ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

Similar documents
ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

MBR. Multi-Position. Modular Blower

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

AVPTC Multi-Position, Internal Txv

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

AVPTC Multi-Position, Internal Txv

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

AVPTC. Air Handler 1½ to 5 Tons

AVPTC Multi-Position, Internal Txv

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

PRODUCT SPECIFICATIONS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MERIT Series R-410A - Upflow / Horizontal

FEM4X. Product Specifications FAN COILS /14/15

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Bosch BVA Series Air Handler

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

13 GEP A L P - 1 A

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

TECHNICAL SPECIFICATIONS

MERIT Series R-410A - Upflow / Horizontal

Ruud Standard Efficiency Air Handler

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Bosch BVA Series Air Handler

Commercial High-Efficiency Condensing Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

RGE 13 A T - 1 A

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

WAHL A Product Specifications

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

AIR HANDLERS AIR HANDLERS

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

REM4P, REM4X. Product Specifications

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

TECHNICAL SPECIFICATIONS B6VMMX

Ruud Standard Efficiency Air Handler

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

PAJ3. Product Specifications

MERIT SERIES Up Flow / Horizontal

Concealed Ducted Split Series R-407C MBH

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Split System Cooling Product Data

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Condensing Units & Air Handlers

HIGH EFFICIENCY AIR HANDLER

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

INSTALLATION INSTRUCTION

Dimensions H x W x D in. (mm)

PRODUCT SPECIFICATIONS

Modular Multi-position Air Handler

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

VERTICAL MOUNT AIR HANDLERS

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Transcription:

ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features Check flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum fin coil Direct-drive, resilient-mount, multi-speed motor Sequence-controlled and rust-resistant nickel chromium heating elements of 5, 6, 8 and 10 kw High-efficiency evaporator coil Quiet operation Models with EEM motors: ACNF25 & ACNF31 Models with PSC motors: ACNF18, ACNF24, & ACNF30 Available with and without heat AHRI Certified; ETL Listed Primary/secondary drain connection in a high-temperature plastic drain pan Suitable for free-return installation (non-ducted return air) Galvanized-steel construction Factory-installed pull-type disconnect Easy service access * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-DACNF www.daikincomfort.com 1/16 Supersedes 11/15

Nomenclature A C N F 24 05 1 6 AA 1 2 3 4 5,6 7,8 9 10 11,12 Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application C - Ceiling Mount Units Cabinet Finish N - Uncased Expansion Device F - Flowrater *Not used for inventory management Refrigerant 6 = R- 410A or R- 22 Electrical 1-208/240 V, 1 Phase, 60 Hz Heater Kit 00 = No Heat 06 = 6 kw Nominal Capacity Range 03 = 3 kw 08 = 8 kw 18 = 1½ Tons (PSC Motor) 25 = 2 Tons (EEM Motor) 05 = 5 kw 10 = 10 kw 24 = 2 Tons (PSC Motor) 31 = 2½ Tons (EEM Motor) 30 = 2½ Tons (PSC Motor) 2 www.daikincomfort.com SS-DACNF

Product Specifications ACNF18 001 ACNF18 051 ACNF18 061 ACNF18 081 ACNF24 001 ACNF24 051 ACNF24 061 ACNF24 081 Performance Ratings Cooling (BTU/h) 18,000 18,000 18,000 18,000 24,000 24,000 24,000 24,000 Piston Size² 0.051 0.051 0.051 0.051 0.057 0.057 0.057 0.057 Blower Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 6.31 Width 6.75 6.75 6.75 6.75 8.25 8.25 8.25 8.25 Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Blower Motor FLA 0.72 0.72 0.72 0.72 1.34 1.34 1.34 1.34 HP 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4 Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Min Circuit Ampacity @ 230V 0.9 27 33.5 40.6 1.68 27.8 34.3 41.3 Min Circuit Ampacity @ 208V 0.9 23.5 29.2 35.3 1.68 24.3 29.9 36.1 Max. Overcurrent Device @ 230V 15 30 35 45 15 30 35 45 Max. Overcurrent Device @ 208V 15 25 30 40 15 25 30 40 Minimum Voltage VAC 197 197 197 197 197 197 197 197 Maximum Voltage VAC 253 253 253 253 253 253 253 253 Electric Heat kw @ 230 Volts 0.0 4.8 6.0 7.3 0.0 4.8 6.0 7.3 BTU/h @ 230 Volts 0 16,400 20,500 24,900 0 16,400 20,500 24,900 Ship Weight (lbs) 59 59 59 59 69 69 69 69 ¹ CFM @.3 static ²Shipped with Coil Notes For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana outdoor unit. When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the AC unit that has electric heat with a heat pump, order HEAT MP SHUT OFF KIT HPSK- 0 1. The ACXX-00 units do not require this kit. SS-DACNF www.daikincomfort.com 3

