User Manual / Care Instructions

Similar documents
TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

PENSOTTI TOWEL BAR WARMERS

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

MYSON. Towel Warmers. heatingthroughinnovation.

Tuzio Milano Towel Warmer

Electric & Hydronic Models Installation & Operating Instructions. mr.steam towelwarmers. Model. Serial # PUR Rev. 9.0/06

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

TUB AND SHOWER FAUCET

Hydronic Series Towel Warmers Installation & Operating Guide

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

2 DESCRIPTION OF SYSTEM COMPONENTS

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

Installation S

Oahu Showerspa Model #1035 Owner's Manual

Installation, Operation and Maintenance Manual. Broadway Collection Electric Towel Warmers Models: W216, W219, W228, W236, W248

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

Installation Guide. Product Code: MS228-PC. p: f: Page 1 of 8. ITEM: Electric Towel Warmer from Mr.

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

Installation S

B.I.C.A Built-In Coffee Appliance

propanel Series Installation Manual

TIMES SQUARE TWO-HANDLE THERMOSTAT

One Less Thing to Forget...

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS. Uptown Contempo Widespread Faucets Part # s: 8880-****, 8881-****

ECO1ZN3P, ECO2ZN4P ECO

TUB AND SHOWER FAUCET

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

General System Layout Sketch

Installation Instructions / Warranty. Metris 31060XX XX XX1

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

Installation S

Installation & Operation Manual for WarmlyYours Towel Warmers

ACRYLIC CLAWFOOT TUB


Installation Instructions / Warranty

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

OSD10, OSD20 & OSD30 DRINK DISPENSER

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

PL-004-SS. * Proper water pressure is required for simultaneous operations

IMPORTANT SAFETY INSTRUCTIONS:

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Installation, Operation, and Maintenance Manual

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

User Manual. Product Code: TJHC6. T: F: Page 1 of 9 PRODUCT #: TJHC6

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Installation & Operation Manual for WarmlyYours Towel Warmers

Installation Instructions PP-AS20 Anti-Scale System

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

Model. Serial No. Installation, Operation and Maintenance Manual. Lexington Collection ELECTRIC TOWEL WARMERS. mr.steam. Feel Good Inc.

Installation Guide Europa

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Installation Instructions / Warranty

WHISPA III 5000, 7000 & Installation, Operating, Maintenance and After Sales Manual. Tested to UL & CSA Standards. Part Number: Issue 1

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

ispring Whole House Water Filter Systems USER S MANUAL

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Installation S

TECHNICAL INSTRUCTIONS

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Installation Instructions / Warranty

Crown Boiler Company

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

Single Lever Pull Out Kitchen Faucet

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Waimea ShowerSpa MODEL #1034

U.1347LS. Perrin & Rowe Kitchen Filtered Hot Water Dispensers 2 3/8" 5 1/2" 10" 6 1/2" 3 7/8" Ø1 7/8" 1 3/4" MAX Ø1 1/4" HOLE

Owner s Manual Therma-Stor II Heat Recovery System

SANTA CRUZ. Santa Cruz ShowerSpa Model #1033 Owner's Manual

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Laundry Kit With flexi-neck faucet and storage cabinet

Water Boilers ME10EN, ME15EN. Table of Contents

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

INSTALLATION INSTRUCTIONS M SHOWER SLIDING RAIL

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

Pop-up Clicker Drain Installation and User Guide

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Transcription:

Product Code: MYWEO140 User Manual / Care Instructions PRODUCT #: MYWEO140 ITEM: Classic Wall Mount from Myson BRAND: Myson SOURCE FOR PURCHASE: SpaEquip, Inc. 211 Wappo Ave., Calistoga, CA 94515 p: 707.737.1100 f: 707.737.1150 www.spaequip.com LIST PRICE (USD): FEATURES: High quality chrome complete with all hardware (Wire kit). 23"(586mm) L x 4.5"(114.3mm) W x 33.5"(851) H SPECIFICATIONS: Dimensions: Electrical: Suggested Outlet: Plumbing: Notes: Warranty: Certifications: Country of Origin: Installed By: 23"(586mm) L x 4.5"(114.3mm) W x 33.5"(851) H 120V AC, 200 Watts (220V if option Selected) Hard wired, Built-in GFCI None Mount with top 5.5' AFF if used to warm robes 1 Year UL, cul United States Client's Contractor www.spaequip.net p: 707.737.1100 Page 1 of 6

