SENSELEC INFRA-RED CONTROLS

Similar documents
SENSELEC INFRA-RED TAPS

AUTEAU SHOWER FITTINGS

The Safety Valve Specialist Thermostatic Shower Controls

Helping you understand your water usage

Shower Panels with a Thermostatic Sequential Control

WASHROOM SYSTEMS. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS

Taps, Shower & Flush Valve Range

The Safety Valve Specialist TMV2. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

Summer Works Scheme 2010

Water Regulations Tutorial # 7 Washroom

schools universities colleges academies

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

Euromixer Thermostatic Mixing Valves

Galway County Council. Comhairle Chontae na Gaillimhe

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

AUTOMATIC TAPS. Infrared Taps. The perfect hygiene and water saving enhancement

Did you know that you pay for water three times? 1 You pay to buy it 2 You pay to heat it 3 You pay to get rid of it

EHT10 Electric Hot Water Tap

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Movement Detector GJD 300

D8) Saving water and energy on water systems. W.G. van der Schee (1) Abstract. Keywords. 1 Introduction. (1)

Designs of domestic bathrooms, guidance and advice from

Leak Detection and Flood Prevention

Waterwise Rainwater Saving Guide

Description of the property and water systems:

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Helping you to understand your water use

the education & sports portfolio water management for SCHOOLS, COLLEGES AND RECREATION

the healthcare portfolio

TOP 100 WATER SAVING PRODUCTS

Sanitary & Hospital Equipment

Miscellaneous. TMV3 Mixing Valves. TMV3 Thermostatic Mixing Valves. Specifications. Temperature Readout. Features include:

Accessories. 4in1 DVS Thermostatic Mixing Valve. TMV3 Thermostatic Mixing Valves. Specifications

UK Distributors. Manufacturer and Distributor of Rainwater Harvesting Products UK-DIST-NP-01 1

REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE

022BWN0051 A GUIDE TO YOUR WATER METER 2014/2015

TECHNICAL DATA SHEET WORKING SPECIFICATION. Mains Power Supply: Wall Mounting. Online Connectivity. Operating Voltage. Data Feedback.

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

COMPACT LC urinal control. By SCHELL. integrated sensor for perfect hygiene.

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

House Drainage System. Building Utility & Services

SAFE ENSUITES Washroom products for Specialist Hospitals, Clinics, Care homes and custodial applications.

Performance on demand. Eliminate poor mains water pressure and flow problems. with mainsboost

Urban World Activity. Saving Water

AQUAFIT - the innovative single-lever mixer for safety and hygiene

shower panel specification manual 2008

Horne Engineering Ltd INSTALLATION, COMMISSIONING, OPERATING AND MAINTENANCE INSTRUCTIONS

Solutions brought to you by Hurlstones. Solutions brought to you by Hurlstones. shower panel specification manual 2012

Aquamin - Water Saving Aerator for Sink Tap of Kitchen- Dual Flow type with 360-degree swivel

Developer, new connection and infrastructure charges. 1 April 2015 to 31 March 2016

D-Tect 2 GJD300 Quad PIR Movement Detector

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

fixflow Fixed & Adjustable Temperatures WR-ZY-822D

Using water wisely HOME

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

The POWERTANK. Range A PACKAGED SOLUTION FOR BOOSTING WATER. by Pedrollo Distribution. powertank.co.uk

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

HOME SECURITY. 2 - Basic security

Condensation. 1

The importance of water for life

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

LS800S Intruder Alarm System. Engineering Manual

Single Induction Hob

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

SINKS AND HYGIENE EQUIPMENT

Installation, Operation, and Maintenance Manual

CHILDRENS TOILETS. Junior Series WC and Pan. Junior Series - Technical. Designer bathroom suites - miniaturized!

Thermomix Underfloor Heating Control Pack

HW3 Handwash Installation and Operating Instructions

THERMAL INTERFACE UNITS. Designed and manufactured in the UK. Designed for performance

The fastest to dry hands hygienically with HEPA filtered air.

GREEN TIPS SAVE MONEY, SAVE THE ENVIRONMENT

Owners Manual for the Rainmaster Water Recycling System

What is solarcache touch? How does it work? What can I see on the screen?

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Herz York Direct Heat Interface Unit

Greenleaf 600 Macerator Toilet Waste Pump

Low water use fittings: Measurement, opinion and policy

In-line thermostatic mixing valves

The problem with other hand dryers

Unique Washroom Solutions

APP Environmental Services P/L.

