Operating Instructions Three Phase Identification System TM

Similar documents
LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

RK CO 2 Transmitter Operator s Manual

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

CT-7 Series Toxic Gas Transmitter Operator s Manual

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

RK/ RK Oxygen Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

RK Hydrogen Sulfide Transmitter Operator s Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual

Combustible Gas Sample-Draw Detector Operator s Manual

Long Range Radio Alarm Transmitter

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

RK-CH4-4 Combustible Gas Transmitter Operator s Manual

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

RK-02 Multi Point Detector Operator s Manual

User's Guide. Pinless Moisture Meter. Model MO257

Controllers. Instruction Manual WARNING

TrueClean ToteCleaner

Spy model 673 wet sponge holiday detector ope rati ng instructions

GAS MONITOR Model Model

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

WATCHMAN AREA VOLTAGE DETECTOR

Instruction Manual WARNING

RK-05 Carbon Monoxide Detector Operator s Manual

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

VA301C CONTROLLER WITH BACnet OPTION

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

RK Multi Point Detector Operator s Manual

3M Overhead Ionizing Blower 991A

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

! "! # Please read these installation and operating instructions completely and carefully before starting.

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

High Temperature InfraRed Thermometer with Laser Pointer

V-WATCH PERSONAL VOLTAGE DETECTOR

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

Long Range Radio Alarm Transmitter

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

FW-KP WIRELESS KEYPAD

Model: EF34. Owner's Guide & Installation Manual

COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

USER MANUAL CR-V01K. All-in-one cleaning & air purifying robot. SERVICE HOTLINE: Or visit :

RK Combustible Gas Transmitter Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

MN908 No. 282C Replaces 282B LB7013

Dual Laser InfraRed (IR) Thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RK/ RK Oxygen Detector Operator s Manual

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Operator s Manual. The Quietek

LoveGo. Portable oxygen concentrator Your Second Doctor. Table of contents. Lovego, let s go along with love. DO what you want to do

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Installation and Operating Instructions

NT DUAL CHANNEL DISPLAY. User Guide

THERMAX Efficiency Monitor

Remote Vehicle Control System

Remote Vehicle Control System. Security and Convenience System

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

RK Carbon Monoxide Transmitter Operator s Manual

Industrial Vacuums, Inc

Beacon 410A Gas Monitor Operator s Manual

SPRINGHILL 44 CEILING FAN

RK-03 Hydrogen Detector Operator s Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

InstructIon Manual KrEs EQuIPMEnt stands

52 STRATHMERE CEILING FAN

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

RK/ RK Combustible Gas Detector Operator s Manual

RK-05 Carbon Monoxide Transmitter Operator s Manual

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

USER S GUIDE SPARE PARTS SPARE PARTS FOR SOS-LIFE EARTHQUAKE/EMERGENCY ALARM. SOS-LIFE earthquake/emergency alarm unit

RAM3 Remote Alarm Module

Digital Heat Block User Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Effective May 2017 Supersedes October 1998 (S )

Macurco HD-11 Hydrogen Gas Detector

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

USER MANUAL 10 YEAR LIFE SMOKE ALARM

Eurys Series. User Guide. Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm)

RK / RK Methane Detector Operator s Manual

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

169MHz Telecare Devices Heat Detector

Transcription:

Operating Instructions Three Phase Identification System TM 1

CAUTION The equipment covered in these operating instructions should be used by qualified employees trained in and familiar with the safety related work practices, safety rules and other safety requirements associated with this type of equipment. These instructions are not intended as a substitute for adequate training, nor do they cover all details or situations which could be encountered in relation to the operation of this type of equipment. WARNING Use appropriate length live line tools for the voltage being worked and maintain minimum approach distances as outlined in OSHA 1910.269, Table E-6. Do not let live line tool fittings become grounded in any way. This may result in equipment damage, personal injury and/or death. Do not hold meter probe with bare or insulated hand, minimum live line tool length is 2 ft 1in. Meter housing and any attachments shall be considered non-insulating. Meter should NOT be used as an insulating tool. The high voltage probe(s) shall be wiped clean prior to each use with a silicone impregnated cloth and kept clean and free of contaminates to prevent tracking on the outside of the probe, which could affect accuracy of the meter and/or failure, resulting in equipment damage, personal injury and/or death. NOTICE Before operating this equipment, read, understand and follow all instructions contained in this manual. Keep instructions with equipment. DESIGN and FUNCTION The 3 phase ID machine is designed to identify up to 3 shielded conductors before and after the center conductor is exposed while maintaining single or multiple ground connections. This unique tool features a transmitter module that produces 3 different signals and a passive receiver consisting of a current transformer with an audible/visual handheld display to indicate the correct phase conductors. This device will significantly reduce previously needed coordination resulting in time savings and eliminates safety concerns by maintaining ground connections during the entire process. The transmitter module is powered by two Milwaukee lithium ion M18 batteries and incorporates cam lock connectors to quickly interface different attachments such as C style, ball socket, and alligator clamps. 2

Operation for identifying shielded conductors before cut is made 1.1 Isolate conductor(s) to be tested at all possible connections, test for absence of voltage and apply grounds at all location(s). 1.2 Install charged and tested batteries into sender. 1.3 Remove grounds at location of sender. 1.4 Install and attach respective leads to all phase conductors. 1.5 Red on Phase 1A. 1.6 Yellow on Phase 2B. 1.7 Blue on Phase 3C. 1.8 Turn machine on. 1.9 Two sets of LED s should indicate continuity (solid) and applied signal (blinking). 1.10 Attach receiver clamp on to horn box, clamp around each phase cable to be identified. The clamp must be oriented with the arrow towards GROUND or away from the sender. 1.11 Listen for beeping that will indicate phase. If no audible signal is detected rotate sensitivity knob forward until you can hear the signal. The following repeating patterns will indicate phase. 1.12 Phase 1A: Beep Off Beep 1.13 Phase 2B: Beep, Beep Off Beep, Beep 1.14 Phase 3C: Beep, Beep, Beep Off Beep, Beep, Beep Operation for identifying shielded conductors after cut is made 1.1 Attach receiver clamp on to horn box, clamp around each phase cable to be identified. The clamp must be oriented with the arrow towards GROUND or away from the sender. 1.2 Listen for beeping that will indicate phase. If no audible signal is detected rotate sensitivity knob forward until you can hear the signal. The following repeating patterns will indicate phase. 1.3 Phase 1A: Beep Off Beep 1.4 Phase 2B: Beep, Beep Off Beep, Beep 1.5 Phase 3C: Beep, Beep, Beep Off Beep, Beep, Beep 1.6 Mark identified phases. 3

Parts and Accessories TPIDT 3 PHASE ID TRANSMITTER BOX CT110 BIERER CLAMP ON CT TPIDAVR TPID AUDIO/VISUAL RECEIVER M18B-2 MILWAKEE BATTERY, SET OF 2 M18B MILWAKEE BATTERY, SINGLE M18C CHARGER, M18B BLW LARGE CASE W/O FOAM TPIDBLW LARGE CASE WITH FOAM TPIDBSCK CABLE KIT, BALL SOCKET CLAMP TPIDTP75K CABLE KIT, 3/4" C-CLAMP TPIDACK CABLE KIT, ALLIGATOR CLAMP TPID115YKK CABLE KIT, 15KV ELBOW, YELLOW, W/O GREEN R1015M48BSC CABLE, 8' #4, RED CAM TO BALL SOCKET CLAMP Y1015M48BSC CABLE, 8' #4, YELLOW CAM TO BALL SOCKET CLAMP B1015M48BSC CABLE, 8' #4, BLUE CAM TO BALL SOCKET CLAMP G1015M48BSC CABLE, 8' #4, GREEN CAM TO BALL SOCKET CLAMP R1015M48115YK CABLE, 8' #4, RED CAM TO 15KV ELBOW Y1015M48115YK CABLE, 8' #4, YELLOW CAM TO 15KV ELBOW B1015M48115YK CABLE, 8' #4, BLUE CAM TO 15KV ELBOW R1015M48AC CABLE, 8' #4, RED CAM TO ALLIGATOR CLAMP Y1015M48AC CABLE, 8' #4, YELLOW CAM TO ALLIGATOR CLAMP B1015M48AC CABLE, 8' #4, BLUE CAM TO ALLIGATOR CLAMP G1015M48AC CABLE, 8' #4, GREEN CAM TO ALLIGATOR CLAMP R1015M48TP75 CABLE, 8' #4, RED CAM TO 3/4" C-CLAMP Y1015M48TP75 CABLE, 8' #4, YELLOW CAM TO 3/4" C-CLAMP B1015M48TP75 CABLE, 8' #4, BLUE CAM TO 3/4" C-CLAMP G1015M48TP75 CABLE, 8' #4, GREEN CAM TO 3/4" C-CLAMP Technical & Service Bierer & Associates Inc. Manufacturing & Repair 10730 Farrow Rd. Blythewood SC 29016 Tel: (803) 786-4839 Fax: (803) 786-5457 bierermeters.com 4

