7

Section 15410: Plumbing Fixtures Provide check valve on hot and cold water supplies to mop basin faucet. Provide cold water hose bib T&S Brass No. B-720-POL and reduced pressure backflow preventer WATTS No. 909 for cleaning solution system. 7. Dorm Sinks Kohler K-6718 American Standard 7692.023 8. Dorm Sinks-Cast Iron, Enamel Kohler K-2861 American Standard 4869.012 (dorm sink, wall mount 19" x 17" with 4" faucet center) 9. Dorm Sinks a. Kohler K-6562 (counter top bar) K-2904 (counter top 4") K-2900 (counter top) K-5964 (kitchen single) K-5965 (kitchen single) K-5961 K-3283 b. American Standard 7185.803 (sink 3 hole drill) 3303.00 (faucet center) 3211.000 (4" faucet center metal frame) 7024.804 (basin, 4 hole or drillings, 7172.804) 7024.803 (basin, 3 hole or drillings, 7172.803) 7172.803 or 7024.803 (kitchen single, basin 3 hole drillings) ELKAY PSR-3322-4 (kitchen double basin, 4 hole drillings) Subdivision 15400: Plumbing Fixtures and Equipment 8

Section 15410: Plumbing Fixtures 10. Dorm Sinks, Vitreous China, Handicapped a. Kohler K-12636 (handicapped sink) K-2032 (handicapped sink) K-2054 (handicapped sink) b. American Standard 9141.011 (wall mount 27" x 20" with 4" faucet center) 0355.012 (wall mount, back splash, 4" faucet center concealed arm carrier) Wall mount to back splash 4 faucet center concealed arm carrier 11. Urinal, Vitreous China, Regular Use and Handicapped Kohler K-4985 (regular use) American Standard 6561-017 (wall-mount, siphon-jet action, 3/4" top spud inlet, 2" IPS outlet) Kohler K-5014-T (handicapped) American Standard 6541.132 (regular use, wall mount, siphon-jet action, 1/4" top spud inlet, 2" IPS outlet) 12. Toilets, Wall Mount Kohler K-4430-ET (wall mount) American Standard 2257.103 (3.5 gallon) 13. Water Closet, Vitreous China; Regular Use and Handicapped Kohler K-4430-ET (regular use) American Standard 2257.103 (handicapped use, water saving siphon-jet action, 2-1/2" passageway, 1-1/2" top spud) Kohler K-4250 (regular use, floor mount, water-saving siphon-jet action, 2-1/2" passageway, 1-1/2" top spud, 10" 12" roughing in) Kohler K-3420-ET (regular use) American Standard 2234.015 (floor mount, tank type, 1-3/4" passageway, 3/8" IPS water supply, 12" roughing in) Subdivision 15400: Plumbing Fixtures and Equipment 9

Section 15410: Plumbing Fixtures Kohler K-3527-EB (handicapped) American Standard 2216.143 (3.5 gallon use, floor mount tank type, 18" high bowl, 3/8" IPS water supply, 10" roughing in) Kohler K-4268 (handicapped) American Standard 3043.102 (regular use, floor mount siphon-jet action, 18" high bowl, water saving, 2-3/4" passageway, 1-1/2" top spud, 12" roughing in) 14. Toilet Tank 15. Tubs Kohler K-2867 Kohler K-4250 (floor mount) Kohler K-4330 (wall hung) Kohler K-4350ET (floor bolted) Kohler, K-3420EB (floor bolted) American Standard 2234.015 (3.5 gallon) 16. Flush Valves Sloan 186 Royal (for regular urinal, 3/4" IPS angle stop, coupling for 3/4" top spud, 1 to 1-1/2" high) Sloan Royal 180 (for handicapped urinal, 1" IPS angle stop, coupling for 1-1/4" top spud, 11-1/2" high) Sloan Royal (for regular and handicapped water closet, 1" IPS angle stop, coupling for 1-1/2" top spud, 11-1/2" high) Sloan Uppercut WES-111 Dual Flush (for regular and handicapped water closet, 1 I.P.S angel stop, coupling for 1-1/2 top spud, 11-1/2 high) 17. Lab Faucets Chicago 876-F3CP-VP Speakman SC-3004 Moen S0003 (spout only, 8132 handles only) Subdivision 15400: Plumbing Fixtures and Equipment 10