Product Specifications ACNF24 101 ACNF25 0016 ACNF25 0516 ACNF25 0616 ACNF25 0816 ACNF25 1016 ACNF30 001 ACNF30 051 Performance Ratings Cooling (BTU/h) 24,000 24,000 24,000 24,000 24,000 24,000 30,000 30,000 Piston Size² 0.057 0.055 0.055 0.055 0.055 0.055 0.061 0.061 Blower Diameter 6.31 6.31 6.31 6.31 6.31 6.31 6.75 6.75 Width 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Blower Motor FLA 1.34 2 2 2 2 2 1.34 1.34 HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Min Circuit Ampacity @ 230V 54.9 2.5 28.6 35.1 42.2 55.8 1.68 27.8 Min Circuit Ampacity @ 208V 47.8 2.5 26.1 32.0 38.4 50.7 1.68 24.3 Max. Overcurrent Device @ 230V 60 15 30 40 45 60 15 30 Max. Overcurrent Device @ 208V 50 15 30 35 40 60 15 25 Minimum Voltage VAC 197 197 197 197 197 197 197 197 Maximum Voltage VAC 253 253 253 253 253 253 253 253 Electric Heat kw @ 230 Volts 9.8 0.0 4.8 6.0 7.3 9.8 0.0 4.8 BTU/h @ 230 Volts 33,500 0 16,400 20,500 24,900 33,500 0 16,400 Ship Weight (lbs) 69 69 69 69 69 69 79 79 ¹ CFM @.2 static Note: When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the AC unit that has electric heat with a heat pump, order HEAT MP SHUT OFF KIT HPSK-01. The ACXX-00 units do not require this kit. 4 www.daikincomfort.com SS-DACNF

Product Specifications ACNF30 061 ACNF30 081 ACNF30 101 ACNF31 0016 ACNF31 0516 ACNF31 0616 ACNF31 0816 ACNF31 1016 Performance Ratings Cooling (BTU/h) 30,000 30,000 30,000 30,000 30,000 30,000 30,000 30,000 Piston Size² 0.061 0.061 0.061 0.059 0.059 0.059 0.059 0.059 Blower Diameter 6.75 6.75 6.75 6.75 6.75 6.75 6.75 6.75 Width 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Blower Motor FLA 1.34 1.34 1.34 2 2 2 2 2 HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Refrigerant Line Connection Size Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Min Circuit Ampacity @ 230V 34.3 41.3 54.9 2.5 28.6 35.1 42.2 55.8 Min Circuit Ampacity @ 208V 29.9 36.1 47.8 2.5 26.1 32.0 38.4 50.7 Max. Overcurrent Device @ 230V 35 45 60 15 30 40 45 60 Max. Overcurrent Device @ 208V 30 40 50 15 30 35 40 60 Minimum Voltage VAC 197 197 197 197 197 197 197 197 Maximum Voltage VAC 253 253 253 253 253 253 253 253 Electric Heat kw @ 230 Volts 6.0 7.3 9.8 0.0 4.8 6.0 7.3 9.8 BTU/h @ 230 Volts 20,500 24,900 33,500 0 16,400 20,500 24,900 33,500 Ship Weight (lbs) 79 79 79 79 79 79 79 79 ¹ CFM @.2 static Note: When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the AC unit that has electric heat with a heat pump, order HEAT MP SHUT OFF KIT HPSK-01. The ACXX-00 units do not require this kit. SS-DACNF www.daikincomfort.com 5