Operating Instructions ACDM Cable Identifier Receiver 1

CAUTION The equipment covered in these operating instructions should be used by qualified employees, trained in and familiar with the safety-related work practices, safety rules and other safety requirements associated with the use of this type of equipment. These instructions are not intended as a substitute for adequate training, nor do they cover all details or situations which could be encountered in relation to the operation of this type of equipment. NOTICE Before operating this equipment, read, understand and follow all instructions contained in this manual. Keep instructions with equipment. DANGER DO NOT ATTACH TO ENERGIZED SOURCE. WARNING Always install and remove the CT with the unit off. Never clamp CT around a conductor until connected to unit. Limitation of Warranty and Liability Bierer & Associates Inc. warrants this product to be free from defects in workmanship and material, under normal use and service conditions for a period of one year from date of shipment. Due to continuous product improvement and development, Bierer & Associates Inc. reserves the right to modify product designs and specifications without notice. It is impossible to eliminate all risks associated with the use of high voltage electrical devices including this device. Risks of serious injury or death are inherent in working around energized electrical systems. Such risks include but are not limited to variations of electrical systems and equipment, manner of use or applications, weather and environmental conditions, operator mentality, and other unknown factors that are beyond the control of Bierer & Associates Inc. Bierer & Associates Inc. does not express or imply to be an insurer of these risks, and by purchasing or using this product you AGREE TO ACCEPT THESE RISKS. IN NO EVENT SHALL Bierer & Associates Inc. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT. 2

Design and Function The ACDM Cable Identifier Receiver is an analog passive receiver for the DCI-50-CT, the DCI-100-CT, and the TPID transmitter. The kit includes a ACDM receiver and a B110 current clamp. The unit is designed to show a needle deflection in response to a dc pulse on the line in the direction the pulse is moving. The display is a centered needle display with a red and green area on either side, a green deflection indicates pulse moving in the same direction as the red arrow on the CT and a red deflection means the pulse is moving in the opposite direction. ACDM SET-UP AND TEST 1. Using the instructions provided with the device being used to test with, set-up and install transmitter device. 2. Plug the CT into the unit. WARNING Always install and remove the CT before use. Never clamp CT around a conductor until connected to unit. 3. Place CT around conductor being tested with the red arrow pointing to the grounded side. 4. The needle will deflect if the transmit signal is present. 5. A green deflection indicates it is the correct line in the correct direction. 6. A red deflection is either the return or the correct conductor with the ct installed backwards. Note: typically, the return signal on a single conductor will be weaker than the primary signal as the signal is split amongst all the grounds 7. Once the correct cable has been identified. You can remove the CT from the unit. 8. Once the ct is not around the conductor any longer, you can remove the ct from the unit and return to its carry case. 3

NOTES Technical & Service Bierer & Associates Inc. Manufacturing & Repair 10730 Farrow Rd. Blythewood, SC 29016 Tel: (803) 786-4839 Fax: (803) 786-5457 www.bierermeters.com 4