Section 15410: Plumbing Fixtures D. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 11

15412 Emergency Plumbing Fixtures This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Product Standards D. Manufacturers E. Installation Guidelines F. Quality Control This section contains design criteria for emergency eyewash and shower units. B. System Design and Performance Requirements 1. Design the plumbing system for safety, longevity, durability, and flexibility. 2. Provide a tempered water supply for all emergency showers and eyewashes. 3. Eyewashes must be full-face. C. Product Standards Products shall conform to ANSI-358.1 standards. D. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. Emergency Showers Speakman Symmons 2. Emergency Eyewash Units Haws Subdivision 15400: Plumbing Fixtures and Equipment 12

Section 15412: Emergency Plumbing Fixtures E. Installation Guidelines 1. Install the floor drain beneath the emergency shower. 2. Verify that tempered water has been specified for emergency fixtures. 3. In conjunction with code and standard requirements, emergency showers must be located in adjacent corridors or at the hazard room door exits. The showers are to be accessible, require not more than 10 seconds to reach, and be within a travel distance of no greater than 50 ft from the hazard rooms. 4. Provide emergency showers and eyewash fountains for: Laboratories Boiler rooms Cooling towers Chemical treatment areas Deionizing acid regenerant tank Battery charging rooms Provide additional emergency showers and eyewash fountains in other areas that: have hazardous materials that will be used in the area, and have no other emergency showers and eyewash fountains located within 50 feet of the area. 5. Provide full-size ball valves to isolate emergency showers or eyewash fountains. Lock the valves in the open position. F. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 13

15415 Drinking Fountains and Water Coolers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Product Standards D. Manufacturers Stainless Steel Water Coolers E. Quality Control This section contains design criteria for drinking fountains and water coolers. B. System Design and Performance Requirements Design the plumbing system for safety, longevity, durability, and flexibility. 1. Fixture Quantities (General) Yale University will tolerate under-fixturing on individual floors or in specific building areas only if horizontal or vertical occupant access to fixtures in other areas is sensible. a. Base quantities on the anticipated maximum, normal-use bui1ding capacity. b. Quantities must be satisfactory to code-enforcing officials and/or funding agencies. c. For all new or remodeled building construction, the aim is to satisfy anticipated demand. However, avoid over-fixturing because of the comparatively high cost of these facilities and spaces. d. When comparing proposed quantities to codes or other required standards, be aware that codes and standards usually apply to fixture totals for an entire single-type occupancy building. Therefore, fixture quantities on each floor of such a building need not necessarily meet codes or standards. Subdivision 15400: Plumbing Fixtures and Equipment 14

Section 15415: Drinking Fountains and Water Coolers 2. Fixture Quantities Verify fixture quantities as specified by state and local building codes. C. Product Standards Products must conform to ANSI/NSF 61 standards. D. Manufacturers Stainless Steel Water Coolers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: Halsey Taylor Elkay Oasis E. Bottle Filling Stations Where ever possible, water coolers are to be specified with a bottle filling station, like Halsey Taylor s HYDROBOOST, Elkay s EZH2O and Oasis s Aqua Point. F. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 15

15430 Plumbing Specialties This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Manufacturers D. Installation Guidelines E. Quality Control This section contains design criteria for water and drainage piping specialties, including backflow preventers, vacuum breakers, mixing valves, water hammer arrestors, and domestic water meters. B. System Design and Performance Requirements 1. Before design commences, professionals shall contact local water authority for complete requirements. 2. Design the plumbing system for safety, longevity, durability, and flexibility. 3. Install an approved, reduced-pressure, double-check type valve in both the potable and non-potable water supplies. a. Only potable water must supply drinking fountains, lavatories, sinks, janitor closets, safety showers, eyewash stations, and water heaters. b. Non-potable water or potable water is to must supply fire protection systems, toilets, urinals, fume hoods, laboratory sinks, outside hose bibs, and other supplies not for human consumption. c. A check valve must be installed upstream from the reduced-pressure valve to prevent valve dumping every time the main line pressure drops. d. Provide isolation valves between potable water and non-potable water. e. Identify and label gray-water systems. Subdivision 15400: Plumbing Fixtures and Equipment 16

