South Australian Regulatory Requirements

Similar documents
Baseline Data Required for AS

Information Bulletin

Fire Protection, Inspection and Testing Qualifications Forums. Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia)

AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries.

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018

Developments in Australian Standard AS (Emergency Lighting)

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

H&S Forum. Fire Safety Policy Glascote Academy

Australian/New Zealand Standard

NOTTINGHAM CITY HOMES

Fire Safety Management

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

Australian/New Zealand Standard

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Fire Protection Accreditation Scheme (FPAS)

Australian/New Zealand Standard

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Australian/New Zealand Standard

CERTIFICATION SAFETY & BEYOND

Information Bulletin

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Client Advisory Note June 2015:

Fire Safety. A TUC guide for trade union activists

Electrical Safety Policy and Management System

AS/NZS :2008

Workplace Guidelines

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

F I R E S A F E T Y R E G I S T E R

NOT PROTECTIVELY MARKED. Fire Legislation

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Australian/New Zealand Standard

SOUTH AFRICAN NATIONAL STANDARD

PERIODIC ELECTRICAL TESTING POLICY

FIRE RISK ASSESSMENT

AS/NZS :2016

Australian Standard. Security screen doors and security window grilles AS AS 5039

Application Form. Qualified Accreditation

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

What you need to know about. Maintaining essential safety measures in your building

BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES

Inspection Records Schedule- Fire Extinguisher

Compliance Schedule Handbook Prepared by the Ministry of Business, Innovation and Employment

Substations and high voltage installations exceeding 1 kv a.c.

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Substation Signage. Document Number: 1-11-FR-12

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

Statutory Compliance Checklist

AS/NZS 4012:1999 AS/NZS

AS/NZS 3190:2011 AS/NZS

Periodic Electrical Testing Policy

Audit Mapping Document

COMPLYING DEVELOPMENT CERTIFICATE APPLICATION Made under the Environmental Planning and Assessment Act 1979 Sections 85, 85A

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

Australian/New Zealand Standard

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

LICENCE. for. Click on the red box above to activate the Licence Agreement scroll bar.

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

GRAPHICAL SYMBOLS FOR FIRE PROTECTION DRAWINGS

Perth and Kinross Council Development Management Committee 24 April 2013 Report of Handling by Development Quality Manager

Fire Precautions During Construction of Large Buildings. Technical Design Guide issued by Forest and Wood Products Australia

Australian Standard. Safeguarding of machinery

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

AS/NZS :2014

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

Code of Practice on Closed Circuit Television (CCTV)

Australian/New Zealand Standard

Fire Safety Protocol

AS/NZS :1998 AS/NZS ISO

FIRE SAFETY LOG BOOK

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

FIRE SAFETY MANAGEMENT PLAN

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

Essential Services and Inspection Guide Checklist

Fire Safety Register

FIRE SAFETY MANAGEMENT PLANS DEVELOPMENT GUIDE A GUIDE TO DEVELOPING

Australian/New Zealand Standard

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

Interim Australian Standard

Millfield Schools Fire Risk Prevention Policy

Electrical Management

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

Transcription:

South Australian Regulatory Requirements

Australian Legislative Framework Act Act of Parliament Establishes the Law Primary legislation Regulation Subordinate legislation authorised by a specific Act Therefore there is a lawful requirement to comply with its provisions Sets maintenance requirements May reference Codes and Standards Codes Compliance only compulsory if referenced by an Act or Regulation (for example Ministers Specification SA76 is called up by the Development Regulations 2008) Sets minimum technical requirements as if a building regulation May reference other Codes and Standards (i.e. AS1851-2012) Standards Standards are generally voluntary But compliance is compulsory if a specific standard is referenced ( Called Up ) by an Act or Regulation or a referenced Code Can be used to meet a common law duty of care All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Reconciling the building owner / occupier s legislative compliance obligations Building / Development and Fire Legislative Compliance All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

South Australian Legislative Framework RESPONSIBILITY TO MAINTAIN Schedule 1 Regulations Development Act 1993 17 The regulation of the design, construction, quality, safety, amenity or upkeep of buildings, including, for example: (e) The fire safety of buildings, and the provision and maintenance of fire-fighting equipment and other precautions; (k) The maintenance of buildings; All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

South Australian Legislative Framework RESPONSIBILITY TO MAINTAIN Regulation 76 Essential safety provisions Development Regulations 2008 The owner must not use or permit the use of a building to which this regulation applies unless maintenance and testing have been carried out in respect of each essential safety provision of the building in accordance with Ministers Specification SA 76 as in force at the time of the consent. All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Existing Buildings New Building Work (Including alterations or additions to Existing Buildings) Building Regulation associated with Approval Approval Pre Building Regulations 1974 Building Regulations 1974 Development Regulations 1991 Development Regulations 1993 Development Regulations 2008 Development Regulations 2008 No requirement for maintenance As per Part 59 Logbook method As per Ministers Specification SA 32 As per Ministers Specification SA 76 1995 As per Ministers Specification SA 76 2000 Ministers Specification SA76 2015 Required Maintenance Methodology Apply for a new Schedule of Essentials Safety Provisions in accordance with Regulation 76(4)(c) of the Development Regulations 2008 to adopt Ministers Specification SA 76 2015 maintenance methodology New Form 1 Issued listing Essential Safety Provisions and SA76 2015 maintenance methodology No requirement to upgrade Essential Safety Provisions to latest installation standards in order to apply latest maintenance standards Alternative Maintenance Methodology

