Chemical resistant Vacuum Pumps

Similar documents
OPERATING MANUAL English Chemical Resistant Diaphragm Pump

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

Laboport Chemically-resistant Laboratory Pumps and Systems

RK/ RK Oxygen Detector Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

RK-02 Multi Point Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

RK CO 2 Transmitter Operator s Manual

Owner s. 18 Misting MF18W. To view

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

RK-05 Carbon Monoxide Detector Operator s Manual

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Model # VWK-2 INSTRUCTION MANUAL

RK-05 Combustible Gas Transmitter Operator s Manual

Industrial Vacuums, Inc

SOUS-VIDE CIRCULATOR.

RK Multi Point Detector Operator s Manual

FSW300 Series Flow Switch

Eldex Column Heater. Operator s Manual

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

AUTOMATIC GRANULAR ICE FLAKER

569, 570, 571, 572 Series

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

569, 570, 571, 572 Series

RK Hydrogen Sulfide Transmitter Operator s Manual

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Safety, Operation and Maintenance Manual with Parts List

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

High Output Vacuum/Pressure Pump

RK/ RK Oxygen Detector Operator s Manual

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Combustible Gas Sample-Draw Detector Operator s Manual

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

MN908 No. 282C Replaces 282B LB7013

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Agilent Vac Elut SPS 24 Manifold User Guide

Instruction Manual. Fun Pop 4oz Popper

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

568X, 587X, 588X Series

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

SCC-E Sample Gas Feed Unit. Operator s Manual 42/23-58 EN Rev. 1

SuperKlean Washdown Products

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

Instruction Manual. Cheese Warmer with Pump

K Specifications. Max. Water Volume

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

RK-03 Hydrogen Detector Operator s Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Instruction Manual GP110 GelPump

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

USER MANUAL SAVE THESE INSTRUCTIONS


INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

100 Series Maxi Internal Filters

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

USER MANUAL UN-200V / UN-200VH

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Instruction Manual. Nacho Cheese Dispenser and Warmer

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Bag-In-A-Box Oil Pump System

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Wax Base Heater & Dispenser

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage

Carbon Dioxide Sample-Draw Detector Operator s Manual

457LAVBP10QT LAVEX HEPA BACKPACK VACUUM CLEANER

CONSTANT SUCTION UNIT

AUTOMATIC ICE-CUBE MAKER

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

USER S MANUAL ATH WH220

RK / RK Methane Detector Operator s Manual

ASPIRE Laboratory Aspirator

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

K Specifications. Max. Water Volume

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

RK Carbon Monoxide Transmitter Operator s Manual

Owner s Guide. Powerhead Canister Vacuum Cleaner

Instruction Manual. Bucket Oil Pump

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Indirect Cryogenic Cold Trap System Instructions

RK Carbon Monoxide Transmitter Operator s Manual

Operation Manual R205BV, R209BV

EHA Hoffmann International GmbH

Mechanical seals external, single or double, to DIN EN 12756

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Transcription:

Chemical resistant Vacuum Pumps C300 / C400 / C410 / C510 / C600 / C610 English Operating Manual WIGGENS labortechnik GmbH Mühsamstrasse 3610249 Berlin Germany Fon:+49 30 42105470 Fax:+49 30 42105971 E-Mail: info@chemvak.com Web: www.chemvak.com

Chemical Resistant Vacuum Pumps C300/C400/C410/C600/C510/C610

Congratulations! You have made an excellent choice. Wiggens wants to thank you for the trust you have placed in us. This operating manual has been designed to help you gain an understanding of the operation and possible applications of our C series vacuum pumps. For optimal utilization of all functions, we recommend that you thoroughly study this manual prior to beginning any operation. The Wiggens Quality Management System ISO 9001 Certificate Registration No. 01 100084841 Unpacking and Inspection Unpack the pump and accessories and inspect them for possible transport damage. Damage should be reported to the responsible carrier, railway, or postal authority, and a damage report should be requested. These instructions must be followed fully for us to guarantee our full support of your claim for protecting against loss from concealed damage. The form required for filing such a claim will be provided by the carrier. Printed in Germany Changes without prior notification reserved Important: Keep the operating manual for future use 2 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

Contents 1. Important Notice... 4 2. Unpacking... 4 3. Installation... 4 4. Warning... 5 5. Function and Operation... 5 5.1. C300... 5 5.2. C400... 6 5.3. C410/C510/C610... 7 6. Parts List... 8 6.1. C300... 8 6.2. C400... 9 6.3. C410/C510/C610... 10 7. Vacuum Regulator / Moisture Trap (Optional)... 11 7.1. Installation of the Vacuum Regulator/ Moisture Trap (C300)... 11 7.2. Installation of the Vacuum Regulator/ Moisture Trap (C400/C600)... 12 7.3. Installation of the Vacuum Regulator/ Moisture Trap (C410/510/C610)... 13 7.4. Functions of the Vacuum Regulator/ Moisture Trap... 13 8. Troubleshooting... 14 9. Changing the Pump Diaphragms and the Valve Plates/Sealings... 15 9.1 Pump Head... 16 9.2 Two-headed pumps... 17 10. Specifications... 20 11. Ordering Information... 22 12. Warranty... 24 13. Product Liability... 24 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 3

1. Important Notice The vacuum pump is designed for laboratory use only. Before the setup and operation of the unit, please read these instructions carefully to get familiar with the entire installation and operation process. Any individual should be well trained either by reading the instructions or by undergoing specific instructions from the authorized distributors technical staff before operating the unit. Do not modify or alter the unit in any way. Any modification or alteration will void the warranty and can result in potential hazards. We cannot be made responsible for any injury or damage caused by using the unit in a way that is not intended by the manufacturer or for modification of the unit by any person who is not authorized. 2. Unpacking Please make sure that the unit is in good condition. In case of damage or the lack of any part when unpacking the unit, please contact our local distributor or contact us by e-mail under info@chemvak.com for immediate assistance. 3. Installation 1) Check the voltage specified on the nameplate at the bottom of the unit. Make sure that it matches the current requirements in your location. 2) Install the unit in a clean, dustless, and ventilated area where the ambient temperature is under 40 C. 3) To enable the suction function, connect the inlet of the pump to the outlet of your objective equipment with a high-pressure hose. 4 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

4. Warning 1) When finished pumping, please do not turn off the pump at once and continue to run the vacuum pump for at least two minutes in order to draw out the mist and tiny liquids to prolong the service life of the pump. 2) The filter cartridge (optional) is used to absorb moisture and dust. Please replace it when it is saturated to maintain a high pumping efficiency. 3) If the pump does not work when turning on the switch, please release the vacuum and turn it on again. If the pump still fails to start, there may be a problem in the switch or motor. In that case please contact your local distributor for help immediately. 4) Never use the pump with any flammable gas or toxic material. 5) In case of any damage at the pump, please directly contact your local distributor or the Chemvak service department for help. Do not repair it by yourself to avoid hazard. 5. Function and Operation 5.1. C300 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 5

Operating Procedure 1) Schematic of the pump system is shown as above. 2) When all tubes are connected, the pumping function is activated by pressing the On/Off button. 3) For vacuum monitoring and regulation, an optional vacuum regulator / moisture trap is needed. * Warning: When the pump is used for water filtration never let the liquid level of the flask exceed the safety level. Failure to comply could result in serious damage to the pump and void the warranty. 5.2. C400 6 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

Operating Procedure 1) The diagram of the pump system is shown as above. 2) When all tubes have been properly connected to the Inlet (1) and Outlet (2), activate the pumping function by pressing On/Off button (3). 3) For vacuum monitoring and regulation, an optional vacuum regulator / moisture trap is needed. Warning: When the pump is used for water filtration never let the liquid level of the flask exceed the safety level. Failure to comply could result in serious damage to the pump and void the warranty. 5.3. C410/C510/C610 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 7

Operating procedure 1) The diagram of the pump system is shown as above. 2) When all tubes have been properly connected to the Inlet (1) and Outlet (2), activate the pumping function by pressing On/Off button (3). 3) For vacuum monitoring and regulation, an optional vacuum regulator / moisture trap is needed. Warning: When the pump is used for water filtration never let the liquid level of the flask exceed the safety level. Failure to comply could result in serious damage to the pump and void the warranty. 6. Parts List 6.1. C300 8 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

