Heat Transfer Products. Product Line Update

Similar documents
precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

5. ASSESSMENT RECOMMENDATIONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

On Balance: Heat Rejection Control a Packaged Solution

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Presented By: John Dolan, P.E.

Partial Load Performance Of Refrigeration System

Call us today! (800)

Call us today! (800)

CTI Sponsored Educational Program

How to Cut Chiller Energy Costs by 30%

Agenda and Objectives

Data Centre Cooling Solutions

Compressed Air Systems

Precise Temperature Control; Compact Footprint

Compressed Air Systems. Scott Wetteland, CEM, DNV GL July 2018

Data Centre Cooling Solutions

PPL Electric Utilities Energy Efficiency and Conservation Program

PACKAGED AIR COOLED Product Data Catalog

Call us today! (800)

Midea VFD Centrifugal Chiller Technology

Method to test HVAC equipment at part load conditions

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Evaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study

InRow Direct Expansion

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

REFRIGERATED AIR DRYERS

TrilliumSeries. Condenser

HYBRID ADIABATIC Cooling System

OACS Outdoor Air-Cooled Central Chillers

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

TRIDENT GS SERIES Central Chiller

RECORD SUBMITTAL COVER SHEET

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Evaporative Cooling in a Hot-Dry Climate

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

C13-Series Engineering Guide

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

Increase your flexibility.

GP SERIES Packaged Chillers

RIGID DC LIQUID CHILLER

Temptek Auxiliary Equipment

MTW Series Modular Oil Free Centrifugal Chillers

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

7 THERMAL APPLICATIONS

Parilla Thermal Storage Project Case Study. May Page 1 of 11

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

VertiCool Aurora Engineering Guide

Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives

NEW CHILLER SCHEDULE

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

LOW RECIRCULATION RATE EVAPORATORS

Richard Hiles ClimateMaster

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Chapter-8 Capacity Control of Refrigeration Systems

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Magnetic Refrigeration. Study Case

Head Pressure Control Application Guide

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

Description of All Alternatives Considered-

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

Closing the Loop What s best for your system?

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

commercial refrigeration products

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Outstanding Performance; Application Flexibility

Technical description. Atec.

Air-cooled Screw Chillers Model RTAF G Process

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Air cooled industrial chillers

Technical Development Program

GWP Alternative Refrigerants

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

30GT FLOTRONIC AIR-COOLED CHILLERS

Energy-Saving Industrial Water Chillers

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Liebert CSU3000 Chiller

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Installation Operation Maintenance

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

PRECISION INVERTER-DRIVEN. We Thought of Everything... And Then Some.

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Transcription:

Heat Transfer Products Product Line Update

EP2 Portable Chiller Variable-Speed Compressor Option

What s different with variable-speed option? Fixed-Speed Compressor Units Variable-Speed Compressor Units Air-Cooled (4-30 tons) Water-Cooled (5-40 tons) Remote Condenser (5-40 tons) 3,500 rpm compressor Hot gas bypass for capacity control Full current start AC motor Athena controller standard PLC controller optional Air-Cooled (10 or 20 tons) Water-Cooled (10 or 20 tons) Remote Condenser (not available) 900 rpm to 7,200 rpm compressor Variable-speed capacity control Part-load soft start Brushless DC motor PLC controller standard Athena controller not available

When to consider the variable-speed option Integral Air-Cooled or Water-Cooled condenser units 3 to 8 ton nominal process load (10-ton unit is used) 3 to 16 ton nominal process load (20-ton unit is used)

Key benefits of the variable-speed option Energy Savings Adjustable Capacity Advanced PLC with Color Touch Screen

Energy Savings

Energy Savings

Energy Savings

Adjustable Capacity Changes the compressor speed to control temperature Eliminates wasted energy of a fixed speed compressor and hot gas bypass for capacity control Chiller virtually changes size No more need for multiple compressor size chillers for different size cooling loads.

