REACH-IN SAFETEMP (-AAC)

Similar documents
Hoshizaki America, Inc.

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

Hoshizaki America, Inc.

Hoshizaki America, Inc.

CAREL IR33+ CONTROLLER

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Peachtree City is home office for America located about 30 miles south of the Atlanta airport this is were all KM cubers as well as Flakers are built.

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Bottom Mount Refrigerator---Technical Information

FLAKER/DCM SEQUENCE OF OPERATION

Hoshizaki America, Inc.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Upright S-Series. hoshizakiamerica.com

User Guide ems25plus. Page 1. Normal operation. Product interface

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

ERC2 Control Instructions

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

TRAULSEN TECHNICAL BULLETIN

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

Hoshizaki America, Inc.

CAUTION. No-Load Performance, Controls in Normal Position

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

Follett Performance Plus

Instruction Sheet. ERC2 Retrofit Instructions Series Refrigerators/Freezers and SPEC LINE Refrigerators 6000 & SPEC LINE SERIES

1.0 Digital Controller

OPERATION STARTUP TRUE

RSMV Technical Guide

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

FOR SERVICE TECHNICIAN S USE ONLY


User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

ER52 - Evaporator Controller

WaterFurnace FX10 Application Guide Reversible Chiller

Hoshizaki America, Inc.

PARAGON Commercial Refrigeration Controls

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

Heat Pump Defrost Board Replacement Kit

SERVICE MANUAL REFRIGERATION

KM-61BAH KM-101BAH KM-151BAH

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

Dixell Installing and Operating Instructions release 7.0

NO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL

technical bulletin Control Link RSC Installation Instructions

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

CONTROL PANEL INSTRUCTIONS RSQ-4

FOR SERVICE TECHNICIAN S USE ONLY

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

K00364 Electronic Bin Thermostat

I/O ZONE 560/583 AND OPERATION MANUAL

OPERATING INSTRUCTIONS. G214 Software - Version 4

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

TRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Smart Temp. Model

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

FOR SERVICE TECHNICIAN S USE ONLY

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

QD-ENG-68 Controller for Thermoelectric Thermal Management

ReFreeX H426V1 User manual

Installation and Operation Manual

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Service Manual. Modular Crescent Cuber Models KM-901MAJ, MWJ, MRJ/3 KM-1100MAJ, MWJ, MRJ KM-1340MAJ, MWJ, MRJ/3 KM-1601MRJ/3. hoshizakiamerica.

-20 C FZR20/25 LB -30 C FZR20/25 PL

ThermoSaver TM Hot Gas Defrost System

Bottom Mount Refrigerator Technical Information

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Instruction Manual. Commercial Series Refrigerated Kitchen Equipment Models Reach-In S-Series. hoshizakiamerica.com

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Technicians Manual Single Compressor

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Installation and Operation Manual

INSTALLATION INSTRUCTIONS

Service Manual. Modular Crescent Cuber with G Control Board

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Unit Coolers. Installation and Operations Manual

BACnet Points List for Single Compressor Water to Water PROSSWWE-01

Hoshizaki America, Inc.

Installation and Operation Manual

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

Single Zone LCD Thermostat Operating Instructions

OPERATING INSTRUCTIONS

RSMSD Technical Guide

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Service Manual. Modular Crescent Cuber Model KMS-1402MLJ. Including Condensing Unit Models SRK-15J/3. hoshizakiamerica.com

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Scotsman Technical Training. CU50 Cube Ice Machine

Control of the system, MLP RO pump station

Controller for temperature control EKC 202D1

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

Transcription:

Slide 1 REACH-IN SAFETEMP (-AAC) FH1-AAC RH2-AAC-HD The Hoshizaki line of reach-ins consists of two types of refrigerators and freezers. The high end TEMPGUARD (-SSB) and the mid-range SAFETEMP ( AAC). The TEMPGUARD has all the features that you would expect to find in a high-end box such as, solid state control system including alarm and error codes, stainless steel interiors, doors and exterior sides, etc. The unit also has other features found exclusively on Hoshizaki products such as the EverCheck control board system. The TEMPGUARD (-SSB) and SAFETEMP (-AAC) products are available in various configurations some of which are one, two, and three, section refrigerators, one and two section freezers, with half door and glass door options. Combination units are also available with refrigerators and freezers in the same unit. This module will concentrate on the SAFETEMP (-AAC). The TEMPGUARD SSB will be covered in another module. At the end of this module you will find a table with detailed specifications for all current Reach-In models.