Index Description Qty Index Description Qty 1 On/Off Switch Cup 1 13 Stainless Plate 2 2 On/Off Switch 1 14 Setscrew 8 3 Front Body Lid 1 15 Tier Connector 2 4 Set Screw 8 16 Condenser 1 5 Counterweight 2 17 Rubber Stand 4 6 Bearing 2 18 Clog 1 7 Connecting Rod 2 19 Body 1 8 Diaphragm 2 20 Cooling Fan 1 9 Diaphragm block 2 21 Rear Body Lid 1 10 Plug-in Unit 4 22 Plug 1 11 Valve Plate 4 12 Diaphragm Head 2 6.2. C400 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 9

Index Description Quan Index Description Quan 1 On/Off Switch Cup 1 14 Condenser 1 2 On/Off Switch 1 15 Rubber Stand 4 3 Front Body Lid 1 16 Clog 1 4 Set Screw 8 17 Body 1 5 Counterweight 2 18 Cooling Fan 1 6 Bearing 2 19 Rear Body Lid 1 7 Connecting Rod 2 20 Plug 1 8 Diaphragm 2 21 PistonsetCover 1 9 Diaphragm Block 2 22 L-Connector 2 10 DiaphragmValve 4 23 Interflow Tube 2 11 Diaphragm Head 2 24 T-Connector 2 12 Stainless Plate 2 13 Tier Connector 2 6.3. C410/C510/C610 10 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

Index Description Quan Index Description Quan 1 On/Off Switch Cup 1 14 Condenser 1 2 On/Off Switch 1 15 Rubber Stand 4 3 Front Body Lid 1 16 Clog 1 4 Set Screw 8 17 Body 1 5 Counterweight 2 18 Cooling Fan 1 6 Bearing 2 19 Rear Body Lid 1 7 Connecting Rod 2 20 Plug 1 8 Diaphragm 2 21 Piston set Cover 1 9 Diaphragm Block 2 22 L-Connector 2 10 Diaphragm Valve 4 23 Interflow Tube 1 11 Diaphragm Head 2 12 Stainless Plate 2 13 Tier Connector 2 7. Vacuum Regulator / Moisture Trap (Optional) 7.1. Installation of the Vacuum Regulator/ Moisture Trap (C300) 1. Remove the screw at the side of the cylinder head with a spanner. 2. Remove the tier connector with a spanner. 3. Fix the screw removed from step 1 at the location where you removed the tier connector in step 2. Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 11

4. Fix the moisture trap at the location where you removed the screw in Step 1. 5. You completed the operation successfully. 7.2. Installation of the Vacuum Regulator/ Moisture Trap (C400/C600) 1. Remove the Teflon tier connector at the side of the cylinder head with a spanner. 2. Fix the moisture trap at the location where you removed the Teflon tier connector in Step 1. 3. You completed the operation successfully. 12 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

7.3. Installation of the Vacuum Regulator/ Moisture Trap (C410/510/C610) 1. Remove the Teflon tier connector at the side of the cylinder head with a spanner. 2. Fix the moisture trap at the location where you removed the Teflon tier connector in Step 1. 3. You completed the operation successfully. 7.4. Functions of the Vacuum Regulator/ Moisture Trap Vacuum regulator/ Moisture Trap is used to filtering possible particles and liquid from coming in the pump, with the vacuum gauge and adjusting valve, a approximate vacuum level can be maintained, however for more accurate vacuum control a precision vacuum controller is needed. Replacement of the Cartridge: When the filter cartridge is saturated and the flow rate or vacuum decreases, the filter cartridge should be replaced. Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 13

First, remove the moisture trap by rotating the cup counterclockwise. Second, remove the cartridge in the same way and replace it with a new one. Dispose the water in the moisture trap as described above. 8. Troubleshooting 8.1. Sufficient vacuum is not reached Possible reasons: 1 Tube connections are not tight. 2 Condensate in the pump head(detach the condensate source from the pump). 3 Diaphragms and/or valve plates/sealings are worn out(changing diaphragms and valve plates/sealings). 4 If this problem occurs after changing of diaphragms and valve plates/sealings. 8.2. Pump is switched on, but does not run, the on/off-switch on the pump is not lit Possible reasons: 1 Pump is not connected with the power source. 2 No voltage in the power source. 8.3. Pump is switched on, but does not run, the on/off-switch on the pump is lit Possible reasons: The thermal switch has opened due to overheating (disconnect the pump from the power source, let the pump cool down, investigate the reason for the overheating and irradicate it). 14 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-15052013

