SIGMADEK, LTD. FIRE TEST REPORT

Similar documents
FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

FUNDERMAX GMBH FIRE TEST REPORT

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Fire Performance of Translucent Systems

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

We Identify and S.T.O.P. Your Noise Problems

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

PERFORMANCE TEST REPORT. Rendered to: SOLATUBE INTERNATIONAL, INC.

ENGINEERING EVALUATION

Public Comment No. 2-NFPA [ Section No ]

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Refrigerating Appliance DOE Test Report

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report of Surface Burning Characteristics Test on Acoustical Panel

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Acoustical Surfaces, Inc.

Abrasion Resistance of Fluoropolymer and polyester Coatings

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Materials Testing by Gregory Havel

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Heat and Smoke Release of a Ceiling-Installed Speaker

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

GUARDIAN FIRE TESTING LABORATORIES, INC.

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

Food Service Technology Center

BCTC CARPET TECHNICAL CENTRE

Declaration of Conformity

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Refrigerating Appliance ErP Test Report

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Classification of Fire Performance of Wall and Ceiling Lining Materials

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Southern California Gas Company Customer Programs Department

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

Food Service Technology Center

Report on Public Input June 2014 NFPA 101

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Transcription:

SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION END DATE 09/13/21 PAGES 9 DOCUMENT CONTROL NUMBER ATI 00537 (07/24/17) RT-R-AMER-Test-2780 2017 INTERTEK

REPORT ISSUED TO SigmaDek, Ltd. PO BOX 47092 Calgary, Alberta T3P 0B9 SECTION 1 SCOPE Intertek Building & Construction (B&C) was contracted by SigmaDek, Ltd., Calgary, Alberta to evaluate the flame spread and smoke developed properties of aluminum extrusion deck board c/w porcelain tile insert. Testing was conducted at the Intertek B&C test facility in York, Pennsylvania. Results obtained are tested values and were secured by using the designated test method(s). A summary of test results and the complete graphical test data is reported herein. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. SECTION 2 SUMMARY OF TEST RESULTS Product Type: Aluminum Extrusion Deck Board C/W Porcelain Tile Insert Series/Model: N/A ASTM E84 Test Results FLAME SPREAD INDEX SMOKE DEVELOPED INDEX 0 5 For INTERTEK B&C: COMPLETED BY: Ben Samson REVIEWED BY: Ethan Grove TITLE: Technician Fire Testing TITLE: Manager Fire Testing SIGNATURE: SIGNATURE: DATE: 10/03/17 DATE: 10/03/17 BTS::ddr This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample(s) tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 07/24/17 Page 2 of 9 RT-R-AMER-Test-2780

SECTION 3 TEST METHOD The specimens were evaluated in accordance with the following: ASTM E84-16, Standard Test Method for Surface Burning Characteristics of Building Materials SECTION 4 MATERIAL SOURCE/INSTALLATION Test samples were provided by the client. SECTION 5 LIST OF OFFICIAL OBSERVERS NAME Ben Samson Scott Gingrich COMPANY Intertek B&C Intertek B&C SECTION 6 TEST PROCEDURE The Steiner Tunnel test apparatus is used to evaluate the surface burning characteristics and smoke development of building materials. The apparatus is considered to be under calibrated conditions when the flame front reaches the end of the tunnel within 5 minutes and 30 seconds (plus or minus 15 seconds) during a red oak test. An initial preheat of the tunnel is performed and the test specimen is installed when the tunnel temperature drops to 105 F ± 5 F. When the test is initiated, the 88 KW dual burner and 240 feet per minute air current creates a flame that extends 4.5 feet down the tunnel. The flame progression is tracked from this point to the exhaust end of the tunnel which is 19.5 feet downstream. An observer simultaneously notes any test specimen anomalies such as melting, dripping, sagging, delamination, fall-out, etc. The smoke that is generated during the test is measured by a photometer. The flame spread and smoke developed data are automatically logged and graphed versus time by a data acquisition and computer system. The Flame Spread Index (FSI) and the Smoke Developed Index (SDI) are based on an area under the curve calculation and the red oak flooring calibration data. Version: 07/24/17 Page 3 of 9 RT-R-AMER-Test-2780