Dimensions LIQUID LINE 21 ELECT. HEATER LOCATION 3/4 10 D 1 SUCTION LINE CONTROL BOX THIS END: SUPPLY VOLTAGE WIRING OPPOSITE END: LOW VOLTAGE WIRING A B FRONT VIEW 4⅜ TOP VIEW 11¼ 4⅝ SECONDARY DRAIN 3/4" FEMALE NPT PLASTIC DRIN PAN C 2⅜ PRIMARY DRAIN 3/4" FEMALE NPT ACNF18 ACNF24 ACNF25 ACNF30 ACNF31 A 37¼" 43¼ 43¼ 49¼ 49¼ B 34¾ 40¾ 40¾ 46¾ 46¾ C 30 36 36 42" 42" D 6½ 6½ 6½ 6½ 6½ 6 www.daikincomfort.com SS-DACNF

Airflow Data Model ACNF18**** ACNF24**** ACNF25**** ACNF30**** ACNF31**** Motor Speed CFM delivered against External Static Pressure 0.1 0.2 0.3 0.4 0.5 High 710 660 590 515 435 Low 650 595 540 480 390 High 955 880 820 740 675 Low 885 840 775 725 620 T5 969 912 854 798 778 T4 969 912 854 798 778 T3 802 776 690 641 584 T2 680 610 550 484 431 T1 680 610 550 484 431 High 1,075 1,005 920 820 730 Low 945 890 835 760 650 T5 999 928 868 824 764 T4 999 928 868 824 764 T3 871 798 750 687 614 T2 763 695 625 548 478 T1 763 695 625 548 478 Note: Airflow data for 240 Vac with dry coil and no filter in place. Heating Capacity/kW Correction Factor Supply Voltage 240 230 220 210 208 Correction Factor 1.08 1.00 0.92 0.84 0.82 (Multiply the 230-volt capacity by factors) SS-DACNF www.daikincomfort.com 7

Wiring Diagram ACNF18/ 24/ 30 L1 POWER SUPPLY L2 DISC DISC 208/240 VOLTS DISC DISC * HTR2 FL * * FL FL TL T1 HTR2 TL * HTR1 * TL * L1 HC FL HTR1 TL HC L2 T2 EBTDR EM SEE NOTE 1 NC NO FC LO L1 L2 WH BR T1 T2 HC GR XFMR-R R NO XFMR-C COM C TR NC FC G SU EBTDR SEE NOTE 4 YL BR SEE NOTE 1 EM C 208V 240V 24V 24V GR WH BR GR SEE NOTE 5 SEE NOTE 2 EBTDR COLOR CODE WH WHITE GR GREEN ACK RPLE RED BR BROWN YL R TR YELLOW UE 208V COMPONENT CODE 240V DISC DISCONNECT SWITCH EM EVAPORATOR MOTOR EBTDR ELECTRONIC OWER TIME DELAY RELAY FL FUSIE LINK C 24V HI HC WH COM GR WIRE CODE HIGH VOLTAGE FACTORY WIRING LOW VOLTAGE HIGH VOLTAGE FIELD WIRING EBTDR LOW VOLTAGE NOTE 2 NOTES: 1) TO PLACE UNIT IN LOW SPEED, REMOVE ACK MOTOR LEAD FROM ELECTRONIC OWER TIME DELAY RELAY (EBTDR) COM TERMINAL AND REPLACE WITH RED MOTOR LEAD. 2) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. USE N.E.C. CLASS 2 WIRE. 3) ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT & INTERCONNECTING WIRES OF HEATER #2 ARE DELETED WITH SINGLE HEATING ELEMENT UNITS. BR C G 4) EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN "G" IS DE-ENERGIZED. 5) FOR 208VAC APPLICATIONS MOVE BOTH RED WIRES TO CENTER TAP. SEE NOTE 2 SEE NOTE 5 FC FAN CAPACITOR TL THERMAL LIMIT TR TRANSFORMER HTR HEATER ELEMENT HC HEATER CONTACTOR Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 0140A00278-D 8 www.daikincomfort.com SS-DACNF

