Overview of Significant 2017 NEC Changes

Similar documents
TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

2017 NEC Presented by: Russ LeBlanc

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Chapter 1 General... 5

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

NEC 2017 Changes and Their Effect Upon the ICT Industry

Second Revision No. 321 NFPA [ Detail ] Submitter Information Verification. Committee Statement. Make the following changes to 210.

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

TABLE 1-E (2017) Effective July 1, 2017

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Revisions for the 2011 National Electrical Code - Part 1

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

EFCOG Best Practice #213

SDEC 2017 Questions, Group 1

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

WIRING AND PROTECTION

ORDINANCE NO

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Electrical Tech Note 107

NEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

2011 and 2014 National Electrical Code Changes Residential Only

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

2009 ELECTRICAL CODE REQUIREMENTS

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

Instructor: L. Keith Lofland

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

TOM BURNS, PLANNING DIRECTOR

2017 NEC Significant Code Changes Part 3

2009 WESTERN SECTION CODE PANEL QUESTIONS

2014 National Electrical Code & NFPA 70E/Arc Flash

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Municipal Code of Chicago TITLE 14E ELECTRICAL CODE

Photovoltaic (Solar) Array Installation Guide

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

Revisions for the 2014 National Electrical Code Part 3

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Residential Wiring (2017 NEC) (Homestudy)

Spring Test 6 due 04/26/2013

NEC CODE QUESTIONS. Western Section IAEI 103 rd Annual Meeting September 17-19, 2007

RESIDENTIAL OVER. 4. Would it be permissible to hard- wire the dishwasher in question 3? If so, under what conditions?

Alberta Municipal Affairs

Student Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)

Intellectual Properties, Trademarks and Copyrights

NECA 169. Standard for Installing and Maintaining Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

Residential Wiring According to the 2011 NEC

Important Upcoming Dates

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

Second Revision No. 601 NFPA [ Section No [Excluding

Residential Wiring (2014 NEC) (Homestudy)

SW District 1. 1 Tony Tadysak Craig Mulder

Revisions for the 2011 National Electrical Code - Part 4

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Construction Codes Advisory Council

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

2016 Electrical Supplemental Plan Review List

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

District 1. 1 Tony Tadysak Craig Mulder

PANELBOARDS & BUILDING DISTRIBUTION

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

Residential Wiring According to 2011 NEC (Homestudy)

ll. Consistency Questions

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)

Revisions for the 2014 National Electrical Code

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

NEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

Arc-Fault Circuit Interrupters (AFCIs) and Ground-Fault Circuit Interrupters (GFCIs)

IEC and NCCER Mapping for Year 1

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

2017 NEC: Impact to Electrical System Designs

National Electrical Code Forum. Your Questions Answered

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Town of Cicero Local Code Amendments

National Electrical Code

*REPORT OF THE MOTIONS COMMITTEE

FIRE ALARM: BY OTHERS, IF REQUIRED.

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

File Name Description Approved. This doc shows the changes to take place in this revision. Changes are marked in comments titled "GLOBAL".

8. Multi-Family Residential Buildings

FIRE ALARM: BY OTHERS, IF REQUIRED.

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

A HOMEOWNERS HANDBOOK

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU ELECTRICAL PLAN REVIEW CHECKLIST

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

2010 Residential Ques. & Ans.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CITY OF LOS ANGELES ELECTRICAL PLAN CHECK CORRECTION LIST

Transcription:

Overview of Significant 2017 NEC Changes National Fire Protection Association. All rights reserved. Five New NEC Articles Article 426 Fixed Resistance and Electrode Industrial Heating Equipment Article 691 Large-Scale Photovoltaic (PV) Electric Supply Stations Article 708 Energy Storage Systems (ESS) Article 710 Stand-Alone Systems Article 712 Direct Current Microgrids National Fire Protection Association. All rights reserved. 1

Changes Impacting all Installations National Fire Protection Association. All rights reserved. Article 100 Structure 2014 NEC: That which is built or constructed 2017 NEC: That which is built or constructed, other than equipment (electrical). Electrical equipment may be mounted on or supported by a structure such as a concrete pad for outdoor equipment Clarifies pedestals such as RV power supply units do not require grounding electrode system 4 2

