INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Similar documents
Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Vent Supplement Ultra-80, -105, -155, -230 & -310

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL

ASX7-5-IOM-3 J

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Pellet Stove. Flex Pipe. Appliance Connector

ASX7-4-IOM-6 J

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Direct Exhaust Venting Kit Instructions

INSTALLATION INSTRUCTIONS

Do not use this vent pipe or fittings for venting incinerators of any kind.

BDM Direct Vent systems are for use with direct vent gas fired appliances.

COMMON VENTING SYSTEM SUBMITTAL SHEET

INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Ventis Direct Vent. Installation Instructions

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

SEPARATED COMBUSTION WARNING

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.ca

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Vent and air piped through a side wall (concentric termination)

OPTION CA1, CA2, AND CA3 POWER VENTERS

Installation instructions for the T 9820 Gas Dryer

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

Saf-T Vent SC Plus/SC 316

Installation, Operation and Service Manual

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

FOR YOUR SAFETY WARNING FOR YOUR SAFETY. high efficiency, separated combustion gas-fired unit heaters models PTC and BTC

Vent Kit for Condensing Tankless Gas Water Heater

INSTALLATION GUIDE Dual Fuel Ranges

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

INSTALLATION AND OPERATING INSTRUCTION MANUAL

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

Installation Instructions

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

BlueHeat AirTop 2000 Heater

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

PelletVent Multi-fuel venting system. UL 641.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Technical and Dimensional Data. Saf-T Vent SC Plus

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Installation Electric Dryers Instructions 01

Ultra Boiler Series 1 & 2 Jacket Parts

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Aqua Balance. Direct Exhaust Venting Kit Instructions

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

SEPARATED COMBUSTION. General

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type D)

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

SEPARATED COMBUSTION. General WARNING

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

HIGH-EFFICIENCY DOWNFLOW / HORIZONTAL FURNACE INSTALLER'S INFORMATION MANUAL

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

SWIMMING POOL & SPA HEATER D-2

Heat Exchanger Block Replacement Instructions

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Tankless Water Heater Direct Vent Sweet Termination Installation Instructions

Installation Instructions and Use & Care Guide

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Installation and Maintenance Instructions

Manual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

SCS SCS

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

Mighty Venter Power Vent System

VERTICAL POWER VENT KIT

Installation & Maintenance Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

User s Information Manual

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

Noble Fire Tube Boiler and Combi Installation & Service Manual NKC NKB

ZC Kit AGP Pellet Insert

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

GB162 Concentric Horizontal Vent Kit

2012 INTERNATIONAL FUEL GAS CODE VENTS

Transcription:

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and local codes regarding installation and location of vent systems for direct vent appliances. In the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Code. The maximum vent length, as stated in the EVERHOT IGI model series Water Heater Installation and Operating Instruction Manual and these instructions, should never be exceeded. Follow the instructions below and all instructions located in the EVERHOT IGI model series Water Heater Installation and Operating Instruction Manual when installing a vent pipe system. Improper installation of vent piping, or failure to follow all installation instructions completely, can result in property damage, and/or death. WARNING Refer to the Bradford White EVERHOT IGI series Water Heater Installation and Operating Instruction Manual for details concerning vent system termination positions/clearances, allowable vent pipe lengths, and in what position dip switch #1 should be placed. If you do not understand how to configure your vent pipe system and/or which position dip switch #1 should be placed in, please contact your Bradford White supplier for assistance. WARNING All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system installation to prevent any possible leakage into the room. Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal. Prior to the Installation of EVERHOT direct vent systems: The EVERHOT IGI water heaters have two adjustable wall mounting support brackets fitted on the top and bottom of the appliance. When installing a Standard Vent Discharge Kit" to vent directly through the wall to the back of the water heater, these brackets should be adjusted so that the water heater is spaced its maximum distance of 2" (5.1 cm) away from the wall. Before cutting the vent terminal to the appropriate length, ensure you have taken into account just how far the heater has been spaced away from the wall. NOTICE When mounting the water heater on an outside wall, be sure the Vent/Air Intake Pipe will exit between the wall studs. DO NOT cut through the wall studs for the Vent/Air Intake Pipe opening. 238-44957-00B Rev. 1/08 1

WARNING All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system installation to prevent any possible leakage into the room. Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal. WARNING Before installation inspect each vent component for damage and correct seal placement. Do not attempt to fix or install any damaged vent components. Condensate When the total vent system length is greater than 5 ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5 ft. (1,52 m), a condensate collector and trap must be installed. Recommended vent/air intake terminal position Terminals should be so positioned as to avoid products of combustion entering openings into buildings or other flues or vents. Figure 12 2

* For clearances not specified in ANSI Z223.1 / NFP A 54 or CGA-B149, please use clearances in accordance with local installation codes and the requirements of the gas supplier. ** For other than Direct Vent Appliance, 4 feet (1.22 m) below or to side of opening; 1 foot (300 mm) above opening. 3

