CONTENTS NBM-06 Bell (6") Page 1

Similar documents
SOUNDER CONTROL MODULE SCM-AS4

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Emergi-Lite Orbis detectors

The complete conventional fire warning system

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

Industries. As a premier global manufacturing company, we believe that great brands are

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Conventional Fire Detection

LEAKSTOPPER RANGE Multizone water leak detection systems

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Fire Signalling. Signalling Solutions

Touch Screen 1 loop Addressable Fire Alarm Panel

Addressable and Conventional Fire Protection

EFBW series - BiWire Ultra control panel

ELECTRONIC SOUNDER STROBE Model : AVD-C407

LEAKSTOPPER 1 Single zone water leak detection system

Evolution Analogue Addressable Fire System

Xenex Conventional Fire Detection & Alarm System

Analogue addressable devices

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

IST IST /110 IST /220

An introduction to... Sigma

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Opal TM AV Devices. Data Sheet. Benefits

Eaton is a global leader with expertise in:

YO3 - YO4 / YL4 - YO5 / YL5

Fire Signalling. Signalling Solutions

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

DB5 Intrinsically Safe Sounder Type DB-5

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Industrial Signalling. Signalling Solutions

Product Manual Standard Asserta Sounder Range

Intelligent Security & Fire Ltd

Cooper Industries (UK) Ltd

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Opal TM AV Devices. Data Sheet. Benefits

Fire Signalling. Signalling Solutions

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Industrial Signalling

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MINERVA MZX125 Digital Addressable Fire Detection System

CONVENTIONAL AUDIBLE VISUAL

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

FlexSQUARE Square shaped beacons

Conventional Leaflets

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Intellia Sounder Bases and Sounder Beacon Bases

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

OPERATION AND INSTALLATION MANUAL

INSTRUCTION & SERVICE MANUAL

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Fire Product Catalog

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

E2S Datasheet v10a

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Intelligent Security & Fire Ltd

Emerald 3000 MK3 GJD010 Lighting Controller

Multi Tone Alarm Sounders A

Application, Installation, Operation & Maintenance Manual

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS

LF-4000 Series Conventional Fire Alarm Control Unit

4 wire conventional alarm system

XP95 Sounder VAD Base

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

MULTIFUNCTION ALARM SYSTEM TYPE ED510 FIRE LEVEL GAS ZONE 1 ZONE 2 ZONE 1 ZONE 2 SENSOR 1 SENSOR 2 ALARM FAULT TEST ON TEST OFF

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Solution F2. Fire Alarm Control Panels one step ahead.

Contents. Security. Page

Installation, Operating and Maintenance Manual

INPUT / OUTPUT MINI MODULES

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Conventional Audible Visual Range

L-Series, Emergency Communication Devices

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

industrial, safety and security signalling products reference catalogue 2008/9

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Installation and user manual for the BiWire / Conventional Repeater Panel

Door Release Power Supply

INSTRUCTION MANUAL A131 High Level Audible Warning System

Conventional Fire Control Panel

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Menvier Fire System MF9300

Surveyor Envoy-MINI 4

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

EXTINGUISHING AGENT RELEASE MODULE

Auer - Signal tower ECO Ø70 mm modular

Transcription:

CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder Page 3 VPR-SA2-R or W Viper Sounder Page 4 NCP-K (470) Manual Call Point - Page 5 NCP-K470-WP Manual Call Point (Weatherproof IP65 version) - Page 5 STA-R1 Remote LED - Page 6 NBM-06 & NBM-08 BELLS 1 of 8 152mm (6") 2mm (8") IB-R-SW2-24 Beacon - - Page 7 85mm FL-RL-RD Sounder/Beacon - Page 7 1992ROSH-DB IP65 Sounder - Page 7 NBM-06 & NBM-08 BELLS The NBM -06 bell is motorised in operation and is of lightweight, aluminium alloy construction painted red. The NBM-06 and NBM-08 are designed specifically for applications where low current consumption is a requirement. The NBM-08 is a solenoid type bell. The NBM-06 fixing bracket is suitable for all types of conduit fittings including BESA and the bell may be suspended on the bracket whilst terminating cables. The motors are polarised and suppressed. The NBM-08, when used externally, (increase to IP65), requires a weatherproof gasket box part number WGB/P. NBM-06 Supply Voltage 18-30Vd.c. Operating Current 25mA, Sound Output 93/95dB @1m Diameter 6", (152mm) Weight 0.85Kg NBM-08 Supply Voltage 24-48Vd.c. Operating Current 55mA, Sound Output 102dB @1m Diameter 8", (2mm) Weight 2.1Kg IP Rating IP65 c/w gasket box. REAR VIEW FIXING POSITIONS 50mm 60mm 50mm

