Water 1. Going through a water treatment system 2. Condensate is re-used & will be mixed with fresh water in deaerator 3. Mixture of this water is sent to a heat exchanger inside the boiler chimney (Economizer) 4. Add chemical to prevent scale, rust & foaming inside the boiler 5. Warm water is pumped into the boiler Fuel + Air for combustion 1. Air will be pre-heated in a heat exchanger inside the boiler chimney( Air preheater) 2. Fuel + warm air is injected into the boiler burner to produce heat inside the boiler Blowdown 1. To prevent the corrosion inside the boiler because mineral s multiplication inside the boiler Boiler water has to be blowdown out of the boiler regularly
Superheat Steam
Armstrong steam trap Yoshitake steam trap Gate/ball valve Y-strainer Sight glass Typical steam trap installation 1. 1 st shutoff valve (could be gate valve or ball valve) 2. 2 nd shutoff valve (could be gate valve or ball valve 3. Y-strainer 4. Sight glass (if the condensate is returned to boiler)
Everlasting boiler blowdown valve Quick opening Manual blowdown valve
Armstrong blowdown tank Backpressure regulating valve (Armstrong GPR200R) for controlling a low pressure condition inside the boiler blowdown flash steam recovery) Yoshitake safety relief valve for controlling the excessive pressure inside the blowdown tank Armstrong steam trap Yoshitake steam trap
Yoshitake drain separator Armstrong drain separator Yoshitake steam trap Armstrong steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Typical separator installation
Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Douglas sight glass Gate/ball valve Check valve Drip Leg Globe valve Steam Trap Globe valve The correct draining condensate from the main steam pipe
Always use Eccentric reducer to prevent condensate pooling
Expansion joint: Yoshitake US Bellows How do I change a steam expansion joint? The expansion joint can be replaced by an expansion joint of a similar design in the cold condition (when the plant is shut down). Shipping brackets should be placed on the expansion joint before un-flanging or cutting the expansion joint from the system.
Armstrong steam trap Yoshitake steam trap Armstrong thermostatic air vent Globe valve
Yoshitake PRV Armstrong PRV Yoshitake safety relief valve Yoshitake drain separator Armstrong drain separator Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Douglas sight glass Globe valve
Armstrong control valve Yoshitake safety relief valve Yoshitake drain separator Armstrong drain separator Arsmtrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Douglas sight glass Globe valve
Armstrong India Pressure reducing station package with GP2000
Armstrong India Pressure reducing station package with Control valve
Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve Yoshitake sight glass
Armstrong steam trap Yoshitake steam trap Armstrong thermostatic air vent Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve
Yoshitake temperature regulator Armstrong temperature regulator Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve
Armstrong control valve Armstrong drain separator Yopshitake drain separator Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve
Yoshitake PRV Armstrong PRV Armstrong steam trap Yoshitake steam trap Yoshitake safety relief valve Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve
Armstrong steam manifold Armstrong condensate collection manifold TVS4000 trap station Armstrong steam trap w/ universal connector
Yoshitake PRV Armstrong PRV Armstrong steam trap Yoshitake steam trap Yoshitake safety relief valve Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve
Yoshitake temperature regulator Armstrong temperature regulator Armstrong steam trap Yoshitake steam trap Yoshitake Y- strainer SF Y-strainer Yoshitake sight glass Gate/ball valve Globe valve at the bypass pipe
Armstrong flash tank Backpressure regulating valve (Armstrong GPR200R) for controlling a low pressure condition inside the flash steam recovery) Yoshitake safety relief valve for controlling the excessive pressure inside the blowdown tank Armstrong steam trap Yoshitake steam trap
Armstrong mechanical condensate pump Armstrong electric pump Armstrong combination steam trap & condensate pump Yoshitake mechanical condensate pump Yoshitake combination steam trap & condensate pump
Armstrong electric condensate pump Armstrong mechanical condensate pump Armstrong mechanical condensate pump Armstrong mechanical condensate pump + steam trap for closed system Armstrong combination mechanical condensate pump + steam trap for closed system Yoshitake condensate pump