HYDRONIC TOWEL WARMERS Installation and Operating Instructions For Floor or Wall-Mounted MYSON s 948 Hercules Drive, Colchester, VT 05446 Phone: 800-698-9690 Fax: 802-654-7022 www.mysoninc.com CAUTION: 1. Read this entire instruction manual thoroughly before beginning installation and save these instructions. 2. Follow instructions accurately to make certain the Towel Warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 3. Do not use an abrasive cleaner on the. A mild detergent will clean and restore most units to their original beauty. 4. TO ENSURE FULL EFFICIENCY OF YOUR TOWEL WARMER, PLEASE FOLLOW ALL THE INSTRUCTIONS CAREFULLY, OBSERVING THE CAUTION NOTATIONS FOR EACH STEP. 5. Inlet water temperature should be between 120 F and 150 F. DO NOT exceed this limit. A burn hazard may result. Valves Air Vent Key Sleeve Kit Cross Handle Valve fig 1: Installation Parts Fixing Screws Adjustable Wall Stays (where applicable) GENERAL: The is designed to provide an all year-round service for airing towels and articles of clothing. Most s provide enough heat to warm towels and provide additional heat to the room. Larger units may be sufficient to serve as the sole heat source for a small bathroom. STEP 1: PRE-INSTALLATION A. Select Installation Site: Make certain there is ample clearance on both sides and back of the. Note: This unit is supplied with the proper hardware for installation. Be sure wall construction is appropriate for hanging (see Step 3A). B. Before beginning the installation of any Towel Warmer, please note the following: 1. Maximum operating temperature should be no higher than 150 F or 66 C. Any working water temperature higher than 150 F could create a potential burn hazard. 2. s take 20 minutes to 30 minutes to heat towels properly. For this reason, we do not recommend piping s through shower valves. 3. s can be safely operated continually year-round without turning them off. 4. s may be controlled by a timer or a thermostat that controls the system pump. C. Refer to rough-in information on back page. STEP 2: INSPECT MYSON TOWEL WARMER A. Unpack the MYSON carefully to avoid any damage or loss of any part. When opening the box and unwrapping the, be sure that parts are not accidentally discarded (see illustration, fig 1). B. MYSON s are shipped in specially designed shipping cartons. The entire surface of the is hand-wrapped to protect the finish. Check the wrapping for any sign of damage. STEP 3: INSTALLATION Carefully remove the protective wrapping and move the Towel Warmer into position. A. Mounting: 1. The MYSON has been designed with integral fixing flanges. These will facilitate a permanent and secure mounting of the to the wall or floor using the screws provided. In addition, some models come with adjustable wall stays for extra security. B. Valve Installation: 1. The valves are composed of a main body, a union connection, and a copper compression ring and nut located at the bottom of the valve (have the sleeve kit available at this time). 2. The sleeve kit consists of a small escutcheon plate and matching 3" piece of tubing used to cover the water pipe connections. 3. After having stubbed the copper tubing, place the sleeve and escutcheon plate over exposed copper tubing. 4. Place compression nut and ring onto the copper tube (see fig 2). 5. Next, remove the valves from the and check to be sure that the valves are completely OPEN. IMPORTANT: There are two valves which come with s. One valve is always permanently open, but the other valve can be opened or closed. These valves seal only in the fully OPEN or fully CLOSED position. Using the valve to throttle the water flow will result in a leak at the valve stem. 6. Remove union and nipple from the valve. Apply either Teflon tape or pipe joint compound on the threads of the nipple. Hand tighten nipple to. With an Allen wrench inserted into the nipple, hand tighten to secure appropriate fit (DO NOT USE A PIPE WRENCH OR PLIERS, and DO NOT OVER TIGHTEN. OVER TIGHTENING WILL CAUSE THE UNIT TO LEAK). Read completely before beginning

