Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Similar documents
Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Air Conditioner User Manual

EVAPORATIVE AIR COOLER SERVICE MANUAL

Dehumidifier Owner s Manual Read and save these instructions before use

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Portable Air Conditioner User Manual Read and save these instructions before use

Thanks for shopping with Improvements! Evaporative Air Cooler with Adjustable Flow Valve Item #437979

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

OWNER'S MANUAL. 101-Pint Commercial Indoor Portable Evaporative Cooler. Model: SF-48LB. Read and save these instructions before use

Operating Instructions

If you have any problems with this product, please call BEFORE returning it to your retailer.

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

Honeywell Portable Air Conditioners. A compact, easy to use portable cooling solution.

JMATEK North America LLC Mahwah, New Jersey USA Phone: Web:

Please read all these instructions carefully before using this product.

Arctic EVAPORATIVE COOLER USER MANUAL

EVAPORATIVE AIR COOLER Instruction Manual

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Agrifim A675CT Timer. Frequently Asked Questions

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

10L Evaporative Cooler with Timer

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

5) Do not start or stop the unit by inserting or pulling out the power plug.

Stand Fan. English. Owner s Guide. Model F R

AF-1000 Series. Evaporative Cooler. OWNER S MANUAL v1.0. Read and save these instructions.

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Portable Air Conditioner Instruction Manual

EVAPORATIVE COOLER W

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

AC-12200E Portable Air Conditioner


AF-1000 Series Evaporative Cooler OWNERS MANUAL

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Portable Air Conditioner USER MANUAL

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Contents. Functions READ AND SAVE THIS INSTRUCTION MANUAL. Air Cooler. Model SF-608R

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Dr. Infrared Heater Elite Series

Portable Air Conditioner

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

SPECIFICATIONS PART NAME

40cm Pedestal Fan with Remote Control

Air Purification System. Instruction Book CLI-AP20

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Mobile Air Conditioner Instruction Manual Model TC-N9KM

2.4kW Ceramic Heater Model: DHCER24SW

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Portable Air Conditioner

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

IMPORTANT INSTRUCTIONS READ & SAVE

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

ACCESSORIES INCLUDED

Owner's Manual TABLE OF CONTENTS

Trotec PAC FT 2600 Portable air conditioner

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Reverse Cycle Split System Air Conditioner

Operation and Maintenance Manual 120V/60HZ

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

Portable Air-conditioner

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

EVAPORATIVE AIR COOLER

Transcription:

Portable Evaporative Air Cooler User Manual Read and save these instructions before use Scan here: www.honeywellaircoolers.com www.jmatek.com E-mail: usinfo@jmatek.com Model: CL70PE / CO70PE

PARTS DESCRIPTION (3) (1) (2) (10) (11) (12) (4) (8) (6) (7) (13) (15) (14) (16) (5) (9) 1) Control Panel 2) Handle 3) Louvers 4) Water Level Indicator 5) Casters 6) Ice Compartment Lid 7) Power Cord Wrap 8) Water Tank 9) Power Cord & Plug 10) Plastic Net Filter 11) Rear Grill Screw 12) Honeycomb Cooling Media (17) 13) Rear Grill 14) Water Regulator 15) Water Fill Door 16) Water Inlet Valve 17) Drain Plug WARNING -- READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL. WARNING: FOR OUTDOOR MODEL CO70PE, USE ONLY ON GFCI PROTECTED RECEPTACLES. USE & OPERATION CONTROL PANEL Icons on Display Screen S SWING(V) C H M L 0.5 1 2 4 Swing (Vertical Louvers) Power MODE SPEED POWER TIMER SWING(H) Cool Timer Speed FUNCTION BUTTONS POWER Press the POWER button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again. MODE Press the MODE button to activate evaporative cooling and/or louver swing modes. Press the MODE button until the S indicator light is illuminated on the control panel. The Vertical Louvers will begin to move left to right automatically. Swing (Horizontal Louvers) Press the MODE button until the C indicator light is illuminated to activate evaporative cooling. The water pump will operate and you will feel the cooler air after the Honeycomb Cooling Media is completely wet. LOUVER MOVEMENT EN 1

USE & OPERATION (CONTINUED) FUNCTION BUTTONS (CONTINUED) Pressing the MODE button until both S and C are illuminated will activate both Swing (Vertical Louvers) and Cool modes simultaneously. Note: When the C mode is not selected, the unit functions in a fan only mode, without evaporative cooling. SPEED Press the SPEED button repeatedly to change the speed between High - Medium - Low. The indicator light will show the selected speed: High (H) Medium (M) Low (L) TIMER Press the TIMER button until the desired time duration setting is selected. When the set time has passed, the unit will automatically turn off (unit remains in Standby mode until power cord is unplugged from electrical socket). The TIMER function allows you to program the unit for up to 7.5 hours of use. SWING(H) Press the SWING (H) button until the indicator light turns on. This activates the Horizontal Louvers and they will begin to move up and down automatically. LOUVER MOVEMENT ROOM COOLING AND HUMIDIFYING In cooling mode, Honeywell Air Coolers provide cool, moist air through the evaporation of water. There is a manual Water Regulator knob located behind the ice compartment of the unit. This allows you to adjust the amount of water pumped over the Honeycomb Cooling Media, thus helping to control cooling and humidification levels. When the Water Regulator is set to MIN, the water pump distributes a minimal amount of water to the Honeycomb Cooling Media. This results in less water evaporation and reduces the cooling effect. Water Regulator MAX MIN When the Water Regulator is set to MAX, the water pump distributes the maximum amount of water to the Honeycomb Cooling Media. This results in maximum water evaporation and greater cooling performance. REMOTE CONTROL ON/OFF SWING (H) TIMER MODE SPEED POWER : ON / OFF SWING : Controls the motion of the horizontal louvers TIMER : Controls the Timer function for automatic off MODE : Controls the motion of the vertical louvers and evaporative Cooling On / Off SPEED : Low / Medium / High EN 2

