DS7400Xi Addressable Control/ Communicator

Similar documents
Reference Guide for the DS7400Xi (Version 3+) Control/Communicator

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

Solution-8248 Installation Manual ISSUE 1.16

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

P Zone Expandable Hybrid Security System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Addressable Fire Alarm Control Panel

D7024 Fire Alarm Control Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Model 17A00 Expansion Enclosure

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

DS7465i. Installation Instructions. Input/Output Module

DOOR MONITORING/DURESS SYSTEM

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

TECHNICAL DATA OBSOLETE

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

Installation Manual Premier 412/816/832. Issue 10

good things in small packages

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Multiplex Eight Input Remote Modules

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Control/Communicator

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Installation Guide. Control/Communicator

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Fire Alarm Control/Communicator

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

WIRELESS CONTROLS & DETECTORS

System Introduction. 1.1 Specifications S E C T I O N 1

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

INSTALLATION MANUAL PC15OO

EVO192 v3.0 Fire and Burglary What s New

TABLE OF CONTENTS TABLE OF CONTENTS 1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

INSTALLATION MANUAL PC56O. Version 1.OA

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Conventional Releasing Control Panel

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

OJD ITB No Attachment E Duress Alarm Equipment Specifications

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

D1255RB/D1256RB/D1257RB

30.45 Electric Release PDRP-2001

Control/Communicator Installation Manual

Flair 500 Series Annunciators

System Overview. PC4020 v3.3

INTELLIGENT FIRE ALARM CONTROL PANEL

Integrated Security Solutions

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

System Introduction. 1.1 Specifications

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

FMR Installation Instructions. Addressable Fire System Controller

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

System Manual W A R N I N G. PC6O1O Software Version 2.1

Reference Guide for the D7024 Control/Communicator

Integrated Security Solutions

ACP10 & ACP50 Security Systems

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

PC4020 v3.2 Installation Manual DLS-3 v1.3

D2412 Control / Communicator Installation Manual

LifeAlarm Fire Alarm Control Panels

Fire Control/Communicator

Remote NAC Power Supply D7038

INSTALLATION MANUAL DV8OOO. Software Version 1.0

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Copyright Detection Systems PTY Ltd. Unit 21, 45 Gilby Road Mount Waverley, Victoria 3149, Australia Fax:

NETWORK FIRE ALARM CONTROL PANEL. Features

D7212 Control/Communicator Operation and Installation Manual

INSTALLATION GUIDE XTLN-WIFI PANEL

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

INSTALLATION MANUAL. PC3OOO Version 7.6W

D720 and D1255 Command Centers

DS7400Xi (version 3+) Security System User s Guide

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Transcription:

DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems to be remotely programmed using an IBM PC (or IBM compatible) running Windows and a standard Hayes modem. Using an off-site computer permits diagnostics to be run, systems to be armed, and zones bypassed. This not only reduces service visits to a premise, it also allows quick customer assistance in closing troublesome accounts. Freely Programmable Alpha Display UL Listed,, CSFM Approved 90 PINs The system supports 90 Personal ID Numbers, which are 4 digits in length. Any number of PINS may be designated as master PINs; these are the only PINs which can be used to reprogram PINs. PINs other than the master PINs may be programmed with 7 different levels of authority. These PINs may be restricted from bypassing, testing and disarming the system. Certifications The DS7400Xi is an Addressable Control/ Communicator. It accepts up to 90 Personal ID Numbers (PINs), is keypad or remotely programmable, and has a wide range of features. Features Eight Partitions The DS7400Xi Series may be split up into 8 completely separate systems. Each partition has its own keypads and can have its own reporting ID. Keypads can also be programmed as master keypads, allowing access to all partitions. History Buffer A 400 event history buffer, which can be read at the DS7447 keypad or uploaded to the WDSRP Remote Programming Software, keeps track of Open/Close events, Alarms, Troubles, etc. by time and date. 64 events are in non-volatile memory. Keypad Programmable The system is completely keypad programmable. No need for expensive handheld programmers. UL Standards UL985, Control Units and Accessories - Household System Type UL864. Control Units, System UL1023, Household Burglar Alarm System Units UL365 and UL464, Police Station Alarm Units Connection Grades AA* and A UL294, Central Station Alarm Units UL1076, Proprietary Alarm Units UL464 and UL609, Local Alarm Units ULC Listed CSFM * Grade AA, UL Listing is in compliance when used with Motient/ARDIS sm Transceiver or other selected communications systems. Refer to current UL installation approvals in the DS7400Xi Reference Guide. S306-M89 Commercial Fire Approved Meets commercial fire requirements when used with the DS7420i (Dual Phone Line/Bell Supervision Module), DS7447 Alpha Numeric Keypad with red graphic, and AETR-16 (enclosure for transformer). The DS7400Xi has 8 on-board zones may be used as Class B (Latching) input loops and will accept up to 20 two-wire smoke detectors (such as DS250 Series) each. Addressable zones support 4-wire and Multiplex MX280 smoke detectors. Suitable for installation in NFPA 72 applications as applies to Local, Central Station, Remote Station, Sprinkle Supervisory, and Waterflow. 99