2 of 8 LFB-24 ELECTRONIC BANSHEE SOUNDER The Banshee Low Profile Sounder model LFB24 complies fully with the requirements of BS5839 Part 1 1980. It features a snap-on front, for ease of installation, it also has a rear cable entry for maximum flexibility. Measuring only six centimetres deep this Low Profile Banshee Sounder blends unobtrusively into background in to most installations. The LFB24 features Buzz, Fast Sweep, Slow Sweep and Continuous tones. Supply Voltage 24Vd.c. Operating Current 12-17mA Sound Output 68dB-1dB IP Rating I.P.45 Weight 250g VCT--NT BASE MOUNTED SOUNDER The VCT--NT conventional base or wall, (with cap - see description below) mounted electronic sounder has been designed for use with a standard Nittan STB-4 series base. The VCT--NT sounder base gives systems designers a new low profile design, whilst giving the installers reduced installation time with it s wide cable access and rising clamp terminals. Wiring from the fire alarm control panel s sounder circuit may wired directly into the VCT--NT base mounted sounder and then on to the next sounder. Supply Voltage 8-35V d.c. Current Consumption <12mA Sound Output 90 db @ 1m. Number of Tones 4 IP Rating IP43 92mm 61mm VCT--NT WALL MOUNTED VERSION SOUNDER C/W CAP The VCT--NT conventional base mounted electronic sounder can be easily converted to an attractively styled, wall mounted sounder by the addition of a red (VCT--CP-R) or white (VCT--CP-W) vector cover plate/cap which easily clips onto the front of the sounder. REAR VIEW FIXING POSITIONS 4 x 4.5mm slots on 62 and 48 centres Side and rear cable entry The VCT--NT sounder base gives systems designers a new low profile design, while giving the installers reduced installation time with it s wide cable access and rising clamp terminals. Wiring from the fire alarm control panel s sounder circuit may wired directly into the VCT--NT base or wall mounted sounder and then on to the next sounder. LFB-24 CONNECTIONS 0 Volts Continuous O'ride +12V d.c. +24V d.c. ACCESSORIES These vector plate/caps are used together with the VCT--NT base/wall mounted conventional sounder and must ordered together with this sounder. VCT--CP-W: Spare Vector Plate/cap (White) VCT--CP-R: Spare Vector Plate/cap (Red) Supply Voltage: 8-35V d.c. Current Consumption: <12mA Sound Output: 93 db @ 1m. Number of Tones: 4 IP Rating: IP43

3 of 8 VRS-1-R & VRS-1-W CONVENTIONAL BED HEAD MOUNTED SOUNDER The VRS-1 conventional bedhead mounted electronic sounder has been designed for use with conventional fire detection systems. The VRS-1 sounder is small in size but big on sound output. With it s low current consumption and high sound output the VRS-1 gives systems designers increased flexibility where a sounder with minimum visual impact is required. Wiring from the fire alarm control panel s sounder circuit may wired directly into the VRS-1 bedhead mounted sounder and then on the next sounder. The VRS-1 sounder is available in either white or red colour, suffix R or W. Part Numbers Description Sounders VRS-1-R Red bedhead sounder Computer No. FO6N*82426 VRS-1-W White bedhead sounder Computer No. FO6N*82427 Backbox's DBB-R Red Backbox for VRS-1-R Computer No. FO16N*81469 DBB-W White Backbox for VRS-1-W Computer No. FO16N*81468 Supply Voltage 8-35V d.c. Current Consumption <18mA Sound Output 101 db @ 1m. Number of Tones 4 IP Rating IP43 VCT--NT BASE MOUNTED SOUNDER SHOWN HERE WITH VECTOR PLATE/CAP VCT--NT BASE SOUNDER SHOWN HERE WITH STB-4 BASE 1 3 6 105mm Volume Control Tone Control 5 105 VRS-1-R RED CONVENTIONAL BED HEAD MOUNTED SOUNDER 87mm 105mm 40mm 87mm 105mm 42mm 32mm 87mm 34mm VRS-1 SOUNDER SINGLE GANG BACK BOX (Red or White)

4 of 8 VPR-SA2-R & VPR-SA2-W VIPER ELECTRONIC SOUNDER The Viper SA-2 sounder has been designed for applications where low current consumption relative to high sound output is required. With an operating frequency of 800-1000Hz each sounder provides sound within the frequency range specified in BS5839. Each sounder also has a wide operating voltage range of 8-35V d.c.. 105mm Different tones are available by selecting either Warble, Sweep, or Pips via the jumper fitted to the PCB. By using three wires, a second stage alarm may be switched so that the continuous tone will override the tone selected. The sounder casing material is ABS and is supplied in either red or white colours. 85mm 77mm Each sounder is supplied complete with its own mounting base which comes with marker points for drilling two M20 cable gland entries. PART NUMBERS Part Number Description VPR-SA2-R Red Viper Sounder Computer No. FO6N*82439 Part Number VPR-SA2-W Computer No. Description White Viper Sounder FO6N*82428 CONNECTION LAYOUT VOLUME Supply Voltage Range: 8-35Vd.c. Operating Current @ 26V d.c.: c.9ma Sound Output @ 1m: 1dB(a) IP Rating: IP65 Weight: 200grams Operating Frequency: 800-1000Hz Number of Tones: 4 Volume Control: -30dB(a) LINK/ JUMPER 1. (-) CONT 2. (-) CONT 3. (-) TONE 4. (-) TONE 5. (+) POS 6. (+) POS TONE SELECT SWEEP PIPS WARBLE

