Fiber Optic Patch Cord and Pigtails

Similar documents
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Fibre Specification Standards

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

FiberExpress Solutions

Duct Cable GYTS-144B1.3

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Qualification Test Report LC Duplex Adapter For LC Cutouts

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Apr06 Rev A

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

ITU-T L.404. Field mountable single-mode optical fibre connectors

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

HELKAMA. Optical Fibre Cables

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Best Practice Briefing

MT-RJ Optical Fiber System Field Testing

Fiber Optic Distribution Cables (6-144 Fibers)

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Connections You Can Count On.

Ensuring Cabling Performance in the Customer-Owned Outside Plant

The True Value of Connector Inspection: New Challenges and Best Practices

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

DNVGL-CP-0402 Edition February 2016

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

STANDARD CONFORMANCE

Fiber Optic Products Catalog

Core Alignment All In One Fusion Splicer

Special Provision No. 683S28 December 2017

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Jan07 Rev B

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Basic Professional Fiber Optic Installation

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

The Rise of Tier 2 Testing

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies


Fibre (TIA) Field Test Specification

Product Specification Qualification Test Report

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

M700-Series Multifunction OTDR

Application Engineering Note. Importance of Jacket Crimping

LSH (E 2000 ) High performance. High reliability. High safety. High flexibility

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Clearlite Photonic Fibers

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AS/NZS ISO/IEC :2012

VIEW500 USER-FRIENDLY STANDARD OTDR

M310 Data Center OTDR

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

VIEW500 FASTEST STANDARD OTDR

Hands-On CAT 5/6 & Fiber Optic Installer

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

M210 Multifunction Micro OTDR

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

M210 Multifunction Micro OTDR

MINI2 MOST ACCURATE COMPACT OTDR

/Mar/2014 Rev A

INTERNATIONAL STANDARD

Noyes OFL 250B Specs Provided by

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Fujikura-70S Single Fibre Fusion Splicer

White Paper Fiber optic connections: check and clean first, then connect!

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

4120 Fire Alarm Network Reference

OPTICAL FIBER JOINTS & CONNECTIONS

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Transcription:

Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable devices featuring low insertion loss and high return loss. The patch cords come with your choice of simplex or duplex cable configurations and various cords of style. Application High Speed Digital System Cards DWDM Application Optical communication systems Optical instrument Features FC/SC/LC /ST/MTRJ/MU/E2000/MPO/D4/DIN/SMA/FDDI/ESCON connector optional Comply with IEC, ITU-T, ETSI recommendations and Telcordia standards.. Low insertion loss:not more than 0.2dB for both APC and UPC High return loss: UPC>-55dB APC>-65dB All models of cables optional, all kinds of combinations Superior qualified standard PC/SPC/UPC/APC polishing 0.9mm.2.0mm.3.0mm and all diameter cable are available Single mode or multi modes Simplex/duplex patch cord available 100% optic test (insertion loss and return loss)

The bending radius: 25mm or less. The service life of the connector: more than 1000 mate/ demate cycles without any degradation of the transmission quality. Ambient temperature range from -40 o C to 80 o C and humidity up to 95% non-condensing. Construction and Material (Single Mode Fiber Cable) The optical fiber conforms to the requirement of ITU-T Recommendation G.652D. PARAMETER SPECIFICATION 1. Mode Field Diameter 8.6 to 9.5 μ m at 1310nm 2. Cladding diameter 125 μ m±1.0 μ m 3. Mode Field Concentricity Error Less than 0.6 μ m 4. Cladding non-circularity Less than 1% 5. Cable cut-off Wavelength ( λ cc) Less than 1260nm 6. Polarization mode dispersion(pmd) 0.2ps/km 7. Attenuation coefficient Less than 0.35dB/km at 1310nm Less than 0.35dB/km at 1383nm Less than 0.21dB/km at 1550nm Less than 0.23dB/km at 1625nm 8. Proof stress More than 0.69GPa 9. Maximum attenuation with macro Less than 0.10 db at 1550nm bending 100 turns 30mm radius Buffer: tight buffer and white color

