MULTIPLEX SELF RECUPERATIVE gas burner

Similar documents
ST 40 Oil Burner. Installation & Maintenance Manual

Installation & Maintenance Manual

Installation & Maintenance Manual

INDITHERM. Low temperature gas burners

Installation & Maintenance Manual

Installation & Maintenance Manual

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Specifications of V-Line burners

Installation Instructions

Indirect gas-fired air heater

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

Installation & Maintenance Manual

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Steam Fundamentals. (in heating & processing applications)

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Eclipse 90 UV Scanner Model A Version 1

Type CG Series Forced Draft Gas Burner

Flame Safeguard Fault Code Diagnostics

Installation, Operation and Maintenance Manual

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

LGB Gas fired boiler

FLAT FLAME AND EXCESS AIR BURNERS

400GL PX (PF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

Self-recuperative burner for gas

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

TC MODULE (FFD) (with Gas Hob)

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

HERRINGBONE HB COMBINED FLUE SYSTEM

A. Product Data: Include rated capacities, furnished specialties and accessories.

SECTION HEATING BOILERS

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

Eclipse Self-Check UV Scanner

400G/L PX (CF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

BENSON LINEAR RADIANT TUBE

DIRECTIVE NO: D-B

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Distributed By: M&M Control Service, INC

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

INDITHERM. Low temperature gas burners

TJERNLUND PRODUCTS, INC.

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Specifications of MULTIFIRE burners

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

It is critical to maintain the Beech Oven and associated equipment on a regular basis, to avoid the possibility of a serious fire or malfunction.

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Electronic Ignition Water Heater

HOW TO USE YOUR 2000 RANGE L.P.G. COOKER OR HOB UNIT

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

QHT Manual for: SU-2A Gas Burner

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

POWER VENTER. Model: PVE Series

THE CORPORATION OF THE CITY OF LONDON. POTTERSBURG POLLUTION CONTROL PLANT FILTER BUILDING ODOUR CONTROL Tender No ADDENDUM NO.

KEY TO COMPONENTS. 1. Heat exchanger 2. Pilot gas pipe 3. Gas injector nozzle 4. Measuring point

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

Telo Shower Mixing Valve TL10016CP

New Power Vented Rheem FVIR Tanks

Mio Concealed Shower Mixing Valve MI40010CP

Figure 10 or Figure 6

Gas-Fired Indoor and Outdoor Duct Furnaces

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

PBG PACKAGED GAS BURNER

Distributed By: M&M Control Service, Inc Building Technologies

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

NMC Nozzle Mix Gas/Oil Combination Burners

User s Information Manual

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Forced draught gas burner

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

TUBE-O-THERM Low Temperature Gas Burners

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

Inta City Concealed Shower Mixing Valve CT80010CP

PVE SERIES POWER VENTER SYSTEM MANUAL

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Sirius FS. Working towards a cleaner future

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Power Flame Incorporated

EUROBOX SERIES TYPES CM... SM... MM...

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Direct Fired Heater Model AD Specification

ECLIPSE INFORMATION GUIDE

Puro Mini Dual Control Shower Mixer PU90010CP

Transcription:

Installation - Maintenance MULTIPLEX SELF RECUPERATIVE gas burner SERIES MPSR The Nu-way Multiplex Recuperative System offers the alternative of a self-recuperative burner or a separate recuperator and burner. the recuperative system is designed to extract expensive waste heat from the flue products of medium to high temperature industrial processes and to pre-heat the cold combustion air, returning heat to the process and so considerably reducing the fuel usage. The system is designed for the modernisation of existing furnaces or for use in new, energy-efficient furnace designs. Applications include forge furnaces, reheating furnaces, intermittent kilns, soaking pits, heat treatment furnaces, crucible furnaces and indirect heating processes. The system nay be used with flue gas entry temperatures up to 1400 C. combustion air makes three passes through the recuperator to give a high level of heat recovery from the hot gases. Depending on the flue gas temperature and burner rating, fuel savings of up to 50% or even more may be achieved. The recuperator design ensures that the combustion air is preheated only by the flue gases and not by the burner or furnace. Low pressure drops through the system giving reduced horsepower on the combustion air/eductor air fan. All internal parts of the unit are manufactured from high grade heat resisting materials and the design ensures that these components are not subject to thermal stress. The design allows for easy dis-assembly to facilitate inspection, cleaning and replacement of internal sections should the need arise. The burner section of this package has all the industry proven features and advantages of the Nu-way Multiplex nozzle-mix burner range. Multiplex nozzles have proven themselves in a total of over 100,000 hours use at pre-heated air temperatures of 500 C to 650 C. Operation can be on-ratio, excess air or excess fuel. In each case a wide turndown range can be achieved. A high tunnel exit velocity assures good heat penetration into the furnace load and prevents short circuiting back through the flue. CONTROLS As a packaged unit the system design simplifies the control system required. All controls are on the cold side of the recuperator eliminating the need for costly high temperature air controls. The burner can be manually or automatically controlled. For on-ratio control it is recommended that the Nu-way double diaphragm proportionator is used. This will ensure close control over a wide turndown and will automatically compensate for varying back pressures through the recuperator as the air becomes preheated. Existing burner shut-off systems and combustion air fans can often be re-used and Nu-way will be pleased to advise. IGNITION AND FLAME FAILURE Burner may be ignited manually, or by direct spark ignition using the well-proven Multiplex arrangement, and where required, flame monitoring is provided using an ultra-violet scanner. MOUNTING The complete unit is mounted in the furnace wall, installation involves little more than that of fitting a conventional burner.

1. INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS All burners are provided with a mounting flange which is pre-drilled to dimensions given on the data sheet. Combustion chamber hire hole should be to required dimensions (See dimensions on data sheet). Screwed studs or alternative fixings should be provided on burner flange holes centres. When the burner is mounted to the furnace front withdrawal distance equal to the overall length of the burner including inner assembly should always be allowed at the rear of the burner unit. Gas pipework into the burner should be such as to include an elbow and union connection to ensure freedom of removal of internal parts of the burner for service. Care should be exercised in assembly of the gas pipework to ensure electrode extensions are not damaged. Care should be taken to ensure that it seats evenly and squarely to the chamber. A gasket, gasket rope or furnace cement should be used to prevent leakage. 2. CONTROLS 1. Burner unit 2. Eductor 3. Double diaphragm proportionator 4. Gas adjusting tee 5. Orifice plate 6. Air inlet 7. Gas inlet Typical scheme showing the use of the Nu-way double diaphragm proporti9nator. This arrangement ensures that the correct gas-air ratio is maintained over the turndown range of the burner at both hot and cold furnace conditions. The control system and components used in conjunction with the Multiplex burner should be in accordance with recommendation and codes of practice set out by British Gas Corporation where the equipment is for use in the UK, and to the relevant authority in other countries. The instructions given by Nu-way assume that these conditions have been met by the plant manufacturers and/or installers. page 2

3. GAS AND ELECTRICAL CONNECTIONS When connecting a gas supply it is desirable to install a manual shut-off valve together with a suitable pipe union at or near the burner. The burner assembly should not be used to support the incoming gas supply, suitable brackets or hangers should be used for this purpose. Care should be taken to ensure that the incoming gas piping is sized correctly to prevent excessive drops, also that gas connections are pressure tight and gas line purged and pressure tested in accordance with local gas authority requirements or legislation. Wiring of the burner should be in accordance with the appropriate wiring standards. A suitable mains isolator should be placed in a convenient location, and the final electrical connections to the burner should be in flexible conduits. It is vital that the live and neutral wires are connected to their appropriate terminal as reversal could present a hazard, also the earth bonding must be checked to ensure a good earth connection (poor earth connections are often the cause of faulty burner operation when using the flame probe detection). Note: Gas piping must not be used for earthing. The burners are all of the expanding flame type pilot system and can use intermittent, interrupted, or semi-automatic flame failure control boxes. 4. ELECTRICAL SEQUENCE FULLY AUTOMATIC SYSTEM 1. Switch panel isolator ON. 2. Programme Time Switch as required. 3. Reset Excess Temp on control panel. 4. Turn OFF/AUTO switch to AUTO for automatic start-up when time switch is in the ON state. 5. Air pressure switch must prove no air. 6. Start burners. Action of time switch switches burners on. 7. Burner controller (LFL1.335) starts light-up sequence. 8. Air control valve drives OPEN. 9. Air control valve must prove OPEN throughout pre-purge period. 10. Air control valve drives CLOSED. 11. Air control valve must prove CLOSED. 12. Ignition transformers are energised. 13. Gas pilot valves are energised. 14. Ignition transformers are de-energised. 15. Flame must be proved on burner. 16. Main gas valves are energised. 17. Release to modulation relay energised. 18. Air control valve comes under control of temperature controller. 19. Burners shut down via time switch, or excess temp., or OFF/AUTO switch. 20. Air control valve drives CLOSED. 5. LOW FIRE (PILOT START GAS AND AIR SETTINGS) (minimum input rate) Set air butterfly valve to give approximately 15mm (0.6 ins) wg air pressure at inlet to burner (above combustion chamber pressure/suction). Slightly crack open gas flow control valve. Initiate start sequence, if burner fails to ignite, slightly increase gas flow at butterfly valve and reset sequence controller and initiate a new start sequence, repeating as many times as necessary to give a smooth start (the burner should not light with an ignition shock or noise) if this is the case the gas flow is generally too high for a safe start-up. N.B: It is recommended that the start gas rate should never exceed 10% of burner rating. page 3

