HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

Similar documents
TSEK VHR EC HEAT RECOVERY UNITS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

Heat Recovery Units. Heat Recovery Units

TEVHR. Heat Recovery Ventilators

TEVHR. Heat Recovery Ventilator

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

TEVHR. Heat Recovery Ventilators

INSTALLATION OPERATION MAINTENANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS

TopMaster Air Handling unit. Technical data

HRV Enthalpy. Catalogue

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Highly Efficient,Powerful Heating and Cooling.

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

KOMFORT EC DB Suspended heat recovery air handling units

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

AIR HANDLING UNITS MANDÍK

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Roof top SPACE RPC 450Z R407C M011

Heat and energy recovery ventilators

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

The Sentinel Kinetic Horizontal Range

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Topvex SR03, SR04, SR06 Compact Air Handling Unit

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Roof top SPACE RPC 315Z R407C MA00

HEAT RECOVERY DEVICES

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Series VENTS VUT R WH ЕС

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

TopMaster Air Handling unit. Installation instructions

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

The ultimate in air handling units: directly and indirectly fired

TECHNICAL SPECIFICATION

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

The ultimate in air handling units: directly and indirectly fired

RE-PR3-E-27 3-Phase Panel Mount 27kW

COMPACT AIR HANDLING UNIT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Duct air-handling units

CONTENT: VEX308 Decentralised ventilation VEX308

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TopMaster Air Handling Unit

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

AHU Plus. DX Air Handling Units

Heat Recovery Unit HERU. web-version

Lossnay RVX Fresh Series Air Ventilation

RIS V. AHU with heat recovery. exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices.

Lo-Carbon Sentinel Kinetic Horizontal

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

VERSO Air Handling Units

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

The ultimate in air handling units: directly and indirectly fired

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

VEX280H with rotary heat exchanger and EXact control system

VEX250H with rotary heat exchanger and EXact control system

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Domestic & Commercial Fans

Auxiliary Equipment and Accessories

50TM TFF COMBINATION HEATING/COOLING UNITS

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Air to Air Heat Exchanger

50TM COMBINATION HEATING/COOLING UNITS

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

CLIMASTER ZCF AIR HANDLING UNITS

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Heat recovery unit RDKS

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Small Room Heat Recovery Ventilation

The ultimate in air handling units: directly and indirectly fired

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

Transcription:

HEAT RECOVERY UNITS TSEK Mech-Elec,, Hawthorn Road, Western Ind. Est., Dublin Tel: +-- 88 E-Mail: info@mech-elec.ie Mech-Elec UK, Unit, Bretts Farm, Romford Road, Aveley, Essex, RM XD. Tel: +--879 E-Mail: info@mech-elec.net

GENERAL INFORMATION Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality. units provide the facilities of air-conditioning applications (residential, commercial and industrial areas) by using plate type exchangers, recovering heat from air to air. The heat is effectively transferred from warm to cold air by the exchangers with high conductivity, efficiency and performance. 7 standard models, with TSEK certification, CE marked and GOST-R certification in compliance with applicable directives, High efficient, direct driven AC Fans with low noise level, Proper ventilation with speed fans controlled separately, The compact design provides easy installation and maintenance, Aluminum plate type heat exchangers with high conductivity and performance, Indoor air quality with G filters, Excellent sound and heat isolation due to fully insulated cabinet Electronic Controller "Standard with the unit"

