Operator: Save these instructions for future use!

Similar documents
21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50A Integrated Furnace Control

Operator: Save these instructions for future use!

50A Integrated Furnace Control

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

WARNING CAUTION 50T INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS. Integrated Furnace Control

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

40 Residential Gas Furnace Operation

Hot Surface Ignition (HSI) System Booklet

BGH Series Hot Surface Ignition Control

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

24 VAC Direct Spark Gas Ignition

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Emerson Blue Easy Set 1H/1C

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Model 60200FR Gas Primary Control Data Sheet

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Interrupted Ignition Series Oil Primary Control

Installation and Operating Instructions

SV9520H SmartValve System Control Line Voltage Polarity Sense Models

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Operator: Save these instructions for future use!

Model Universal Oil Primary Control

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Operator: Save these instructions for future use!

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

24 VAC Intermittent Pilot Gas Ignition Control

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Technical Manual MAY 2008 Edition

59MN7A Series 100 TROUBLESHOOTING GUIDE

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

SV9540; SV9640 SmartValve System Controls

Technical

COMMERCIAL GAS WATER HEATERS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

*9MAC TROUBLESHOOTING GUIDE

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

SV9560/SV9570 SmartValve Water Heater Controls

POWER VENTER. Model: PVE Series

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

Bosch 80% AFUE Gas Furnace BGS80 Model

Operator: SaVe these instructions forfuture use

USER S INFORMATION MANUAL

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

New Power Vented Rheem FVIR Tanks

EG & PEG Series 5 EGH Series 5

G32V. Service Literature G32V SERIES UNITS

CSD-1 COMMERCIAL BOILER CONTROLS

Heat Pump Defrost Board Replacement Kit

I/O ZONE 560/583 AND OPERATION MANUAL

1F98EZ-1421, Easy Install

USER S INFORMATION MANUAL (2,4)SG13B

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Technical Information

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

A.O. Smith Water Products Company

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

2017 OUTDOOR CONTROL SYSTEM WEATHER BEATER ELECTRONIC CONTROL SYSTEM

MERIT SERIES Downflow

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

Transcription:

50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation. These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. Installation should be done by a qualified heating and air conditioning contractor or licensed electrician. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction. Following installation or replacement, follow manufacturer s recommended installation/service instructions to ensure proper operation. CAUTION Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat. CONTENTS Description... 1 Precautions... 1 Specifications... 2 Installation... 3 Mounting & Wiring Operation... 6 System Lockout and Diagnostic Features... 7 Troubleshooting... 8 INSTALLATION INSTRUCTIONS 50A66-743 Cross Reference Information Lennox White-Rodgers 100925-01 23W51 69M0801 50A66-122 100925-02 23W5101 69M15 50A66-123 100925-03 30W25 69M1501 50A66-743 17W92 30W2501 17W9201 69M08 PRECAUTIONS WARNING Failure to comply with the following warnings could result in personal injury or property damage. FIRE HAZARD Do not exceed the specified voltage. Replace existing control with exact model and dash number. Protect the control from direct contact with water (dripping, spraying, rain, etc.). If the control has been in direct contact with water, replace the control. Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Route and secure wiring away from flame. SHOCK HAZARD Disconnect electric power before servicing. Ensure proper earth grounding of appliance. Ensure proper connection of line neutral and line hot wires. EXPLOSION HAZARD Shut off main gas to appliance until installation is complete. white-rodgers.com emersonclimate.com PART NO. 37-7473B Replaces 37-7473A 1515