Note: One to three threads may still be visible when tightened. 7. Set valve into position and seat copper tubing into the base of the valve. Seat the union nipple into the valve and loosely tighten the union nut. Hand tighten the compression nut. Union Nut Nipple Top of Valve (fixed) Valve Body CAUTION: DO NOT TURN THE VALVE BODY, TURN THE NUT ONLY. TURNING THE VALVE BODY WILL SPLIT THE COMPRESSION RING, MAKING A GOOD SEAL UNLIKELY. DO NOT OVER TIGHTEN! 8. Turn the compression nut 1/4 turn more to securely seal. Tighten union connection to valve. Repeat for second valve. Water is ready to be circulated through your MYSON Towel Warmer at this time. 9. Connect to hot water system using one of the options shown below or on the following page. When all connections are complete, add water and vent unit using the bleed valve located on the top rail at the back or side of the unit, depending on the style of the unit. Note: The key for the bleed valve is provided with the unit. fig 2 Pipe Compression Ring Compression Nut Sleeve Escutcheon Plate STEP 4: OPERATION & MAINTENANCE Your MYSON can be left on continuously without detrimental effect either to the or to the articles on it. CLEANING: The finish of your MYSON can be protected and maintained by an occasional wiping with a damp cloth and lightly polished thereafter with a soft dry cloth. Under no circumstances should abrasive cleaning powders or metal polish be used on any part of a chrome or gold plated. Two Gallon Electric Water Heater Connection GENERAL: MYSON s require a hot water supply at a temperature between 120 F and 150 F. This connection scheme uses a stand alone hot water heater as the heat source. A small two gallon heater is all that is required. 1. Connect the to the heater as shown in fig 3. The circulator pump should be installed on the hot water discharge of the mini heater. The return is connected to a return port on the mini heater or it may be joined with the cold water supply. A shutoff valve should be installed on the cold water supply. Install a pressure relief valve on the mini heater. 2. Open the air vent using the vent key provided, and fill the and mini heater with water by opening the water supply valve. Close the air vent and supply valve and allow the water to circulate. Venting may be required several times after heating in order to remove all of the entrained air. 3. Control the circulator pump using a thermostat, timer or manual switch. MYSON INSTALLATION OPTIONS Hot Water Boiler Connection 1. Connect the on a separate zone with the circulator pump on the feed line to the as shown in fig 4. 2. Use a 3-way mixing valve to reduce the water temperature going to the, not to exceed 150 F. 3. Fill and vent the. Open the air vent using the vent key provided. Close the air vent and allow the water to circulate. Venting may be required several times after heating in order to remove all of the entrained air. 4. Control circulator pump using a thermostat, timer or manual switch. Circulator Pump Thermostat, Timer or Manual Switch Pump Controller 3-way Mixing Valve Hydronic Hot Water Heater Cold Water Supply Two-Gallon Water Heater Circulator Pump Thermostat, Timer or Manual Switch Pump Controller 110 V/AC Outlet fig 4: Hot Water Boiler Connection fig 3: Two Gallon Electric Water Heater Connection

MYSON INSTALLATION OPTIONS...continued Steam Boiler (using condensate) Connection 1. Install a 3/4" bypass loop with full port ball valve from the condensate return to the hot water draw off. DO NOT connect to a steam line. MYSON s require water at a temperature not to exceed 150 F. 2. Connect on a separate zone with the circulator pump on the feed line to the as shown in fig 5. 3. Install a 3-way mixing valve connecting the return and the feed from the boiler as shown. 4. Fill and vent the. Open the air vent using the vent key provided. Close the air vent and allow the water to circulate. Venting may be required several times after heating in order to remove all of the entrained air. 5. Adjust full port ball valve on the boiler bypass line to divert a portion of the condensate return through the boiler to add heat to the zone. 6. Balance system to attain a 150 F water temperature going to the. Domestic Hot Water Heater Connection 1. MYSON s are brazed with lead free materials, and are compatible with open loop domestic hot water systems. See fig 6. Hot water temperature must be set to a maximum of 150 F. 2. Install a circulator pump on the feed line to the. Connect return with the cold water supply to the hot water heater. Provide a check valve on the cold supply as required by local codes. 3. Fill and vent the. Open the air vent using the vent key provided. Close the air vent and allow the water to circulate. Venting may be required several times after heating in order to remove all of the entrained air. 4. Control circulator pump using a thermostat, timer or a manual switch. Cold Water Supply Pump Controller Circulator Pump Thermostat, Timer or Manual Switch Circulator Pump 3 4 Bypass Line Water Level Steam Boiler Full-port Ball Valve fig 5: Steam Boiler (using condensate) Connection Thermostat, Timer or Manual Switch Pump Controller 3-way Mixing Valve Water Heater fig 6: Domestic Hot Water Heater Connection Radiant Heat Systems Connection 1. For radiant heat systems which have available water temperatures greater than 150 F, follow the instructions for connection to hydronic (hot water) heating systems in fig 4. 2. For radiant heat systems operating at about 120 F, follow the instructions for connection to domestic hot water heaters in fig 6. 3. For low temperature radiant heat systems operating at less than 120 F, a separate heater is required. Follow the instructions for installation using an electric water heater in fig 3. AFTER SALES SERVICE: 1-800-698-9690 (8-5 EST) We guarantee your for five years from date of purchase, and we undertake to exchange or repair free of charge within this period any part found to be defective. Refer to the enclosed Warranty Registration for more information. BE SURE TO SEND IN YOUR REGISTRATION CARD TO REGISTER YOUR MYSON TOWEL WARMER. Fill in the following information and have it ready when calling for additional information about your MYSON. Model # Date purchased Date installed Dealer/store name where purchased

MYSON PREMIER HYDRONIC TOWEL WARMERS B24 B29 B31 S6 CYG 14 B26 B30 B34 Model BTU/hr at Overall Overall Width Width C/C Center to Floor to Overall Tube Shipping 100 F Temp Height Including Vertical Center Center Projection Diameter Weight Difference Flanges Tubes Connection Connection LBS B24/1 634 37 1 2 27 24 18 4 1 4 5 1 8 1 68 lbs. B24/2 710 37 1 2 33 30 24 4 1 4 5 1 8 1 68 lbs. B24/3 790 37 1 2 39 36 30 4 1 4 5 1 8 1 68 lbs. B24/4 750 37 5 8 27 1 4 24 18 4 1 4 5 3 8 1 1 4 68 lbs. B24/5 850 37 5 8 33 1 4 30 24 4 1 4 5 3 8 1 1 4 68 lbs. B24/6 940 37 5 8 39 1 4 36 30 4 1 4 5 3 8 1 1 4 68 lbs. B26/1 1350 36 7 8 27 1 4 24 18 4 1 4 Depends 1 1 4 49 lbs. B26/2 1440 36 7 8 33 1 4 30 24 4 1 4 on 1 1 4 49 lbs. B26/3 1530 36 7 8 39 1 4 36 30 4 1 Wall 4 1 1 4 49 lbs. B26/4 1620 36 7 8 45 1 4 42 36 4 1 Stays 4 1 1 4 49 lbs. B29 1650 41 27 1 4 24 24 N/A 4 7 8 1 1 4 78 lbs. B30 1500 39 27 1 4 24 18 4 1 4 8 3 4 1 1 4 81 lbs. B31/1 1429 27 1 4 27 1 4 24 18 N/A 6 7 8 1 1 4 49 lbs. B31/2 1547 33 1 4 33 1 4 30 24 N/A 6 7 8 1 1 4 57 lbs. B31/3 1702 33 1 4 39 1 4 36 30 N/A 6 7 8 1 1 4 57 lbs. B31/4 1802 33 1 4 45 1 4 42 36 N/A 6 7 8 1 1 4 57 lbs. B34/1 594 27 27 24 18 N/A 6 5 8 1 51 lbs. B34/2 699 27 33 30 24 N/A 6 5 8 1 51 lbs. B34/3 747 27 39 36 30 N/A 6 5 8 1 51 lbs. B34/4 795 33 39 36 30 N/A 6 5 8 1 51 lbs. B34/5 713 27 1 4 27 1 4 24 18 N/A 6 7 8 1 1 4 51 lbs. B34/6 805 27 1 4 33 1 4 30 24 N/A 6 7 8 1 1 4 51 lbs. B34/7 894 27 1 4 39 1 4 36 30 N/A 6 7 8 1 1 4 68 lbs. B34/8 952 33 1 4 39 1 4 36 30 N/A 6 7 8 1 1 4 68 lbs. MYSON CLASSIC HYDRONIC TOWEL WARMERS S11 S14 Model BTU/hr at Overall Overall Width Width C/C Center to Floor to Overall Tube Shipping 100 F Temp Height Including Vertical Center Center Projection Diameter Weight Difference Flanges Tubes Connection Connection LBS S6/1 1350 36 5 8 27 1 4 24 17 