General Installation Instructions Joint connection Figure 13 Vent connections others must be firmly pressed together so that the gaskets form an airtight seal. Coping with condensation Figure 14 Make sure that the sockets are pointed 1 upwards in order to keep the gaskets dry. (Except for the (short distance) standard horizontal discharge vent system without extensions. See Figure 34.) Appliance connection Figure 15 The first vent component to the appliance must be a vertical discharge adapter or a horizontal discharge adapter. Never use an extension as the first component, this might cause damage to the water heater and vent system. Secure vent connections with pipe clamps or perforated hanger. 4

Condensate drain Every vent system should have a condensate collector unless installed with a total vent length of less than 5 ft. (1,52 m). To prevent condensate from draining back to the appliance, a condensate collector (B) and trap (C) should be installed. Attach condensate collector to the discharge adapter (A). The trap must be inspected annually for obstructions and water content in the trap. Provisions must be made to properly drain and dispose of condensate; be aware that condensate is a highly corrosive substance that could damage metals. The hose (D) should be subject to inspection; kinks must be avoided. Dispose of condensate in accordance with local codes. Minimum water level in the condensate trap must be 3 (75 mm). Figure 16 Shortening of vent extensions Figure 17 The aluminum inside pipe should always extend 0.4" (10 mm) beyond the white plastic outside pipe on the male end of the vent extension. Always cut the male end of the vent pipe extension. Do not attempt to cut the female end. Figure 18 Pipes overlap by 2.5 (65 mm). Therefore when cutting to size, add 2.5 (65 mm) to the extension pipe length (X) needed for installation. Deburr the sharp edges, other wise the gaskets may get damaged, which can result in the system no longer being air tight. 5

WARNING Improper installations of vent system and components, or failure to follow all installation instructions, can result in property damage or serious injury. Parts & Dimensions Components needed for direct vent applications: Figure 19 Figure 20 1) horizontal discharge adapter 2) vertical discharge adapter BWC p/n 239-44506-00 BWC p/n 239-44500-00 Figure 21 Figure 22 3) wall discharge terminal plate 4) rubber wall Length = 12 (305mm) BWC p/n 239-46848-00 Part of BWC vent kit 6

Figure 23 Figure 24 Figure 25 5) vent extension 6) 45º vent pipe elbow 7) 90 º vent pipe elbow 10 BWC p/n 239-44496-00 (sold in pairs only) BWC p/n 239-44499-00 19.5 BWC p/n 239-44497-00 BWC p/n 239-44495-00 39 BWC p/n 239-44498-00 Figure 26 Figure 27 8) condensate collector 9) vent pipe clamp BWC p/n 239-44501-00 BWC p/n 239-44493-00 Figure 28 Figure 29 10) vertical discharge roof terminal 11) pitch roof flashing BWC p/n 239-44494-00 (1/12) BWC p/n 239-44502-00 (8/12) BWC p/n 239-44503-00 (6/12) BWC p/n 239-44504-00 7

Figure 30 Figure 31 12) flat roof flashing 13) condensate trap kit BWC p/n 239-44492-00 8

Installation Instructions Everhot Horizontal Discharge Vent System Identify the vent location Figure 32 Steps: - Place horizontal discharge adapter on water heater - Mark position on wall - Or use template provided with water heater - Cut hole, covering the top of the water heater to prevent debris from entering Measure dimension to fit Figure 33 Figure 34 NOTICE Note: if the vent system is shorter than 5 ft. (1,52 m) and no condensate collector is installed, be sure to install the wall terminal with a 1 angle to the outside of the building. 9

NOTICE Note: 3.5 (90 mm) is the minimum outer cap length. If needed the length outside the wall may exceed this dimension. Final installation of the venting system Figure 35 From the outside of the building, slide the wall discharge terminal through the vent wall passage. A supplied rubber wall plate can be installed on the exterior of the building. Slide the inner wall plate onto the terminal. If necessary apply silicon sealant to fill up spaces between vent terminal and the wall. Vent connections must be firmly pressed together so that the gaskets form an airtight seal. NOTE When the total vent system length is greater than 5ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5ft. (1,52 m), a condensate collector and trap must be installed. 10

Horizontal Vent System Installation examples Figure 36 11

Installation Instructions Everhot Vertical Discharge Vent System Identify the vent location Figure 37 Determine the location where the roof discharge terminal will be installed. Taking into account the angle of the roof, cut the hole with a dimension that allows the vertical discharge roof terminal to be installed. Cut to fit The terminal can be shortened by removing the components A+B+C, and then shortening both the inside and outside pipes with the same length X. Re-assemble the terminal by attaching the components A, B, and C in the correct order. Tighten component B securely. Figure 38 12

Mounting the vent system Figure 39 Vent connections must be firmly pressed together so that the gaskets form an airtightseal. Secure the system with the supplied vent pipe clamp or perforated hanger iron. NOTE When the total vent system length is greater than 5ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5ft. (1,52 m), a condensate collector and trap must be installed. 13

Vertical Vent System Installation examples Figure 40 14

Cut Line Template 15