PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Similar documents
Added password for IP setup page : Password must be in IP format!

IndigoVision Alarm Panel. User Guide

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Innovative Circuit Technology Ltd.

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Innovative Circuit Technology Ltd.

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Alarm module for leak detection with webserver

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Ion Gateway Cellular Gateway and Wireless Sensors

MultiSite Manager. Setup Guide

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

THX-DL Data Logger USER & INSTALLATION MANUAL V

POWERBRICKALARM TCP/UDP IP Alarm Panel Installation and Operation Manual

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Getting started with

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Room Alert. Room Alert 32E, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

Installation and User Instructions

Table of Contents 1. INTRODUCTION 1 2. PANEL INFORMATION 2 3. GETTING STARTED 5 4. CONNECTION TO PANEL WEBPAGE 9 5. DEVICE MANAGEMENT 11

i-vu CCN 4.0 Owner s Guide

entri Series HE1U-XX12-BMS-MU Series

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

RLP-2048BBSCLVD-MU Internet Ready Heavy Duty AC to DC Power Supply With Built-in Remote Monitoring and Control. Owners Guide

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

Smart Combiners CG-VMU SolarVu. Installation Guide

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

WiFi GSM APP Smart Home Security System

BMS MU Internet Ready Battery Management System Owners Guide

Diagnostics and Monitoring System WEB Tool 2. User Manual

Ness acomms Install & User Manual

Home center Interface Server. Technical sheet

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

HikCentral Web Client. User Manual

babytel babybox INSTALLATION MANUAL Connection and Setup

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

PBI Manual. Paradox to KNX-BUS Interface

Proliphix. NT10e & NT20e. Configuration Guide

T4000 Security Communicator

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers)

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

VDC-HD3300/HD300P VDC-HD3100/HD3100P

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Installation, Configuration and User Manual

IP & SMS Alarm Communicator

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

Configuration and Operation Manual for the Unipos

Ademco Vista Alarm Panel

BMS MU Internet Ready 24 Volt Battery Management System With Built-in Remote Monitoring and Control. Owners Guide

AK-CS On Board Guide

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

Fire Operator Workstation (Fire OWS) User s Guide

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

FCD-wire Contents. List of Figures

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

CBI-064. User Manual. Caddx to KNX-BUS Interface

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

BAT WIFI SKU: IPD-BAT--WIFI

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

WebAlert WA500 Series Process Monitor Instruction Manual

Advisor Advanced Mobile Application User Manual

Lighting Xpert Insight User Manual

SIMATIC. Industrial PC SIMATIC IPC DiagBase V Introduction. SIMATIC IPC DiagBase software components. Quick-Start Guide

TX3 Series. TX3 Nano. Configuration Manual

User manual for CPR32-NET network controller

AZWG10200 ABUS PSTN/IP converter

Simplex Panel Interface Guide

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Siemens Drives & PLCs

Instruction Manual Environmental Monitoring Unit with Output Relay

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

rvm4c Installation Guide Remote Video Module

Home Automation. Product info. Marketed By: BlueSilica Technologies For further details write to

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Trident User s Manual

Installation Manual. ATS Remote Annunciator Catalog 5310 DANGER WARNING A

Table of Contents. i-vu CCN Standard 4.2

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements

PERMACONN PM1030 Includes DI300. Installation Manual

IRIS Touch Firmware Enhancements and Additions from Version to Version

Operation Manual For model CM706E

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

PRT-TS WiFi PRT-TS WiFi

Digijock Home Security

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

Transcription:

Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description :

The Solar Smart regulator was designed as an aid for Network owners to indicate voltage levels, charge currents and detect power related issues at remote sites with solar panels. Measurements : 1. Battery voltage 12v and 24v systems with Auto select 2. Charge current to Battery 20A max 3. Load current - max 6 Amps 4. Input wattage from Solar Panel 5. Output wattage and current to the load 6. Kw/h meter for Input and Output Power 7. Temperature sensing 8. Panel voltage monitoring and also indicating active or not. 9. 1 x Normally closed Tamper Alarm contact input 10. PC application software Solar Monitor

Monitoring web page: Indicating : Panel on/off status Panel voltage Battery voltage Charge current to Battery Input Watts Output Watts (+ amps) Total Kw/h meter for Energy in Total Kw/h meter for Energy out