SPECIFICATIONS ELECTRICAL RATINGS [@ 77 F (25 C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Current: 2.0 amp @ 80 VAC Inducer Relay: 2.2 FLA 3.5 LRA @ 120 VAC Circulator Relay: 14.5 FLA 25.0 LRA @ 120 VAC Flame Current Requirements: Minimum current to insure flame detection: 0.25 µa DC* Maximum current for non-detection: 0.1 µa DC* Maximum allowable leakage resistance: 100 M ohms *Measured with a DC microammeter in the flame probe lead OPERATING TEMPERATURE RANGE: -40 to 175 F (-40 to 80 C) HUMIDITY RANGE: 5% to 93% relative humidity (non-condensing) MOUNTING: Surface mount multipoise Timing Specs: (@ 60 Hz**) Flame Establishing Time: Flame Failure Response Time: maximum 0.8 sec 2.0 sec ** At 50 Hz, all timing specifications should be increased by 20% Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixtures are all approved for use. Pre-Purge Trial for Ignition Period (TFI) TIMING SPECIFICATIONS (All times are in seconds, unless noted otherwise Event Definition 50A66-743 Ignition Activation Period (IAP) Retries Valve Sequence Period Interpurge Post-Purge The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the beginning of a furnace operating cycle prior to initiating ignition The period of time between initiation of gas flow and the action to shut off the gas flow in the event of failure to establish proof of the supervised ignition source or the supervised main burner flame. The period of time between energizing the main gas valve and deactivation of the ignition means prior to the end of TFI The additional attempts within the same thermostat cycle for ignition when the supervised main burner flame is not proven within the first trial for ignition period. Valve sequence period equals 4 seconds trial for ignition period x (1 initial try + 2 retries) + 12 seconds. The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period. The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the end of a furnace burner operating cycle. Post-purge begins at the loss of flame sense. 15 4 4 4 times Lockout Time ANSI standard rated module timing. 250 Heat Delay-To-Fan-On Heat Delay-To-Fan-Off* Cool Delay-To-Fan-On Cool Delay-To-Fan-Off* Ignitor Warm-up Auto Reset Humidifier Electronic Air Cleaner The period of time between proof of the supervised main burner flame and the activation of the blower motor at Heat speed. The period of time between the loss of a call for heat and the deactivation of the blower motor at Heat speed. The period of time after a thermostat demand for cool before energizing the circulator blower motor at Cool speed. The period of time between the loss of a call for cool and the deactivation of the blower motor at Cool speed. The length of time allowed for the igniter to heat up prior to the initiation of gas flow. After one (1) hour of internal or external lockout, the control will automatically reset itself and go into an auto restart purge for 60 seconds. 20 15 5 45 60/90/120/180 2 2/45 20 60 minutes *This time will vary depending on option switch position. The control is factory set at 90 seconds HEAT delay-to-fan-off and 45 seconds COOL delay-to-fan-off. See OPERATION section for further information. Yes Yes 2

WARNING FIRE HAZARD Do not exceed the specified voltage. Replace existing control with exact model and dash number. Protect the control from direct contact with water (dripping, spraying, rain, etc.). Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Route and secure wiring away from flame. SHOCK HAZARD Disconnect electric power before servicing. Ensure proper earth grounding of appliance. Ensure proper connection of line neutral and line hot wires. EXPLOSION HAZARD Shut off main gas to appliance until installation is complete. INSTALLATION Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat. MOUNTING AND WIRING All wiring should be installed according to local and national electrical codes and ordinances. The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175 F. The control is approved for minimum ambient temperatures of -40 F. Any orientation is acceptable. Refer to the wiring diagram and wiring table when connecting the 50A66 control to other components of the system. UL approved, 105 C rated 18 gauge, stranded, 2 /64 thick insulation wire is recommended for all low voltage safety circuit connections. Refer to 50A66 specification sheet for recommended terminals to mate with those on the control. UL approved 105 C rated 16 gauge min., stranded, 4 /64 thick insulation wire is recommended for all line voltage connections. Refer to 50A66 specification sheet for recommended terminals to mate with those on the control. After installation or replacement, follow appliance manufacturer s recommended installation or service instructions to ensure proper operation. 3

WIRING HOT (LINE) TYPICAL SYSTEM WIRING DIAGRAM 120 VAC NEUTRAL (LINE) 24 VAC CLASS II TRANSFORMER TH 24 VAC 50A66 TR FAN COOL HEAT PARK PARK LINE XFMR EAC HUM PARK UCER CIRCULATOR BLOWER HUMIDIFIER N N ITOR ELECTRONIC AIR CLEANER 120 VOLT NEUTRAL Y Y W G W G COMPRESSOR CONTACTOR 24 V HUMIDIFIER R C R THERMOSTAT LEGEND FLAME SENSOR PROBE Low Voltage (24 VAC) Line Voltage (120 VAC) N. C. = Normally closed switch N. O. = Normally open switch 24 V HUM (E2) FP (E33) PSI PSO HLI HLO RO OUT GND RO IN LO HI COM TR TH [12-Pin Connector] N N 4-Pin Connector 1 HLO PSO HLI PSI 2 3 HIGH LIMIT (N. C.) LO TH ROLLOUT (N. C.) RO OUT TR GND COM RO OUT 12-Pin Connector PRESSURE SWITCH (N. O.) AUX. HIGH LIMIT (N. C.) 2 STAGE GAS VALVE 4