The Cleaning Professional s Skills Suite

FLOOD SERIES DATA SHEET

RAINWATER HARVESTING. An Overview of Rainharvesting Systems

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

CT range. of shower, bathroom and whole house pumps

Engelska English. Help us economise on. our precious water! Tips and information on saving water in the Municipality of Eksjö

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

USING YOUR PRESSURE SEWER SYSTEM

Introducing Low Voltage DC Grid Interconnects

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Master in Architecture. (Services in High Rise Buildings)

Outdoor living. Campsites Leisure parks Swimming pools Theme parks Holiday villages Harbours

Lift the lid and see the difference

Slimline, Energy Saving & Smart. It's the game changer!

Transcription:

SENSELEC INFRA-RED CONTROLS Electronic controls which help prevent water wastage and cross contamination in shared washroom and toilet facilities. Reliance Water Controls Ltd A Reliance Worldwide Company Worcester Road, Evesham, Worcestershire, WR11 4RA, UK UK - Freephone: 0800 389 5931 Freefax: 0800 389 5932 Outside UK - Tel: +44 (0) 1386 712400 Fax: +44 (0) 1386 712401 The Safety Valve Specialist Email: sales@rwc.co.uk

Water savings explained Increasing demand for water from limited resources has provoked awareness for the need to control wastage, not only to reduce the cost of our water supply and disposal but also to limit the effects that such water consumption has on the environment in which we live. To control this, it is imperative that we try to conserve as much water as we can whilst carrying out our daily routines of washing, cooking and bathing. Water efficiency and water conservation are quickly becoming a key feature of system design, particularly emphasised in the revision of part G of the building regulations, which stipulates a water usage limit of 125 litres per person per day. Reliance Water Controls offers a wide range of water saving devices which can be installed in either domestic or commercial properties to help limit daily water consumption. Use of such water saving devices can attract the award of points by the British Research Establishment Energy Assessment method (BRE-EAM): this means that this type of system complies with the environmental control for energy efficiency, which is part of the building regulations part 1 and considered by developers as an increasingly important issue when designing and planning a project. In commercial water systems, there is generally a higher risk of water wastage than in domestic systems, due to abuse and vandalism which can occur with water fittings in public places. Stories of vandals plugging up sinks, turning on taps full bore until water floods into hallways in schools, sport centres, cell blocks, etc are all too common. Water is regularly wasted in all houses and public areas. How much is wasted is hard to calculate however, consider this: A dripping tap could waste as much as 90 litres in a week Brushing your teeth with the tap running wastes almost 9 litres a minute Taking a five minute shower instead of a bath saves up to 400 litres a week If you multiply these numbers by the amount of households and commercial properties in the UK, it is clear that a huge amount of water could be saved each year. Whilst that does not mean to say that the public are to blame for all water wastage there are numerous underground water pipes which leak and waste water every day and which need to be tackled by water companies and the government it still represents a huge potential saving of unnecessary water use. With this in mind, organisations have set up schemes to help people benefit from using water efficient products: for example, the Water Technology List provides information on water-saving products which qualify for up-front tax relief. Products included on this list have been independently tested by Defra and the ECA to ensure that only items which meet with their performance criteria are accepted. Avoid cross contamination Infection from cross contamination can be a serious and health-threatening problem in shared facilities. The infra-red activation of Reliance s Senselec IR range allows the user to flush and wash without touching the controls or outlet at all. A no-touch, hands-free system of operation is of value in many environments, and particularly in healthcare premises, of course, where the risks and potential consequences of cross contamination are at their greatest. 2

Senselec IR Shower Controls A range of wall and panel mountable IR shower controls for use where water control and hygiene are of high concern. The sensor sends a micro-second long pulse to the solenoid valve when a presence is detected within the sensing field. The solenoid then opens and closes for a pre-programmed time period of 2 minutes (unless the user moves away in less time, then the shower will shut off). The solenoid valves are a magnetically latching type, which means that they use only a very small amount of energy each time they open and close. Product Range Battery Operated SENS 250 150 Senselec IR Shower Package, Cross Wall 150mm Fitting, Vortex Spray SENS 250 155 Senselec IR Shower Package, Cross Wall 150mm Fitting, Grid Spray SENS 250 160 Senselec IR Shower Package, Panel Mount 50mm Fitting, Vortex Spray SENS 250 165 Senselec IR Shower Package, Panel Mount 50mm Fitting, Grid Spray Stabilised Mains Power Supply SENS 251 150 Senselec IR Shower Package, Cross Wall 150mm Fitting, Vortex Spray SENS 251 155 Senselec IR Shower Package, Cross Wall 150mm Fitting, Grid Spray SENS 251 160 Senselec IR Shower Package, Panel Mount 50mm Fitting, Vortex Spray SENS 251 165 Senselec IR Shower Package, Panel Mount 50mm Fitting, Grid Spray Typical Installation 3

