AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Similar documents
AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

AS/NZS :2014

AS/NZS 3190:2011 AS/NZS

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

AS/NZS :2008

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

AS/NZS 3133:2008 AS/NZS

AS/NZS :2014

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

Australian/New Zealand Standard

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

AS/NZS 4012:1999 AS/NZS

AS/NZS :2014

Australian/New Zealand Standard

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

AS/NZS 3957:2006 AS/NZS

AS/NZS 4234:2008 AS/NZS

Australian/New Zealand Standard

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS IEC :2015

Australian/New Zealand Standard

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

AS/NZS :2015

Australian/New Zealand Standard

AS/NZS :2016

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016

AS/NZS IEC 62560:2014

AS/NZS IEC :2013

AS/NZS :1998 AS/NZS ISO

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

AS/NZS :2014

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

Australian/New Zealand Standard

Household and similar electrical appliances Safety

Australian/New Zealand Standard

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

Substations and high voltage installations exceeding 1 kv a.c.

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Australian/New Zealand Standard

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

Australian/New Zealand Standard

AS/NZS IEC :2016

AS/NZS :2009

AS/NZS TR IEC :2012

Australian/New Zealand Standard TM

AS AS Australian Standard. Installation of fire hose reels. This is a free 6 page sample. Access the full version online.

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

Australian/New Zealand Standard

Australian/New Zealand Standard

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

AS/NZS ISO/IEC :2012

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

AS/NZS 2: 1067:2003 AS/NZS

Interim Australian Standard

Australian Standard. Security screen doors and security window grilles AS AS 5039

Australian/New Zealand Standard

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

AS/NZS IEC :2016

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

AS/NZS TR IEC :2012

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

AS/NZS IEC :2014

AS AS Australian Standard. Soils for landscaping and garden use. This is a free 7 page sample. Access the full version online.

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

Australian/New Zealand Standard

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

Australian/New Zealand Standard

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

Australian Standard. Safeguarding of machinery

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

NZS 7901:2014. Electricity and gas industries Safety management systems for public safety NZS 7901:2014. New Zealand Standard

Medical electrical equipment

AS/NZS :2017. Explosive atmospheres AS/NZS :2017. Part 14: Design selection, erection and initial inspection

Transcription:

AS/NZS 2290.1:2014 Australian/New Zealand Standard Electrical equipment for coal mines Introduction, inspection and maintenance Part 1: For hazardous areas Superseding AS/NZS 2290.1:2005 AS/NZS 2290.1:2014

AS/NZS 2290.1:2014 This joint Australian/New Zealand standard was prepared by Joint Technical Committee EL-023, Electrical Equipment for Mines and Quarries. It was approved on behalf of the Council of Standards Australia on 3 December 2013 and on behalf of the Council of Standards New Zealand on 12 December 2013. This standard was published on 11 February 2014. The following are represented on Committee EL-023: Australian Cablemakers Association Australian Chamber of Commerce and Industry Australian Coal Association Australian Industry Group Aviation and Marine Engineers Association Consult Australia Department of Mines and Petroleum, WA Department of Natural Resources and Mines, Qld Mining Electrical and Mining Mechanical Engineering Society Ministry of Business, Innovation and Employment, New Zealand National Association of Testing Authorities Australia NSW Department of Trade and Investment, Regional Infrastructure and Services University of Newcastle WorkCover New South Wales Keeping standards up to date Standards are living documents which reflect progress in science, technology, and systems. To maintain their currency, all standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current standard, which should include any amendments which may have been published since the standard was purchased. Detailed information about joint Australian/New Zealand standards can be found by visiting the standards webshop at www.standards.com.au or Standards New Zealand s website at www.standards.co.nz. Alternatively, Standards Australia publishes an annual printed catalogue with full details of all current standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national standards organisation. We also welcome suggestions for improvement in our standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the title page. This standard was issued in draft form for comment as DR AS/NZS 2290.1.

AS/NZS 2290.1:2014 Australian/New Zealand Standard Electrical equipment for coal mines Introduction, inspection and maintenance Part 1: For hazardous areas Originated in Australia as AS 2290.1 1979. Previous edition AS/NZS 2290.1:2005. Fourth edition 2014. COPYRIGHT Standards Australia Limited/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher, unless otherwise permitted under the Copyright Act 1968 (Australia) or the Copyright Act 1994 (New Zealand). Jointly published by SAI Global Limited under licence from Standards Australia Limited, GPO Box 476, Sydney, NSW 2001 and by Standards New Zealand, Private Bag 2439, Wellington 6140. ISBN (Print) 978-1-77551-239-4 ISBN (PDF) 978-1-77551-240-0

