Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Similar documents
Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

IEC Lighting Contactor Specifications

SPECIFICATIONS. Contents List

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

LMV Series W Low Profile - Medium Base

NEMA Manual. Starters. NEMA Manual Starters Contents

Brasch Hazardous Location Unit Heaters

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

CIRCUIT BREAKER UNIT ENCLOSURES 10,000/25,000 AMPERES INTERRUPTING CAPACITY. UPC Code. Catalog Number

EXH Series Explosionproof Electric Air Heaters

PANELBOARD PROTECTION ON A GLOBAL SCALE

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Applications. Standard Materials

BULLETIN 600 SINGLE PHASE

Arrow Hart hospital grade self-test GFCI receptacles

Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS APPLICATIONS

EJB Custom-Built Control Panels

Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

Molded Case Circuit Breakers, Bulletin 140G

Powers Controls Low Temperature Detection Thermostat

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

Table 500-3(d) Identification Numbers. Maximum Identification

DMV Series W For Combustible Dusts

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Type UB-2502A and UB-3002A Forced-Air Heater

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Description. Construction

VAPORGARD Incandescent Luminaires

KUH. Horizontal Unit Heater. Applications. Description

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Arrow Hart specification grade GFCI receptacles

EVLPF Series Compact Fluorescent

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater

Installation, Operation and

Gfci Self Test Duplex 20A 125V WH

Ultrasonic Switches. Features & Benefits

FDJ SERIES Jockey Pump Controllers Features

Powers TM Controls ET 134 Line Voltage Room Thermostats

FDF Foam Pump Controllers Features

Vibratone Horns. Models 350 and 450

Powers Controls ET 134 Low Temperature Detection Thermostat

Ultrasonic Point Level Switches

ULTRA-SAFE Explosion-proof Duct Heaters

N2MVF Series Compact Fluorescent

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

DIESEL Engine Fire Pump Controllers Features

Description. Applications

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

UTILITY LIGHT INTRODUCTION

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

Model D12-IR. Digital Gas Transmitter...

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

A. Product Data: Include rated capacities, furnished specialties and accessories.

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

ADF/ADFH 300 and 500

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Bulletin 855T 70 mm Control Tower Stack Lights

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

AF/GF dual-purpose receptacles

Two-Position Electric Duplex Room Thermostats

Heavy Industrial/Marine MaxGard

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ULTRA-SAFE Explosion-proof Duct Heaters

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

SIL 2. Ultima X Series Gas Monitors CERTIFIED

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Quality. Trust. Value. Safety.

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

DIESEL Engine Fire Pump Controllers Features

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

MaxGard. Interconnection Systems. Durability. Performance. Safety

Temperature, Mechanical

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

KEENER GRINDER PUMPS

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

INSTALLATION INSTRUCTIONS

UHD Heavy Duty Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

SECTION ENCLOSED CONTROLLERS

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Transcription:

Contender Series Factory Sealed Manual Motor Starters and Contactors Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Applications Manual motor starters are available to meet any plant installation requirement. They may be used to install a variety of electrical wiring devices and comes complete with covers and dead-end or feed-thru hub arrangements. Available with or without the heater. Complete units are ideal for manual starting of small Vac or Vdc motors in locations made hazardous by the presence of flammable vapors, gases or combustible dust. Features Easily readable operator handle with provisions for padlocking in the ON or OFF position. Cast in hubs. Interchangeable heater units. Standard Materials Body and cover: malleable iron Sealing chamber: copperfree (4/10 of 1% max.) aluminum Operating handle: nylon Standard Finishes Body and cover: gray epoxy powder coat Options For Aluminum Backbox and Cover add suffix -SA. Starters are furnished with one interchangeable heater. Select heater number from heater selection table and add appropriate suffix to catalog number. For example, a complete catalog number with Allen-Bradley motor starter and Allen-Bradley 0-17 amp heater: EPS2199-P1. NEC/CEC Certifications and Compliances UL Standards: UL 508, UL 698, UL 1203, CSA Standards: CSA C22.2 No. 14-M, C22.2 No. 25, C22.2 No. 30 culus Listed: E81751, E76550 1-Gang 2-Gang 562

Contender Series Factory Sealed Manual Motor Starters and Contactors Factory Sealed Manual Motor Starters with Cutler-Hammer Devices Poles 1 2 Catalog Number 1-Gang Catalog Number 2-Gang Catalog Number Cover/Chamber/Device EDS11101 EDSC11101 3/4 EDSK-1MSW EDS21101 EDSC21101 EDS22101 EDSC22101 1 EDS31101 EDSC31101 EDS32101 EDSC32101 EDS11102 EDSC11102 3/4 EDSK-2MSW EDS21102 EDSC21102 EDS22102 EDSC22102 1 EDS31102 EDSC31102 EDS32102 EDSC32102 Manual Motor Starter Horsepower Ratings Poles 120-240 Vac 32 Vdc 120 Vdc 240 Vdc Cutler-Hammer Catalog Number 1 1 HP 1/4 HP 1/4 HP MST01 2 1 HP 1/4 HP 1 HP 1 HP MST02 Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Factory Sealed Motor Rated Switches No Heater Options Poles 2 3 Catalog Number 1-Gang Catalog Number 2-Gang Catalog Number Cover/Chamber/Device EDS11MC2 EDSC11MC2 3/4 EDSK-MC2 EDS21MC2 EDSC21MC2 EDS22MC2 EDSC22MC2 1 EDS31MC2 EDSC31MC2 EDS32MC2 EDSC32MC2 EDS11MC3 EDSC11MC3 3/4 EDSK-MC3 EDS21MC3 EDSC21MC3 EDS22MC3 EDSC22MC3 1 EDS31MC3 EDSC31MC3 EDS32MC3 EDSC32MC3 Manual Contactor Switch Ratings Poles Description Rating 2 Square D Class 2510, Type KO-1 3 Arrow-Hart AH7810-UD 30 Amp, 250 Vac/Vdc; 20 Amp, 600 Vac; 1 HP, 115 Vac; 2 HP, 230 Vac; 3 HP, 460-575 Vac 30 Amp, 600 Vac; 3 HP, 120 Vac; 7- HP, 240 Vac; 15 HP, 480 Vac; 15 HP 600 Vac Ordering Instructions: Starters and starter cover assemblies are furnished with one interchangeable heater. Select heater number from heater selection table and add appropriate suffix to catalog number. For example, a complete catalog number with Cutler-Hammer motor starter and Cutler-Hammer heater: EDS11101-W1. Cutler-Hammer is a registered trademark of Eaton Corporation. Available in aluminum add suffix -SA. 563

Contender Series Factory Sealed Manual Motor Starters Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS Factory Sealed Manual Motor Starters with Allen-Bradley 600 Devices Poles 1 2 Catalog Number 1-Gang Catalog Number 2-Gang Catalog Number Cover/Chamber/Device EDS1199 EDSC1199 3/4 EDSK-1MSAB EDS2199 EDSC2199 EDS2299 EDSC2299 1 EDS3199 EDSC3199 EDS3299 EDSC3299 EDS11100 EDSC11100 3/4 EDSK-2MSAB EDS21100 EDSC21100 EDS22100 EDSC22100 1 EDS31100 EDSC31100 EDS32100 EDSC32100 Manual Motor Starter Horsepower Ratings Poles 120-240 Vac 32 Vdc 120 Vdc 240 Vdc Allen-Bradley Catalog Number 1 1 HP Bulletin 600 2 1 HP 3/4 HP 3/4 HP Bulletin 600 Ordering Instructions: Starters are furnished with one interchangeable heater. Select heater number from heater selection table and add appropriate suffix to catalog number. For example, a complete catalog number with an Allen-Bradley motor starter and an Allen-Bradley heater: EDS1199-P5. Allen-Bradley is a registered trademark of Rockwell Automation. Available in aluminum; add suffix -SA. 564

