USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

Similar documents
Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

360º Surface Mount Ceiling PIR Light Controller

5W LED Energy Saver PIR Bulkhead

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

60W Multi PIR Bulkhead

360 Ceiling PIR Light Controller

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

CONTENT. Ⅰ General information 1. Ⅱ Product description 2. System description 3. Installation 3

Digital Room Thermostat with Night Set-back

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

AB Can Beverage Cooler

High Frequency Sensor

Infrared Wall Mount Occupancy Sensor

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Integrated PIR detectors

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

AB Can Beverage Cooler

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

CEILING FAN OWNER'S MANUAL

IR Intelligent Speed Dome Installation Manual

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

Installation and Instruction Manual

Imperial Electric Fires

OWNER S MANUAL ABSFBM-200T

User Manual 120/240/300 Outdoor Motion Detector

1. Basic safety information 3 2. Proper use 3

LA type soldering iron controller

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Security Light Transmitter

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

CEILING FAN OWNER'S MANUAL

LPCMPIRM65 & LPCMPIRDSI65

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Room Sensor [RBT-3C] Installation Instructions

Emergency Assist Alarm Kit Single Zone

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

User instructions and quick-fit guide

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

IR Intelligent Positioning System Installation Manual

LPC3BSP65 & LPC3BDP65

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

Ceiling PIR HS presence detector. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

TH100 Three in One Instant Hot Water Tap

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

, ,

Installation and Homeowners Guide

AB-WINE18S Thermoelectric Wine Cooler OWNER S MANUAL Read and save these instructions.

ELSTON 52 CEILING FAN

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

INSTALLATION GUIDE NZ AU C

52 BERKSHIRE CEILING FAN

FerronTM. Instruction Manual A Kichler Decor ceiling fan

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

52 STRATHMERE CEILING FAN

INSTALLATION AND INSTRUCTION MANUAL

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

VADA - Rain2Main Automatic Rainwater Controller

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

SHORT WAVE INFRARED PANEL DRYER

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Intelligent Speed Dome Installation Manual. Version 1.0.0

48 TAYLOR CEILING FAN

CEILING FAN OWNER'S MANUAL

Hardwired Electric Garage Heater

identity installation & maintenance instructions customer/technical services guarantee

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

52 CEILING FAN. Owner s Manual Models #50336, 50337

PRO Series Energy Star Ceiling Fan Owner's Manual

IR Intelligent Speed Dome Installation Manual

Ceiling Fan Installation Instructions

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

Closomat Lima Vita installation & user guide

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MightyMax Tower Fan MIGHTY POWERFUL. MIGHTY QUIET.

e Bath Fan with Light User s Guide

INSTALLATION AND USER MANUAL

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Transcription:

Model #NW520 USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP? Questions, problems, missing parts? Before returning to the store call Nightwatcher Customer Service: 0845 900 6764 Or Email: support@nightwatchersecurity.co.uk THANK YOU We appreciate the trust and confidence you have placed in Nightwatcher through the purchase of this motorised LED flood light. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Nightwatcher!

INSTALLATION INSTRUCTIONS Read all instructions before proceeding with the installation OVERVIEW OF NW520 IMPORTANT: THE INTALLATION OF THIS FITTING MUST BE DONE BY A QUALIFIED ELECTRICIAN. This fitting must be earthed. Do not mount the luminaire against inflammable surfaces. The motion detector will not operate correctly if it is installed: ( Ⅰ) Near the outlet of a central heating boiler ( Ⅱ) an air Near conditioning plant WARNING!!! ( Ⅲ) Pointing directly at moving vehicles BEFORE ATTEMPTING ANY INSTALLATION OR MAINTENANCE, ENSURE THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF AND THE CIRCUIT FUSES REMOVED OR THE CIRCUIT BREAKER IS IN THE OFF POSITION. ( Ⅳ) Within sight of reflection from moving water ( Ⅴ) W here other lamps could shine onto the detector NOTE: This highly responsive unit may occasionally activate due to rapid environmental changes. 30 seconds warm-up time before the sensor resumes normal activity. Allow for approximately MOUNTING THE FITTING To ensure correct operation of the sensor, mount the luminaire that traffic passes across the detector. TOP VIEW GOOD SENSITIVITY LESS SENSITIVITY 2 www.nightwatchersecurity.co.uk