AS/NZS 2290.1:2014 2 PREFACE This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-023, Electrical Equipment for Mines and Quarries, to supersede AS/NZS 2290.1:2005, Electrical equipment for coal mines Introduction and maintenance, Part 1: For hazardous areas. The objective of this Standard is to facilitate the safe, efficient and productive use of electrical explosion-protected equipment and cables in underground coal mine hazardous areas, by specifying requirements and recommendations for the inspection and maintenance of such equipment. This Standard is part of a series of standards on the maintenance and overhaul of electrical equipment used in association with underground mining machines. The series is as follows: (a) AS/NZS 2290.1, Electrical equipment for coal mines Introduction and maintenance, Part 1: For hazardous areas (this Standard). (b) AS 2290.3, Electrical equipment for coal mines Maintenance and overhaul, Part 3: Maintenance of gas detecting and monitoring equipment. In addition, this Standard aligns with AS/NZS 3800:2012, Electrical equipment for explosive atmospheres Repair and overhaul. The principal differences between this edition and the 2005 edition are as follows: (i) Life-cycle management of explosion-protected equipment has been embraced. (ii) The range of inspections has been expanded to include initial and periodic inspections. (iii) A risk-based process is required for the identification of readily accessible components and the determination of inspection frequency ; however, recommended inspection schedules for individual explosion-protection techniques have been retained. (iv) An electrical engineering manager has been specified as the process owner and responsible decision maker. (v) General inspection requirements that are applicable to all explosion-protection techniques have been included. (vi) The range of explosion-protection techniques has been expanded to address currently installed equipment. (vii) This Standard has been aligned with the AS/NZS 60079 series, where compatible with Group I requirements. (viii) An alternate risk assessment method encompassing equipment protection levels (EPLs) for Ex equipment is discussed in an informative appendix. NOTE: See Appendix M. The term informative has been used in this Standard to define the application of the appendix to which it applies. An informative appendix is only for information and guidance. Statements expressed in mandatory terms in footnotes to tables are deemed to be requirements of this Standard.

3 AS/NZS 2290.1:2014 CONTENTS Page FOREWORD... 5 SECTION 1 SCOPE AND GENERAL 1.1 SCOPE... 6 1.2 NORMATIVE REFERENCES... 6 1.3 DEFINITIONS... 7 SECTION 2 GENERAL REQUIREMENTS 2.1 LIFE CYCLE MANAGEMENT... 10 2.2 DOCUMENTATION... 11 2.3 COMPETENCY... 12 2.4 INSPECTIONS... 13 2.5 INITIAL INSPECTION REQUIREMENTS... 15 2.6 PERIODIC INSPECTION REQUIREMENTS... 16 2.7 PRE-OVERHAUL AUDIT REQUIREMENTS... 17 2.8 MAINTENANCE REQUIREMENTS... 19 2.9 ENVIRONMENTAL CONDITIONS... 20 2.10 ISOLATION OF EQUIPMENT... 20 2.11 EARTHING AND EQUIPOTENTIAL BONDING... 21 2.12 SPECIFIC CONDITIONS OF USE... 22 2.13 MOBILE, PORTABLE AND TRANSPORTABLE EQUIPMENT AND ITS CONNECTIONS... 22 2.14 GENERAL INSPECTION REQUIREMENTS... 22 SECTION 3 SPECIFIC INSPECTION REQUIREMENTS 3.1 GENERAL... 25 3.2 TYPE OF PROTECTION d FLAMEPROOF ENCLOSURE... 25 3.3 TYPE OF PROTECTION e INCREASED SAFETY... 30 3.4 TYPE OF PROTECTION i INTRINSIC SAFETY... 31 3.5 TYPE OF PROTECTION p PRESSURIZED ENCLOSURE... 36 3.6 TYPE OF PROTECTION m ENCAPSULATION... 37 3.7 TYPE OF PROTECTION o OIL-IMMERSION... 37 3.8 TYPE OF PROTECTION q POWDER-FILLING... 37 3.9 TYPE OF PROTECTION s SPECIAL PROTECTION... 37 3.10 EXPLOSION PROTECTED CAPLIGHTS... 38

