HVAC Controls Upgrades: Requirement Details ( )

Similar documents
HVAC Controls Upgrades: Requirement Details ( )

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Digital Precise Air Control - DPAC

UNIFIED FACILITIES GUIDE SPECIFICATIONS

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

1 - This title will copy onto other forms Date

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Verasys System Operation Overview Technical Bulletin

HVAC Mandatory Provisions Part II, Page 1

Your Home. Jacco & Assoc.

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

To: Steve Ardolf, MSU Mankato From: Chris Plum, CEE. CC: Tim Ellingson, CEE. Angela Vreeland, CEE Dan Briese, MSU Mankato Date: April 21, 2014.

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Selected Laboratory Energy Efficiency Measures

COMcheck Software Version Review Mechanical Compliance Certificate

Paul McCown, PE, CEM, LEED AP, CxA Sr. Mechanical Engineer SSRCx, LLC Nashville, TN USA

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

COMcheck Software Version Mechanical Compliance Certificate

10+ HVAC Troubleshooting Tips for Healthcare Facilities Jerry Hirsch JCI Facility O&M Performance Development Manager.

COMcheck Software Version Mechanical Compliance Certificate

Civil Engineering Building

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

Feature Summary. I. System

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Continuous Commissioning: A Valuable Partner to Retrofit Projects

SECTION FUNCTIONAL PERFORMANCE TESTING (FPT) PROCEDURES - CONSTRUCTION MANAGER EDITION

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

DX-9100 Applications from Engineering Services

AHU Air Handling Unit Fundamentals. j.ilangumaran

IAQ: Re-tuning Commercial Buildings

ASHRAE Guideline 36 Advanced HVAC Control Sequences

DIGI-VAV APPLICATIONS

Energy-Efficiency Measures List

American University Design Standards

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

BAS Point Trend Data Guidance

Building Automation System (BAS) Design Criteria

Mechanical Compliance Certificate

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

An HVAC Audit of the Canberra Institute of Technology

1.0 Digital Controller

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

The M & V Guided Recommissioning Process. Energy & Water Conservation Program. September 2015 MOO

2009 IECC Commercial Mechanical Requirements

COMcheck Software Version Mechanical Compliance Certificate

August 15, 2013 Page 1 of 19

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Virginia Tech Standards for Building Automation System

Job Name Control Systems Description Date

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Florida Department of Transportation

RCE # April 30, 2013 Centennial School District William Tennent HS, Region 3 ES, Region 1 ES, Region 2 ES

Description of All Alternatives Considered-

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

COMcheck Software Version

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Summary Comparison of Simulation Program Features

ASHRAE/IESNA Standard

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

4. OVERVIEW OF MECHANICAL SYSTEM

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

COMcheck Software Version Mechanical Compliance Certificate

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

CHAPTER 4. HVAC DELIVERY SYSTEMS

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

AABC National Standards for Total System Balance, 7th Edition: A Guided Tour Course Number: CXENERGY1624

Reference Guide for Microprocessor Controller

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

MicroTech Rooftop/RMC

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Submitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner

York 25-Ton VAV Rooftop Unit

2018 International Energy Conservation Code (IECC) Updates

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Computing Services Center

Transcription:

REQUIRED CONTROLS/FEATURES HVAC non CENTRAL PLANT 1) Zone Level Scheduling & Override for all air handlers (supply and exhaust) to match occupied hours by zone DDC or occupancy sensors (OS) allowed. (403.2.4.3, 6.4.3.3) a. By zone/tenant boxes grouped (6.4.3.3.4) b. Easy to change to match changing tenants/zones does not require reprogramming by controls contractor (6.4.3.3.4) c. 7 days and Holidays (403.2.4.3.2, 6.4.3.3.4) d. Override for zone with time limit up to 2 hrs (403.2.4.3.2, 6.4.3.3.1.c) 2) Optimum Start/Stop with Warm up and Cool Down (403.2.4.3.3; 6.4.3.3.3 specifies how, 6.3 p for simple systems >10,000.) a. Optimum Start i. Maximum hours on prior to occupancy (maximum 4 hours) ii. OA closed for warm up (403.2.4.4; 6.4.3.4.2) iii. Use gas pre heat over electric heat if available. iv. OA open for cool down with mechanical cooling locked out (403.2.4.4.6 ventilation purge 1 hr before and precooling) b. Optimum Stop i. Gradually adjust room temperature heating setpoints down and room temperature cooling setpoints up, 1 2 hrs before the scheduled stop. Make the timing and increments adjustable. 3) Unoccupied (night) set back with zone override a. Zone temperature range 80 58 or better ( 403.2.4.3.1; 6.4.3.3.2 10F lower for heating 5F higher for cooling, 4Flower for radiant) b. OA closed for heating (403.2.4.4, 6.4.3.4.2) c. VAV fan boxes only come on to heat spaces AHU stays off for those areas when VAV box can be used to heat d. AHU used for cooling OA no mechanical cooling, minimum number of boxes come on to prevent over pressurization of ducts (403.2.4.4.6 ventilation purge 1 hr before and precooling, 6.4.3.4.2) e. Override for zone with time limit up to 2 hrs (403.2.4.3.2, 6.4.3.3.1.c) 4) Discharge Air Temperature (DAT) Reset (403.4.5.4; 6.5.3.4, 6.5.3.2.3) a. Specific temperature range :65 55F or better (403.4.5.4; 6.5.3.4 at least 25% of diff betw. design SAT and design RAT) b. Based on load heating and cooling signals not OAT (403.4.5.4 or OAT; 6.5.10.2 b,6.5.3.4 or OAT) Page 1 of 7

c. Use Trim and response control sequences and be slow reacting, different interval and different controlling variables controlling this and DAT reset*. Method to assure DAT reset and DSP reset do not fight each other. d. Based on at least two zones and each major zone/floor; cooling only or heating only zones excluded or rooms with constant load, like equipment rooms, shall be have air flow based on the fully reset supply temp (6.5.3.4) e. * Rogue Zone: Alarm for zone excessively driving reset logic and readily allowing operator to remove a zone from the algorithm (6.4.3.10.2 c & d)* 5) Duct Static Pressure (DSP) Reset (403.4.2.2; 6.3.2.3) a. Range 0.4 1.5 wc b. Set through TAB low all heating, high all in cooling with reasonable diversity c. Based on load comparison of actual to required flow or VAV box damper position (403.4.2.2; 6.3.2.3) d. Based on at least two zones and each major zone/floor??; cooling only or heating only zones excluded or rooms with constant load, like equipment rooms, shall be have air flow based on the fully reset supply temp (6.5.3.4) e. Use Trim and response control sequences and be slow reacting, different interval and different controlling variables controlling this and DSP reset*. Method to assure DAT reset and DSP reset do not fight each other. f. Rogue Zone: Alarm for zone excessively driving reset logic and readily allowing operator at the DDC graphic to remove a zone from the algorithm (6.4.3.10.2 c &d) 6) Minimum Outside Air (OA) Ventilation and positive building pressure maintained. a. OA minimum set through TAB based on code required ventilation b. Method to adjust as fans ramp up and down recommended only c. Method to assure building maintains slightly positive pressure with occupied 7) Demand Control Ventilation (DCV) in interior spaces (403.2.5.1; 6.4.3.8) a. Single zone AHUs (atriums and lobbies, gyms/work out rooms, libraries, auditoriums and any room over 500ft with variable occupancy) 8) Inlet Guide Vane upgrade to VFD 9) VAV boxes air and temperature controls a. All boxes i. min at least 30% or ventilation requirements (403.4.5) ii. in fan powered boxes if boxes are capable of it: htg, clg and min ramping of fan based on demand (6.5.2.1.2) iii. SAT Reheat limit of 20F above RAT (6.5.2.1.1) b. New boxes i. ECM motors (403.2.10.3,; 6.5.3.4) ii. TAB and box set up and calibration on boxes replaced iii. htg, clg and min cfm setpoints ramping of fan based on demand (6.5.2.1.2) 10) Air Side Economizer controls (403.3.1.1.3; 6.5.1.1.2) Page 2 of 7

a. Lockout based on demand (on return air temperature not OAT) ( 403.4.1.1.3 table: 403.4.1.4 not when heating; 6.5.1.1.3) b. Integrated mechanical and economizer can run at the same time ( 403.3.1.1.2; 6.5.1.3) c. Not based on MAT d. Mechanical Cooling Lockout based on 55F OAT 11) Room Space temperatures setpoint deadband, with heating and cooling shut off, at least a 5 degree including setpoint restriction overlap between multiple thermostats in a space (403.2.4.2, 6.4.3.1.2, 6.4.3.2) 12) Air side Heat pumps heating stages ( 403.2.4.1.1) a. strip heat off at 38F OAT b. Heat pump, not strip heat, first stage of heating 13) Pre heat locked out: when cooling lock out both mechanical cooling and economizer ( 6.5.2.5) 14) OAT sensor a. in shaded area b. calibrated 15) LAB exhaust and OA air control to match fume hood and room use a. Reduced air flow when hood sashes are down and reduced air flow at night? b. Fume hood air flow testing in all modes and room TAB c. VFD on exhaust fan d. Supply and exhaust VAV boxes VFD on 16) Test and Balance with report (also listed in detailed requirements for sequences adding) a. Determine AHU outside air minimum damper position for required ventilation (required for all projects) note: more accuracy = bigger savings i. Existing: Document existing % min OA damper position; measure existing % min OA cfm temp calc./rough estimate ii. Required: Determine required min OA cfm by AHU 1. RECOMMENDED: Use sf per occupancy types estimates from owner and apply code ventilation requirements by occupancy type 2. OR: Existing design iii. Final: Measure/determine OA damper % to meet requirement b. VAV Boxes or box controls replaced: balance/calibration of box flow rates; determine ventilation rates c. Building Pressure: verify building properly pressurized in all modes of operation d. Duct Static Reset: determine efficient minimum and maximum duct static setpoints e. Differential Pressure Control : determine minimum possible differential pressure setpoint CENTRAL PLANTS 1) Water Source Heat Pumps (403.4.3.3; 6.5.2.2.3) Page 3 of 7

a. At least 20 F between loop heating and cooling setpoint ( 403.4.3.3.1; 6.5.2.2.3 at least 20 F) b. Maximum heating 80 F, min cooling depends on WSHP 2) Differential Pressure (DP) Control Reset (403.4.3.4.2; 6.5.4.2) a. Set through TAB in heating or cooling with reasonable diversity. b. Based on load heating and cooling signals or valve positions (403.4.3.6; 6.5.4.2 based on valve position) 3) Cooling Tower Staging Optimizing a. Stage to use the minimal fan and pumping energy and kw/ton b. Stage on based on CWT setpoint c. VFD, if exists, based on CWT setpoint 4) Condenser water temperature (CWT) reset down to 70F(6.5.5.2) 5) Chilled water temperature (CHWT) reset (403.4.3 at least 25%; 6.5.4.4) a. Based on load zone cooling signals/valves not OAT b. Based on more than two zones and each major zone/floor c. Range at least 5 degrees d. *Rogue Zone: Alarm for zone excessively driving reset logic and readily allowing operator to remove a zone from the algorithm (6.4.3.10.2 c &d) 6) Hot water temperature (HWT) reset (403.4.3 at least 25%; 6.5.4.4) a. Based on load not OAT (6.5.4.4 by load or OAT) b. Bottom of reset range must be in the condensing range (below 140F) if a condensing boiler c. Rogue Zone: Alarm for zone excessively driving reset logic and readily allowing operator to remove a zone from the algorithm (6.4.3.10.2 c &d) 7) Boiler and Chiller Plant lockout on outside air temp (OAT) to prevent simultaneous heating and cooling 8) Efficient Boiler staging/modulating: low fire and fire in parallel if condensing boiler, up to high fire and in series if non condensing (403.4.3) DDC GUI Features 1) AHU graphic in text: a. Balanced OA minimum damper % b. DAT reset range and controlling variable c. Balanced Duct Static Pressure reset setpoints and controlling variable d. Economizer enable setpoint e. CO2 setpoint 2) AHU graphic: name of schedule 3) Central Plant graphic in text: a. Location of Key sensors: OAT sensor(s), differential pressure sensor Page 4 of 7

b. Balanced Differential Pressure setpoint and controlling variable c. HWT reset range and controlling variable d. CHWT reset range and controlling variable e. CWT reset range and controlling variable 4) Floor Plan in text: a. Location of Key remote sensors: OAT sensor(s), CO2 sensor(s), duct static pressure sensor and differential pressure sensor b. AHU zones showing which floor area they serve 5) VAV graphic in text: a. which AHU serves box in text b. primary air temperature c. hot water supply temperature d. design cfm setpoints in text 6) VAV Table: a. which AHU serves box b. Primary air and hot water temperature c. Key points: cfm, DAT, damper and valve signal, heating stages, mode, room temp d. Cfm: setpoints and actual e. Schedule name f. Mode g. Ability to easily remove or add each box from reset logic (DAT, Duct static reset; water temperature reset for central systems) 7) VFDs in text: actual speed of VFD when command signal is 0 (if does not equal 0) 8) Digital easy access to: controls sequences and submittal ; Facility Guide 9) Outside Air Temperature (OAT): location; actual on all pages Page 5 of 7

RECOMMENDED CONTROL SEQUENCENCES 1) Demand Control Ventilation (DCV) in exterior spaces (403.2.5.3) hook to controls a. Garage gas detection, on/off or VFD, occupancy detection if not enclosed or less than 8,000 cfm (403.2.5.3.2; 6.4.3.4.5) b. Loading docks gas or occupancy detection, on/off (403.2.5.3.1; 6.4.3.4.4) 2) VAV setback based on occupancy a. When not occupied no primary air (403.2.5.2) b. When not occupied space temperature deadband increased by at least 4 degrees 3) Demand Control Ventilation (DCV) for Kitchen Hoods: exhaust fans>5000cfm (6.5.7.1.4) 4) Demand Control Ventilation (DCV) in multi zones a. Special approach for AHUs that serve multiple zones to assure ventilation (6.4.3.8) b. Use ASHRAE guidelines and work with PSE EME 5) Door Switches (on/off contact) disable or reset heating and cooling room temperatures, cooling only if OAT> RAT (6.5.10) 6) Water side economizer for chiller plant a. Use cooling towers only (not chiller) when possible 7) Valves to isolate pumping loop: from equipment when not needed a. Water Source Heat Pumps ( 403.4.3.3) i. valves to isolate compressor from water pump (403.4.3.3.3; 6.5.4.5) ii. isolate Cooling tower from water loop ( 403.4.3.3.2.1 or 2) b. Hydronic Heat pump loop (6.5.2.2.3) i. Cooling tower water flow isolated when not needed c. Boiler or Chiller isolation from loops ( 403.4.3.5) 8) Improved Differential Pressure (DP) control: Two way valves for a majority of boxes and AHUs (6.5.4.5 water source heat pumps) 9) Improved outside air (OA) minimum ventilation control: a. additional controls to fine tune OA control to respond to variation from different supply air flows b. For examples: OA measuring station, differential pressure sensors on dampers, supply and return coordination based on TAB 10) Hot water temperature (HWT) reset enhancement ( 403.4.3 at least 25%; 6.5.4.4) a. Based on load zone heating signals/valves not OAT ( 6.5.4.4 by load or OAT) b. Based on more than two zones and each major zone/floor 11) Exterior heater occupancy controls: a. Outside heaters on/off based on occupancy or time switch (403.2.11) b. Enclosed Loading Docks enable/disable heating based on occupancy (403.2.5.3.10) 12) Vestibules heating controls: air curtain and shut off heating when OAT>45F and max setpoint 60 F 13) Cooling Tower VFD ramping controls: in response to CWT setpoint (403.2.1.12.1.1) Page 6 of 7

OTHER REQUIREMENTS Commissioning (Section 408; 6.7.2.4) Functional Performance Tests: provided by PSE (408.2.3, 408.2.2; 6.7.2.4, 6.7.2.3) o WSEC 408.2.3: Written procedures which clearly describe the individual systematic test procedures, the expected systems' response or acceptance criteria for each procedure, the actual response or findings, and any pertinent discussion shall be followed. At a minimum, testing shall affirm operation during actual or simulated winter and summer design conditions and during full outside air conditions. Facility Guide: per outline and specifics provided by PSE (408.1.3.2; 6.7.2.2) o ASHRAE Guideline 0.2: a basic building systems description and operating plan with general procedures and confirmed facility operating conditions, set points, schedules, and operating procedures to properly operate the facility. including: Operating Plan; Building and Equipment Operating Schedules, Set Points, and Ranges; Systems Operation Control Sequences, Limitations, Emergency Shut down Actions. O&M/Staff training: based on Facility Guide (408.1.4) o Intended for the O&M staff that will be monitoring and manipulating system o Meet owner s requirements o Basic understanding HVAC System o Basic understanding of how to work with the controls system o Minimum final capability of O&M staff on controls system: Schedules: which schedule impacts which systems and how to change Setpoints: what are most efficient and how to change Trends: how to set up trends Sequence of Operation: basic understanding of how they work and efficient operation Facility Guide: where is it located and what is in it Page 7 of 7