Autodesk Moldflow Insight AMI Molding Window Analysis

Similar documents
Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Transient Groundwater Analysis with Slope Stability

Installing ProSeries 2004

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

INDOOR CLIMATE OF A SINGLE ZONE

Installing ProSeries 2005

Assigning profiles to an e-stack or Passive Stack (S1500, S1200 & R-Series)

Interior Design Tutorial

Assigning profiles to a Breathing Buildings NVHR Unit (NVHR900 & NVHR1100)

Avigilon Control Center System Integration Guide

Patriot Systems Limited

Tutorial: How to Download and Install Lumberyard v or greater

Step 1 - Install ProSeries Basic software

WeatherLink for Alarm Output Addendum

BENSON Boiler Technology

DESIGN OF INJECTION MOULD TOOL AND MOULD FLOW ANALYSIS OF EXHAUST FAN USING ABS PLASTIC MATERIAL

Chapter 4 - Preparation of Stormwater Site Plans

HikCentral Web Client. User Manual

Avigilon Control Center 5 System Integration Guide

Chapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs

HikCentral Web Client. User Manual

Installing ProSeries software for stand-alone use

PM-ANALYZE. Overview 1. System Configuration 2. Operation 3. Analysis of Alarms and process values. User Interface 4

Oracle Communications Performance Intelligence Center

MultiSite Manager. Setup Guide

Getting Started with Live Exceptions

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Dashboard for Windows V1.1.0

SPLIT SYSTEMS SELECTION & OPTIMIZATION GUIDE

Avigilon Control Center 5 System Integration Guide

Chapter. Configuring NICE NiceVision. Version build 10. Configuring Third-Party Programs. SightLogix, Inc

Alarms Updated 03/26/2018

FCD-wire Contents. List of Figures

ISO 6394 INTERNATIONAL STANDARD

Managing Network Alarms and Events

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

AK SM 800 Commissioning Guide

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

Manage Alarm Profiles

International Journal of Advance Engineering and Research Development

Before you install ProSeries Express Edition software for network use

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

System Galaxy Quick Guide

LineGuard 2300 Program User Manual (FloBoss 107)

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Avigilon Control Center System Integration Guide

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Before you install ProSeries software for network use

Daikin VRV Sizing & Simulation Plug-in User Guide

Oracle Retail Merchandising System Release Notes Release 12.0 May 2006

ND4000 Manual Marine Hydraulics

Monitor Alarms and Events

Machine needle shut-off nozzle Type SHP (high performance) spring operated

Daikin VRV Systems Plugin VE2012 User Guide

ISO INTERNATIONAL STANDARD. Earth-moving machinery Hazard detection systems and visual aids Performance requirements and tests

ISO INTERNATIONAL STANDARD

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Avigilon Control Center 5 System Integration Guide

Interior Design Tutorial

Chapter 6. Alarm History Screen. Otasuke GP-EX! Chapter 6 Alarm History Screen 6-0. Alarm History Screen 6-1. Display Alarm History in List 6-2

Welcome to ProSeries Express Edition tax software

Configuring Thresholds

Smoke Layer Height and Heat Flow through a Door

Refining and Petrochemical Heater trouble shooting

i-vu CCN 4.0 Owner s Guide

Functional Description AIS01 - Analog Input Signal Version 5.2-0

Avigilon Control Center System Integration Guide

ISO 1403 INTERNATIONAL STANDARD. Rubber hoses, textile-reinforced, for general-purpose water applications Specification

Help. Help Software Tutorial. Building a Load Sizing Project with an SETC Humidifier and a mini SAM-e Distributor

Platform Services BACnet Alarm Management

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

1 Air Handling Units In ICE

Patriot Systems Limited

MPL3115A2 Sensor Toolbox User s Guide

ISO INTERNATIONAL STANDARD. Road vehicles Four-pole electrical connectors with pins and twist lock Part 2: Tests and requirements

I/A Series A 2 Software FoxAlert Alarm Manager

FortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B

Ion Gateway Cellular Gateway and Wireless Sensors

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Failure Modes, Effects and Diagnostic Analysis

ISO 6396 INTERNATIONAL STANDARD. Earth-moving machinery Determination of emission sound pressure level at operator's position Dynamic test conditions

Lesson 10: Configuring Events IGSS. Interactive Graphical SCADA System. Lesson 10: Configuring Events 1

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

ArchestrA Direct Connect

Functional Description Flow01 - Temp & Press Compensation Flow Version 5.2-0

Plan Submittal Checklist

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

Shanghai Xixun-----professional supplier of Led sign control system website: un.com Step2, plug u-disk into computer, open LED editor and choose upgra

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Security Management System - Configuring Video Analytics

Honeywell Enterprise Alpha version 5.86

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Moxa Proactive Monitoring User s Manual

Transcription:

Autodesk Moldflow Insight 2012 AMI Molding Window Analysis

Revision 1, 22 March 2012. This document contains Autodesk and third-party software license agreements/notices and/or additional terms and conditions for licensed third-party software components included within the product. These notices and/or additional terms and conditions are made a part of and incorporated by reference into the Autodesk Software License Agreement and/or the About included as part of the Help function within the software.

Contents Chapter 1 Molding Window analysis.............................. 1 Molding Window analysis.................................... 2 Setting up a Molding Window analysis......................... 2 Specify process settings for a Molding Window analysis.............. 2 Molding Window analysis.................................... 3 Process Settings Wizard dialog Molding Window Settings............ 3 Molding Window Advanced Options dialog...................... 3 Molding Window Input Range dialog.......................... 4 Molding window process settings defaults dialog Input Factors tab...... 4 Molding window process settings defaults dialog Preferred/Feasible Window tab................................................. 5 Chapter 2 Molding Window Derivation Calculation................ 7 Chapter 3 Molding Window Derivation Inputs.................... 8 Chapter 4 Molding Window Derivation Color..................... 9 iii

iv

Molding Window analysis 1 The Molding Window analysis is used to calculate the best preliminary process settings for your study. This analysis quickly provides you with recommendations for the injection time, mold temperature, and melt temperature to use as preliminary inputs for a Fill+Pack analysis. How it works The Molding Window analysis uses the part geometry and the selected material and injection location to run a series of calculations, varying the process settings each time. Specified process ranges and limits may also be used, if selected. For each of these calculations, the Molding Window analysis checks whether certain results are achieved and then recommends the injection time and the temperature zones to mold your part. The analysis shows the feasible and preferred molding zones, and also shows which process settings will result in the highest quality molding. Injection time range The Process Settings Wizard provides an option that allows you to specify how the Molding Window analysis chooses the range of fill times to scan to determine the optimum molding window. The following options are available: Automatic Wide Refined Specified The most appropriate injection time range with which to run the analysis is determined. If you choose this method, run the analysis, and display results, the results will focus on the preferred window (displayed in green), if one exists. If a preferred molding window does not exist, the results will span the wide range (displayed in green, yellow, and red). The analysis is run across the widest possible range of injection times. If you choose this method, run the analysis, and display results, the results will span the full range (displayed in green, yellow, and red). within which to run optimization analyses. A suitable injection time range is determined, based on the mold and melt temperature ranges, and then the analysis is run within that range. If you choose this method, run the analysis, and display results, the results will focus on the preferred window (displayed in green), if one exists. If a preferred molding window does not exist, the results will focus on the feasible window (displayed in yellow), if one exists. Allows you to enter a specific injection time range. 1

Molding Window analysis You can use the Molding Window analysis to calculate the best preliminary process settings for your study. Setting up a Molding Window analysis The following table summarizes the setup tasks required to prepare a Molding Window analysis. The setup tasks below are for non fiber-filled, or fiber-filled thermoplastic materials. Setup task Analysis technology Molding processes Meshing the model Checking the mesh before analysis Analysis sequence Selecting a material Injection locations Process settings Specify process settings for a Molding Window analysis When performing a Molding Window analysis, you do not have to specify any process settings other than the defaults. You may change the default settings if there are particular characteristics of your study that you want the Molding Window analysis to consider. 1 Ensure that your model is meshed 2 Make sure that you have selected the Molding Window analysis, selected a material and an injection location. 3 Click Home tab > Molding Process Setup panel > Process Settings, or double-click the Process Settings icon in the Study Tasks pane. The Molding Window Settings dialog appears. 4 Change settings, as required. 5 Click OK. 6 Click Finish, or Analyze to perform the analysis. 2 Molding Window analysis

Molding Window analysis Use this dialog to specify settings for a Molding Window analysis. Process Settings Wizard dialog Molding Window Settings This page of the Process Settings Wizard, which can be accessed by clicking (Home tab > Molding Process Setup panel > Process Settings), is used to specify the molding window related process settings for the analysis sequence. NOTE: Some of the items listed below may not be available on the current dialog. This is dependent on the molding process and analysis sequence selected. Injection molding machine Mold temperature range to analyze Melt temperature range to analyze Injection time range to analyze Advanced options... Select and edit an injection molding machine to simulate your molding machine during the analysis. You can configure the injection unit, hydraulic unit, and clamping unit. Select the range of mold temperatures to be used in the Molding Window analysis. You can specify a temperature range, or have the program calculate it automatically. Select the range of melt temperatures to be used in the Molding Window analysis. You can specify a temperature range, or have the program calculate it automatically. Specifies how you want the molding window solver to choose the range of injection times to scan. Displays the advanced options for the analysis. Molding Window Advanced Options dialog This dialog is used to specify the molding window analysis related advanced options for the analysis sequence. To access this dialog, ensure that you have selected the analysis sequence Molding Window, click (Home tab > Molding Process Setup panel > Process Settings), then click Advanced options. Molding Window analysis 3

Limits for calculation of feasible molding window Limits for calculation of preferred molding window Lists the parameters taken into consideration in the calculation of the feasible molding window, and specifies any upper limits to be applied to those parameters. Lists the parameters taken into consideration in the calculation of the preferred molding window, and specifies the upper limits to be applied to those parameters. Molding Window Input Range dialog This dialog is used to specified the range of values to be analyzed in the molding window analysis for the analysis input (mold temperature, melt temperature or injection time that was set to Specified on the Molding Window Settings page of the Process Settings Wizard. To access this dialog, ensure that you have selected the analysis sequence Molding Window, click (Home tab > Molding Process Setup panel > Process Settings), set one of the three range to analyze options to Specified, then click Edit range. Mold temperature range Melt temperature range Injection time range Allows you to set the range of mold temperatures to be used in the calculation of the molding window. Allows you to set the range of melt temperatures to be used in the calculation of the molding window. Allows you to select the range of injection times to scan in order to determine the optimum molding window. Molding window process settings defaults dialog Input Factors tab The Input Factors tab of the Molding window process settings defaults dialog is used to specify default values to control which input factors will be considered in a Molding Window analysis, and the range of values to be analyzed for each. NOTE: The values used for the current analysis sequence may be changed by entering the desired values on the Process Settings Wizard Molding Window Settings dialog. 4 Molding Window analysis