1 2 4 1 4 Depends 1 1 4 50 lbs. S6/2 1440 36 5 8 33 1 4 30 23 1 2 4 1 4 on 1 1 4 59 lbs. S6/3 1530 36 5 8 39 1 4 36 29 1 2 4 1 Wall 4 1 1 4 70 lbs. S6/4 1620 36 5 8 45 1 4 42 35 1 2 4 1 Stays 4 1 1 4 79 lbs. S11/1 1429 27 1 4 27 1 4 24 17 1 2 N/A 6 1 2 1 1 4 50 lbs. S11/2 1547 33 1 4 33 1 4 30 23 1 2 N/A 6 1 2 1 1 4 59 lbs. S11/3 1702 33 1 4 39 1 4 36 29 1 2 N/A 6 1 2 1 1 4 79 lbs. S11/4 1802 33 1 4 45 1 4 42 35 1 2 N/A 6 1 2 1 1 4 79 lbs. S14/1 594 27 27 24 17 3 4 N/A 6 1 2 1 50 lbs. S14/2 669 27 33 30 23 3 4 N/A 6 1 2 1 50 lbs. S14/3 747 27 39 36 29 3 4 N/A 6 1 2 1 70 lbs. S14/4 795 33 39 36 29 3 4 N/A 6 1 2 1 70 lbs. CYG14/1 369 27 27 24 17 3 4 N/A 5 1 2 1 50 lbs. CYG14/2 433 27 33 30 23 3 4 N/A 5 1 2 1 50 lbs. CYG14/3 495 27 39 36 29 3 4 N/A 5 1 2 1 70 lbs. CYG14/4 536 33 39 36 29 3 4 N/A 5 1 2 1 70 lbs. MYSON MULTIRAIL HYDRONIC TOWEL WARMERS MRR Additional Towel Rail increases projections by 6 inches Model BTU/hr at Optional Overall Overall Width Width C/C Center to Floor to Overall Tube Shipping 100 F Temp Add l Height Including Vertical Center Center Projection Diameter Weight Difference Towel Rail Flanges Tubes Connection Connection LBS MRR1 1605 MRAC1 29 7 8 19 11 16 18 1 2 18 1 2 N/A 3 7 8 17 lbs. MRR2 1904 MRAC2 29 7 8 23 5 8 22 1 2 22 1 2 N/A 3 7 8 20 lbs. MRR3 2351 MRAC3 29 7 8 29 1 2 28 1 4 28 1 4 N/A 3 7 8 24 lbs. MRR4 2341 MRAC1 46 7 8 19 11 16 18 1 2 18 1 2 N/A 3 7 8 35 lbs. MRR5 2797 MRAC2 46 7 8 23 5 8 22 1 2 22 1 2 N/A 3 7 8 50 lbs. MRR6 3483 MRAC3 46 7 8 29 1 2 28 1 4 28 1 4 N/A 3 7 8 61 lbs. MRR7 3524 MRAC1 70 7 8 19 11 16 18 1 2 18 1 2 N/A 3 7 8 150* lbs. 1 1 4 Vertical Tubes 1 Round Cross Tubes MRR8 4204 MRAC2 70 7 8 23 5 8 22 1 2 22 1 2 N/A 3 7 8 150* lbs. MRR9 5222 MRAC3 70 7 8 29 1 2 28 1 4 28 1 4 N/A 3 7 8 150* lbs. *Must ship LTL truck All dimensions are in inches.