Patents 5,268,668 5,302,941 Basic Functions LED and Alpha Keypad Support Zones Automatic Arming/ Delayed Arming Common Area Partitioning Smoke Detector Alarm Verification DS7445 LED keypad Provides an LED per zone (for main board zones 1-8 only), plus eight system status LEDs that indicate conditions such as armed, fire alarm, and trouble. DS7447 Alpha Numeric keypad Two line display allows 16 characters of custom text to be programmed for zone and partition descriptions. The user can adjust the sounder volume and backlight intensity using easy twobutton commands. The DS7447 is required for system programming. LED and LCD keypads may be mixed in the same system. The DS7400Xi accepts up to 128 zones. These zones may consist of eight hardwired zones, plus the remaining addressable zones. Any of these zones may be programmed to follow one of 15 programmable zone functions. An automatic arming time can be programmed for each partition each day. The user may use Delayed Arming to override automatic arm time or to specify a time for the panel to arm. One partition can be programmed to follow the arming state of some or all of the other partitions. The common area arms only when all partitions that are linked to it are armed. This allows for protection of shared areas such as foyers and entry-ways, while still maintaining separate partitioning. The DS7400Xi Series may be programmed to perform an automatic reset of the smoke detectors, should an alarm occur. If a second alarm occurs within the verification window, an immediate fire alarm results. This reduces potential false alarms, while still providing fast response to an alarm. Custom Arming Configurations Answering Machine Override Three Telephone Numbers EE Memory Output Functions Input/Output Cross Matrixing Octal Relay Modules Addressable Bus Outputs Control Panels The system can be programmed to arm in different configurations providing a means of automatically bypassing a group of zones. The DS7400Xi has a built-in answering machine override function. No external hardware is required. The system supports two 20-digit telephone numbers with a three or four digit account code. Each of the two phone numbers can be configured for the type of communication format and choice of pulse or tone dialing. The third phone number used for remote programming. The panel uses EEPROM technology; thereby, allowing it to retain all program memory as well as the arm/disarm state through a total power failure. There is also a delay on power restore to prevent false alarms from space sensors that may take several minutes to become operational. None of the system programming or user codes will be lost. Output Functions can be programmed to follow system events or to follow one or two specific zones in a cross matrix fashion (see Input/Output Cross Matrixing). These Output Functions can be programmed to control octal relay outputs or addressable bus outputs. Input/Output cross matrixing allows Output Functions to follow the status of specific input zones. Outputs can be programmed to follow any combination of one or two zones, open or closed, with the system armed or disarmed. The DS7400Xi supports up to two DS7488 Octal Relay Modules or two DS7489 Solid State Output Modules. Each module supplies 8 relay or solid state outputs to follow system events or to follow programmed Output Functions from the DS7400Xi. The DS7400Xi supports up to 20 DS7465 Input/Output modules. These modules are connected to the addressable bus and provide one input loop and one Form C output relay. The input loop operates the same as all other addressable inputs. The output loop can be programmed to follow Output Functions. www.dsworld.com (888) 289-0096 Detection Systems, Inc. 100