Mold temperature range to analyze Melt temperature range to analyze Injection time range to analyze Allows you to set the range of mold temperatures to be used in the calculation of the molding window. Allows you to set the range of melt temperatures to be used in the calculation of the molding window. Allows you to select the range of injection times to scan in order to determine the optimum molding window. Molding window process settings defaults dialog Preferred/Feasible Window tab The Preferred/Feasible Window tab of the Molding window process settings defaults dialog is used to specify default values for the limits used to calculate the preferred window and feasible window in a Molding Window analysis. NOTE: The values used for the current analysis sequence may be changed by entering the desired values on the Process Settings Wizard Molding Window Settings dialog. Limits for calculation of feasible molding window This section of the dialog lists the parameters taken into consideration in the calculation of the feasible molding window, and specifies any upper limits to be applied to those parameters. The feasible molding window calculates the largest possible range of injection times, mold temperatures and melt temperatures within which the part can be molded. Limits for calculation of preferred molding window Shear rate limit This section of the dialog lists the parameters taken into consideration in the calculation of the preferred molding window, and specifies the upper limits to be applied to those parameters. The preferred molding window calculates the range of injection times, mold temperatures and melt temperatures within which the part can be molded based on a comprehensive set of limiting criteria intended to ensure the production of quality parts. Specifies whether a limit (maximum value) is to be applied to the shear rate Molding Window analysis 5

in the part and runner system when calculating the preferred/feasible molding window. Shear stress limit Flow front temp. drop limit Flow front temp. rise limit Injection pressure limit Clamp force limit Specifies whether a limit (maximum value) is to be applied to the shear stress in the part and runner system when calculating the preferred/feasible molding window. Specifies whether a limit (maximum value) is to be applied to the drop in temperature of the melt front when calculating the preferred/feasible molding window. Specifies whether a limit (maximum value) is to be applied to the rise in temperature of the melt front when calculating the preferred/feasible molding window. Specifies whether a limit (maximum value) is to be applied to the injection pressure to fill the part when calculating the preferred/feasible molding window. Specifies whether a limit (maximum value) is to be applied to the clamp force required to fill the part when calculating the preferred/feasible molding window. 6 Molding Window analysis

Molding Window Derivation Calculation 2 The Molding Window analysis runs a series of quick calculations on the part, varying the processing conditions each time. The processing conditions are only varied within their ranges of acceptability, as specified in the material information in the material database. The analysis uses these variables across their ranges: Injection time Melt temperature Mold temperature The Molding Window analysis checks whether five conditions are acceptable for each of these calculations, using the following inputs: Material Part geometry Injection location Maximum injection pressure Each calculation is represented by a single point on the Molding Window results, which is colored red, yellow, or green according to whether the following five conditions are acceptable or not: Injection pressure. Temperature at flow front. Shear stress. Shear rate. Short shot. 7

Molding Window Derivation Inputs 3 The Molding Window calculation uses information about the injection location and the size, shape, and thickness of the model to determine the lengths of the flow paths from the injection location to the points on the model's extremities. The Molding Window analysis uses the following inputs: Material Part geometry Injection location Maximum injection pressure Material A Molding Window analysis can only be run with materials that have a specified maximum recommended shear rate and a specified maximum recommended shear stress. Maximum injection pressure You can change the default value if your injection molding machine is capable of injecting at higher pressures. If a Molding Window calculation predicts that the injection pressure required to fill the part is greater than the maximum injection pressure, then that point on the display corresponding to the conditions used in the calculation will be red. 8 Molding Window Derivation Inputs

Molding Window Derivation Color 4 The Molding Window Analysis checks whether the five conditions are acceptable and these calculations are checked against their ranges of acceptability. Green An area of the Molding Window is green if all of these cases are true. The part is not a short shot. The injection pressure required to fill the part is less than 80% of maximum machine injection pressure capacity. Temperature at the flow front is less than 10 C above the injection (melt) temperature. Temperature at the flow front is greater than 10 C below the injection (melt) temperature. The shear stress is less than the maximum specified for the material in the material database. The shear rate is less than the maximum specified for the material in the material database. P<0.8Pmax T<Tmelt+10 C T>Tmelt 10 C <max < max Yellow An area of the Molding Window is yellow if it does not satisfy all the conditions for being displayed as green, and all of these cases are true. The part is not a short shot. The injection pressure required to fill the part is less than the maximum machine injection pressure capacity. P<Pmax Red An area of the Molding Window is red if either of these cases is true. The part is a short shot. 9

The injection pressure required to fill the part is greater than the machine injection pressure specified. P>Pmax 10 Molding Window Derivation Color