WHY HEAT RECOVERY UNITS model No Season Description Dry-bulb Wet-bulb Relative Temperature Temperature humidity Enthalpy Humidity Ratio Spesific Volume (ºC) (ºC) (%) (kj/kg) (gr/kg) (m /kg) Summer Outside,8 7, 7,7,,888 Summer Inside 7,9,,6,,88 Summer Frehs Air 8,7,8 6, 67,,,878 Summer Exhaust 9, 9, 8,9,,,87 Winter Outside - -,9 8,,9,,768 6 Winter Inside,8, 8,78 7,,8 7 Winter Frehs Air,9, 8,9 6,9,,88 8 Winter Exhaust 8, 7,9 9,7,79 6,,88 Fresh Air Cooling Capacity q = m a [ ( h - h ) - ( w - w ) h w ] q,88 [ - = (7,7 -,6) - ( ),8 q = 6,67 kw Energy Saving for Summer ] Fresh Air Cooling Capacity with V q = m a [ ( h - h ) - ( w - w ) h w ] q,88 [ q =, kw - = (67, -,6) - ( ),8 Q = q - q = 6,67 -, Q =, kw ] Fresh Air Heating Capacity [ q 6' = m a h h 6' - [ ] q 6' = 6, -,9,8 q 6' = 7,6 kw ] Energy Saving for Winter Fresh Air Heating Capacity with V [ 7 q 6' = m a h h 6' - 7 [ ] 7 q 6' = 6, - 6,9,8 7 q 6' =,99 kw Q = q 6' - 7 q 6 = 7,6 -,99 Q =,6 kw ]

SPECIFICATIONS MODEL 9 9 6 Air Flow Pa* m /h 9 9 6 Heat Recovery Efficiency % Efficiency up to 7 %, depending on working conditions Volt / Hz / ~ Electrical Data W 6 9 76 76...7 A,68,6 7,8 7,8,,, Air Filter Synthetic Filters for Fresh and Exhaust Air Optional Heater Electrical or Hot Water with 9/7ºC kw V/~ V/~ V/~ V/~ * 7 V/~ V/~ V/~ W L H L W Fresh Air Exhaust W Outdoor ød W Indoor W W ød Fresh Air Exhaust H Ls (min.) Filtre / Filter Service Clearance L W MODEL 9 9 6 Lenght [mm] L 8 Width [mm] Height [mm] Duct Connection [mm] W H ød 7 8 8 98 6 6 69 Ø6 Ø Ø Ø Ø Ø 6 Ø Weight [kg] 8 8 8 W 8 8 7 W 96 [mm] W W 8 8 8 8 7 6 Service clearance [mm] Ls

AIR FLOW - EXTERNAL STATIC PRESSURE 8 6 Air Flow [m /h] 9 6 7 8 9 6 8 Air Flow [m /h] Air Flow [m /h] 9 7 9 7 9 Air Flow [m /h] 6 8 6 8 Air Flow [m /h] 6 6 9 8 6 9 8 7 Air Flow [m /h] Air Flow [m /h]

INSTALLATION DETAILS Fresh Air Indoor Duct Type Electric Heater (Optional) L = D (min.) Exhaust Heat Recovery Unit Exhaust Service Clearance Outdoor Fresh Air heat recovery units have circular duct inlets and outlets. If the duct system is rectangular, the adaptors from circular to rectangular ducts could be supplied optionally. W OUTDOOR CONNECTION KIT (OCK) H D Outdoor connection kit is used to have the fresh air from the outside and exhaust the return air at the same time by not causing the return air at the same time by not causing the short circuit. The connection dimensions are suitable with the heat recovery unit inlets and outlets. MODEL 9 9 6 Width W 6 7 78 9 6 Height H 6 8 9 Depth D 6

ELECTRONIC CONTROL & SENSORS Electronic Controller "Standard with the unit" heat recovery units are controlled with standard electronic controllers (SEC). SEC has the following features; On / Off control, different fan speed for each fan (supply & exhaust), Electrical heater control manually or automatic regarding to the set temperature, FUNCTIONAL ELECTRONIC CONTROLLER (FEC) Functional electronic controllers (FEC) are used optionally. The unit is equipped with anti-freeze thermostat and protects the heat exchanger against to freezing. Frost protection for heat exchangers Clogged filtre Air quality sensor control Carbondioxide sensor control Timer function (daily and weekly programing) By-pass damper control Connectable to BMS or VRV/VRF system It is possible to increase the air quality by using different sensors such as humidity sensor, air quality sensor and carbon dioxide sensor. The air quality is checked by the sensor and it allows to change the fan speed automatically. 7