9. Changing the Pump Diaphragms and the Valve Plates/Sealings Structured diaphragm and valve plates/sealings are the only parts subject to wear. It is easy to change them. In the case of two-headed pumps the structured diaphragms in both pump heads should be changed at the same time. When the structured diaphragms are changed, valve plates/sealings should also be replaced. If the structured diaphragms are not changed in both heads at the same time or the structured diaphragms and valve plates/sealings are not changed at the same time the nominal performance of the pump is not guaranteed after the service. If a pump has been used for aggressive or toxic substances or other types of substances which are hazardous, hazardous to health, or injurious, the following points must be observed: 1) Clean the pump and its components before servicing. 2) Ensure that the service personnel is not subject to a health hazard. Apply the safety and protection measures that are necessary for the medium that has been handled by the pump (example: the use of protective gloves). 3) Ensure that discarded parts and materials are safely and correctly disposed of. Use only original CHEMVAK replacement parts. Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 15

9.1 Pump Head The position numbers in the following text refer to fig. 4. (1)Screw (2)Screw (3)Disk spring (4)Top plate (5)Head plate (6)Valve plate/sealing (7)intermediate plate (8)Guide pin (9)Structured diaphragm (10) Spacer (thick) (11) Spacer(thin) (12)Dampening ring A (13)Screw (14)Dampening felt (15)Dampening ring B (16)Adapter (17)Dampening ring C (18) Dampening diaphragm 16 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

9.2 Two-headed pumps Required tools and material: Change the structured diaphragms and valve plates/sealings in the following sequence: a) Preparatory steps b) Remove pump heads c) Change structured diaphragms d) Change valve plates/sealings e) Refit pump heads f) Final steps Detail description for the procedures: a) Preparatory Steps 1 Shut down system including disconnecting the pump from the power source (pull out plug of electrical supply unit or of socket). 2 Remove tubing from the inlet and outlet connectors of the pump. 3 If the pump is integrated in a vacuum system: Remove pump from the Baseplate. b) Removing the pump heads 1 On the pneumatic head connections, loosen one of the union nuts by hand. Then slightly loosen the angle-fitting in the pump head by turning it anticlockwise, so that the connecting tube can be pulled out. 2 Loosen the outer screws(1)on each pump head. 3 Carefully remove both pump heads(top plate(4), head plate(5) and intermediate plat(6). c) Change structured diaphragms 1 Push down one structured diaphragm(9)until other structured diaphragm is pushed upwards to its highest position. 2 Carefully unscrew the higher structured diaphragm anti-clock- wise using both hands. 3 Replace all spacers (10)/(11)onto the screw thread of the new structured Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 17

diaphragm (same number and order) 4 Screw in the new structured diaphragm(9)and tighten it by hand; you do not need any tool. 5 Change the second structured diaphragm as described above (step(1)to(4))for the first. Changing the two structured diaphragms one after the other ensures that the same number of diaphragm spacers are refitted as were removed. This is essential to maintain the pneumatic performance of the pump. d) Change valve plates/sealings 1 For one pump head: Unscrew the single screw(2) 4 (C510: three screws) in the top plate(4). 2 Carefully remove top plate (5) and head plate(5)from inter mediate plate(7); exposing the valve plates/sealings(6) 3 Remove old valve plate/sealings(6). 4 If there should be deposits in the recesses in the intermediate plate(7)clean them until the deposits have been completely removed. 5 Insert new valve plates/sealings(6)in the recesses in the intermediate plat(7)(upper and lower sides of the valve plates/sealings are identical) 6 Carry out the steps(1)to(5)for the second pump head. e) Refitting the pump heads For one pump head 1 Press the lip on the edge of the structured diaphragm(9)into the groove in the housing. 2 Place the intermediate plate(7), with the valve plates/sealings on the adapter(16), in the position indicated by the guide pin ( 8 ). 3 Place the head plate( 5 )on the intermediate plate ( 7 )in the position indicated by he guide pin ( 8 ). 4 Place the top plate ( 4 )on the head plate in the right position. 18 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