USE & OPERATION (CONTINUED) REMOTE CONTROL (CONTINUED) Note: The remote control requires AAA (2 x 1.5V) batteries for replacement. Open the battery compartment at the back of the remote control and insert the batteries inside. Care must be taken to insert the batteries according to the correct polarity (+ / ) markings shown inside the battery compartment. Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed. Remove the batteries if the unit is not going to be used for an extended period of time. Do not drop the remote control. Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries. Do not mix old and new batteries. Do not recharge the battery. Exhausted batteries are to be removed from the product and safely disposed of as per local regulations. Do not dispose of batteries in fire. Batteries may explode or leak. WARNING: Caution for ingestion of the small battery. Keep away from children and animals. COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide. FILLING WITH WATER It is ideal to use the Continuous Water Supply Connection to run the unit for long periods of time without refilling the tank. This also helps prevent pump failure in case the cooler is running with inadequate water in the tank. CAUTION: Unplug the unit from the electrical power outlet before filling or emptying the water tank. Continuous Water Supply Connection: For a continuous water supply, you will need a garden hose that is connected to a main water supply. Locate the male connector at one end of the garden hose. Insert the garden hose connector into the water inlet valve of the cooler. Screw and tighten the water inlet valve onto the threaded part of the garden hose connector, making sure the hose connector is secured to ensure there will be no leaks. If there is leakage, the hose and the water inlet valve may not be connected properly. Try to disconnect, replace and tighten the water inlet valve again. When the connection is secured, turn ON the water supply and the water will flow into the water tank of the cooler. The cooler is now set so the water refills automatically when the water tank is empty, or when the water reaches below a minimum level. When the water tank is full, the water inlet valve will automatically stop the water supply from overflowing. WARNING: The maximum water inlet pressure is 0.5 MPa. Water Inlet Valve Garden Hose EN 3

USE & OPERATION (CONTINUED) FILLING WITH WATER (CONTINUED) Manual Water Tank Refill: Open the Water Fill Door located on the side of the unit. The Water Level Indicator is located at the front of the unit. Refill the water tank when water level is low. Do not fill water above the "Max." water level mark to avoid water droplets collecting on the louvers. Check the water level in the tank before running the COOL function. Make sure that the water in the tank is above the minimum water level mark. Running the unit in COOL mode with inadequate water may cause pump failure. Water Fill Door WARNING: Always ensure the water in the water tank is above the minimum (Min.) water level mark for both Continuous & Manual Water Refill. Running the unit in Cool mode with inadequate water may cause pump failure. Note: The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system. The water capacity in the tank at the Max. indicator level may be lower than the actual water capacity of the air cooler. Ice Tray Note: If ice is available, you may add ice in the ice tray to enhance the cooling performance. WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and Honeycomb media. LOW WATER ALARM* The unit is equipped with a low water sensor. In Cooling Mode, when water in the tank is below the minimum level, you will hear a beeping sound and the indicator light will flash continuously. The unit will automatically pause evaporative cooling. Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch ON again. To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty. *Applicable for models with Low Water Alarm feature only. EN 4

USE & OPERATION (CONTINUED) CLEANING & DRAINING THE WATER TANK If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide. WARNING: Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket. Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty. Refill the water tank with clean water, up to the maximum level and drain it completely. Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product. When the product is not in use, store the unit in a dry place out of direct sunlight. CLEANING THE PLASTIC NET FILTER* AND HONEYCOMB COOLING MEDIA The appliance is supplied with a Plastic Net Filter* and Honeycomb Cooling Media. The Plastic Net Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance. Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time. The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs. For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off. Figure 1: Plastic Net Filter Honeycomb Cooling Media Screws Horizontal Bar Rear Grill Screws Removing the Plastic Net Filter*/ Honeycomb Cooling Media: WARNING: Switch the unit OFF and disconnect from the electrical socket. 1. Slide out the Plastic Net Filter* and clean with water. 2. Remove all the screws from the Rear Grill of the Air Cooler. 3. Carefully pull out the rear grill from the cooler. 4. Carefully pull out the Honeycomb Cooling Media from the rear grill. 5. There are two Horizontal Bars holding the Honeycomb Cooling Media in place. Remove all the screws from the Horizontal Bars and then pull the bars off of the Honeycomb Cooling Media. 6. Replace or clean media with water and a damp cloth as needed. WARNING: DO NOT operate the Air Cooler when the Rear Grill or Honeycomb Media is removed from the Air Cooler, or if there is a loose-fitting Rear Grill or Honeycomb Cooling Media. Doing so can cause serious injury or dangerous electrical shock. EN 5 *Applicable for models with Plastic Net Filter only.

TECHNICAL SPECIFICATIONS Model CO70PE Voltage 110-120 V Frequency 60 Hz Ampere 2.4 A Wattage 280 W Cooling Media Honeycomb Product Dimension 706 (W) x 426 (D) x 1008 (H) mm 27.8 (W) x 16.8 (D) x 39.7 (H) in Net Weight 18.5 kg / 40.8 lbs ELECTRICAL WIRING DIAGRAM For USA Outdoor Models Only. This appliance is equipped with a GFCI plug. Press the TEST button and then the RESET button once every month to ensure proper operation. Version: 110-120V/60Hz COOL SWING Capacitor M PUMP M ~ PLUG L N H M L Transformer COOL PCB1 OSC M HOR PCB2

JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to these products. This product is manufactured by Airtek Int'l Corp. Ltd. (subsidiary of JMATEK Ltd.)