Wiring Diagram (No Electric Heat) ACNF18/ 24/ 30 Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-DACNF www.daikincomfort.com 9

Wiring Diagram ACNF25/ 31 NOTES: 1. RED WIRE TO BE ON TRANSFORMER TERMINAL "3" FOR 230 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. FIELD CONNECTIONS SEE NOTE 2 USE N.E.C CLASS 2 WIRE 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAPS NEEDS TO BE CHANGED, CONNECT APPROPRIATE WIRE FROM MOTOR TO "Y" FROM THERMOSTAT/CONDENSER (SEE TAE-1). 3. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. 4. COLOR CODES: - ACK - UE BR - BROWN GR - GREEN - RPLE - RED WH - WHITE YL - YELLOW PK - PINK 5. WIRING CODE: FACTORY WIRING: HIGH VOLTAGE LOW VOLTAGE FIELD WIRING: HIGH VOLTAGE DISC C 6. COMPONENT CODE: C - CONTACTOR DISC - DISCONNECT SWITCH EM - EVAPORATER MOTOR F - FUSE HTR - HEATER ELEMENT TL - THERMAL LIMIT TR - TRANSFORMER MC - MOTOR CONTROL BOX WIRE COLOR BTUh RPLE 18000 PINK 24000 YELLOW TAE-1 HIGH CFM OPTION Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. L2 L1 GR BR WH OPTIONAL CONNECTION UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR CAPPED MOTOR CONNECTIONS ONLY ONE WILL BE CONNECTED (SEE NOTE 2) HTR 1 HTR 2* PK YL SEE NOTE 3 T2 T1 WH WH BR GR PK YL WH SEE NOTE 1 EM 1 2 3 4 5 MC C L G N 1 2 3 5 24V 4 240V TR GR/YL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. TL1 TL2* F 0140A00381-A 10 www.daikincomfort.com SS-DACNF

Wiring Diagram (No Electric Heat) ACNF25/ 31 NOTES: 1. RED WIRE TO BE ON TRANSFORMER TERMINAL "3" FOR 230 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. FIELD CONNECTIONS SEE NOTE 2 USE N.E.C CLASS 2 WIRE UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR CAPPED 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAPS NEEDS TO BE CHANGED, CONNECT APPROPRIATE WIRE FROM MOTOR TO "Y" FROM THERMOSTAT/CONDENSER (SEE TAE-1). GR MOTOR CONNECTIONS ONLY ONE WILL BE CONNECTED (SEE NOTE 2) 3. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. PK YL WH WIRE IS NOT USED FOR 'NO HEAT' VERSION 4. COLOR CODES: - ACK - UE BR - BROWN GR - GREEN - RPLE - RED WH - WHITE YL - YELLOW PK - PINK DISC 5. WIRING CODE: FACTORY WIRING: HIGH VOLTAGE LOW VOLTAGE FIELD WIRING: HIGH VOLTAGE 6. COMPONENT CODE: C - CONTACTOR DISC - DISCONNECT SWITCH EM - EVAPORATER MOTOR F - FUSE HTR - HEATER ELEMENT TL - THERMAL LIMIT TR - TRANSFORMER MC - MOTOR CONTROL BOX WIRE COLOR BTUh RPLE 18000 PINK 24000 YELLOW TAE-1 HIGH CFM OPTION EM GR PK WH 12345 MC CL GN YL GR/YL 1 2 3 5 24V 4 240V TR SEE NOTE 1 Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. F 0140A00380-B SS-DACNF www.daikincomfort.com 11

Accessories HPSK-01 Model Description Heat Pump Shut-off Relay Kit Louvered Ceiling Access Panels CAP-1/ 1L Fits ACNF18 CAP-2/ 2L Fits ACNF24/ 25 CAP-3/ 3L Fits ACNF30/ 31 Our continuing commitment to quality products may mean a change in specifications without notice. 2016 Houston, Texas Printed in the USA. 12 www.daikincomfort.com SS-DACNF