Typical Installation 1m 50mm panel 150mm cross wall Specifications Minimum operating pressure 0.5 bar (grid spray) Minimum operating pressure 1.0 bar (vortex) Maximum operating pressure 5.0 bar Maximum water temperature 70 C Power supply 6 Volts Typical consumption 28μA Maximum consumption 40μA Adjustable detection range 50mm - 250mm Factory detection setting 50mm Detection angle 8 Running time 2 mins Valve pulse time 20ms Length of supply wire 2.9 metres Length of solenoid wire 2.9 metres Flow regulator 8 lpm 1.1m Standards BSEN 15091 Approvals WRAS Solenoid Valve 0610050 Senselec IR WC Controls The Senselec IR WC controls are designed to supply a flush of water to a WC pan using a standard cistern with an electronic flush valve, with integral overflow, which is activated by breaking the sensing field of the IR beam. This WC control has a unique flush control system which ensures that water only enters the cistern when the flush valve is closed, so that an exact measure of water is used each time for flushing. If the WC is not used within a 12-hour period, the unit will automatically flush once to maintain hygiene. Activation by IR sensor helps to prevent cross contamination, as it allows hands-free operation; this is of particular value in healthcare premises, where a continuously high standard of hygiene is a top priority. Product range Stabilised Mains Power Supply SENS 251 170 Senselec IR WC Cross Wall 150mm SENS 251 175 Senselec IR WC Panel Mount 50mm 4

Typical Installation Specifications Minimum operating pressure 0.5 bar Maximum operating pressure 6.0 bar Power supply 6 Volts Typical consumption 28μA Maximum consumption 40μA Adjustable detection range 200mm - 600mm Factory detection setting 400mm Detection angle 8 Duration to activate 2 seconds Duration of flush 7 seconds Valve pulse time 20ms Length of supply wire 2 metres Length of solenoid wire 2 metres Standards BSEN 15091 Approvals WRAS Flushing Valve 0809329 50mm panel 150mm cross wall 150-300mm 5

Senselec IR Urinal Controls Senselec IR urinal controls are designed to supply a flush of water to a urinal using a solenoid valve and a type DC backflow preventer to comply with the water fittings and water regulations 1999 requirements regarding protection against class 5 backsyphonage risks. This configuration allows the installer to connect the solenoid valve feeding the urinal directly to the mains water supply, eliminating the need for a separate feed cistern or a separate dedicated water supply. The solenoid valve is activated by breaking the field of an infra red sensor. The field of the sensor must be broken for at least 5 seconds to activate, and once the user has moved away for at least 3 seconds the urinal automatically flushes for 5 seconds. If the urinal is not used within a 12 hour period the unit will automatically flush once to maintain hygiene. Product range Battery Operated SENS 200 060 Senselec IR Urinal Control, Cross Wall 150mm Fitting SENS 200 065 Senselec IR Urinal Control, Panel Mount 50mm Fitting Stabilised Mains Power Supply SENS 201 060 Senselec IR Urinal Control, Cross Wall 150mm Fitting SENS 201 065 Senselec IR Urinal Control, Panel Mount 50mm Fitting Typical Installation 6

Typical Installation 150mm 50mm panel 150mm cross wall 300mm Min 22mm Pipe Specifications Minimum operating pressure 0.5 bar Maximum operating pressure 5.0 bar Maximum water temperature 70 C Flow regulator 6 lpm Power supply 6 Volts Typical consumption 28μA Maximum consumption 40μA Adjustable detection range 200mm - 600mm Factory detection setting 400mm Detection angle 8 Duration to activate 2 seconds Duration of flush 7 seconds Valve pulse time 20ms Length of supply wire 800mm Length of solenoid wire 800mm Standards BSEN 15091 Approvals WRAS Solenoid Valve 0610050 WRAS DC Backflow Preventer 0812303 Senselec Ceiling Mounted Urinal Controllers Senselec ceiling mounted urinal controls are controlled by a PIR (Passive Infra-Red) sensor mounted in/on the ceiling, which is used to fill a urinal cistern. It has been designed to reduce the amount of wastage that can occur when a urinal is in constant use. The PIR sensor works by sensing the movement of a body. After the user has been detected, the PIR will then wait 30 seconds and fills the cistern with a set amount of water. As it is feeding a cistern it can be used for single or multiple urinals. After 6 hours of inactivity the device will enter hygiene mode and allow a set amount of water into the cistern: this keeps the traps wet and reduces odour problems. Product range Stabilised Mains Power Supply SENS 200 070 Surface Ceiling Mounted Passive IR Urinal Sensor SENS 200 075 Recessed Ceiling Mounted Passive IR Urinal Sensor 7