Slide 2 -AAC REFRIGERATOR SEQUENCE When the power switch is turned ON, the control board starts the delay timer and energizes the evaporator fan motor and frame heaters (if the Perimeter Heater switch is turned on). After 2.0 minutes the compressor and condenser fan motor start. The evaporator fan circulates air across the coil, and into the cabinet. The cabinet is cooled until the desired set-point temperature is reached. The average pull-down time for an empty box to the factory set point is 21~23 minutes. This pull-down time would obviously vary when product is included in the cabinet. When the set point is reached, the cabinet temperature thermistor signals the control module to stop refrigeration. This signal is simply a change of resistance that causes the control module program to re-act accordingly. (See Temperature Resistance chart below) The compressor and condenser fan motor will stop. The cabinet thermistor will signal the control module to cycle the compressor and condenser fan motor on and off as needed, to maintain the desired cabinet set point temperature. There is always a 2.0 minute restart delay for the refrigeration components. Defrost control: Defrost will initiate by temperature through the defrost thermistor. This thermistor is mounted in the evaporator, if it gets below 13ºF the unit will initiate a defrost cycle and de energizing the compressor and condenser fan motor. The evaporator fan will continue to run. When the evaporator temperature has reached 40ºF the control module will cycle the compressor and condenser fan motor on and continue normal cycling.

Slide 3 -AAC FREEZER SEQUENCE When the power switch is turned ON, the AAC freezer will start in the defrost cycle. The defrost heaters will be energized as well as the frame heaters (if the Perimeter Heater switch is on). After the defrost thermistor that is mounted in the center of the coil, has reached 100 F the defrost heaters will deenergize and a five minute delay timer will start. After five minutes the compressor and condenser fan will energize. When the evaporator temperature reaches 0 F (Approx. 700O at the thermistor) the evaporator fan begins to circulate air across the coil, and into the cabinet. The cabinet is cooled until the desired setpoint temperature is reached. The average pull-down time for an empty box to the factory set point is 21~23 minutes. This pull-down time would obviously vary when product is included in the cabinet. When the set point is reached, the cabinet temperature thermistor signals the control module to stop refrigeration. This signal is simply a change of resistance that causes the control module program to re-act accordingly. The compressor, condenser fan motor, and the evaporator fan motor stop. The cabinet thermistor will signal the control module to cycle the compressor, condenser fan motor, and evaporator fan motor on and off as needed, to maintain the desired cabinet set point temperature. There is always a 2.5 minute restart delay for the refrigeration components. The defrost system for all freezer models uses electric heater strips and is time initiated and temperature terminated through the control module. Freezer defrost can be set to occur 1, 2, 3, 4, 6, or 8 times a day. The factory setting is 6 per day. This means an electric defrost will occur every 4 hours from when the freezer is started. The number of defrost needed per day will vary depending on how each customer uses the reach-in. You may find that more defrost are required if the reach-in is opened frequently or operated in a high humid environment.

When a defrost occurs, def will be displayed. During defrost, the evaporator fan motor, condenser fan motor, and compressor shut down and the electric heaters are energized. The heaters warm the evaporator coil to remove any ice build up. The defrost control thermistor signals the control module to terminate defrost, once the center of the evaporator coil reaches 100 F. This should indicate a clear evaporator coil. Remember that this 100 F is coil temperature and is not circulated throughout the cabinet because the evaporator fan is off. When the coil temperature reaches 100 F at the defrost thermistor, the control module de-energizes the defrost heaters and starts a 5 minute delay timer. After 5 minutes, the compressor and condenser fan motor restart and the evaporator coil begins to cool. Once the evaporator temperature reaches 0 F, the thermistor signals the control module to restart the evaporator fan motor. The electric defrost system is backed up by two additional safeties. A one hour maximum defrost timer starts counting when the defrost begins. If the coil temperature fails to reach 100 F within one hour, this back up timer will terminate defrost and re-start normal cycling. The second safety, a bi-metal switch also backs up the defrost system. This switch is mounted on the top of the evaporator coil. If the temperature at the top of the evaporator coil reaches 120 F, this switch opens to shut down the electric heaters. The control board will continue in defrost with no electric heaters until the one hour timer expires. Pressing the reset at the display panel will clear the E3 alarm.