Regulatory Compliance & SA76 Mary Andruchowycz Chief Project Officer Department of Planning, Transport & Infrastructure

Maintenance of Essential Safety Provisions in Buildings Mary Andruchowycz Chief Project Officer, Building Policy Department of Planning, Transport and Infrastructure June 2015

Introduction Background to maintenance provisions 1977 legislation Fire Safety logbooks 1993 legislation Minister s Specification SA 76 Individual AS 1851 standards Fire Protection - Maintenance Requirements in South Australia

Background People s Palace fire in 1975: 7 people died because an exit door may have been locked Building regulations amended in 1977 to introduce new maintenance provisions Fire Protection - Maintenance Requirements in South Australia

1977 maintenance requirements: Building Regulation 59.2a required owners to- - Inspect, test and maintain in good working order required fire safety matters/things in a building - Maintain and keep logbooks of inspections, tests and maintenance of the fire safety matters - Notify council regarding approved maintenance arrangements for required systems Fire Protection - Maintenance Requirements in South Australia

Part 59 Log-book requirements: Log-books must record: - the date of inspection or test of items - the identity of person making inspection or test - the fire-safety matter being inspected or tested - whether the matter was in good working order - if not, what remedial action was proposed, and - when remedial action was completed and inspected or tested, and the results Fire Protection - Maintenance Requirements in South Australia

1991 maintenance requirements: From 6 June 1991, regulations under the Building Act 1971 required a relevant authority to issue a schedule of essential safety provisions (ESPs) when granting a building approval or on application by a building owner. The building owner could not permit the building to be used unless the ESPs had been maintained. The standards or requirements for maintenance of ESPs were set out in Minister s Specification SA 32 Fire Protection - Maintenance Requirements in South Australia

Part 59 Log-book requirements: Log-book records had to be- - retained by the building owner for 6 years; - kept in an approved fire resistant location; and - made available for inspection at all reasonable times bythe building surveyor; the chief officer (or his nominee); or a member of the Building Fire Safety Committee Fire Protection - Maintenance Requirements in South Australia

1994 maintenance requirements: Regulation 76 requires a relevant authority to issue a schedule of essential safety provisions (ESPs) when- - Granting a building rules consent - Assigning a change of building classification - A building owner applies for one to be issued - Issuing any other certification for building work that complies with the Building Rules Fire Protection - Maintenance Requirements in South Australia

Form 1 - list of ESPs to be maintained Essential safety provision Maintenance and testing required Fire pump sets As prescribed in AS 1851 sections 1 and 3 Fire hydrant installations, including fire mains and booster assemblies As prescribed in AS 1851 sections 1 and 4 Fire sprinkler installations As prescribed in AS 1851 sections 1 and 2 Fire Protection - Maintenance Requirements in South Australia

1994 maintenance requirements: The owner of a building with ESPs must- - provide a certificate of compliance to the council for each installed ESP (signed by the installer) - not use or permit a building to be used unless maintenance and testing of the ESPs have been carried out in accordance with Minister s Specification SA 76 or any former regulations; and - provide adequate annual proof to council that maintenance and testing has been carried out Fire Protection Maintenance Requirements in South Australia

Schedule 16 Compliance certificate Form 2 of Schedule 16 is the appropriate form for providing an ESP certificate of compliance. A Form 2, to be completed by installers and sent to council by the building owner, is usually issued to the applicant with a building rules consent. The Form 2 will list all ESPs to be installed as part of the building rules consent and the Standards to which they must comply. Fire Protection - Maintenance Requirements in South Australia

Form 2 - list of ESPs to be installed Essential safety provision DTS installation standards Fire pump sets Section 6 of AS 2419; sections 4 and 12 of AS 2118.1; and AS 2941 Fire hydrant installations, including fire mains and booster assemblies NCC Volume One Clause E1.3 and AS 2419.1 Fire sprinkler installations NCC Volume One Clause E1.5, Table E1.5, Spec E1.5 and relevant parts of AS 2118.1 Fire Protection - Maintenance Requirements in South Australia

Form 3 - ESPs that have been maintained Essential safety provision Maintenance and testing carried out Fire pump sets As prescribed in AS 1851 sections 1 and 3 monthly and six-monthly service routines Fire hydrant installations, including fire mains and booster assemblies As prescribed in AS 1851 sections 1 and 4 - monthly and six-monthly service routines Fire sprinkler installations As prescribed in AS 1851 sections 1 and 2 monthly, six-monthly and yearly service routines Fire Protection - Maintenance Requirements in South Australia

Regulation 76(3) records to be kept: A reference to maintenance in respect of essential safety provisions includes a reference to replacing the safety provisions and to keeping records relating to the carrying out of maintenance work of the safety provisions. AS 1851 specifies the service records and reports that must be produced and maintained in relation to required maintenance and testing procedures. Fire Protection - Maintenance Requirements in South Australia

AS 1851 - Service records Service records may be captured in the form of - A hardcopy logbook; - Electronic log; or - Tags and labels with hardcopy summary records. Table 1.16.2 of AS 1851 shows what is required for each system or equipment (logbook or tags/labels) Fire Protection - Maintenance Requirements in South Australia

AS 1851 - Logbooks Service records in logbooks must include- - identification of the building and its owner - the date and type of service routine undertaken - the identity of person making inspection or test - the ESP serviced and/or checked and its location - details of any non-conformance or defect found - what remedial action was undertaken - name of person who carried out the maintenance Fire Protection - Maintenance Requirements in South Australia

AS 1851 - Yearly condition reports Yearly condition reports, which summarise the service records for the year s maintenance activities, are required under AS 1851 to be provided by maintenance service providers to building owners. Building owners will rely on these records when certifying each year that maintenance and testing have been carried out on the ESPs in the building. Fire Protection - Maintenance Requirements in South Australia

Minister s Specification SA 76-2015 A performance requirement has been introduced into the 2015 edition of Min Spec SA 76 and the maintenance service routines in AS 1851-2012 are deemed to satisfy the performance requirement. ESPs must continue to be capable of performing to a standard no less than the standard they were originally required to achieve. Fire Protection - Maintenance Requirements in South Australia

Minister s Specification SA 76-2015 Alternative maintenance procedures to those listed in Min Spec SA 76 may be allowed but they must be listed on the schedule 16 forms issued by the relevant authority (ie they must be approved). The appendices to Min Spec SA 76 contain advice about alternative solutions; existing buildings; maintenance records; and referenced documents. Fire Protection - Maintenance Requirements in South Australia

Minister s Specification SA 76-2015 When an existing building is being altered or added to and the work involves ESPs, Min Spec SA 76 now requires the relevant authority to issue a new schedule that includes all the ESPs installed in the building, whether existing or new. This means that the building owner will then have to change over to AS 1851-2015 maintenance routines for all ESPs in that building. Fire Protection - Maintenance Requirements in South Australia

Summary Building owner must ensure installed ESPs comply. Relevant authority must issue a schedule of ESPs Form 1 ESPs to be installed and maintained Form 2 Installation standards for ESPs Form 3 ESPs that have been maintained. Contractors must maintain ESPs in accordance with Min Spec SA 76 or any former regulations that applied at the time of installation. Fire Protection - Maintenance Requirements in South Australia

Reconciling other Regulatory Compliance Obligations Chris Wyborn Engagement and Education Manager FPA Australia

Reconciling the building owner / occupier s legislative compliance obligations Workplace Health & Safety Building / Development and Fire Legislative Compliance All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Legislative Requirements for Maintenance (WHS) Section 17. Management of risks A duty imposed on a person to ensure health and safety requires the person a) to eliminate risks to health and safety, so far as is reasonably practicable; and b) if it is not reasonably practicable to eliminate risks to health and safety, to minimise those risks so far as is reasonably practicable. Work Health and Safety Act All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Legislative Requirements for Maintenance (WHS) Section 275 - Use of codes of practice An approved code of practice is admissible in the proceeding as evidence of whether or not a duty or obligation under this Act has been complied with. Work Health and Safety Act The court may rely on the code in determining what is reasonably practicable in the circumstances to which the code relates. All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

SafeWork SA Use of Codes of Practice Codes of Practice give detailed practical guidance on how to comply with requirements and obligations under work health and safety laws. They are used in addition to the Act and Regulations and should always be followed, unless there is another solution which achieves the same or a better standard of health and safety in your workplace. All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Legislative Requirements for Maintenance (WHS) Regulation 43. Duty to prepare, maintain and implement emergency plan Work Health and Safety Regulations A person conducting a business or undertaking at a workplace must ensure that an emergency plan is prepared for the workplace All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Legislative Requirements for Maintenance (WHS) Code of Practice WH&S Act All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Legislative Requirements for Maintenance (WHS) the use and maintenance of equipment required to deal with specific types of emergencies (for example, spill skits, fire extinguishers, early warning systems such as fixed gas monitors or smoke detectors and automatic response systems such as sprinklers All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Reconciling the building owner / occupier s legislative compliance obligations Workplace Health & Safety Common Law Duty of care Building / Development and Fire Legislative Compliance All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Duty of Care a requirement that a person act toward others and the public with watchfulness, attention, caution and prudence that a reasonable person in the circumstances would. An individual or a corporation such as the owner, occupier, employer or manager will have a common law duty of care to maintain fire protection systems and equipment to demonstrate that they have met their duty to others under their supervision or care If a person's actions do not meet this standard of care, then the acts are considered negligent, and any damages resulting may be claimed in a lawsuit for negligence All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095

Reconciling the building owner / occupier s legislative compliance obligations Workplace Health & Safety Common Law Duty of care Dangerous Goods Building / Development and Fire Legislative Compliance Industry Specific All slides are Copyright of FPA Australia 2015 Content from AS1851-2012 reproduced with permission from SAI Global Ltd under Licence 1301-c095