Advanced PLC with Color Touch Screen Constantly monitors load and adjusts compressor speed for peak efficiency Access to over 150 parameters for complete monitoring and control Large 7 inch color touch screen display for clear display and easy operation

Advanced PLC with Color Touch Screen

Advanced PLC with Color Touch Screen

Advanced PLC with Color Touch Screen

Advanced PLC with Color Touch Screen

Advanced PLC with Color Touch Screen

Advanced PLC with Color Touch Screen

EP2 Variable-Speed Compressor Option When to Consider Quoting Integral Air-Cooled or Water-Cooled condenser units 3 to 8 ton nominal process load (10-ton unit is used) 3 to 16 ton nominal process load (20-ton unit is used) Key Benefits Reduced operating cost from excellent part-load efficiency Variable capacity eliminates the need for multiple size chillers Advanced PLC and 7-inch color touch screen for easy monitoring and control

ESTW Adiabatic Fluid Cooler New Adiabatic Water Control System

New ESTW Adiabatic Water Control System New Hardware Ambient air temperature sensor Ambient air humidity sensor Adiabatic water flow meter Adiabatic water system drain-down solenoid Variable-flow modulating valve instead of solenoid valve for adiabatic water High-efficiency soaker hose water distribution system versus pipe with holes

New ESTW Adiabatic Water Control System

New ESTW Adiabatic Water Control System New Control Features Adiabatic controller calculates optimal adiabatic system flow for peak efficiency, up to 70% reduction in water use versus our original system User can input cost of electrical power and water and the controller will use adaptive control technology to minimizing operating cost by choosing the perfect mix of fan speed and adiabatic system water flow User can set the adiabatic system to favor water savings over total operating cost when water conservation is the main concern User can program the adiabatic water system drain down solenoid to drain after a fixed amount of time of non-use or can program it to drain at a certain ambient air temperature to provide protection from adiabatic system freezing

Unit Data: Adiabatic Evaporative Parameter Notes hydroblu TM Adiabatic Evaporative System Metered Flow Integral Pump Load Data: Water Control Configurable Energy Priority Maximum Load 100%, % of design Fan Motor Control EC Motor VSD NEMA VFD, direct Ambient at 100% load 97 F If staged fans, fan quantity per step Fixed / minimum load 25%, % of design Product Application Cooler Cooler Load varies with ambient temperature. Design heat rejection Btu/hr 11,250,000 11,250,000 Entering fluid temperature F 95.0 95.0 Leaving fluid temperature (LFT) F 85.0 85.0 Power and Water Rates: Inlet dry bulb temperature F 97.0 97.0 Electricity rate $0.10 $ / kwh Inlet wet bulb temperature F 68.0 68.0 Demand charge $15.00 $ / kw / mo. Unit heat rejection capacity Btu/hr 11,250,000 11,250,000 Water supply $4.00 $ / kgal Precooled air (switch point); (blank for dry unit F 73.0 Sewage $5.50 $ / kgal Total number of fans 48 1 Water treatment $5.00 $ / kgal Total fan power, input kw 177.6 71.0 Total air flow rate cfm 841,725 280,575 Minimum fan speed setting (if appl) 10% 25% Spray water pump power, input kw 0.00 6.16 Water intake at design gpm 43.4 36.8 Minimum leaving fluid temperature setpoint F 80.0 80.0 Condenser or condenser water (Yes/No) No No Saturated suction temp. F (if appl) 40.0 40.0 Ambient setpoint to enable water F 73.0 Fan setpoint to enable water use % fan speed 100% Fan setpoint to suspend water use % fan speed 40% Overfeed metering factor (x Evaporation) 1.33 Minimum water rate threshhold % v design 30% Fan power, maximum kw 177.6 71.0 Spray water pump power kw 0.0 6.2 Compressor power, est. at design kw 0 0 TOTAL maximum power kw 178 77 Fan power, annual average kw 56.4 21.3 Spray pump pwr., annual avg. kw 0.0 6.2 Compressor power, annual avg. kw 0 0 TOTAL power, annual avg. kw 56 27 Fan energy kwh/yr 493,894 186,693 Spray water pump energy kwh/yr 0 53,962 Compressor energy kwh/yr 0 0 TOTAL energy kwh/yr 493,894 240,655 Cost of fan electricity USD/yr $81,357 $31,449 Cost of spray pump electricity USD/yr $0 $6,505 Cost of compressor electricity USD/yr $0 $0 TOTAL cost of electricity USD/yr $81,357 $37,954 Water use hours per year hours/yr 2,588 8,760 Water use hours as % of year 30% 100% Water use kgal/yr 3,302 9,260 Water evaporation kgal/yr 2,483 6,945 Chemically treated blowdown kgal/yr 0 2,315 Non-treated water blowdown (to other use) kgal/yr 819 0 Water intake, maximum gpm 50.4 38.7 Average water intake per year gpm 6.3 17.6 Water use, (equiv.) cycles of concentration 4.0 4.0 Water use savings vs evaporative base 64% 0% Cost of water USD/yr $13,208 $96,072 ANNUAL water & energy cost USD/yr $94,566 $134,026 -$39,460 ESTW Adiabatic Unit Economics Complete Economic Utility comparison to justify system premiums.