Slide 4 REACH-IN SAFETEMP (-AAC) CONTROL MODULE The AAC uses a simple control module and two thermistors (Cabinet and defrost) to control the operation of the reach-in. A different controller is used for the Refrigerator and freezer. However the setpoint adjustment procedure is done the same on both controls SET POINT ADJUSTMENT: The following steps will explain how to adjust the temperature set point on the AAC series Refrigerator and Freezer. Press Set on the control module The display should now read SP1 Press Set again Display should now read Current Set point Use the UP/Down arrow keys to change set point Press Set to store. If no button is pressed in 15 seconds, the display will not go to normal and the set point will remain unchanged. Set point is the temperature that the compressor will come on. For Freezers the differential is -6 F for the compressor to turn off. The adjustable set point range for the Freezers is -10 F to 28 F. For Refrigerators the differential is -5 F for the compressor to turn off. The adjustable set point range for the Refrigerators is 37 F to 55 F.

Slide 5 Accessing: -AAC CONTROLLER ADJUSTMENT Press the F Key and the Down Arrow Key together Screen will go blank for 2 seconds then begin the control menu. Press Together There are several menu items that can be adjusted in the-aac control module. However the system was designed and tested with the factory default settings. Therefore only adjustments to set point and defrost frequency (Freezer only) are recommended. In the event that adjustments are needed use the following chart to view these adjustments. To access this menu press the [ To advance to the next display press [ F] ] and the [ F] buttons and release.

Slide 6 -AAC REFRIGERATOR CONTROLLER ADJUSTMENT 1st Command: dif Indicates Cabinet differential setting -06 Factory setting for Refrigerator 2nd Command: HI Maximum Setpoint 28 Default for Refrigerator in F 3rd Command: LO Minimum Setpoint -10 Default for Refrigerator in F 1st Command: dif Indicates next display is cabinet differential setting -05 Indicates cabinet differential is set for -5 F Factory default for refrigerator is -5 F 2nd Command: HI Indicates the next display is the maximum allowable setpoint 55 Indicates a maximum allowable set point of 55 F which is default for refrigerator. 3rd Command: LO Indicates the next display is the minimum allowable set point 37 Indicates a minimum allowable set point of 37 F which is default for refrigerator.

Slide 7 -AAC REFRIGERATOR CONTROLLER ADJUSTMENT 4th Command: CAL Thermistor calibration. XX When replacing Thermistor place Thermistor end in ice water and confirm that Display reads 32 F. If not adjust setting. 5th Command: def 1st command concerning Defrost Cycle In1 Defrost initiation temperature 13 Defrost will initiate at 13 degrees 4th Command: CAL Indicates the next display is for calibration of the thermistor. XX When replacing thermistor, place thermistor end in an ice water bath of 32 F and confirm that the display reads 32 F. If not adjust setting. 5th Command: def The next series of displays refer to the defrost initiation temperature In1 The next display shows initiation temperature 13 Defrost will initiate at 13 F. This is default for refrigerators.

Slide 8 -AAC REFRIGERATOR CONTROLLER ADJUSTMENT 6th Command: Def Second command concerning defrost End Defrost termination temperature 40 Defrost will terminate at 40 F 7th Command: Sho Short Cycle Protection CyC Minimum time Compressor must remain OFF 02 2 Minute minimum OFF time 6th Command: def The next series of displays refer to the defrost termination temperature End Next display shows defrost termination temperature 40 Defrost will terminate at 40 F. This is default for refrigerators. 7th Command: SH0 The next series of displays refer to the Short Cycle Protection CyC Minimum time Compressor must remain OFF 02 2 Minute minimum OFF time