Section 15430: Plumbing Specialties C. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. Mixing Valves Speakman Symmons 2. Water Hammer Arrestors Wade JMJ Cord 3. Backflow Preventers Watts D. Installation Guidelines 1. Where reduced-pressure backflow preventers are installed, install a floor drain nearby that will accommodate the full flow from the backflow preventer emergency dump port, if the valve malfunctions. 2. Install a hose bib at least every 100 ft around a building and in the mechanical room. Install a non-freeze type hose bib on the roof, near the air handling units. 3. Use trap primers only when necessary. Install them in accessible locations for maintenance. E. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 17

15441 Domestic Water Pumps This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Submittals D. Product Standards E. Manufacturers F. Materials G. Accessories or Special Features H. Special Requirements Source Control I. Quality Control Testing J. Installation Guidelines K. Quality Control This section includes design criteria for inline, end suction, and water pressure boosters for domestic water pumping systems. B. System Design and Performance Requirements 1. Provide a three-pump system for water booster pumping. Size one pump for approximately 1/3rd of the total water demand. Size each of the other two pumps for approximately two-thirds of the total water demand. Design the system so the smaller pump will run constantly until the water demand exceeds the capacity of the pump, at which point the smaller pump will stop and one of the large pumps will start. When the water demand exceeds the capacity of the larger pump, the smaller pump will automatically restart and operate together with the larger pump to provide the total water demand. The third pump will act as a standby pump. The pumps must be free of cavitation over their operating range. 2. The system must be controlled by a combination of flow or pressure switches and pressure-regulating valves, and must be designed to prevent water hammer. 3. Provide pressure gauges for every pump. 4. Specify that piping and pumps be installed and connections aligned, but not madeup, until inspection by Yale University. All piping must be supported independently of the pumps. Subdivision 15400: Plumbing Fixtures and Equipment 18

Section 15441: Domestic Water Pumps 5. In-line, end-suction, and split-case pumps bearing frame and pump internals must be serviceable without disturbing motors or connected piping. 6. Select pumps for an impeller diameter not greater than 90 percent of the maximum pump impeller diameter. 7. Select pump motors to be non-overloading at any point along the pump impeller curve or in combination with other pumps. 8. Provide pressure gauges for every pump, except small so-called boosters" which must have gauge cocks only. 9. Select pumps between 65% and 115% of best efficiency point along the impeller curve. 10. Consider a storage tank to reduce the number of pump starts. C. Submittals Submit the following construction and certification documentation. 1. Construction Documents Submit the following test reports: Installed pump performance test and balance report. Pump alignment report. 2. Product Certificates Signed by Manufacturer Specify that pumps be inspected by the manufacturer's authorized representative who must submit a written report to the engineer with a copy to Yale University stating that the pump has been properly installed, is operating correctly, and the installation is acceptable to the manufacturer in every respect. D. Product Standards Products must conform to the following standards: Hydraulic Institute standards ASME PTC 8.2 and 9 CSA standards UL Motor-Operated Water Pumps Standard Subdivision 15400: Plumbing Fixtures and Equipment 19