WIRING TYPICAL SYSTEM WIRING TABLE 50A66 TERMINAL W G R Y C HLO (Pin 1) Not Used (Pin 2) TH (Pin 3) Not Used (Pin 4) RO1 (Pin 5) TR (Pin 6) HLI (Pin 7) GND (Pin 8) COM (Pin 9) PSI (Pin 10) RO2 (Pin 11) (Pin 12) N N TERMINAL TYPE Terminal block with captive screws HLO PSO HLI PSI LO TH RO OUT TR GND COM N RO OUT N SYSTEM COMPONENT CONNECTION low voltage thermostat W terminal (or equivalent) low voltage thermostat G terminal (or equivalent) low voltage thermostat R terminal (or equivalent) low voltage thermostat Y terminal (or equivalent) (2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil) 24 VAC COMMON side of compressor contactor coil high limit OUTPUT 24 VAC transformer (low voltage HIGH side) rollout switch OUTPUT 24 VAC transformer (low voltage COMMON side) high limit INPUT MUST BE RELIABLY GROUNDED TO CHASSIS gas valve COMMON pressure switch INPUT rollout switch INPUT gas valve inducer HOT side ignitor HOT side inducer NEUTRAL side ignitor NEUTRAL side COOL HEAT PARK (3 terminals) LINE XFMR EAC (optional) HUM (optional) 120 VOLT NEUTRAL (5 terminals) FP (E33) FAN 24 V HUM (E2) 1 / 4 spade terminal 1 / 4 spade terminal 1 / 4 spade terminal 3 / 16 spade terminal 1 / 4 spade terminal 1 / 4 receptacle * maximum recommended flame probe wire length is 36 inches. circulator blower COOL SPEED terminal circulator blower HEAT SPEED terminal unused circulator blower terminals input voltage (120 VAC) HOT side 24 VAC transformer line voltage HOT side electronic air cleaner HOT side humidifier HOT side Terminals for 120 Volt NEUTRAL for line, transformer, circulator, electronic air cleaner and humidifier flame sensor probe* Circulator blower fan speed terminal 24 VAC humidifier 5

OPERATION OPTION SWITCHES The option switches on the 50A66-743 control are used to determine the length of the heat delay-to-fan-off period. The following table shows the time periods that will result from the various switch positions. OPTION SWITCH POSITIONS HEAT delayto-fan-off: 60 sec. 90 sec.* 120 sec. 180 sec. COOL delayto-fan-off: 2 sec. 45 sec.* * Factory Setting Set switch #1 #2 Off Off Off On On Off On On Set switch #3 Off On HEAT MODE In a typical system, a call for heat is initiated by closing the thermostat contacts. This starts the 50A66 control s heating sequence. The inducer blower and humidifier are energized. After a 15-second prepurge period, the 768A Silicon Nitride ignitor is powered. This controller has an adaptive algorithm that reduces the ignitor temperature to slightly greater than the minimum temperature required to ignite gas in each particular application. The control measures the line voltage and determines an initial ignitor temperature setting based on the measurement. After each successful ignition, the control lowers the ignitor temperature slightly for the next ignition attempt. The control continues to lower the ignitor temperature until ignition does not occur, and the control goes into retry mode. For the second attempt to ignite gas within the same call for heat, the control increases the ignitor temperature to the value it was on the third previous successful ignition. After ignition is successful, the control sets the ignition temperature at this value for the next 255 calls for heat, after which the control repeats the adaptive algorithm. The control is constantly making adjustments to the ignitor temperature to compensate for changes in the line voltage. The 80 VAC Silicon Nitride ignitor manufactured by White-Rodgers must be used. These ignitors are specially designed to operate with the 50A66 s adaptive ignition routine to ensure the most efficient ignitor temperature. At the end of the ignitor warm-up time, both valves in the 36E manifold gas valve are opened. Flame must be detected within 4 seconds. If flame is detected, the delay-to-fan-on period begins. After the delay-to-fan-on period ends, the circulator fan is energized at heat speed. If there is an optional electronic air cleaner on the system, the electronic air cleaner and the humidifier are energized. When the thermostat is 6 satisfied, the gas valve is de-energized. After proof of flame loss, the inducer blower remains energized to purge the system for 5 seconds and the delay-to-fan-off period begins. When the purge is complete, the inducer blower and humidifier are de-energized. After the delay-to-fan-off period ends, the circulator fan and electronic air cleaner are de-energized. If flame is not detected, both valves are de-energized, the ignitor is turned off, and the 50A66 control goes into the retry sequence. The retry sequence provides a 15-second wait following an unsuccessful ignition attempt (flame not detected). After this wait, the ignition sequence is restarted. If this ignition attempt is unsuccessful, three more retries will be made before the control goes into system lockout. If flame is detected, then lost, the 50A66 control will repeat the initial ignition sequence for a total of three recycles. After three unsuccessful recycle attempts, the control will go into system lockout. If flame is established for more than 10 seconds after ignition, the 50A66 controller will clear the ignition attempt (or retry) counter. If flame is lost after 10 seconds, it will restart the ignition sequence. This can occur a maximum of four times before system lockout. A momentary loss of gas supply, flame blowout, or a shorted or open condition in the flame probe circuit will be sensed within 2 seconds. The gas valve will de-energize and the control will restart the ignition sequence. Recycles will begin and the burner will operate normally if the gas supply returns, or the fault condition is corrected, before the last ignition attempt. Otherwise, the control will go into system lockout. If the control has gone into system lockout, it may be possible to reset the control by a momentary power interruption of ten seconds or longer. Refer to PRECAUTIONARY, SYSTEM LOCKOUT, AND DIAGNOSTIC FEATURES. COOL MODE In a typical system, a call for cool is initiated by closing the thermostat contacts. This starts the 50A66 control s cooling sequence. The compressor is energized and the delay-to-fan-on period begins. After the delay-to-fan-on period ends, the circulator fan is energized at cool speed. The electronic air cleaner (optional) is also energized. After the thermostat is satisfied, the compressor is de-energized and the delay-to-fan-off period begins. After the delay-tofan-off period ends, the circulator fan and electronic air cleaner are de-energized. MANUAL FAN ON MODE If the thermostat fan switch is moved to the ON position, the circulator fan (heat speed) and optional electronic air cleaner are energized. When the fan switch is returned to the AUTO position, the circulator fan and electronic air cleaner (optional) are de-energized.

