teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Similar documents
THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

caleffi hydronic valves page 1 of 12

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Mercury Mixing Kit (Code: ME1053)

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Convertible radiator valve for one-pipe systems, centre distance 35 mm

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Thermostatic valves with radiator connection systems

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Radiator Trap Radiator Valve

Multilux 4-Eclipse-Set

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Components for solar heating systems

Radiator Valve Program

WAL-RICH CORPORATION SINCE 1950

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Mikrotherm. Manual Radiator Valves With presetting

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

RA 2000 Series RA 15/6T & TB Conversion Valve

RA2000 Thermostatic Radiator Valves

Self-help Temperature Adjustment

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

HERZ Regulating valve 4002

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

RA15/6T & TB Conversion Valve

Assembly instructions for LK PressPex

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Control valves for floor heating systems. Floor Heating Manifolds

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

IMI Heimeier Kit Hydroca ble

Standard. thermostatic valve body without presetting

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

B2009 compact. Dal 1901 COD

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

B2009 compact. Dal 1901 COD

manifold, for radiators

Radiator valve inserts

HERZ Differential Pressure Control Valve 4002

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

INSTALLATION INSTRUCTIONS

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Flush individual room control for floor heating systems

STRAIGHT AND ANGLED THERMOSTATIC VALVES

BUILT-IN FRIDGE-FREEZER AND BUILT-IN FROST FREE FRIDGE-FREEZER

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

VALVES SECTION 15100

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Thermostatic head with wax sensor

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Thermostatic mixing valves with interchangeable cartridges

Series 1140 and 1141 Temperature Regulators

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

thermostatic valve body with stepless precision presetting

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

DEVIATING VALVES ART K063

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

HE360 Humidifier Installation Kit

GALATEA DOMUS. Dal 1901 COD

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Fixtures Installation

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Dynamic thermostatic radiator valves DYNAMICAL

Installation, commissioning and servicing instructions

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Parts & Material Included

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

INSTALLATION INSTRUCTIONS

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Thermostatic mixing valves with replaceable cartridge for centralized systems

INSTALLATION INSTRUCTIONS

Frost Protection Thermostat

MITICA. Dal 1901 COD

Say heating. Say Herz. HERZ-Supply Engineering

ABLOY CAMLOCKS. Expertise at your service

TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini

TRV 300 RADIATOR VALVES

Transcription:

HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating networks. These valves allow the regulation and control of the water flow in radiators from bi-tube heating networks, keeping the room temperature at the desired value. THERMOSTATIC VALVES SERVICE CONDITIONS Nominal pressure: 10 bar Water Temperature range: Up to 110ºC Room setting range: 6ºC at 28ºC COMPONENTS 1 2 3 4 Item Component Material Treatment 1 Nut European brass CW617N Chrome 2 Coupling European brass CW614N Chrome 3 O-ring NBR 4 Closure cap ABS White color 5 Open - Close European brass CW614N 6 Body European brass CW617N Chrome 7 Sleeve NBR 8 Ring European brass CW614N 9 Nut European brass CW617N Chrome 9 8 7 6 5 PAG. 1/9

COMPONENTS 1 2 3 5 4 Item Component Material Treatment 1 Nut European Brass CW617N Chrome 2 Washer European Brass CW614N Chrome 3 Coupling European Brass CW614N Chrome 4 O-ring NBR 5 O-ring EPDM 6 Handle ABS 7 Stem European Brass CW614N 8 Body European Brass CW617N Chrome 9 Bicone NBR 10 Ring Brass 11 Nut European Brass CW617N Chrome 11 10 9 8 7 6 MAIN CONSTRUCTIVE FEATURES Internal leaktightness The closure mechanism has been designed with a special shaped rubber assuring a prefect closure. A plus in order to increase the reliability agaists over pressures in the network, it has been added in the rear part of the shaped rubber a metallic disc in the rear part. O-ring NBR O-ring EPDM External leaktightness A double EPDM seal placed on the stem ensures the external leak tightness. The system with double seal provides extra security against leaks, aging, wearing,... In the other hand an extra NBR o-ring has been placed in the coupling junction increasing the reliability of the metallic closure. Shaped gasket Metal reinforcement PAG. 2/9

MAIN CONSTRUCTIVE FEATURES O-ring Washer Anti Drip O-ring An EPDM O-ring placed in the coupling and positioned by a washer prevents a possible drip between the radiator and the valve coupling. DIMENSIONS THERMOSTATIC VALVE Screwed angle Size A B C D E 1/2 24.5 1/2 50 1/2 M28 1/2 24.5 1/2 50 1/2 M30 3/8 24.5 3/8 50 3/8 M28 THERMOSTATIC VALVE Compression angle Size A B C D E 1/2 24.5 M24x1.5 50 1/2 M28 PAG. 3/9

DIMENSIONS THERMOSTATIC VALVE Screwed Straight Size A B C D 1/2 71 1/2 1/2 M28 1/2 71 1/2 1/2 M30 D THERMOSTATIC VALVE Angle Compression Anti Drip O-ring C Size A B C D E 1/2 24.5 M24x1.5 53 1/2 M28 B E A C THERMOSTATIC VALVE Screwed Inverted Size A B C D 1/2 47 1/2 1/2 M28 B D 1/2 47 1/2 1/2 M30 A PAG. 4/9