Section 15441: Domestic Water Pumps E. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. In-Line Pumps Bell & Gossett Taco 2. Booster Pumps Circulator Bell & Gossett (lubricated bearing with oil seals) Taco (sealed bearing) 3. City and Hot Water Pressure Booster Pumping Systems Bell & Gossett (multiple control panel, 2-3 pumps with small tank) Canaris Corporation Grundfos 4. Suction Diffuser Bell & Gossett Taco F. Materials All wetted parts in recirculation hot water pumps and in-line boosters must be of bronze construction (bronze impellers only). G. Accessories or Special Features 1. Couplings Couplings must be approved by the Yale University Facilities group. 2. Strainers 1. For water service, strainers must be the same size as entering pipe size and have a maximum clean pressure drop of one psig. 2. Use pump startup strainer screens for cleaning, and remove them afterwards. Subdivision 15400: Plumbing Fixtures and Equipment 20

Section 15441: Domestic Water Pumps 3. Provide a blow-off valve, full size full port ball valve on each strainer. Where feasible and permitted by code, blow-off piping must have plug. 4. Strainer material for use in domestic water systems must be of stainless steel construction. H. Special Requirements Source Control The manufacturer must maintain an inventory of all wearing parts within 50 miles of New Haven, CT. I. Quality Control Testing After factory assembly, the packaged pumping system must be hydrostatically tested and undergo a complete electric and hydraulic test from 0 to 100% design flow at the factory. All controls, pump sequencing devices, alarms and instrumentation must be tested and calibrated for proper operation during factory testing. J. Installation Guidelines 1. Specify that pumps be aligned, doweled, and grouted. 2. Provide pump suction fittings on the suction sides of base-mounted, centrifugal pumps. 3. Provide a pump discharge valve on the discharge sides of each base-mounted centrifugal pump. 4. Support pump fittings with floor-mounted pipe and flange supports. 5. Each pump must be level and re-aligned. Base-mounted pumps must be grouted. 6. Provide a spring-loaded check valve in the pump discharge, in lieu of a swing check valve. 7. If the pump motor is above 15 hp, provide a beam or rail system for removal from a crowded mechanical room. Subdivision 15400: Plumbing Fixtures and Equipment 21

Section 15441: Domestic Water Pumps K. Quality Control 1. If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. 2. Specify that at least one final alignment be performed in the field. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 22

15445 Sewage and Sump Pumps This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. Submittals C. Product Standards D. Manufacturers E. Special Requirements Source Control F. Installation Guidelines G. Quality Control This section includes design criteria for sewage ejector and sump pumping systems. B. Submittals Submit the following design, construction, and certification documentation. 1. Designer Submittals Submit pump sizing calculations for sewage ejectors and sump pumps. 2. Construction Documents Submit an installed pump performance test and balance report. 3. Product Certificates Signed by Manufacturer Specify that pumps be inspected by the manufacturer's authorized representative who must submit a written report to the engineer with a copy to Yale University stating that the pump has been properly installed, is operating correctly, and the installation is acceptable to the manufacturer in every respect. Subdivision 15400: Plumbing Fixtures and Equipment 23

Section 15445: Sewage and Sump Pumps C. Product Standards Products must conform to the following standards: Hydraulic Institute standards ASME PTC 8.2 and 9 CSA standards UL Motor-Operated Water Pumps Standard D. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. Sewage Ejector Pumping System SKB Weil Peabody Barnes KSB 2. Sump Pump Bell & Gossett (vertical flow series 800) Weil E. Special Requirements Source Control The manufacturer must maintain an inventory of all wearing parts within 50 miles of New Haven, CT. F. Installation Guidelines If the pump motor is above 15 hp, provide a beam or rail system for removal from a crowded mechanical room or air handler. When more than one pump is connected to a common discharge, each pump must have independent intake and discharge isolation valves and discharge check valves. All valves and check valves must be serviceable without entering the sump tank or sump pit. Each sump tank or pit shall have an independent high level alarm that goes to the energy management system. Subdivision 15400: Plumbing Fixtures and Equipment 24

Section 15445: Sewage and Sump Pumps G. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 25