SYSTEM LOCKOUT AND DIAGNOSTIC FEATURES SYSTEM LOCKOUT FEATURES When system lockout occurs, the gas valve is de-energized. The circulator blower may be energized at heat speed for some faults, and if flame is sensed, the inducer blower is energized. The diagnostic indicator light will flash or glow continuously to indicate system status. (System lockout will never override the precautionary features.) To reset the control after system lockout, do one of the following: 1. Interrupt the call for heat at the thermostat for at least one second, but for less than 20 seconds (if flame is sensed with the gas valve de-energized, interrupting the call for heat at the thermostat will not reset the control). 2. Interrupt the 24 VAC power at the control for at least ten seconds. You may also need to reset the flame rollout sensor switch. 3. After one hour in lockout, the control will automatically reset itself. DIAGNOSTIC FEATURES The 50A66-743 control continuously monitors its own operation and the operation of the system. If a failure occurs, the DS 1 (red) and DS 2 (green) LEDs will indicate a failure code as shown below. 7

TROUBLESHOOTING DIAGNOSTIC TABLE DS 1 (Red) DS 2 (Green) Error/Condition Comments/Troubleshooting Simultaneous slow flash Simultaneous fast flash Simultaneous slow flash Simultaneous fast flash Normal operation Normal operation with call for heat No fault Normal operation Slow flash On Open limit switch Verify continuity through rollout switch circuit Off Slow flash Pressure switch stuck closed/open Alternate slow flash Alternate slow flash External lockout (retries) Slow flash Off Flame sensed with gas valve de-energized Pressure switch stuck closed. Check switch function, verify inducer is turning off. Pressure switch stuck open. Check pressure switch function and tubing. Verify inducer is turning on and pulling sufficient vacuum to engage switch. Failure to sense flame is often caused by carbon deposits on the flame sensor, a disconnected or shorted flame sensor lead or a poorly grounded furnace. Carbon deposits can be cleaned with emery cloth. Verify sensor is not contacting the burner and is located in a good position to sense flame. Ignitor must be positioned to light the gas immediately when the valve opens. If the ignitor has been replaced, verify hot spot position has not changed. Check sensor lead for shorting and verify furnace is grounded properly. Verify the gas is operating and shutting down properly. Flame in burner assembly should extinguish promptly at the end of the cycle. Check orifices and gas pressure. On Slow flash Open rollout switch Verify continuity through rollout switch circuit. On On Module internal fault condition Slow flash Fast flash Low flame sense current Fast flash Slow flash Grounding or reversed polarity Alternate fast flash Alternate fast flash Module ignitor contact failure Module contacts for gas valve not operating or processor fault. Reset control, if condition persists, replace module. Low flame sense current is often caused by carbon deposits on the flame sensor, a poorly grounded furnace or a misaligned flame sense probe. Carbon deposits can be cleaned with emery cloth. Check or improve furnace and module ground. Verify sensor is located in or very near flame as specified by the appliance manufacturer. Verify the control and furnace are properly grounded. Check and reverse polarity (primary) if incorrect. Fault code indicates the module ignitor contacts are not functioning properly. Replace module. HOMEOWNER HELP LINE: 1-800-284-2925 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. white-rodgers.com emersonclimate.com