SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

Similar documents
SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

PolySwitch TS600 Overcurrent Protection Devices

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Gas Discharge Tubes GTCX28-XXXM-R05 Series

Telecom Fuses. Benefits. Features. Applications

Gas Discharge Tubes. Features: Benefits: Applications:


DATASHEET PolySwitch RKEF Devices

Specification Status: Released

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

Specification Status: Released

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

RUE Selection Guide and Product Data. RUE Selection Guide

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

PolySwitch Telecommunications and Networking Resettable Devices

Specification Status: Released

Specification Status: Released

Multi Layer Varistor Overvoltage Protection Device

PolySwitch Telecommunications and Networking Resettable Devices

and Product Data VTP Selection Guide

PolySwitch Surface-mount Resettable Devices

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

M7100 Pressure Transducer

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

CII FCAC-150 Series Relay

D5100 Industrial Differential Pressure Transducer

Technical Data Sheet 1.6mm Side Looking Phototransistor

Technical Data Sheet 3mm Phototransistor T-1

D5100 Industrial Differential Pressure Transducer

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Technical Data Sheet 5mm Phototransistor T-1

AO Annunciator Module

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

Technical Data Sheet 1.5mm Side Face Infrared LED

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

FEATURES ORDERING CODE EMCP C 100 N T (1) (2) (3) (4) (5) (6) (7) SMT Multilayer EMI Filter (Power Line) TRIGON COMPONENTS

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

ULTRA FAST RECITIFIERS

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

INTERNATIONAL STANDARD

M5200 Industrial Pressure Transducer

PCB Relays Single Relays

Technical Data Sheet 5mm Infrared LED, T-1

M5800 Pressure Transducer with Rotatable Display

SMD 2121 Black Frame MC-S2121BHA

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

VAMP 120 & 121. Arc flash detection units. Product picture

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Inverted Through Board Surface

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

PolySwitch Surface-Mount Resettable Fuses

Installation Instructions for the

DP86 Constant Voltage with Fitting

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Installation Instructions CS3 Three Phase Solid State Relay

Jun08 Rev C

U5300 Industrial Pressure Transducer

Chapter 7. Troubleshooting

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Introducing Hermaphroditic Blade and Receptacle Connector

U5700 Submersible Liquid Level Pressure Transducer

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

M5800 Pressure Transducer with Rotatable Display

Austin Series Non-Isolated SMT DC - DC Power Modules: 3.3 Vdc and 5.0 Vdc Input, 1.5 Vdc Vdc Output, 6A

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Fiber Optic Distribution Cables (6-144 Fibers)

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

USB 3.0 Plug & Receptacle

PRODUCT SPECIFICATION

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Technical Data Sheet Opto Interrupter ITR

Applications. Application Summary 41

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

KILOVAC K1K High-Voltage Contactor

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

HM1500LF Relative Humidity Module

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

PlanarMag Product Technology

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Preliminary specification

Transcription:

Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction. These devices have a high electrical surge capability to help protect against transient faults and a high off-state impedance, rendering them virtually transparent during normal system operation. SiBar thyristor surge protectors are designed to assist telecommunication and computer telephony equipment in meeting the applicable requirements and industry specifications. Benefits: Features: RoHS compliant Helps provide protection for sensitive telecom electronic equipment Low leakage current Low power dissipation Fast, reliable operation No wear-out mechanisms Helps designers meet worldwide telecom standards Helps reduce warranty and service costs Easy installation Helps improve power efficiency of equipment Bidirectional crowbar transient voltage protection Broad voltage range 58V 320V with improved Vdrm/Vbo voltage range High off-state impedance Low on-state voltage High surge capability Short-circuit failure mode Surface-mount technology DO-214AA SMB package 10 x 1000 μs 50A surge rating Helps equipment comply with TIA-968, Telcordia GR-1089, IEC61000-4-5, ITU K.20/21/45 Applications: Modems Fax machines Set top boxes POS systems Phones, answering machines Analog and digital linecards (xdsl, T1/E1...) PBX systems Other customer premise and central office network equipment requiring protection 2007 Tyco Electronics Corporation. All rights Reserved. 1 Rev: B Date: DECEMBER 12, 2007