ACCESSORIES BY-PASS CONNECTION KIT (BCK) Heat recovery units are used to transfer the heat from the exhaust air to supply air. In the transition seasons, it is much more suitable to supply the fresh air directly to indoor by not entering to the heat exchanger. By-pass connection kit allows controlling the outdoor air automatically and supplying the outdoor air directly to the indoor when it is necessary. CIRCULAR DUCT SILENCER (SLT) duct silencers are classified in two groups as SLT models for circular duct systems and LN models for rectangular duct systems. SLT models are produced with the standard diameters of spiral ducts (ø,,,, ). LN models are produced with dimensions as required. Silencers can be connected to the duct system without any accessory. Glasswool insulation is used for the damping material as standard, rockwool insulation is optinal. 8

ACCESSORIES DUCT TYPE ELECTRIC HEATER (VCE) electrical heaters have TSEK certification, CE marked and GOST-R certification. The technical specifications of products meet the essential requirements in the directives EMC 89/6/EEC and are tested according to the standards EN -, EN 6--/- for EMC. Electrical heaters are produced in mono phase or three phase upon request in standard spiral duct dimensions. The heaters have two overheating protections. The heater can be controlled manually by SEC or automatically by FEC. DUCT TYPE WATER HEATER (HWC) duct type hot water coils produced at standard capacities. High efficient heat transfer can be acquired with high performance heat exchangers. The design, providing fast and easy installation and maintenance. DUCT TYPE BAG FILTER (VFK) FLC series, circular duct type bag filter units are produced as suitable for standard spiral duct dimensions. Units have galvanized steel frame and F7 class polyester bag filter according to EN 779. High efficiency bag filters made in synthetic microfiber which has 9 C max. operational temperature and have 8% efficiency. 9

SELECTION TABLE FOR ELECTRICAL CABLE CROSS SECTION DEPENDING ON THE CABLE LENGHT FOR HEAT RECOVERY UNIT Model Power [W] Fuse [A],, [mm ] x Cable Cross Section 6 6 7 9 9 8 76 6 8 6 76 6 8 6 9 6 7 86 6 6 7 86 78 FOR ELECTRICAL HEATER Model Model Power [kw] Fuse [A] [mm ] x Cable Cross Section,, 6 6 VCE 6--G-- 6 8 9 VCE --G-- 6 7 8 68 9 FOR ELECTRICAL HEATER Model Model Power [kw] Fuse [A] VCE --G-- x 6 [mm ] x Cable Cross Section,, 6 6 7 VCE --G-- x 6 6 97 6 9 VCE -7-G-- 7 x 6 7 7 6 VCE --G-- x 9 7 VCE --G-- x 6 6 Note : - Values are maximum cable lenght in meters. Find the cable cross area by regarding the total power. If the stage contactors are inside the electrical heater, find the cable cross area by regarding the power for each step individually.

TESTS heat recovery units are tested and controlled in function and safety after the production. The technical specifications of products meets the essential requirements in the directives EMC 89 / 6 / EEC, and are tested according to the standards EN - EN 6--/- for EMC. Technical specifications meet the essential requirements in the standard EN 6- and EN 6- Leakage Current Test (TS EN 6-) High Voltage Test (TS EN 6-) Insulation Test (TS 6 EN -) Earth Bond Test (TS EN 6-) CERTIFICATION CE-Declaration of Conformity TSE Certification GOST-R Certification GOST-R Certification

Heat Recovery Unit Heat Recovery Unit With Plug Fan Heat Pump Heat Recovery Unit Energy Recovery Unit Duct Type Electrical Heater Duct Type Electrical Heater Kitchen Hood Duct Type Silencer Ventilation Ducts