PC Monitoring Software (Solar-Monitor) Setup instructions : Connect +12vdc or +24vdc (use correct terminal as per drawing) and ground supply power to the battery terminals Solar Smart R1 will be displayed Keep Factory reset button pressed (next to LAN RJ45) and switch on +12v or +24v power supply, Keep the Reset key pressed Starting network on Port 13 appears on the LCD, release the factory reset button as soon as run led is on permanently and LCD is stuck on starting network on Port 13 Default Factory settings will now be loaded and displayed on the LCD as: Device IP : 192.168.11.20 / IP address of unit Remote host : 192.168.11.1 / configure your pc LAN IP address to this

The MAC address of the LAN Port will be displayed on the Lcd. Message Starting Network on Port 13 will be displayed, where after about 2 seconds the Ethernet Port will be ready. The Heart beat Led should start blinking Web Browser (eg. Internet Explorer): Enter the default IP address of the unit into the search bar : 192.168.11.20 and connect After successfully connected to the LAN port the web configuration page will display. The unit will also display the status of all measurements on the web configuration page. After Network settings is changed under the IP settings button click the Update button. The Clear Counters button will clear both the Kw/h counters The reload page will refresh the web page, the unit refresh automatically every 3 sec The unit will indicate Re - Boot while rebooting to load the new configured settings User settings Loaded will be displayed from now every time the unit boots up and the user s programmed IP address and Remote Host addresses will be displayed, unless a factory reset is done again..

Monitoring Screen Panel : On B: 13.3V I: 07.6 A L: 1.32A Top Left: Panel : On if Panel is active Panel off if Panel is not active Top Right: Battery Voltage Bottom Left: I : Amps that is currently flowing to battery Bottom Right: L: load current in Amps consumed by the load Every 18 seconds a packet is transmitted over Ethernet in UDP protocol The following screen will be displayed : UDP Data Send Ok ****The unit will detect a Faulty or no LAN connection condition here and the following will be displayed or if the host IP is not found on the network *** NO LAN CONNECTED! Or No Host found The unit will restart to try and re-establish a LAN connection again

ALARM input This is a normally closed alarm input the board already supplies power on the alarm input so the user should only connect a potential free switch type contact. The Alarm input will only be activated after the first data packet was successfully sent over Ethernet. Should the contact be opened the unit will transmit the Alarm data immediately An alarm condition will be generated in the pc solar monitor software. Tamper Alarm! Alarm Data send Installing the Software Run the.zip file - Solar monitor setup this will install Solar monitor V1.0.0.0 on the system follow instructions on screen. Select Add tower to add a tower line double click the tower line to alter any settings for the specific tower. Select Remove Tower to delete a tower entry. Setup Emails to receive e-mails for any alarms generated by the unit (eg. Low battery volts below user setting temperature above user setting Tamper alarm) with date and time stamp should the alarms have been enabled for this in the setup menu of a tower line. Under e-mail settings also select if fault restored e-mails should be send with date and time stamp the moment the fault have been cleared. Selecting Station button the user set a station name for the software display on top left of screen. Select list or block view alters the display window user defined

In the tower setup menu after a double click on the tower line, Tower name : Enter a user defined name for the tower Tower Ip Address : Enter the Ip address for the unit as programmed onto the hardware Solar unit Battery Alarm level (Below): Enter the Battery voltage where an alarm condition should be generated for a low battery voltage condition in decimal.eg : 11.3 or 10.5 etc. Temperature Alarm level (Above): enter the value in degrees Celcius for alarm condition to be generated in case of temperature above user setting. Eg : 40 or 35 Tamper Alarm Enabled: Select the checkbox should the tamper alarm be activated, The Software will respond to tamper alarm data received from NPM. If un checked the software will still receive tamper alarm data from the NPM unit but will not respond to it. Log Data if enabled keeps a 48hr graph of battery voltage and charging current Log Faults : if enabled keeps record of alarm conditions that occurred for each tower line E mails can also be setup to send a mail to a specified address as in the users e-mail settings list as soon as a alarm condition exists, the user can also select to receive another e-mail as soon as the alarm condition have been cleared General settings tab : Select automatic IP address detection of the unit if no blockage of the IP address occurs on the network

Select use data as specified in packet if gateway or router is blocking the Solar Smart IP address Server and remote function : Selecting remote function for a remote computer will auto populate the list of units installed on the server computer onto the remote view computer.