ESTW Adiabatic Unit Sales Since Introduction in 2015 Twenty (20) Projects Sold! Close to Five Thousand (5,000) Tons Installed! Nearly Two Million Dollars ($2,000,000) in additional Unit Sales! Almost/More than xx Million Dollars of total system volume utilizing Adiabatic units. Start Selling Up! Limit the Competition! Make More Commission $$$$$

ESE Central Chiller New Larger Sizes

ESE Central Chillers New Larger Sizes 100 ton and 120 ton single-circuit 120 ton and 240 ton dual-circuit Water-cooled and remote air-cooled condensers Three compressors per refrigeration circuit for great part-load efficiencies New frame design for better access and minimized floor space

ESE Central Chillers New Larger Sizes 120 Ton Single-Circuit 240 Ton Dual-Circuit

ESE Central Chillers New Larger Sizes Twenty (XX) Projects Sold since introduction in 21##! Close to Five Thousand (5,000) Tons Installed! Nearly Two Million Dollars ($2,000,000) in Unit Sales! Almost/More than xx Million Dollars of total system volume. Use this cost effective solution to help close business! Limit the Competition by using smaller footprint of integrated tank!

Outdoor VFD Screw Compressor Chiller Operating Cost Savings

Central A/C Chillers with VFD Screw Compressors Trane Model RTAF Sintesis (115-500 tons). VFD on one compressor. EC motor condenser fans. 25% more efficient IPLV. Carrier Model 30XV AquaForce (140 or 550 tons). VFD on one compressor. VFD condenser fan motors. 20% more efficient IPLV. Model RTAE Stealth (150-300 tons). VFD on all compressors. VFD condenser fan motors. 40% more efficient IPLV. Sell Up! Save Energy! Limit competition! Earn More Commission $$$$$

TW Multi-Zone Specials Selling UP

TW-P Dual Zone with Custom Options Standard $ 7,350 Customized $ 12,975

We have supplied 6, 8, 10 & 12 Zone Custom Units with Single Power Feed and Common Cooling Water. 6 Zone 8 Zone

System Capabilities What s can we do?

We can provide almost every type of system requested by our customers. Twenty (XX) Projects Sold in 2012 - $xxx in total HT system sales. Twenty (XX) Projects Sold in 2013 - $xxx in total HT system sales. Twenty (XX) Projects Sold in 2014 - $xxx in total HT system sales. Twenty (XX) Projects Sold in 2015 - $xxx in total HT system sales. Twenty (XX) Projects Sold in 2016 - $xxx in total HT system sales. Twenty (XX) Projects Sold in 2017 - $xxx in total HT system sales. Get on board. this train is picking up speed!

NPE 2018 What will be there?

Thermolators on Stack Rack

EP2A-20 Portable Chiller with Variable Speed Compressor

Central Chiller with Integrated Tank & Pumps

Adiabatic Unit

Questions?