15480 Domestic Water Heaters This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Submittals D. Product Standards E. Manufacturers F. Quality Control This section contains design criteria for tankless, instantaneous- and storage-type electric, gas, hot water heaters, both household and commercial. B. System Design and Performance Requirements 1. Design the plumbing system for safety, longevity, durability and flexibility. 2. The setpoint temperature for water heaters must be 120 F for general service and 140 F for kitchen dishwasher preheat. Provide mixing valves to distribute water to fixtures at 110 F. 3. Provide a minimum of two central water heaters for dormitories. 4. Provide temperature and pressure gauges at the inlet and outlet of each water heater. 5. Provide a minimum of two central domestic water heaters for each laboratory facility, each supplying 75% of demand. Coordinate with the Yale University Facilities group for other types of facilities for number of water heaters. 6. Use circulated hot water piping system, limiting dead ends to 20 feet. Subdivision 15400: Plumbing Fixtures and Equipment 26

Section 15480: Domestic Water Heaters 7. Install lockable-type shutoff valve, with lock, locked in the open position between the expansion tank and cold water supply. 8. Provide a properly sized pressure and temperature relief valve for each domestic water heater. 9. Recirculating pumps in domestic water heating systems must be of bronze construction. C. Submittals Submit the following design and certification documentation. 1. Designer Submittals Submit domestic hot water load calculations for: 180 dish washers Building domestic hot water heaters Kitchen booster hot water system Laundry hot water system 2. Product Certificates Signed by Manufacturer Specify that water heaters be inspected by the manufacturer's authorized representative who shall submit a written report to the engineer with copy to Yale University stating that the water heaters have been properly installed, are operating correctly, and the installation is acceptable to the manufacturer in every respect. D. Product Standards Products must conform to the following standards: ASHRAE 90.1b ASME Subdivision 15400: Plumbing Fixtures and Equipment 27

Section 15480: Domestic Water Heaters E. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. High-Recovery, High-Efficiency Gas Water Heaters AO Smith Maxi-Therm PVI 2. High-Recovery, High-Efficiency Electric Water Heaters AO Smith Maxi-Therm PVI F. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards, and listed in the project specifications, do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 28

15487 Heat Exchanger Water Heaters This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS B. System Design and Performance Requirements C. Submittals D. Product Standards E. Manufacturers F. Installation Guidelines G. Quality Control This section contains design criteria for steam, hot water, instantaneous, and storagetype water heaters. B. System Design and Performance Requirements 1. Design the plumbing system for safety, longevity, durability and flexibility. 2. Domestic hot water generators must be double wall. 3. Indirect water thermo-max. C. Submittals Submit the following design and certification documentation. 1. Designer Submittals Submit domestic hot water load calculations for: Building domestic hot water heaters Kitchen booster hot water system Laundry hot water system Subdivision 15400: Plumbing Fixtures and Equipment 29

Section 15487: Heat Exchanger Water Heaters 2. Product Certificates Signed by Manufacturer Specify that water heaters be inspected by the manufacturer's authorized representative who shall submit a written report to the engineer with copy to Yale University stating that the water heaters have been properly installed, are operating correctly, and the installation is acceptable to the manufacturer in every respect. D. Product Standards Products must conform to the following standards: ASHRAE 90.1b ASME E. Manufacturers Subject to compliance with the design requirements, manufacturers offering products that may be incorporated in the work include, but are not limited to, the following: 1. Instantaneous Steam Water Heaters (below 20 psi steam pressure) Leslie Armstrong 2. Semi-Instantaneous Steam Water heaters (greater than 20 psi and less than 60 psi steam pressure) Patterson-Kelley 3. Indirect Water Heaters Thermo-Max F. Installation Guidelines 1. Provide pull space for coils. 2. Provide a 2' minimum clearance around the units for maintenance. Subdivision 15400: Plumbing Fixtures and Equipment 30

Section 15487: Heat Exchanger Water Heaters G. Quality Control If this portion of the project includes commissioning, verify that insertions in the project specifications have been made that refer to the commissioning procedures in the commissioning specification section. Verify that the systems and equipment identified in this section of the standards and listed in the project specifications do not conflict with commissioning procedures for testing and training. End of Section Subdivision 15400: Plumbing Fixtures and Equipment 31