Table SB1 - Electrical Characteristics Part Number V DM Max. (V) V BO Max. (V) I H Min. (ma) V T Max. (V) C1 (Typ) 50V DC Bias C2 (Typ) 2V DC Bias Off-State Current VD2=VDM (μa) TVB058NSA-L 58 77 150 4 44 84 5 TVB065NSA-L 65 88 150 4 41 79 5 TVB075NSA-L 75 98 150 4 34 65 5 TVB090NSA-L 90 130 150 4 31 58 5 TVB120NSA-L 120 160 150 4 24 46 5 TVB140NSA-L 140 180 150 4 23 44 5 TVB170NSA-L 170 220 150 4 20 39 5 TVB180NSA-L 180 240 150 4 19 37 5 TVB190NSA-L 190 260 150 4 19 36 5 TVB220NSA-L 220 300 150 4 17 33 5 TVB275NSA-L 275 350 150 4 15 31 5 TVB320NSA-L 320 400 150 4 14 27 5 Notes: All electrical characteristics are measured at 25 C. VDM measured per UL497B pulse requirements: at max. off-state leakage current (IDM) = 5 µa. VBO measured at 100V/µs. C1 measured at 1 MHz with a 50 VDC bias. C2 measured at 1MHz with a 2V DC bias. Table SB2 Surge Current Rating Part Number TIA-968 Telcordia GR-1089* IEC61000-4-5 ITU K.20/21/45* Type A 5 x 320 µs Type B pp (A) 10 x 560 µs 10 x 160 µs 10 x 1000 µs 2 x 10 µs 8 x 20 µs I PP (A) 5 x 310 μs (VOC: 10 x 700μs) I TSM Min. (A) di/dt dv/dt (A/µs) (V/µs) TVBxxxNSA-L 90 70 100 50 150 150 90 22 500 2000 Notes: *Lightning current wave forms for applicable industry specification. ITSM, peak on-state surge current is measured at 60 Hz, one cycle. di/dt: critical rate-of-rise of on-state current (pulsed power amplifier Vmax = 600V; C = 30µF). dv/dt: critical rate-of-rise of off-stage voltage (linear wave form, VD = rated VBO, Tj = 25 C 2007 Tyco Electronics Corporation. All rights Reserved. 2 Rev: B Date: DECEMBER 12, 2007

Table SB3 s in Millimeters A B C D Min. Max. Min. Max. Min. Max. Min. Max. 4.06 4.57 3.30 3.94 1.90 2.41 1.95 2.20 TVBxxxNSA-L (0.160) (0.180) (0.130) (0.155) (0.075) (0.095) (0.077) (0.087) H J K P S Min. Max. Min. Max. Min. Max. Ref Min Max. TVBxxxNSA-L 0.051 0.200 0.150 0.31 0.76 1.27 0.51 5.21 5.59 (0.002) (0.008) (0.006) (0.012) (0.030) (0.050) (0.202) (0.205) (0.220) Notes: *D dimension is measured within dimension P. TVB series devices use industry standard SMB package type. All devices are bidirectional and may be oriented in either direction for installation Table SB4 Physical Characteristics and Environmental Specifications Lead material Matte tin finish (-L devices) Encapsulating material Epoxy, meets UL94V-0 requirements Solderability per MIL-STD-750, Method 2026 Solder heat withstand per MIL-STD-750, Method 2031 Solvent resistance per MIL-STD-750, Method 1022 Mechanical shock per MIL-STD-750, Method 2016 Vibration per MIL-STD-750, Method 2056 Storage temperature ( C) -55 to 150 Operating temperature ( C) -40 to 125 Junction temperature ( C) 175 Maximum Lead Temperature for Soldering Purpose; for 10s ( C) 260 Table SB5 Reliability Tests Test Conditions Duration High temperature, reverse bias +100 C, 50VDC bias 1000 hours High humidity, high temperature, reverse bias 85% RH, +85 C, 50VDC bias 1000 hours High temperature storage life +150 C 1000 hours Temperature cycling -65 C to +150 C, 15 minute dwell 1000 cycles Autoclave 100% RH, +121 C, 15 PSI 96 hours 2007 Tyco Electronics Corporation. All rights Reserved. 3 Rev: B Date: DECEMBER 12, 2007

2007 Tyco Electronics Corporation. All rights Reserved. 4 Rev: B Date: DECEMBER 12, 2007

Table SB6 Packaging and Marking Information Recommended Pad Layout (millimeters/inchs) Part Description Tape and Reel Quantity Standard Package Part Marking A (Nom.) B (Nom.) C (Nom.) Agency Recognition* TVB058NSA-L 2,500 10,000 58NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB065NSA-L 2,500 10,000 65NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB075NSA-L 2,500 10,000 75NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB090NSA-L 2,500 10,000 90NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB120NSA-L 2,500 10,000 12NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB140NSA-L 2,500 10,000 14NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB170NSA-L 2,500 10,000 17NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB180NSA-L 2,500 10,000 18NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB190NSA-L 2,500 10,000 19NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB220NSA-L 2,500 10,000 22NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB275NSA-L 2,500 10,000 27NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL TVB320NSA-L 2,500 10,000 32NA 2.261 (0.089) 2.159 (0.085) 2.743 (0.108) UL * UL497B, File # E179610 308 Constitution Drive, MS R21/2A Tel (800) 227-7040 www.circuitproection.com Menlo Park, CA USA 94025-1164 (650) 361-6900 www.circuitprotection.com.hk (Chinese) Fax (650) 361-2508 www.circuitprotection.jp (Japanese) Raychem, PolySwitch, SiBar, TE Logo and Tyco Electronics are trademarks. All other trademarks and copyrights are property of their respective owners. 2007 Tyco Electronics Corporation. All rights Reserved. 5 Rev: B Date: DECEMBER 12, 2007