6. FULL FIRE With servomotor linkages still disconnected and flame established manually increase flow rate of air and gas to achieve required output. This will be FULL FIRE position. N.B: Always move air valve first on increasing flame, and gas valve on decreasing flame size. it is dangerous to produce gas rich flames. Reconnect control linkages and drive motor and ensure they are free to travel over full firing range. Check firing range and if necessary adjust characteristics of control valve system for best operation of combustion and turndown required. 7. With burner firing ensure air pressure switch is set for correct burner operation. It should be set to break electrical continuity if the air pressure fails. 8. Observe flame at different firing rates and re-check allied safety control and all process interlocks and controls. OPERATING INSTRUCTIONS TO START (Fully Automatic Previously Commissioned System) 1. Open PILOT GAS COCK and MAIN GAS COCK. 2. Press START or IGNITION BUTTON. TO START (Manual - Previously Commissioned System) 1. Make sure MAIN GAS COCK is closed. 2. Make sure the burner firing rate is at predetermined low fire position. 3. Start any process circulating and exhaust fans. 4. Energise system control panel (if applicable). 5. Start BURNER FAN BLOWER MOTOR. 6. Press IGNITION BUTTON or apply external ignition source. 7. Open MAIN GAS COCK slowly until burner ignites. TO STOP (Either Manual or Automatic System) 1. Close MAIN and PILOT GAS COCK. 2. Allow burner to continue operating until flame goes out (as seen through observation port on rear of burner). 3. De-energise system control panel and BURNER FAN BLOWER MOTOR. 4. If the combustion chamber is under positive pressure allow BURNER BLOWER to run while cooling down system. page 4

MAINTENANCE AND SPARES The following should be carried six-monthly or every 1000 hours, whichever is the shorter:- Turn off gas and electricity supplies. Clean the burner, a clean burner looks better and works better. Check the electrodes, make sure they are clean and set correctly. Check gas pipes and electrical connections. Bearings of electric motors provided with oilers should be lubricated with six drops of light machine oil. Ball bearing motors are normally grease packed for life. Connect a manometer to the test point between the manual gas cock and the safety shut-off valve. Turn the manual gas cock on and then off. Mains gas pressure is then between the valves and this pressure will be indicated on the manometer. Any leakage of gas past the main or pilot safety shut-off valves, or from a pipe joint will reduce the pressure. If this pressure remains constant over a period of not less than one minute, no leakage is taking place. Should gas pressure not remain constant please call a Service Engineer to properly check, clean and test the gas valve system. Turn on the gas and electricity and start the burner. Check the flame signal. Restrict the air inlet to the combustion air fan. The burner should shut down under the action of the air pressure switch. The burner running, close the manual gas cock. The burner will go to lockout and any alarms fitted should operate. Reset the control box. ELECTRODE GAPS Spark Electrode These are pre-bent at the factory and should be set with the internals of the burner removed (withdraw the burner by removing four or eight screws in the back plate casting), after disconnecting the gas supply at the burner union. Gap should be nominally 2.5mm. Replacement of end section can be achieved by unscrewing the final bent section with insulation from the front (nozzle end) of the burner. Flame Failure Electrode (if fitted) These are pre-bent at the factory as is the spark electrode and are replaced in the same way. page 5

For Spares requirements the main burner components are as follows:- Spark and flame failure electrodes are built up as follows:- 1. Back Insulator 2. Compression Fitting 3. Brass Connector Sleeve 4. Washer 5. Internal Insulator (Ignition) 6. Internal Insulator (Flame Probe) 7. Kanthol Ignition & Flame Probes. Note: All enquiries should quote details off burner nameplate. page 6

COMBUSTION AIR REQUIREMENTS SELF RECUPERATIVE SYSTEM 1. Burner unit 2. Eductor 3. Double diaphragm proportionator 4. Gas adjusting tee 5. Orifice plate 6. Air inlet 7. Gas Inlet Typical control scheme showing the use of a double diaphragm proportionator. This arrangement ensures that the correct gas-air ratio is maintained over the turndown range of the burner at both hot and cold furnaces conditions. EDUCTOR AIR SHOULD BE 100% OF COMBUSTION AIR MPSR A B Hot Cap. C Hot Cap. D E 6 28 wg 16 wg 20 wg 26 wg 10 28 wg 16 wg 20 wg 26 wg 15 28 wg 16 wg 20 wg 26 wg 25 28 wg 16 wg 20 wg 26 wg These pressures can be used on the MPHA and MP2 systems when used in conjunction. page 7

COMBUSTION AIR REQUIREMENTS RECUPERATIVE SYSTEM 1. Burner unit 2. Eductor 3. Double diaphragm proportionator 4. Gas adjusting tee 5. Orifice plate 6. Air inlet 7. Gas Inlet Typical control scheme showing the use of a double diaphragm proportionator. This arrangement ensures that the correct gas-air ratio is maintained over the turndown range of the burner at both hot and cold furnaces conditions. EDUCTOR AIR SHOULD BE SAME VOLUME AS COMBUSTION AIR MPSR A B Hot Cap. C Hot Cap. D E 6 28 wg 16 wg 20 wg 26 wg 10 28 wg 16 wg 20 wg 26 wg 15 28 wg 16 wg 20 wg 26 wg 25 28 wg 16 wg 20 wg 26 wg GAS PRESSURE REQUIREMENTS Gas pressures at burner (whether self-recuperative burner, or separate recuperator and MPHA burner) should be 4 wg for design rating of burner.

Enertech Limited, P O Box 1, Vines Lane Droitwich, Worcestershire, WR9 8NA Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk