Minimum Core Module Version: 4.0, build 1608 See full list of supported models below. Document Revision Date: 1/9/2018

Similar documents
Integration Note OVERVIEW AND SUPPORTED FEATURES THE LYRIC THERMOSTAT SUPPORTS THE FOLLOWING FEATURES:

Model Number(s): WiFi Thermostats: 8840, 8830, 8820, 8810 Models Tested: 8820 rev 1.04

TR/TS40, TR/TS16, TR/TS60 Thermostat

RCS Residential Control Systems Inc.

Integration Note OVERVIEW AND SUPPORTED FEATURES. Minimum Core Module Version: g! Document Revision Date: 2/14/2013

- Data Brochure Universal Reset Module 423

4 Wiring Brochure Wiring and

- Data Brochure Universal Reset Module 422

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Data Brochure tekmarnet 4 Thermostat 542e

Metasys Integrator TITUS Application

Hydronic & HVAC Control Systems

Wiser Air User Interface Guide. Thermostat

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

Better Design, Better Control, Better Systems.

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

RCS Residential Control Systems Inc.

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

EL-TSTAT-8820 Safety & Installation Instructions

Safety & Installation Instructions

Modbus RTU RS485 Manual

- Data Brochure Snow Detector & Melting Control 665

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installer Manual KNX Touchscreen Thermostat

Model TZ43. ZWave Thermostat INSTALLATION AND OPERATION MANUAL DCN: /22/08 *** IMPORTANT NOTICE ***

Installation & Operation Manual

Installation, Configuration and User Manual

ModBus DE-1 INSTALLATION AND USER MANUAL

Installation, Service, and Troubleshooting Instructions

Daikin ENVi Thermostat installation overview

Laptop / PC Programming Manual

CHV-TSTAT-FCU Heating and Cooling Fan-Coil Thermostat. Supplemental Guide Crestron Electronics, Inc.

Ethernet General Purpose

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Installation & Operation Manual

MODEL DZSP/ SZSP-1440 AIRCELL

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

Database for CTS6000 MODBUS

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Entero Voice Alarm system.

Get Stoked. Stoker Users Manual Ver 2.0 Software. Get Stoked 1 Rock s Bar-B-Que

- Data Brochure Boiler Control 274

HEAT PUMP PROGRAMMABLE THERMOSTAT

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

SC Installation, Operation & Application Guide

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

- Data Brochure Mixing Reset Module 421

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

mti085 Temperature Interface

CommStat 4 Controller

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

Cellular Monitoring System

Installation & Operation Manual

SC Installation, Operation & Application Guide

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

Dryer Controller M720

Proliphix. NT10e & NT20e. Configuration Guide

Condensing Boiler RS100 Controller Training Program

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

HeatNet Manual Control Adjustment and Operation Instructions for Hydrotherm Firmware Version 2.8

Product Manual SZ1145

Cellular Monitoring System

GLOBAL. InstallatIon & operation manual

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

ComfortSense 7500 Commercial Thermostat. User Guide

Melt Demand. Idle Demand. WWSD Water. Melting. Stop. Do not apply power. Do not apply power. 5 Brn/ Slab. Com tn2. Input. Melt/Idle.

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Section 9 System Operation

HAI Omni-Bus Network Installation. 5. Typical Application

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

PBI Manual. Paradox to KNX-BUS Interface

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

ComfortSense 7500 Thermostat. User Guide

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Product Manual SZ1022/SZ1031/SZ1035/

Brivis Touch Controller. Installer Manual

CBI-064. User Manual. Caddx to KNX-BUS Interface

T8602C Chronotherm IV Deluxe Programmable Thermostats

Product Manual SZ1144

Section 8 System Operation

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

VT8300 Series Installation Guide 24 Vac Low Voltage

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Omnistat Architectual Specifications

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

2017 MacroAir Technologies Toll Free: Fax:

T8600D Chronotherm IV Deluxe Programmable Thermostats

ATS Annunciator - MODBUS

Transcription:

Integration Note Manufacturer: Tekmar Model Number(s): Tekmar Net 4 Minimum Core Module Version: 4.0, build 1608 Comments: See full list of supported models below. Document Revision Date: 1/9/2018 OVERVIEW AND SUPPORTED FEATURES Tekmar Net 4 (tn4) products utilize a compatible zone manager and optional expansion modules in conjunction with tn4 Thermostats. Tekmar tn4 Thermostats are not traditional thermostats, as all HVAC connections are typically made at the Zone Manager. Four wires are needed from the zone manager to the thermostat for communication across the tn4 bus. The tn4 network requires a RS232 Gateway Module be installed alongside the standard Tekmar equipment for control and feedback in ELAN. The Tekmar Net 4 series of climate control products support multiple HVAC setups, including radiant heat. See Tekmar for full details. IMPORTANT NOTE: The Tekmar tn4 Climate System requires the use of a RS232 Gateway to talk to climate equipment and thermostats, and ELAN is not able to directly communicate with the Thermostats. The tn4 Gateway is designed to internally query the thermostats on the tn4 at a rate of roughly one TStat per minute, but also processes changes made at the thermostat according to different internal priorities. This can result in delays of several minutes before data is reported to ELAN, and due to internal priority levels, certain changes can be reflected ahead of others. This may cause what would appear to be contradicting information to display in the Viewer, such as a Thermostat showing Heat Mode with Cooling Active, due to a change in Mode at the Thermostat. These contradictions may take minutes to fully resolve as the full data queries are completed by the Tekmar Gateway and finally reported back to ELAN. Note that this latency will primarily occur when changes are made at the physical thermostat. Changes made from ELAN interfaces should reflect almost immediately. It is still possible TStat calls (heat active etc.) may have some delay before being reflected in ELAN, but latency and odd display behavior are greatly reduced if changes are only made in ELAN. THE TEKMAR THERMOSTATS SUPPORT THE FOLLOWING FEATURES: Temperature Control: Temperature control can be managed by schedules in ELAN tied to house modes or by manual control based on time (Timed Temporary Hold, Temporary Hold and Permanent Hold). Temperature can be shown as either Fahrenheit or Celsius on the viewer interface. Schedule Control: Multiple schedules can be set using the Viewer software. The schedules are tied to the house mode. Mode Control: The supported tekmar thermostats can be set to run in the following ELAN heating and cooling modes: Heat only, Cool only, Auto Heat Cool, Vent or Off. Note that modes available will be dependent on the features of the thermostats used. Snow Melt Control: As of ELAN v8.2, ELAN can track and control Melt or Storm mode on the 654 Snow Melt Control. ELAN SpeakerCraft Gefen Furman Niles Panamax Sunfire BlueBOLT Proficient Xantech 1800 South McDowell Blvd., Petaluma CA 94954 Toll Free: 800.472.5555 Fax: 707.283.5901