Anti-Takeover Protection Two Independent Entry Delays Easy Function Key User Interface Flexible Digital Communication All or part of the programming may be locked so the program cannot be changed should someone attempt to takeover the account. Patented BusLoc anti-takeover circuitry imbeds a secret code into the addressable devices, prohibiting the control from being replaced using these devices. Zones may be programmed to select from one of the two entry delay times. This allows the selection of a longer entry delay time for zones that are located a long distance from the keypad. Six labeled function keys eliminate the need for multi-button commands. Enter a PIN followed by the function key to perform functions such as arming, disarming, and resetting smoke detectors. The interface provides new users with easy to follow procedures. The interface does not use cumbersome menu driven formats, so expert users can quickly access the items they need. A programmable Quick Arm feature allows users to turn the system on without a PIN. However, a PIN is required to turn off the system, silence alarms, or perform system tests. Residential Mode requires a PIN to disarm the system, silence alarms, and reset the system. The communicator will work into most alarm receivers that are in use today, and support 3/1, 4/1, 4/2, Contact ID, SIA, BFSK digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code. Technical Specifications Operating Temperature Communicator +32 F to +120 F (0 C to +49 C) Will report to two phone numbers with full single, double and backup reporting. Communicates in 3/1, Ext., 3/1 with Parity, 3/1 Ext. with Parity, 4/1, 4/2, BFSK, Contact ID, and SIA digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code. FCC registration Number is ESVUSA-75333- AL-E The ringer equivalence is 0.1 B. Enclosures AE1/AE2 The DS7400Xi has two standard enclosures: (AE1 - is a gray enclosure, and AE2 is a red enclosure). Both are manufactured from 20 Ga., cold-rolled steel, and measure (WxHxD) 12.5 in. x 14.5 in. x 3 in. (320 cm x 370 cm x 76 cm). A keyed lock is included, and these enclosures have provision for an optional tamper switch for monitoring the door. AE3/AE4 The AE3 is a large gray enclosure and the AE4 is a large red enclosure. Both are manufactured from 18 Ga., cold-rolled steel, and measure (WxHxD) 15 in. x 20.75 in. x 4.25 in. (380 cm x 530 cm x 108 cm). A keyed lock is included, and these enclosures have provision for an optional tamper switch for monitoring the door. Lightning Protection Burglar/Fire Zone Inputs MOVs and spark gaps provide protection from lightning surges and static discharges. Number of circuits: eight circuits on board End of line resistor: 2.21k ohms 101 Detection Systems, Inc. (888) 289-0096 www.dsworld.com

Fire Signal Initiating Circuits (2 wire mode) Fire circuits will work with 2 or 4-wire detectors and have optional alarm verification. Number of circuits: eight circuits on board, expandable to 16 Type of circuit: Class B, latching End of line resistor: 2.21k ohms Supervisory current: 5 ma Minimum current for alarm: 12 ma Maximum short circuit current: 22 ma Maximum circuit resistance: 60 ohms Circuit voltage range: 8.5 to 14.1 VDC Max. impedance for alarm: 1000 ohms Maximum detectors per zone: 20 detectors (2-wire) Total detector standby current: 2.5 ma Outputs The system provides three outputs that are individually programmable and may be controlled by alarms, access control, ground start, smoke detector reset, or the control s arming state. The DS7400Xi has three outputs expandable to 39, and DS7400Xi16-EXP is expandable to 15. Alarm Output Normally Open, 1.75 Amp contact connected to auxiliary power. Programmable Output 1 Solid state current sink (1 Amp Max.). Can be used for alarm, arming state, or access control. Programmable Output 2 Solid state voltage source (500 ma Max.). Can be used for alarm, arming state, or access control. Keypads Number of keypads: 15 keypads Max. wire length each: 1000 ft. (300 m) Max. wire length total in system: 5000 ft. (1800 m) Wire type: 4 conductor 18-22 AWG. Note: No more than 2 keypads per 1000 ft. (300 m) run. Optional Accessories DS7104 Line Reversal Module Provides a reverse polarity output for direct connection applications. Provides both a maintained and alternating output. Power Requirements Input: 18 VAC, 50 VA, 50 or 60 Hz Total power output: 12 VDC, 2.5 Amps Keypad regulated power: 12 VDC, 1.0 Amps UL Listed Auxiliary power: 12 VDC, 1.0 Amps UL Listed Alarm Power Output: 1.75 Amps Optional Standby Battery (P334): 12 V, 7.0 AH (can support up to 35 AH) Programmable Outputs 110 VAC and 220 VAC transformers available DS7111i Dual Phone Monitor Provides two phone line supervision and switching with trouble output. Connects to one zone of control. Not for use in Commercial Fire applications. DS7412 RS232 Interface Module Provides the ability to print history events either real time or via a keypad command. Connects to a standard serial printer. Also allows direct connect programming using the WDSRP software. DS7420i Dual Phone line/bell Supervision Module Provides a supervised 12 volt bell output, dual phone line supervision, one Class A (Style D) Commercial Fire Zone and a latched Form C relay output. 1 per system. DS7430 Multiplex Bus Driver Provides an expansion bus for connection of multiplex devices. One per system. www.dsworld.com (888) 289-0096 Detection Systems, Inc. 102