110.14 (D) Tightening Torque Added as new requirement to general rules for terminations Requires adherence to numeric torque markings on equipment or installation instructions Use of a calibrated torque tool specified unless manufacturer provides alternative method to accomplish proper connection Use of general listing instruction requirement in 110.3 (B) to require compliance with torque markings is no longer necessary 5 110.21 (A) (2) Reconditioned Equipment Equipment to be marked with name, trademark or other descriptive marking that identifies the organization responsible for reconditioning or refurbishing the equipment. Marking to indicate equipment is reconditioned and the date of the reconditioning. Original listing of the equipment cannot be the sole basis for equipment approval. Normal servicing of equipment is not considered to be reconditioning or refurbishing. Exception to this marking requirement for industrial occupancies. 6 3

338.10 (B) (4) (a) SE Cable in Thermal Insulation Revised requirement on temperature rating of cables installed in thermal insulation Only cables with 10 AWG and smaller conductors shall be required to default to 60 degree C ampacity Maximum temperature rating of conductor insulation is permitted to be used for ampacity correction or adjustment 7 404.22 Connection of Switches w/power Supplies New requirement for construction of electronic lighting control switches Increased use of devices like motion and occupancy sensors per energy conservation codes Devices required to be listed Devices cannot introduce current on the neutral conductor as of January 1, 2020 Exception to allow electronic lighting control devices that connect to EGC for existing installations 8 4

406.12 Tamper-Resistant Expansion Expansion of requirement for tamper-resistance protection of nonlocking, 125 volt and 250 volt 15- and 20-ampere receptacles in: Preschools and elementary educational facilities Business offices, corridors, waiting rooms and the like in clinics, medical and dental offices and outpatient facilities Subset of assembly occupancies described in 518.2 to include places of waiting transportation, gymnasiums, skating rinks, and auditoriums Dormitories 9 422.6 Listing of Appliances New requirement for appliances operating at over 50 volts to be listed 10 5

Changes Impacting Residential Installations National Fire Protection Association. All rights reserved. 210.8 & 210.8 (A) (7) Revised language to clarify how to establish measurement from a kitchen sink. The 6 ft. measurement is made from the top inside edge of the sink bowl Measurement is based on shortest path a cord would take from specified object to receptacle. Cord length is not measured through doors, doorways, or windows and is not considered to pierce floors, walls, ceilings, or other fixed barrier (such as refrigerator enclosure) Receptacle(s) in cabinet below the sink will now be excluded unless it is for the dishwasher (210.8 (D)) 12 6

210.11 (C) (4) Garage Branch Circuit New requirement for branch circuit dedicated to receptacles installed in dwelling unit garages At least one, 120 volt 20 ampere branch circuit Applies to attached garages and to detached garages supplied with power Circuit cannot supply lighting outlet inside or outside of garage Exception permits this circuit to supply readily accessible outdoor receptacle outlets 13 210.52 (C) (3) Peninsula Countertop Spaces Revised requirement on how to measure peninsula countertops for purposes of determining receptacle outlet location Peninsula is measured from the connected perpendicular wall One outlet minimum if peninsula countertop meets qualifying long (24 ) and short (12 ) dimensions. Sinks or countertop ranges may create separate peninsula spaces per 210.52 (C) (4) 14 7

210.52 (C) (3) Peninsula Countertop Spaces 2014 2017 15 310.15 (B) (7) Residential Service and Feeder Ampacity 3-conductor (2 hots and a neutral) feeders can now be derived from either single or three phase supplies. Any necessary correction or adjustment factors can be applied to the ampacity based on a conductor s insulation temperature rating. Service or feeder ratings are based on the standard ratings from 240.6. 16 8

336.10 (9) Uses Permitted for Tray Cable Type TC-ER cable permitted to be installed through structural members of one- and two-family dwellings Must be identified for this use TC-ER-JP Installation rules for this application follow those for Type NM cable Exception to use other than 60 degree C ampacity for generator connections with 75 degree C terminations 17 Changes Impacting Commercial, Institutional and Industrial Installations National Fire Protection Association. All rights reserved. 9

210.8 (B) Other than Dwelling Units Expansion of receptacle configurations requiring GFCI protection in occupancies other the dwelling units Applies to single-phase receptacles installed in locations locations specified in 210.8 (B) (1) (10) rated: 150 volts to ground or less 50 amperes or less Applies to three-phase receptacles installed in locations specified in 210.8 (B) (1) (10) rated: 150 volts to ground or less 100 amperes or less in 19 210.12 (C) & (D) AFCI Protection New requirement covering hotel and motel guest rooms and guest suites Applies to all 120 volt, single-phase, 15- and 20-ampere branch circuits supplying outlets in guest rooms and guest suites Requirement for AFCI protection of branch circuit extensions or modifications now includes dormitory units and has been relocated as new 210.12 (D) 20 10