History View: The history view shows the inside temperature, outside temperature, unit run times, and cooling and heating set points. Note that Tekmar does not report actual equipment run values, but instead reports when the TStat desires heat or cool. Auto Thermostat Detection: The ELAN system will automatically detect all supported thermostats connected to system, along with each thermostat s ID (number). Outside Temperature Sensor: The outside temperature sensor connected to the Tekmar Zone Manager may be read into ELAN. Remote Sensors that replace the internal sensor: Tekmar Thermostats may be capable of having a remote temperature sensor configured to replace the on-board room temperature sensor. In this configuration remote sensors are supported. THE TEKMAR THERMOSTATS DO NOT SUPPORT THE FOLLOWING FEATURES: Any feature not specifically noted as supported is not supported. Scene/Schedules at Thermostat: When integrated with ELAN, the internal scenes programmed into the thermostat cannot be used with ELAN and are disabled. In addition, schedules at the Thermostat cannot be used in ELAN and should always be set to None, as these may have adverse impact on external control and communication. Remote Sensors: Additional sensors in a Tekmar system are not supported in ELAN, with the exception of the network outside temperature sensor. All other sensors are not discretely available to external communication and control; the Tekmar thermostats will only report their room temperature. Fan Control and Status: Fans are hard-coded as part of the HVAC setup in a Tekmar system with set run times depending on the system state and current HVAC call. Status and Control of fans is not available in ELAN. Vent Mode: Scheduling and Tracking of Vent mode is not currently supported. Decimal Temperature Control: ELAN Core module 5.5 added support for decimal/fractional temperature display. Tekmar Thermostats are not compatible with control using fractional numbers. TEKMAR MODELS SUPPORTED: tn2 Thermostats: 527, 528, 530 tn4 Thermostats: 537, 538, 540, 541, 542, 543, 544, 545, 546 tn4 Snow Melt Control: 654 tn4 Gateway: 482 Other tn4 products: See Tekmar for details. ELAN communicates with the tn482, and does not directly communicate with Zone Managers, Reset Modules, Expansion Modules and so forth. Note: Some tn2/tn4 products must be running a minimum version of firmware to communicate with the tn482 Gateway. Contact Tekmar for full details. In some cases, you may need to set the thermostats to heat mode and then restart the Tekmar equipment for reliable 2-way communication. 2 of 6

INSTALLATION OVERVIEW 1. Install the Tekmar thermostat network and control cables during the rough-in phase. Consult the HVAC unit manual for control cabling requirements. 2. Run a Cat5 wire from the RS232 Gateway back to the Network Assembly of the ELAN system. 3. Install and power up the thermostats one at a time. Program the thermostats as outlined in the thermostat programming section. 4. Test the thermostat and climate system to ensure that the thermostats correctly turn on the appropriate heating or cooling equipment, and open or close the appropriate valves / dampers. 5. Set all thermostats to HEAT mode, and then restart the Tekmar thermostats and 482 gateway. 6. Connect the ELAN system to the Tekmar 482 RS232 Gateway electrically. See the wiring diagrams for more information. 7. Configure the ELAN system for the thermostats and confirm communication between the thermostats and the ELAN system controller. Use the auto detect (Discover Devices) feature to find the thermostats on the network. 8. Test the system by changing the set points, modes and schedules on the viewer and various thermostats, confirming that the various components in the system are communicating with each other. Note that it may take several minutes for all information to populate in the system after initial setup. THERMOSTAT/SNOW MELT PROGRAMMING In general, Tekmar climate control equipment should be programmed according to standard Tekmar procedures, but ELAN does require the following steps during programming of the Tekmar system: Manually program each thermostat with a unique network address. Do NOT allow the thermostats to get their address automatically, or their address may change. You must manually assign a static address to ensure reliable communication with ELAN. Ensure that schedules/master schedules are set to None (disabled) at each thermostat. Setback scenes should be disabled at each thermostat. See the Tekmar documentation for your particular thermostat for details. Snow Melt 654: o o In tekmar By default, the tekmar 654 uses melt group ID 1 for Snow Melt mode and ID 12 for Storm Mode. Refer to the tekmar installation and operation manual for this device to determine and or change its melt IDs. In ELAN - The tekmar snow melt control will be discovered in ELAN as Relay Outputs on the Configurator Input/Output page. 12 Relays (Melt Group IDs) will be discovered. To control in ELAN add an output toggle control button on a customizable page for control and status of the desired melt group ID. Be sure to connect the toggle button to the desired Melt Group ID. Note since these are relays in ELAN they may also be used in event maps, or with other custom buttons as desired. 3 of 6