5 Gently tighten screws ( 1 )in diagonal order. 6 Screw in the single screw (2) (C510: three screws) in the centre of the pump top plate (4)until it is flush with the top plate(they are flush with the top plate), 7 Then screw one final half turn to tighten. For orientation of disk springs(3)see fig.4. Carry out steps (1)to (6)for the second pump head. Refit the pneumatic head connection: Place tube onto the connecting part of the angle fitting, turn angle fitting to a straight position and tighten the union nut. f) Final steps 1 Remount the pump to the baseplate. 2 Reconnect system tubing. 3 Reconnect the pump to the electricity supply. If the pump does not reach the desired vacuum after changing diaphragms and valve plates:/sealings: 1 Check whether the spacers have been replaced onto the structured diaphragm screw thread. 2 Check the interconnecting pipe- work connection between both pump heads as well as the tubing for leaks. 3 Possibly the screws on one of the pump heads (or both heads) are insufficiently tightened (carefully tighten them again crosswise). If you have any questions about servicing call our technical adviser(see last page for contact telephone number). Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 19

10. Specifications C300 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 22 L/min 100mbar abs 1 bar (14.7 psi) 5.0 kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 95W C400 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 34 L/min 120mbar abs 1 bar (14.7 psi) 7.0kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 95W C410 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 25 L/min 13mbar abs 1 bar (14.7 psi) 7.0 kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 95W 20 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

C510 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 34l/min 8mbar abs 1 bar (14.7 psi) 12.6 kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 245W C600 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 60 L/min 90mbar abs 1 bar (14.7 psi) 12.6 kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 270W C610 Maximum capacity Ultimate vacuum Maximum continuous pressure Weight of pump Permissible ambient temperature Permissible temperature of gas to be pumped Mains(Voltage/Frequency) Power Consumption Power 34 L/min 2mbar abs 1 bar(14.7 psi) 13.4 kg +5...+40 C +5...+40 C 230V/50Hz; 110V/60Hz 245W Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 21

11. Ordering Information C300 169300-22 169300-11 C300 Vacuum Pump, AC230V/50Hz C300 Vacuum Pump, AC110V/60Hz 167300-06 Vacuum Regulator/ Moisture Trap 169300-07 Filter Cartridge 167300-08 Magnetic Suction Flask Set (167300-13 with Bottom Plate) 167100-18 Gelman 4242 Funnel 167100-41 Stainless Steel Funnel (100ml) 167100-20 Gelman A/E#61631 Fiberglass Filter, ψ47mm C400 169400-22 169400-11 C400 Vacuum Pump, AC230V/50Hz C400 Vacuum Pump, AC110V/60Hz 169300-06 Vacuum Regulator/ Moisture Trap 167300-07 Filter Cartridge 169400-60 C400/410 Repair Kit C410 169410-22 169410-11 C410 Vacuum Pump, AC230V/50Hz C410 Vacuum Pump, AC110V/60Hz 169300-06 Vacuum Regulator/ Moisture Trap 167300-07 Filter Cartridge 169400-60 C400/410 Repair Kit C510 169510-22 169510-11 C510 Vacuum Pump, AC230V/50Hz C510 Vacuum Pump, AC110V/60Hz 169300-06 Vacuum Regulator/ Moisture Trap 167300-07 Filter Cartridge 169600-60 C510/600 Repair Kit 22 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013

C600 169600-22 169600-11 C600 Vacuum Pump, AC230V/50Hz C600 Vacuum Pump, AC110V/60Hz 169300-06 Vacuum Regulator/ Moisture Trap 167300-07 Filter Cartridge 169600-60 C510/600 Repair Kit C610 169610-22 169610-11 C610 Vacuum Pump, AC230V/50Hz C610 Vacuum Pump, AC110V/60Hz 169300-06 Vacuum Regulator/ Moisture Trap 167300-07 Filter Cartridge 169610-60 C610 Repair Kit Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013 23

12. Warranty We guarantee the perfect functioning of this instrument against defects in material, design, and workmanship, when use under appropriate conditions and in accordance with the instruction manual for a period of TWO YEARS from the date of initial shipment. This warranty covers all parts and components of the instrument except those normally requiring frequent replacement, such as tubing, gasket, O-rings, etc. We will not be liable for any personal injury, improper maintenance, or negligence of accident. 13. Product Liability Under no circumstances shall Chemvak be liable for indirect, consequential or otherwise special or unrelated damages of any kind. Chemvak reserves the right to make technical changes wihout prior notice. Email: info@chemvak.com Web Site: www.chemvak.com 24 Chemvak Operating Manual for C serial chemical resistant pumps V1.2-11052013