MASTER SUITE HYDRONIC TOWEL WARMERS Model BTU/hr at Overall Overall Width Width C/C Center to Floor to Overall Tube Shipping 100 F Temp Height Including Vertical Center Center Projection Diameter Weight Difference Flanges Tubes Connection Connection LBS B25/1 920 61 5 8 21 1 4 18 12 4 1 4 5 3 8 1 1 4 150 lbs.* B25/2 1060 61 5 8 27 1 4 24 18 4 1 4 5 3 8 1 1 4 150 lbs.* B25/3 1200 61 5 8 33 1 4 30 24 4 1 4 5 3 8 1 1 4 150 lbs.* B25 B35/1 825 51 1 4 21 1 4 18 18 N/A 6 7 8 1 1 4 150 lbs.* B35/2 970 51 1 4 27 1 4 24 24 N/A 6 7 8 1 1 4 150 lbs.* B35 B36 VR1 B35/3 1100 51 1 4 33 1 4 30 30 N/A 6 7 8 1 1 4 150 lbs.* B36/1 1680 51 1 4 21 1 4 18 18 N/A 6 7 8 1 1 4 150 lbs.* B36/2 2130 51 1 4 27 1 4 24 24 N/A 6 7 8 1 1 4 150 lbs.* B47/1 2380 68 3 8 27 1 4 24 18 4 1 4 5 3 8 1 1 4 150 lbs.* B47/2 2550 68 3 8 33 1 4 30 24 4 1 4 5 3 8 1 1 4 150 lbs.* B49 2500 73 1 2 27 1 4 24 18 4 1 4 5 3 8 1 1 4 150 lbs.* VR1 3150 37 1 2 26 3 4 23 1 2 17 1 8 4 1 4 8 1 8 1 1 4 60 lbs. *Must ship LTL truck B49 B47 ALOHA CURVED MULTIRAIL HYDRONIC TOWEL WARMERS Rough-In Details for ALL Units: All Premier, Classic and Master Suite Towel Warmers: rough-in with 3/4" copper. Multirail (MRR) and Aloha (CMR) Towel Warmers: rough-in with 1/2" copper. Rough-In Details for all WALL Units: All s (except MRR, CMR and B29): rough-in on centerline of the bottom rail. Master Suites and B29: rough-in is 3" below center of bottom rail on centerline of vertical rails. MRR and CMR: rough-in is 2" below bottom of unit on centerline of vertical rails. CMR Type Btu/hr. Overall Overall Width Width C/C Center Floor Overall Tube Approx. 100ºF Temp. Height Including Vertical to Center to Center Projection Diameter Shipping Difference Flanges Tubes Connection Connection Weight CMR1 1215 28 1 2 19 1 4 17 1 2 17 5 8 N/A 5 1 4 39 lbs. CMR2 1438 28 1 2 23 1 4 21 3 8 21 1 2 N/A 5 1 4 45 lbs. CMR3 1774 28 1 2 29 1 8 27 1 4 27 3 8 N/A 5 1 4 56 lbs. CMR4 2046 47 19 1 4 17 1 2 17 5 8 N/A 5 1 4 59 lbs. CMR5 2423 47 23 1 4 21 3 8 21 1 2 N/A 5 1 4 68 lbs. CMR6 2989 47 29 1 8 27 1 4 27 3 8 N/A 5 1 4 82 lbs. CMR7 3237 73 19 1 4 17 1 2 17 5 8 N/A 5 1 4 150 lbs.* CMR8 3838 73 23 1 4 21 3 8 21 1 2 N/A 5 1 4 150 lbs.* CMR9 4736 73 29 1 8 27 1 4 27 3 8 N/A 5 1 4 150 lbs.* *Must ship LTL truck Frame D Shaped 1 5 8 X 1 1 8 Crosstubes Oval 1 1 8 X 7 8 All dimensions are in inches. 5 YEAR WARRANTY MYSON warrants your for a Full Five Years against the following manufacturing defects: 1. MYSON warrants the plated or painted finish of your from manufacturing defects for five full years from the date of installation. This means your finish will not crack, split, peel or flake from the surface of the rails. 2. MYSON warrants the brazed connections and the tubing of your to be free from leaks for five full years from the date of installation. 3. MYSON warrants your electric element to heat properly for five full years from date of installation. We are extremely proud of the quality of our s and each piece has been inspected several times prior to its shipment to you to make sure that you receive the very best. There are a few things within reason that are not within the control of our manufacturing processes and are not considered manufacturing defects: 1. Every square inch of your is hand-wrapped in special soft crepe-type wrapping paper to protect the finish. Then, MYSON carefully packages every to guarantee its safe arrival to your home. We do not warrant your for handling damage once it is removed from our packaging. 2. MYSON does not warrant the finish on your if you use abrasive cleaners or chlorine-based cleaners. Use of these cleaners will damage the finish beyond repair. 3. MYSON does not warrant your from damage due to freezing temperatures within your home. 4. MYSON does not warrant your from damage due to improper installation such as over tightening water connections on hydronic s or the improper wiring of electric s. We wish you years of satisfaction and comfort from your MYSON Towel Warmer. MYSON will repair or replace at our discretion any product which fails under these categories. We do not accept liability for any labor cost involved. Should a problem occur, please do not hesitate to contact us. 220289/FAX