5 of 8 NCP-K(470) MANUAL CALL POINT The NCP-K470 manual call point operates by releasing a concealed microswitch when the glass is broken. The glass element is pre-scored to break easily under thumb pressure and thus no striker is required. The NCP-K470 is fitted with a 470 Ohm short circuit series monitor resistor. Each call point is supplied with a test key which, when inserted, simulates breaking the glass by allowing it to drop, causing actual operation of the micro-switch. The NCP-K470 is suitable for connection to both normally open and normally closed circuits. The switch type is a Single pole change-over switch with silver contacts. Supply Voltage 24Vd.c. Contact Single pole changeover MANUAL CALL POINT - NCP-K470-WP The NCP-K470-WP Weather proof, (IP67), manual call point operates by releasing a concealed microswitch when the glass is broken. The glass element is prescored to break easily under thumb pressure and thus no striker is required. The NCP-K470-WP is fitted with a 470 Ohm short circuit series monitor resistor. Each call point is supplied with a test key which, when inserted, simulates breaking the glass by allowing it to drop, causing actual operation of the micro-switch. Supply Voltage 24Vd.c. Contact Single pole changeover The maximum switching, resistive load is 8 Amps @ 30V d.c. and 3A @ 50V d.c.. 124mm The maximum switching, resistive load is 8 Amps @ 30V d.c. and 3A @ 50V d.c.. FIRE 86mm 60mm 86mm M20 CALL POINT CONNECTIONS 1 1a 1 1a 2 2a 3 52mm 3 3a NCP-K(470) 3a NCP-K470-WP

6 of 8 STA-R1 REMOTE INDICATOR LED The STA-R1 remote indicator LED is for use with NITTAN conventional and analogue addressable fire detection and alarm systems. 88mm It has been designed for fire alarms systems requiring local indication of an individual or group of fire detectors in alarm. The STA-R1 uses an ultra-bright LED with a wide area of illumination. The STA-R1 also may be used for other applications requiring a local visual indication such as process control, security and shutdown operations. FIRE DETECTOR OPERATED 88mm Supply Voltage 5V d.c. to 28V d.c. (Note: Current dependant on voltage, supply may be connected through resistor or direct to LED.) CONNECTIONS 1 2 3 + + - 8mm 20mm For conventional systems: Connect across load resistor (Terminals 1 & 3.) For analogue addressable systems: Connect across diode (Terminals 2 & 3.)

7 of 8 IB-R-SW2-24 XENON BEACON The XB range of xenon beacons have been designed to compliment other products in our range, both technically and aesthetically. Part IB-R-SW2-24, XENON BEACON (RED) Part IB-A-SW2-24, XENON BEACON (AMBER) Red or Amber Xenon beacon Flash Energy: 0.65J Output: 1 Watt Current Consumption: 45mA @ 24V d.c. Voltage Range: 20-30V d.c. Operating Temperature: -20 o C to +55 o C FL-RL-RD COMBINED XENON BEACON & SOUNDER The FL combined xenon beacon/sounder has been designed to compliment other products in our range, both technically and aesthetically. Part FL-RL-RD IP65, Red Zenon Beacon/Sounder, 3 Tones Output: 60 Flashes per Minute Current Consumption: 68mA (average) Voltage Range: 18-30V d.c. Sounder db: 101dB @ 1m Deep Base Version Operating Temperature: -10 o C to +55 o C

8 of 8 1992ROSH-DB, WEATHER PROOF SOUNDER The Roshni sounder has been designed to compliment other products in our range, both technically and aesthetically. TECHNICAL IP65, Weatherproof Sounder, 1-28 Tones Current Consumption: 18mA Voltage Range: 9-28V d.c. Sounder db: 100dB @ 1m. Deep Base Version Operating Temperature: -40 o C to +80 o C

Document Date : From world leaders in SENSOR TECHNOLOGY comes SENSORTEC... SENSORTEC-ACCESSORIES CONVENTIONAL REMOTE INDICATOR LED, BEACONS & SOUNDER/BEACONS NITTAN (UK) LTD. Hipley Street Old Woking Surrey England GU22 9LQ United Kingdom Quality System Certificate No. 041 Assessed to BS EN ISO 9002 Tel: +44 (0) 1483 769555 Fax: +44 (0) 1483 756686 E-mail: sales@nittan.co.uk Web Site: www.nittan.co.uk