Contender Series Factory Sealed Manual Motor Starter and Contactor Heaters Allen-Bradley and Cutler-Hammer heaters and starters are not interchangeable with each other. The Full Load Motor Current listed in the tables below are ratings which determine the proper heat element that should be used with the EDS Series starters. Refer to motor nameplate for its full load motor current. It is our recommendation that for normal conditions the heater element selected should have a capacity of 20 to 25% greater than the full load current of the motor. This applies to standard +40 C (+104 F) temperature rise motors. For +50 C (+122 F) rise motors, a heater not greater than 115% full load current should be selected. Allen-Bradley Full Load Motor Current (Amp) Add Suffix Contender/EDS However, due to the difference between full load motor currents of various motor manufacturers of the same size motors, the above information is approximate. If selection of heater element is uncertain as might be in the case of a motor subject to frequent starting and intermittent load, it is advisable to contact the starter manufacturer or his local representative giving full particulars, such as motor horsepower, voltage, phase cycles, name or manufacturer or pertinent data that may aid in the selection of the proper heater element. Cutler-Hammer Full Load Motor Current (Amp) Heater Rating (Amp) Add Suffix Contender 0.17 P1 0.40-0.43 0.50 W1 0.21 P2 0.44-0.48 0.55 W2 0.25 P3 0.49-0.53 0.61 W3 0.32 P4 0.54-0.58 0.67 W4 0.39 P5 0.59-0.64 0.74 W5 0.46 P6 0.65-0.71 0.81 W6 0.57 P7 0.72-0.78 0.89 W7 0.71 P8 0.79-0.87 0.98 W8 0.79 P9 0.88-0.95 1.10 W9 0.87 P10 0.96-1.03 1.20 W10 0.98 P11 1.04-1.15 1.30 W11 1.08 P12 1.16-1.27 1.45 W12 1.19 P13 1.28-1.35 1.60 W13 1.30 P14 1.36-1.51 1.70 W14 1.43 P15 1.52-1.67 1.90 W15 1.58 P16 1.68-1.83 2.10 W16 1.75 P17 1.84-1.99 2.30 W17 1.88 P18 2.00-2.23 2.50 W18 2.13 P19 2.24-2.47 2.80 W19 2.40 P20 2.48-2.71 3.10 W20 2.58 P21 2.72-2.95 3.40 W21 2.92 P22 2.96-3.27 3.70 W22 3.09 P23 3.28-3.59 4.10 W23 3.32 P24 3.60-3.99 4.50 W24 3.77 P25 4.00-4.39 5.00 W25 4.16 P26 4.40-4.79 5.50 W26 4.51 P27 4.80-5.26 6.00 W27 4.93 P28 5.27-5.83 6.60 W28 5.43 P29 5.84-6.39 7.30 W29 6.03 P30 6.40-7.03 8.00 W30 6.83 P31 7.07-7.74 8.80 W31 7.72 P32 7.75-8.46 9.70 W32 8.24 P33 8.47-9.35 10.60 W33 8.90 P34 9.36-10.30 11.70 W34 9.60 P35 10.31-11.35 12.90 W35 10.80 P36 11.36-12.47 14.20 W36 12.00 P37 12.48-13.67 15.60 W37 13.50 P38 13.68-15.12 17.10 W38 15.20 P39 15.13-16.00 18.60 W39 Cutler-Hammer is a registered trademark of Eaton Corporation. Allen-Bradley is a registered trademark of Rockwell Automation. Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS 565

Contender Series Factory Sealed Manual Motor Starter Mounting Bodies Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS 1-Gang 2-Gang Tandem Type Catalog Number Malleable Iron Aluminum EDS171 EDS171-SA 3/4 EDS271 EDS271-SA 1 EDS371 EDS371-SA EDSC171 EDSC171-SA 3/4 EDSC271 EDSC271-SA 1 EDSC371 EDSC371-SA EDS172 EDS172-SA 3/4 EDS272 EDS272-SA 1 EDS372 EDS372-SA EDSC172 EDSC172-SA 3/4 EDSC272 EDSC272-SA 1 EDSC372 EDSC372-SA EDS177 EDS177-SA 3/4 EDS277 EDS277-SA 1 EDS377 EDS377-SA EDSC177 EDSC177-SA 3/4 EDSC277 EDSC277-SA 1 EDSC377 EDSC377-SA For tandem bodies, external seals must be installed within 1.5 meters (5 feet) of each conduit entrance for Class I, Groups C and D. 566

Contender Series Factory Sealed Manual Motor Starter and Contactor Dimensions in Millimeters 1-Gang and 2-Gang 8.7 mm (0.3438 ) Dia. (2) Mtg. Holes B A 5.31 / 134.8 mm 66.8 mm (2.63 ) 94.4 mm (3.72 ) 6.3 mm x 28.5 mm (0.25 x 1.125 ) (4) Screws 149.3 mm (5.88 ) 8.7 mm (0.3438 ) Dia. (2) Mtg. Holes 134.8 mm (5.31 ) C 134.8 mm (5.31 ) 8.7 mm (0.3438 ) Dia. (2) Mtg. Holes 33.2 mm (1.31 ) 188.2 mm (7.41 ) 1-Gang Front Single/Two Gang Side 2-Gang Front 6.3 mm x 28.5 mm (0.25 x 1.125 ) (8) Screws 149.3 mm (5.88 ) Dimensions in Millimeters A B C 153.9 (6.06) 172.9 (6.81) 19.0 (0.75) 3/4 153.9 (6.06) 172.9 (6.81) 22.3 (0.88) 1 156.7 (6.17) 178.5 (7.03) 25.4 (1.00) Controls NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION MOTOR STARTERS 567