Protective Member: made of polaramid (Kevlar) Sheath: Fire retardant sheath fire retardant sheath, yellow halogen-free, Smooth, colored uniformly and free of crack, hole and stain. Item Dia. Of Buffered fiber Min. thickness of sheath Overall Dia Dimension(mm) 0.9 0.4 3.0±0.2 CONNECTOR The structure and dimension of the ferrules are complying with the following standards: CONNECTOR TYPE APPLICABLE STANDARD 1. FC IEC 61754-13(2006-02) Ed. 2.0 2. LC IEC 61754-20(2002-08) Ed. 1.0 3. SC IEC 61754-4(2002-03) Ed. 1.2 4. ST IEC 61754-20(2002-08) Ed. 1.0 5. E2000 IEC 61754-15(1999-09) Ed. 1.0 The ferrule end face geometry complies with Telcordia GR-326 specifications. The ferrule specifications: PARAMETER Ferrule type Nominal ferrule diameter(fc, SC and E2000) Nominal ferrule diameter (LC) Fiber concentricity SPECIFICATION Fully zirconia-ceramic 2.5mm±0.5μ m 1.25mm±0.5μ m 1μ m The ferrule for patch cord, pigtails are made of fully zirconia ceramic material. Dust caps are preinstalled onto the connector ends to prevent contamination. It is preferable if the dust cap is an integral part of the fiber cord.

The external parts for FC types shall be made of nickel-plated brass. For SC, LC and E2000 types, it shall be plastic body bulkhead types. Mechanical and Environment Performance for Patch Cords and Pigtails Test Type Test Condition Test Method Requirement Appearance Exam the producdt with naked eye Tensile Strength Strength of coupling mechanism Torsion Strippability Patch cord max. Tensile strength: 70N Pigtail max. Tensile strength: 5N Rate: 0N Cin 15s Point of application: 500mm from plug Duration: 60s Patch cord max. Tensile strength: 40N Pigtail max. Tensile strength: 5N Rate: 0N - in 15s Point of application: 500mm from plug Duration: 60s Max load patch cord: 15N Max load pigtail: 2N Cable clamp distance: 200mm for the tip Torsion: +180 / -180 Cycles: 25 Strip the outer jacket out of the patch cord in one action Strip tight buffer tube out of f iber in one action Use commercial available tools IEC 61300-2-4 IEC 61300-2-6 IEC 61300-2-5 1.No deformation, crack, scratch, flaw, stain, looseness and burr. 2. Change of 1)Insersion loss is less than 0.2dB 2)Return loss is less than 2dB 3)Appearance 1.Minimum length outer jacket shall be stripped: 1m 2. Minimum length of tight buffer tube shall be stripped: 25mm

TECHNICAL DATA OF PATCH CORDS FC Patch Cord (Single Mode) Item Technical Data PC UPC APC Insert Loss 0.3dB 0.2dB 0.2dB Return Loss 45dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times Working Humidity Up to 95% Up to 95% Up to 95% Temperature Range -40 ~+80-40 ~+80-40 ~+80 LC Patch Cord(Single Mode) Item Technical Data PC SPC UPC APC Insert Loss 0.3dB 0.3dB 0.2dB 0.2dB Return Loss 45dB 50dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times 1000 times

Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Temperature Range -40 ~+80-40 ~+80-40 ~+80-40 ~+80 SC Patch Cord(Single Mode) Item Technical Data PC SPC UPC APC Insert Loss 0.3dB 0.3dB 0.2dB 0.2dB Return Loss 45dB 50dB 55dB 65dB Exchange Ability <0.2dB <0.2dB <0.2dB <0.2dB Repeatability <0.1dB <0.1dB <0.1dB <0.1dB Mating Durability 1000 times 1000 times 1000 times 1000 times Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Temperature Range -40 ~+80-40 ~+80-40 ~+80-40 ~+80 E-2000 Patch Cord(Single Mode) Item Technical Data E2000/PC E2000/UPC E2000/APC Insert Loss 0.3dB 0.2dB 0.2dB Return Loss 40dB 55dB 65dB Repeatability <0.1dB <0.1dB <0.1dB Exchange Ability <0.2dB <0.2dB <0.2dB Fiber Type 9/125μm Cable Diameter φ0.9mm, φ2.0mm, φ3.0

Working Humidity Up to 95% Up to 95% Up to 95% Working Temperature -20 ~+80-20 ~+80-20 ~+80 MTRJ Patch Cord (Single Mode and Multi Mode) Item Single Mode Multi Mode PC UPC PC UPC Insert Loss 0.4dB 0.4dB 0.5dB 0.5dB Return Loss 40dB 45dB 25dB 45dB Repeatability <0.2dB <0.2dB <0.2dB <0.2dB Exchange Ability <0.1dB <0.1dB <0.1dB <0.1dB Working Humidity Up to 95% Up to 95% Up to 95% Up to 95% Storage Temperature -40 ~+80-40 ~+80-40 ~+80-40 ~+80 Operating Temperature -40 ~+80-40 ~+80-40 ~+80-40 ~+80

Production Line for Patch Cord Monthly Product Capacity: 300000 pieces of fiber optic patch cords Annual Product Capacity:3600000 pieces of fiber optic patch cords MAIN MANUFACTURING EQUIPMENT LIST Serial No. DESCRIPTION TYPE QTY (SET) 1 Curing Table 24 F 30 2 Digital Display Thermometer XMT 30 3 Grinding Machine MCD-24 15 4 Grinding Machine SFP550 10 5 Air Press V-0.6/8 6 6 Supersonic Washing Machine BG06C 5 7 Auto Fiber Cable Cutting Machine XINZE-X25 6 MAIN TEST FACILITIES LIST SERIAL NO. DESCRIPTION TYPE QTY(SET) 1 JDS Reflection Coefficient Meter RX3000 10 2 Electronic Microscope 400 M 10 3 Temperature Test Chamber WD405 5 4 Oven RLH 10 5 Mechanical Tensile Testing Machine LJ-5000 2 6 Bending/Rotation Tester JZT/Z-1 2

CERTIFICATE FOR PRODUCT CERTIFICATION

Certificate for Product Certification Certification No: 030104690196R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product FC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T 1272.4-2007 Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing www.tlc.org.cn.

CANB 030-P

Certificate for Product Certification Certification No: 030104690199R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product SC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T 1272.3-2005 Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing www.tlc.org.cn.

CANB 030-P

Certificate for Product Certification Certification No: 030104690198R1M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product LC/PC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T 1272.1-2003 Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing www.tlc.org.cn.

CANB 030-P

Certificate for Product Certification Certification No: 030104690197R2M TLC Certificate for Products Certification This is to certify Name and Address of Certificated Enterprise Sichuan Tianyi Comheart Opto-electronics Co., Ltd Registration Address: No. 210 West Street, Jinyuan Town, Dayi County, Chengdu, Sichuan, China Production Address: No. 198 Industry Avenue, Dayi County, Chendu, Certificated Product FC/APC FIBER OPTICAL PATCH CORDS Standard of Certification YD/T 1272.4-2007 Above products conform to the requirement of telecommunication cable/optical fiber cable equipment certification standards; certification mode is type test + primary factory test + supervision after obtaining the certificate 1000 Date of Issuance: March 2, 2010 Date of Expiry: March 1,, 2013 TL Certification Center Director of Center: Song Busi * Note: Related product details about conforming to the standards are shown in attachment. The validity of this certification also depends on the annual regular supervision conclusion specified in attachment, or it can be obtained by assessing www.tlc.org.cn. CANB 030-P