210.71 Meeting Room Receptacle Outlets New requirement for meeting rooms not exceeding 1000 ft 2 Receptacles provided are non-locking, 125-volt, 15- and 20- ampere types If room can be divided with movable partitions room size is based on smallest room size with partitions closed Spacing of wall receptacles outlets is determined using 210.52 (A) (1) through (4) Location of required receptacles outlets can be determined by building owner or by a designer 21 220.12 Exception No. 2 Load Calculation for Office and Bank Occupancies New permissive exception for calculating general lighting loads in office and bank occupancies Based on requirements limiting lighting density contained in locally adopted energy code Permits reduction of 1 volt-ampere/ft 2 where energy code lighting density is less than 1.2 volt-amperes/ft 2 22 11

310.15 (B) (3) (c) Rooftop Ampacities Temperature adder table deleted. Further research indicated that heat internal to the raceway acted to insulate the conductors from solar radiation therefore concluding that the I2R losses and solar radiation did not create an additive heating effect. Raceways and cables must have air circulation around the raceway for proper heat dissipation. Raceways and cables that do not maintain 7/8 in. clearance from roof surface are subject to 60 degree temperature adder. XHHW-2 exception retained. 23 Changes Impacting Safe Work Practices and NFPA 70E Compliance National Fire Protection Association. All rights reserved. 12

110.16 (B) Arc Flash Marking of Service Equipment Service equipment rated 1200 A or more Installed in other than dwelling units In addition to general warning required by 110.16 (A), a permanent label shall be field or factory applied The label shall meet the requirements of 110.21(B) and contain the following information: (1) Nominal system voltage (2) Available fault current at the service overcurrent protective devices (3) The clearing time of service overcurrent protective devices based on the available fault current at the service equipment (4) The date the label was applied Exception: Service equipment labeling shall not be required if an arc flash label is applied in accordance with acceptable industry practice. 25 110.26 (A) (4) Limited Access Equipment operating at 1000 volts, nominal, or less to ground that is likely to require examination, adjustment, servicing, or maintenance while energized. If equipment is required by installation instructions or function to be located in a space with limited access, all of the following shall apply: 22 in. 22 in. minimum access above ceiling 22 in. 30 in. minimum access for crawl spaces Minimum width is 30 in. or the width of the equipment, whichever is greater Enclosure doors or hinged panels must open not less than 90 degrees. Front work space to comply with Table 110.26(A)(1). Height of the working space is that necessary to install the equipment Horizontal ceiling structural member or access panel shall be permitted in this space. 26 13

240.67 Arc Energy Reduction for Fusible Equipment New requirement for equipment containing fuses rated 1200 amperes or higher Requires additional arc-energy mitigation features where fuse clearing time is greater 0.07 seconds Documentation of location of fuses rated 1200 A or higher must be made available to designers, installers and maintainers Requirement has effective date of January 1, 2020 27 408.3 (A) (2) Panelboard Barriers Revision to require barriers for line terminals of service panelboards Exception exempts line terminals of panelboard having more than a single service disconnecting means 28 14

Changes Impacting Special Occupancies, Equipment and Conditions Chapters 5, 6 & 7 National Fire Protection Association. All rights reserved. 511.8 Wiring Under Commercial Garages Addition of requirement for underground wiring. Requires use of RMC or IMC Nonmetallic conduit types permitted with 24 of cover RMC or IMC required for the 2 foot length from below grade to point of emergence above grade Raceway must contain EGC No concrete encasement required 30 15

555.3 GF Protection at Marinas, Boatyards & Commercial & Noncommercial DF Revised from 100 ma to 30 ma trip level Applies to circuits supplying docking facilities Reduction of trip level was based on recommendation contained in FPRF study report Assessment of Hazardous Voltages/Current in Marinas, Boatyards and Floating Buildings Section 553.4 received no public input to make the same change remains at 100 ma level 31 590.4 (B) and (C) SE Cable for Temporary Installations Revised to permit Type SE (includes SER) cable to be used as a temporary wiring method for branch circuits and feeders in exposed locations above ground and in raceways installed underground Substantiation indicated that this is necessary on construction sites where temporary power is run to job trailers and from building to building and overhead wiring is impractical due to cranes and other heavy equipment Temporary wiring is required to be removed from construction sites upon completion of project 32 16