DS7432 8-Input Remote Module Provides eight supervised input zones for connection of additional Normally Open or multiplex bus. Requires use of DS7430 or DS7433 8-Input Direct Module Provides eight supervised input zones for connection of additional Normally Open or Normally Closed inputs. These eight zones support 2-wire smoke detectors when configured as fire zones. Connects directly to DS7400Xi in place of multiplex bus. Cannot be used with DS7430 or 1 per system. DS7445 LED Keypad Eight Zone LEDs. Eight system status LEDs. Sounder volume is controlled via simple two button commands. DS7447 Alpha Numeric Keypad Displays two lines of 16 characters of custom text to be programmed. The Alpha information is remotely downloadable and it can be programmed by the installer at the keypad. Sounder volume and backlight intensity is controlled via simple two button commands. DS7450 Flush Mount Multiplex Contact Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Requires DS7430 or DS7452 Surface Mount Multiplex Contact Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Requires DS7430 or DS7455 Surface Mount Single Multiplex Contact Point Provides replacement for conventional dry contacts. Reports actual multiplex address to the control panel. Occupies 1 zone. Requires DS7430 or DS7457 (DS7457i, DS7457iF) Single Zone Multiplex Input Module Provides one supervised input zone for connection of conventional Normally Open or multiplex bus. Requires DS7430 or DS7460 (DS7460i) Two Input Module Provides two supervised input zones for connection of conventional Normally Open or addressable bus. Requires DS7430 or DS7461i Single Input Module Provides one supervised input zones for connection of conventional Normally Open or addressable bus. Requires DS7430 or DS7465 (DS7465i) Input/Output Module Provides one supervised input for connection of conventional Normally Open or Normally Closed inputs. Also provides one Form C relay which can be programmed to follow system events of the status of specific zones. Connects to addressable bus. Up to twenty (20) per system for the DS7400Xi. Requires DS7430 or MX280 Series Smoke Detectors Multiplex Photoelectric Smoke detectors with Chamber Check Self Diagnostics. MX280TH includes 135 heat sensor. MX280THL includes 135 heat sensor plus low temperature sensor. MX775i Addressable PIR A 50 ft. Microprocessor-based wall mount, addressable PIR detector. Uses Motion Analyzer II Processing. Includes Motion Monitor and three sensitivity settings. Internally pointable field replaceable mirrored optics provide three coverage patterns. Requires use of DS7430 or DS7436, occupies one zone. MX794i Long Range Multiplex PIR Intrusion Detector A 200 ft. Microprocessor-based wall mount, DIP switch programmable PIR intrusion detector. Uses Motion Analyzer II Processing and has three sensitivity settings. Field replaceable mirrored optics provide three coverage patterns. Requires use of DS7430 or 103 Detection Systems, Inc. (888) 289-0096 www.dsworld.com

MX835 Addressable TriTech PIR/Microwave Detector with Animal Immunity A 35 ft. PIR/Microwave detector which includes PIR/Microwave supervision features. Requires DS7430, occupies one zone. DS7488 Octal Relay Module Provides eight Form C relay outputs. These outputs are fully programmable and can be activated by several different system events. Two per system (DS7400Xi). AETR-16 Enclosure Mounts over standard electrical outlet. Provides mechanical protection for transformer and wiring connections. MX934i Addressable PIR A 35 ft. Microprocessor-based wall mount, dipswitch programmable PIR detector. Uses Motion Analyzer II Processing and has two sensitivity settings. Internally pointable field replaceable mirrored optics provide four coverage patterns. Requires use of DS7430 or DS7436, occupies one zone. MX938i Addressable PIR A 60 ft. diameter Microprocessor-based ceiling mount, addressable PIR detector. Uses Motion Analyzer II Processing. Includes three sensitivity settings field replaceable mirrored optics. Requires use of DS7430 or DS7436, occupies one zone. MX950 Addressable PIR A 50 ft. Microprocessor-based dual technology wall mount, 4-wire addressable PlR/microwave detector. Supervision features include anti-masking protection and Motion Monitor. Four coverage patterns using field replaceable fresnel lenses. Requires use of DS7430 or DS7436, occupies one zone. DS7480 Bell Supervision Module Provides power and supervision for one endof-line supervised indicating appliance circuit. Connects to programmable alarm output of DS7400Xi series. Indicates trouble condition using a Form C relay connected to one zone. DS7481 Single Phone Line Monitor Monitors one phone line. Provides a normally open relay output which closes upon phone line failure. P/N 29329H Detection Systems, Inc. 130 Perinton Parkway, Fairport, New York 14450-9199 (585) 223-4060 Cust. Service (888) 289-0096 Fax: (585) 223-9180 Faxback: (800) 315-0470 104