Typical Installation - Surface Mounted 12V TRANSFORMER CISTERN PIR SENSOR SOLENOID VALVE CEILING VOID STRAINER Specifications Minimum operating pressure 0.5 bar Maximum operating pressure 10.0 bar Maximum water temperature 75 C Power supply 12 Volts Typical consumption 900mA Sensor detection distance 6 metres Detection angle 35 Duration to activate 1-20 seconds Valve pulse time 20ms Length of supply wire 1.9 metres Length of solenoid wire 2.9 metres URINALS Standards BSEN 15091 Approvals WRAS Solenoid Valve 0610050 Typical Installation - Recessed CEILING VOID 12V TRANSFORMER SOLENOID VALVE STRAINER PIR SENSOR CISTERN URINALS 8

Senselec Systemguard The Senselec Systemguard is designed to protect washroom facilities in commercial environments when unused for extended periods. The infra-red control system will shut down a solenoid valve or valves on the supply pipe to the washroom if no movement is detected within the sensing area for a pre-determined time period. In this way any leakage from a terminal fitting will result in a minimal waste of water. Product range Stabilised Mains Power Supply SENS 200 090 Recessed Ceiling Mounted System Shut Down Pack ZSOL500010 ½" fbsp 12V Normally Closed Solenoid Valve ZSOL500015 ¾" fbsp 12V Normally Closed Solenoid Valve ZSOL500020 1" fbsp 12V Normally Closed Solenoid Valve Specifications Minimum operating pressure 0.5 bar Maximum operating pressure 10.0 bar Maximum water temperature 75 C Power supply 12 Volts Typical consumption 900mA Sensor detection distance 6 metres Detection angle width 45.5 Detection angle length 42 Valve pulse time 20ms Length of supply wire 1.9 metres Length of solenoid wire 2.9 metres Adjustable detection time range 6-60 minutes Typical Installation IR SENSOR CONTROL BOX Standards BSEN 15091 Approvals WRAS Solenoid Valve 0610054 SOLENOIDS COLD HOT RETURN 9

SENS 250 000 - Senselec Wired Remote Control The remote control gives the installer the ability to accurately set up the product and to monitor usage. Functions include: monitoring the number of operations completed by the tap or control, the setting of the detection distance, the comfort interval, security settings, the hygiene flush interval and many more. The remote control is powered by a replaceable 9 volt battery. To use the remote control simply disconnect the cable connections from the solenoid valve and re-connect them to the terminals on top of the remote control. Rouge Red Noir Black Val Can ON When the remote control is turned on, four core menus are presented which allow the user to select language, monitoring functions, sensor type and parameter. Having selected one of the core menus, sub menus are presented that can be selected to monitor the operation of the tap or control, or to change the operation parameters. One of the parameters that can be changed is that of the hygiene flush which is normally in the inactive mode for the standard control set up but can be set to be active at a 6, 12 or 24 hourly interval with the flow set for any duration between 10 to 180 seconds. In addition to this the detection range, comfort timeout and safety timeout can also be set. Note: - Wired remote control is only suitable for showers, wall mounted urinals and WC controls. 10

Infra-Red Spares ZSOL500001 15mm pushfit magnetic 6V Solenoid Valve ZSOL500005 15mm pushfit normally closed 12V Solenoid Valve ZSOL500010 ½" fbsp normally closed 12V Solenoid Valve ZSOL500015 ¾" fbsp normally closed 12V Solenoid Valve ZSOL500020 1" fbsp normally closed 12V Solenoid Valve ZENS252005 IR Sensor for Urinal Control (not Ceiling version) ZENS252010 IR Sensor for Shower ZENS252020 IR Sensor for WC Control ZENS252040 Systemguard PIR Sensor ZENS252030 Surface Mounted Urinal PIR Sensor ZENS252035 Recessed Urinal PIR Sensor ZRAN252005 6V Transformer ZRAN252010 12V Transformer ZBAT252005 Spare Battery ZBAT252001 Battery Box ZCAB500030 30mm Connection Cable for linking two or more Solenoids ZCAB500035 2900mm Connection Cable for linking two or more Solenoids 11

SENSELEC INFRA-RED CONTROLS Reliance Water Controls Ltd A Reliance Worldwide Company Worcester Road, Evesham, Worcestershire, WR11 4RA, UK UK - Freephone: 0800 389 5931 Freefax: 0800 389 5932 Outside UK - Tel: +44 (0) 1386 712400 Fax: +44 (0) 1386 712401 Email: sales@rwc.co.uk Reliance has prepared the content of this document carefully but disclaims all warranties, express or implied, as to the accuracy of the information contained herein. Reliance reserves the right to make changes to the product and the information contained in this document at any time. SENSIRCONT - 001-09/09 Reliance Water Controls Ltd 2009 The Safety Valve Specialist