CONNECTION DIAGRAMS Thermostat 1 Wall Display Unit 1 2 Cat5 or 18-4 Cable tn4 Zone Manager 3 Control Wirng to HVAC unit/dampers Consult HVAC and Tekmar documentation for wiring details Wall Display Unit 2 g! Controller 7 Wall Display Unit 3 HA-CB-307 RJ45F to DB9M 5 RS-232 Port Wall Display Unit 4 tn4 Bus Power Consult Tekmar documentation for wiring details RS232 6 HA-CB-328 RJ45F to DB9F NULL MODEM 2 Cat5 4 tn4 Gateway 482 BILL OF MATERIALS # Device M anufacturer P art Number P rotocol Connector Type Notes 1 Thermostat Tekmar Various tn4 Screw Terminals tn4 Series 2 Cat5 Cable Installer N/A tn4 None 18-4 may be substituted for TStat wiring 3 tn4 Zone Manager/HVAC Modules Tekmar Various tn4 Screw Terminals 4 tn4 Gateway Tekmar 482 tn4 X RS232 Screw Terminals X RJ45 5 Null Modem Adapter ELAN HA-CB-328 RS-232 DB-9 Female X RJ-45 Female Tekmar requires NULL MODEM 6 Male DB9 to RJ45 ELAN HA-CB-307 RS-232 DB-9 Male X RJ-45 Female 7 g! Controller ELAN Various (ex. HC-12) RS-232 RJ-45 Female Use COM 1, 2, 3, etc. 4 of 6

ELAN CONFIGURATION DETAILS The following table provides settings used in the ELAN Configurator. Please refer to the Configurator Reference Guide for more details. In the table below: o <Select> Select the appropriate item from the list (or drop-down) in the Configurator. o <User Defined>, etc. Type in the desired name for the item. o <Auto Detect>, etc. The system will auto detect this variable. Devices Variable Name Setting Comments Communication Devices Name <User Defined> (Default: New Device) Elan recommends renaming for clarity Type Serial Port Communication Type Tekmar RS232 Network Location <User Defined> (Not Required) Com Port <Select> COM1, 2, 3 etc. HVAC Units Name <User Defined> Model Generic HVAC Unit Controls Heat Set to Yes if controlling Heat Controls Cooling Set to Yes if controlling Cooling Controls Fan Set to No. Fans are not supported. <Discover Devices> Click the Discover Devices button on the Communication Device Thermostats Name <User Defined> Discover Devices will set a default name of "Tekmar #1101", etc. Location <User Defined> (Not Required) Com Device <Auto Detect> Thermostat # <Auto Detect> Heating Unit Cooling Unit Schedules HVAC Schedule Programs Monday - Sunday <Select days> Periods per Day Global Options Units Fahrenheit or Celsius Temporary Hold Mode Timed Hold or Hold until next period Temporary Hold Default Time <Select> Outside Temperature Sensor Choose optional sensor if installed or choose Internet. Outside Humidity Sensor Choose optional sensor if installed or choose Internet. Note: Following Discover Devices, thermostats should immediately populate in Configurator. It is normal for the TStats to take several minutes following discovery to stop showing "Connecting to Thermostat" in the Viewer. Likewise, during programming in ELAN, it is normal for all communication lines to be turned off and restarted (such as when adding a Communication Device). When this occurs, the Tekmar system will show Connecting while all communication lines are re-initiated and data is re-read out of the Tekmar system. 5 of 6

COMMON MISTAKES 1. Incorrect Tekmar programming. If the Tekmar is programmed incorrectly, it can cause internal Tekmar communication trouble which will also affect ELAN s control and feedback. If there are flashing circled exclamation points on any of the Tekmar LCD s, this is indicative of a wiring or setting problem. See Tekmar documentation for assistance. 2. Failing to use a null modem connection in the communication line to the Tekmar. Tekmar connections must be null modem. 3. Allowing the Tekmar thermostats to automatically receive their network address. You must manually assign the address to all tekmar thermostats prior to integration and discovery. Failing to do so may result in wrong addresses, unused addresses, and thermostats that do not respond in ELAN. 4. Incorrect Snow Melt group address. The Snow Melt Control 654 factory default uses Melt Group 1 and Storm Group 12. Verify the ELAN controls are connected to the tekmar Snow Melt control Melt group address and Storm group address as configured in the 654. Refer to the 654 installation and operation manual for finding and setting these addresses. 6 of 6