AS/NZS 2290.1:2014 4 Page APPENDICES A INSPECTION FLOWCHART... 39 B CORROSION OR SURFACE INDENTATION TOLERANCES... 40 C TYPICAL METHOD FOR TEMPORARY, IN SITU REPAIR OF A DAMAGED HOLE OR THREAD IN A FLAMEPROOF ENCLOSURE... 42 D DOCUMENTATION CHECK SHEET TYPICAL FORMAT... 44 E TYPICAL EXTERNAL INSPECTION REPORT FORM Ex d... 45 F TYPICAL INTERNAL INSPECTION REPORT FORM Ex d... 46 G TYPICAL EXTERNAL INSPECTION REPORT FORM Ex e... 48 H TYPICAL INTERNAL INSPECTION REPORT FORM Ex e... 49 I TYPICAL EXTERNAL INSPECTION REPORT FORM Ex i... 51 J TYPICAL INTERNAL INSPECTION REPORT FORM Ex i... 52 K TYPICAL EXTERNAL INSPECTION REPORT FORM Ex p... 53 L TYPICAL PRE-OVERHAUL AUDIT REPORT SHEET... 54 M INTRODUCTION OF AN ALTERNATIVE RISK ASSESSMENT METHOD ENCOMPASSING EQUIPMENT PROTECTION LEVELS FOR Ex EQUIPMENT... 55 BIBLIOGRAPHY... 60

5 AS/NZS 2290.1:2014 FOREWORD Electrical installations in hazardous areas have features specially designed to make them suitable for operation in such areas. For safety reasons, it is essential that the integrity of those special features is maintained throughout the life of the installations. Therefore they require an initial inspection and regular periodic inspections by competent persons in accordance with this Standard. NOTE: Correct functional operation of hazardous area installations does not mean, and should not be interpreted as meaning, that the integrity of the special features referred to above is preserved. The use of this Standard and safe electrical engineering practice will assist in the management of electrical hazards. The implementation of this Standard will contribute significantly to the (a) prevention of ignition of explosive gases or dusts; (b) prevention of electric shock and burns; (c) prevention of arcing faults that have sufficient energy to invalidate the type of explosion-protection as a result of damage to the enclosure or generation of an excessive pressure rise beyond that for which the electrical enclosure was designed; and (d) prevention of fires caused by the malfunction of electrical equipment. The risk management process should be utilized to identify relevant controls. There are a number of controls associated with using electricity in hazardous areas, including the following: (i) Fit-for-purpose electrical explosion-protected equipment. (ii) Fit-for-purpose cables for hazardous areas in a mining environment. (iii) Fit-for-purpose electrical protection. (iv) Fit-for-purpose earthing systems. (v) Reduction of the potential for phase-to-phase arcing faults. (vi) Fit-for-purpose lightning protection. (vii) Fit-for-purpose tools and test equipment. (viii) Isolation and electrical testing procedures. (ix) Removal/restoration of power procedures. (x) Proper classification of hazardous areas. (xi) Correct first aid treatment for persons who receive an electric shock and burns. This Standard covers many of these particular aspects, but also takes a holistic approach to the electrical system and recognizes that many of the controls interact and that each of the life cycle stages interact. It is up to the user of this Standard to make judgements and decisions with all of this in mind.

AS/NZS 2290.1:2014 6 STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Australian/New Zealand Standard Electrical equipment for coal mines Introduction, inspection and maintenance Part 1: For hazardous areas SECTION 1 SCOPE AND GENERAL 1.1 SCOPE This Standard sets out requirements for the inspection and maintenance of electrical equipment designed for use in hazardous areas in and around underground coal mines. Section 2 provides general requirements that are fundamental to the safe use of electrical equipment in hazardous areas. Section 3 provides specific requirements for each type of explosion-protection technique. This Standard is intended to be applied where there is a potential risk due to the presence of explosive gas, dust mixtures and combustible dust layers. It does not apply to (a) surface infrastructure, typically Group II or Group III classified areas, other than gas drainage and borehole dewatering areas that could negatively impact on an underground mine workings; (b) areas where a risk can arise due to the presence of hybrid mixtures; (c) areas where small quantities of flammable materials are introduced for maintenance purposes; or (d) shotfiring activities and associated equipment. This Standard does not include (i) electrical installation and inspection requirements not directly associated with an explosion-protection technique; (ii) the regulatory compliance assessment of electrical equipment; or (iii) the permanent repair, reclamation and overhaul of explosion protected equipment. 1.2 NORMATIVE REFERENCES The following are the normative documents referenced in this Standard. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE: Documents for informative purposes are listed in the Bibliography. AS/NZS 3000 Electrical installations (known as the Australian/New Zealand Wiring Rules) 3800 Electrical equipment for explosive atmospheres Repair and overhaul 4761 Competencies for working with electrical equipment for hazardous areas (EEHA) (series) 4801 Occupational health and safety management systems Specification with guidance for use COPYRIGHT

AS/NZS 2290.1:2014 Electrical equipment for coal mines - Introduction, inspection and maintenance - Part 1: For hazardous areas This is a free sample only. Purchase the full publication here: https://shop.standards.govt.nz//catalog/2290.1%3a2014%28as%7cnzs%29/view Or contact Standards New Zealand using one of the following methods. Freephone: 0800 782 632 (New Zealand) Phone: +64 3 943 4259 Email: enquiries@standards.govt.nz