THERMOSTATIC HEAD V3 SERVICE CONDITIONS Sensor type Liquid Maximum working pressure 10 bar Working temperature range Hot water up to 120ºC Room temperature setting range 6ºC a 28ºC Maximum differential pressure 1,2 bar Recommended differential pressure 0,6 bar COMPONENTS Item Component Material Treatment 1 Nut European brass CW617N Nickel 2 Temperature sensor ABS Grey color 3 Main body ABS White color 4 Liquid sensor 5 Distinctive ABS White color 1 2 3 4 5 Thermostatic Head PAG. 5/9

MAIN CONSTUCTIVE FEATURES The thermostatic head includes a temperature selector; it allows the temperature setting in the room where it has been installed, according to the following table: 0 * 1 2 3 4 5 Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat or cold sources. All these factors can modify the proper working of the thermostatic head, changing the relationship shown in the above table position temperature, that means that one position will not correspond to a temperature. DIMENSIONS Size A B C C B M28 81-88 52 M28 M30 81-88 52 M30 A THERMOSTATIC HEAD V4 SERVICE CONDITIONS Sensor type Liquid Maximum working pressure 10 bar Working temperature range Hot water up to 120ºC Room temperature setting range 6ºC a 28ºC Maximum differential pressure 1,2 bar Recommended differential pressure 0,6 bar PAG. 6/9

COMPONENTS 1 2 3 4 5 Item Component Material Treatment 1 Nut European brass CW617N Nickel 2 Temperature sensor ABS Grey color 3 Main body ABS White color 4 Retention ring 5 Liquid sensor ABS White color MAIN CONSTUCTIVE FEATURES The thermostatic head includes a temperature selector; it allows the temperature setting in the room where it has been installed, according to the following table: 0 * 1 2 3 4 5 Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat or cold sources. All these factors can modify the proper working of the thermostatic head, changing the relationship shown in the above table position temperature, that means that one position will not correspond to a temperature. Selector and temperature scale DIMENSIONS Size A B C M28 78-83 45 M28 M30 78-83 45 M30 PAG. 7/9

HYDRAULIC FEATURES THERMOSTÁTIC VALVE SQUARE THERMOSTÁTIC VALVE STRAIGHT 10.000 Flow vs. Loss pressure 10.000 Flow vs. Loss pressure Loss of pressure 1.000 Loss of pressure 1.000 100 100 10 10 100 1.000 10.000 Flow (l/h) 10 10 100 1.000 10.000 Flow (l/h) INSTALATION AND ASSEMBLY LOCATION OF THE VALVE Thermostatic radiator valve shall be fitted at the inlet of the radiator. The valve shall be positioned so that the thermostatic head (sensor component) remains in horizontal position and can detect the temperature of the air in the room. Thermostatic head must not be placed behind curtains or other similar obstructions, and should not be exposed to direct sunlight or other heat sources. CONTROL ADJUSTMENT SCALE Thermostatic head is provided with calibration marks, which correspond to following temperatures: INSTALLATION Before installing the valve ensure that the heating system is shut off and free of dirt in accordance with good plumbing practices. Use the manual closing cap provided with the valve to protect it during installation. 1. Fit the manual closing cap and screw down sufficiently to close the valve. Do not over-tighten. 2. Connect the valve to radiator and tube, fill the system, bleed radiator and check for leaks. 3. Remove the manual closing cap and store it in a safe place for future use. 4. Turn thermostatic head to fully open (position 5) and assemble it on the valve s body, ensuring that the indicator line can be seen. Tighten knurled securing ring by hand. Do not over-tighten or use grips, etc... 0 * 1 2 3 4 5 Close 6ºC 12ºC 16ºC 20ºC 24ºC 28ºC PAG. 8/9

INSTALATION AND ASSEMBLY SETTING THE TEMPERATURE Select the desired room temperature from the table above and turn the knob to align the appropriate number with the arrow on the fixed part of the head. To change the room temperature, readjust the setting. TEMPERATURE BLOCKING (Just available for V3 model) In order to avoid the manipulation of the selected temperatura, the valve has as blocking ring that allows you to block the head in the desired position. In order to block the head temperature, select the desired position and pull the ring upwards. After this maneuver the thermostatic head will remain blocked until the ring is repositioned to its initial position. FROST PROTECTION When heating is not required, and there is a danger of freezing, the valves may be turned to the frost protection setting * which will allow the valves to open if the temperature falls below approx 6ºC. The boiler must remain operational, controlled by a frost protection thermostat. RADIATOR REMOVAL To remove a radiator it is necessary to use the manual shut-off cap supplied with the valve. Remove the thermostatic head and substitute the manual shut-off cap. Close the valve manually and proceed in the normal way. SUMMER OPERATION If the heating system is to be turned off for a lengthy period (eg. during the summer months), it is recommended that all valves are set to the fully open (position 5 ). QUALITY BY TRADITION Av. del Cid, 16 46134 Foios Valencia Spain Engineering departament: Tel: +34 963 171 070 tecnica@valvulasarco.es valvulasarco.com Every product has an impact on the environment during all stages of its life-cycle, including final disposal. All components of these valves can be recycled, deposit the valve in a green or recycled point when no longer useful. Válvulas ARCO, SL reserves the right to change our products and specifications at any time and without prior notice. PAG. 9/9