620.51 (D) (2) Short-Circuit Current Marking New requirement to field mark elevator control panels with the maximum available short circuit current available at line terminals. Marking must include date SCC was determined Shall be of sufficient durability to withstand environment Update and verify continued suitability of the control panel when modifications are made that change the available SCC Similar to 110.24 marking 33 680.14 Corrosive Environment New requirement on suitable wiring method for locations determined to be corrosive (acid, chlorine & bromine vapors) Corrosive locations include: Storage areas for pool chemicals (chlorine, bromine) Areas with circulating pumps, automatic chlorinators, filters, open areas under decks adjacent to or abutting pools Wiring methods Listed and identified for use, or RMC IMC PVC RTRC 34 17

680.25 Feeders Supplying Pool Equipment Use 680.14 (B) wiring method for that portion of a feeder installed in corrosive environments described in 680.14 (A) Liquidtight flexible nonmetallic conduit also permitted Wiring methods in corrosive environments described in 680.14 (A) must contain insulated copper equipment grounding conductor sized per Table 250.122, but not smaller than 12 AWG Feeders installed in noncorrosive environments can be wired using any appropriate Chapter 3 wiring method 35 Article 680 Part VIII Electrically Powered Pool Lifts New Part VIII with requirements for EPPL Lifts shall be listed and labeled Exceptions to listing and labeling where: Battery operated and battery is equal or less than low-voltage contact limit Solar operated or recharged lifts w/battery voltage of 24 volts or less Source is equal or less the LVCL and transformers or power supply is listed or labeled and meet 680.23 (A) (2) 36 18

695.15 Surge Protection Listed surge protection device (SPD) required in or on the fire pump controller. 37 700.3 (F) Permanent Provision for Temporary Connection New requirement for permanent means to connect portable generator when normal EPS is out of service Applies only where the EPS consists of a single alternate source 38 19

700.12 (D) Protection of Feeders, Supply Equipment, and Generator Control Wiring Revised to add new occupancies requiring 2-hour equipment protection: Health care occupancies where patients are incapable of selfpreservation Educational occupancies with more than 300 occupants 39 Changes Impacting Alternative Energy Technologies and Electric Vehicle Supply Equipment (EVSE) National Fire Protection Association. All rights reserved. 20

225.30 (A) (7) Number of Supplies EV Charging Equipment New condition permitting multiple feeders or branch circuits to EV charging equipment that is listed, labeled and identified for supply by multiple circuits. Corresponding requirement added to 625.47 41 625.1 Wireless Power Transfer Wireless Power Transfer (WPT). The transfer of electrical energy from a power source to an electrical load via electric and magnetic fields or waves by a contactless inductive means between a primary and a secondary device. Wireless Power Transfer Equipment (WPTE). Equipment consisting of a charger power converter and a primary pad. The two devices are either of the following: (1) Interconnected by an output cable or suitable conduit system (2) Contained within a single enclosure without an output cable or other suitable wiring means. 42 21

690.2 Functional Grounded PV System New definition describing grounding arrangement most commonly found in DC side of PV systems DC side of PV systems are generally not solidly grounded systems Grounding connections through protective devices, resistors or similar apparatus provide a reference point but may open under a fault condition such as PV GF protective devices Clarifies that there is not an intentionally grounded circuit conductor on the dc side of the system 43 690.12 (B) PV Rapid Shutdown Purpose of rapid shutdown systems are to protect emergency responders Concept of array boundary introduced Defined as area 1 foot in all directions from the array Conductors outside the array boundary or more than 1 ft. from the point of entry shall be reduced to 30 volts maximum within 30 seconds of RS initiation 44 22

690.12 (B) PV Rapid Shutdown Controlled Limits Conductors inside the array boundary must be protected by: Array being listed or field labeled as a rapid shutdown array, or Conductors shall be reduced to 80 volts with 30 seconds of RS initiation PV arrays with no exposed conductors or live parts and located not more than 8 ft. from ground or grounded surface not required to comply with 690.12 (B) (2) Requirement of 690.12 (B) becomes effective on January 1, 2019 45 690.47 Auxiliary Electrode for Array Revised to permit auxiliary electrodes GEC sized per 250.66 Ground-mounted support structures and metal frames of building or structure that qualify as a grounding electrode can be used as auxiliary electrode 46 23

Changes Impacting Limited Energy and Communications Systems National Fire Protection Association. All rights reserved. 725.144 (C) Transmission of Power and Data (POI) New requirement covering power over the internet types of Class 2 and Class 3 circuits where data and power are provided to connected devices Provides rules on maximum conductor ampacites based on 86 degree F. Ampacity correction necessary at higher ambient temperatures Provides new table for maximum conductor ampacities where in bundled cables 48 24

Thank you Jeffrey Sargent, NFPA Regional Electrical Code Specialist 617-799-4769 jsargent@nfpa.org 25