SECTION 7 TEST SPECIMEN DESCRIPTION MANUFACTURER* SigmaDek Ltd. PRODUCT TYPE* Aluminum Extrusion Deck Board C/W Porcelain Tile Insert SERIES/MODEL* N/A COMPOSITION* Aluminum, Porcelain CONDITIONING TIME 72+ hr. SPECIMEN SIZE 9-1/8 in. wide x 94-1/2 in. long THICKNESS 1 in. SPECIMEN SECTIONS 6 TOTAL WEIGHT 38.7 lbs. COLOR Gray / White SIDE TO FLAME* Porcelain Face SUPPORT USED* 1/4 in. diameter steel rods spaced every 24 in. on center MOUNTING METHOD ASTM E84 Appendix X1.1.2.2 SUBSTRATE USED* No substrate was utilized CEMENT BOARD 1/4 in. thick fiber cement board was placed on top of the sample. *From the client's material description and/or instructions Note: Specimens were conditioned as per the requirements of Section 6.4 of ASTM E84. SECTION 8 CODES AND REGULATIONS The 2015 International Building Code (Chapter 8 Interior Finishes, Section 803 Wall and Ceiling Finishes) and NFPA 5000, (Chapter 10 Interior Wall or Ceiling Finish Testing and Classification) classify materials based on their Flame Spread and Smoke Developed indices. The classification criteria are listed below: CLASSIFICATION FLAME SPREAD INDEX SMOKE DEVELOPED INDEX A 0-25 0-450 B 26-75 0-450 C 76-200 0-450 Version: 07/24/17 Page 4 of 9 RT-R-AMER-Test-2780

SECTION 9 TEST RESULTS TEST RESULTS Test Date 09/12/17 Test Operator Ben Samson Flame Spread Index (FSI) 0 Smoke Developed Index (SDI) 5 Red Oak Calibration (% * Min) 101.62 TEST DATA FSI (unrounded) 0.3 SDI (unrounded) 2.7 FS * Time Area (Ft * Min) 0.5 Smoke Area (% * Min) 2.7 Fuel Area ( F * Min) 4318.5 OBSERVATIONS Ignition Time Max Flame Front Advance Time to Max Flame Front Max Temp At Exposed T/C Time To Max Temp Dripping Observed Flaming On Floor Observed After Flame Top Observed After Flame Floor Observed Sagging Observed Delamination Observed Shrinkage Observed Fallout Observed Cracking Observed Observations After the Test 07:04 (Min:Sec) 0.9 Feet 09:35 (Min:Sec) 517.7 F 09:57 (Min:Sec) 10:05 (Min:Sec) 05:42 (Min:Sec) 01:43 (Min:Sec) Version: 07/24/17 Page 5 of 9 RT-R-AMER-Test-2780

SECTION 10 PHOTOGRAPHS Photo No. 1 Exposed Surface of the Test Specimen (Pre-test) Photo No. 2 Unexposed Surface of the Test Specimen (Pre-test) Version: 07/24/17 Page 6 of 9 RT-R-AMER-Test-2780

SECTION 10 (Continued) PHOTOGRAPHS Photo No. 3 Unexposed Surface of the Test Specimen (Post-test) Photo No. 4 Exposed Surface of the Test Specimen (Post-test) Version: 07/24/17 Page 7 of 9 RT-R-AMER-Test-2780

SECTION 11 GRAPHS Version: 07/24/17 Page 8 of 9 RT-R-AMER-Test-2780

SECTION 12 REVISION LOG REVISION # DATE PAGES REVISION 0 10/03/17 N/A Original Report Issue Version: 07/24/17 Page 9 of 9 RT-R-AMER-Test-2780