Slide 9 -AAC REFRIGERATOR CONTROLLER ADJUSTMENT 8th Command: COI Sen Temperature of defrost sensor 20 Actual temperature of the Defrost Sensor in F WARNING This unit has been tested WARNING with its default settings. Under normal conditions the only values that should be adjusted are the Setpoint and Defrost frequency 8th Command: COI The next series of displays refer to the temperature of the defrost sensor SEn The next display shots actual defrost thermistor temperature 20 Actual temperature of the defrost sensor in F

Slide 10 -AAC FREEZER CONTROLLER ADJUSTMENT 1st Command: dif Indicates cabinet differential setting -06 Factory setting for Freezer 2nd Command: HI Maximum Setpoint 28 F Default for Freezer 3rd Command: LO Minimum Setpoint -10 F Default for Freezer 1st Command: dif Indicates next display is cabinet differential setting -06 Indicates cabinet differential is set for -6 F Factory default for freezer -6 F 2nd Command: HI Indicates the next display is the maximum allowable setpoint 28 Indicates a maximum allowable set point of 28 F Which is default for the freezer. 3rd Command: LO Indicates the next display is the minimum allowable setpoint -10 Indicates a minimum allowable set point of -10 F which is default for the refrigerator.

Slide 11 -AAC FREEZER CONTROLLER ADJUSTMENT 4th Command: CAL Thermistor Calibration. XX When replacing thermistor place Thermistor end in ice water and confirm that display reads 32 F. If not adjust setting. 5th Command: def 1st Command concerning Defrost Cycle 04 Defrost frequency in hours (ex. 1 Defrost cycle every 4 hours) 4th Command: CAL Indicates the next display is for calibration of the thermistor. XX When replacing thermistor place thermistor end in an ice water bath of 32 F and confirm that the display reads 32 F. If not adjust setting. 5th Command: (Ok to adjusting depending on box application and defrost needs) def The next series of displays refer to the defrost frequency Int The next display shows defrost interval 4 Defrost frequency in hours (ex. 1 Defrost cycle every 4 hours or 6 defrost per 24 hour period) Note: The defrost frequency can be adjusted by using the up and down arrow keys. You must cycle through the remaining steps in this menu before any changes will be recognized.

Slide 12 -AAC FREEZER CONTROLLER ADJUSTMENT 6th Command: def 2nd Command concerning Defrost dur Maximum allowable time for Defrost 60 Equals 60 minute maximum Defrost 7th Command: def 3rd Command concerning Defrost HI Defrost termination temperature 100 Defrost will terminate at 100 F 6th Command: def The next series of displays refer to the maximum allowable time for defrost dur The next display shows maximum defrost duration 60 Equals 60 minute maximum Defrost 7th Command: def The next series of displays refer to the defrost termination temperature HI The next display shows the defrost temperature in F. 100 Defrost will terminate at 100 F

Slide 13 -AAC FREEZER CONTROLLER ADJUSTMENT 8th Command: Sho Short Cycle Protection CyC Minimum time compressor must remain OFF 02 2 Minute minimum OFF time 9th Command: Fan Concerns Evaporator fan operation HI Re-Initiation temperature of Evap. Fan after defrost 00 Default setting is 0 F 8th Command: SH0 The next series of displays refer to the short cycle protection time. CyC Minimum time compressor must remain off. 02 2 Minute minimum OFF time. 9th Command: FAn Next series of displays refer to the re-initiation temperature of Evap. fan after defrost. HI Next display shows the temperature that the evaporator fan will energize after a defrost. 00 Default Setting is 0 F.

Slide 14 -AAC FREEZER CONTROLLER ADJUSTMENT 10th Command: COI Sen Temperature of Defrost Sensor 20 Actual Temperature of the Defrost Sensor in F WARNING This unit has been tested WARNING with its default settings. Under normal conditions the only values that should be adjusted are the Setpoint and Defrost frequency 10th Command: COI The next series of displays refer to temperature of the defrost Sensor. SEn Next display shows actual defrost sensor temperature. 20 Actual Temperature of the defrost Sensor We hope that this training module gives you a basic understanding of the operation of the AAC SafeTemp reach-in refrigerators and freezers. You can access copies of the complete Service Manual at hoshizakiamerica.com or for hard copies please contact your local distributor. If you need further assistance you can contact Technical Support at techsupport@hoshizaki.com or 1-800-233-1940.