INSTALLATION AND WIRING INSTRUCTIONS Remove the inset back mounting box from the luminaire. Fit the inset back mounting box onto the wall and tighten the screws at a height that ensures adequate coverage of the area by the infrared detector. The minimum installation height is 2 meters. And the maximum height is 3 meters. *Please make sure the voltage and polarity are correct before connection. Incorrect voltage may cause an electric shock. If you are not sure, please contact your retailer or a qualified electrician. NOTE: DO NOT REMOVE THE SECURING TAPE ON THE FITTING UNTIL THE UNIT IS FULLY INSTALLED. WIRING INSTRUCTIONS Feed the cable carefully through the back mounting box and bush to avoid abrasion to the cable. Connect the earth wire to the connector opposite the green/yellow cable. Connect the brown phase conductor active to the connector opposite the brown cable and tighten the screws. Connect the blue neutral conductor to the connector opposite the blue cable and tighten the screws. Check that all connections are correct and tight, as any misconnections will damage the detector. Re-fit the fitting to the back mounting box. 3 www.nightwatchersecurity.co.uk

FUNCTION This light is equipped with 3 motion sensors: zone 1 covers 60 degree, zone 2 covers 100 degrees and zone 3 covers 60 degrees. 220 degrees (maximum) in total for 3 zones. ZONE 2 ZONE 1 ZONE 3 TOTAL DETECTION RANGE The light will switch on for 3 minutes and off automatically when heat/ movement is detected. The factory default: the light on is fixed at 3 minutes and is set to Night-time mode. To change the mode to All Day Mode, push the button at the bottom of the housing and the hidden LED indicator will turn off under this mode. The light will be on at 3 minutes when detecting any movement at day and night. for programmable functions: - All day mode: light works on day and night - Night-time mode: light works at night only Reset function: If the stepper motor of tracking light is working abnormally, the hidden LED indicator will flash red and the light will stop turning automatically. In All Day mode, the red light will flash for 5 seconds and off for 5 seconds; in Night-time mode, the red light will flash in the regular pattern. Please simply switch the mains power off and on to reset the tracking light. Below are the possible abnormal situations; - External force: the light head is blocked by objects or is blown by strong wind and is unable to turn properly, the hidden LED will flash in red to signal users the abnormal situation. - Stepper Motor : when the stepper motor is reaching the end of its life or is damaged, the bottom hidden LED will flash red to signal a malfunction. Please switch the NW520 off and on at the mains, the tracking light now may or may not resume operation. If the stepper motor stops working and is outside the standard warranty period, the NW520 will continue to function as a regular motion sensor security light. Left 70 Right 70 Hidden LED indicator 4 www.nightwatchersecurity.co.uk

OPERATION 1. Turn on the wall switch to activate the light, the light is now under Night-time mode NOTE: Allow approximately 30 seconds warm-up time before the sensor resumes normal activity. 2. To test, walk through the sensor s detection area. 3. After the light is activated, keep out of detection area and the light will switch off automatically after 3 minutes. The light will be activated again when detecting any movement. If there is continuing movement in the detection zone, the light will stay on until movement ceases. (after 3 minutes) NOTE: THE INTELLIGENT MOTION SENSOR TRACKING LIGHT IS DESIGNED TO ILLUMINATE WHEN THE DETECTION AREA IS ENTERED BY A PERSON AND WILL DETECT MOVING HEAT SOURCE. THERE IS NO GUARANTEE IMPLIED THAT IT WILL PROVIDE TOTAL SECURITY OR PREVENT ILLEGAL ENTRY. SPECIFICATION Detection method: Sensor range: Power source: Time adjustment: Passive Infrared Sensor (with continuous detect function) 10m x 210 (maximum) AC 240V 50Hz Fixed at 3 minutes approx. 5 www.nightwatchersecurity.co.uk