Split Type System. Air to Water Heat Pump

Similar documents
This presentation is posted for public use. ACEEE does not endorse any product or service.

LV Series. SEER 20+ Wall Mount Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only

FAQ. Wall Mount Heat Pump or Cooling Only

Produced by the Residential Solution Sales Division. Daikin AC Americas, Inc.

Frequently Asked Questions. A 3 in 1 Renewable Energy Solution For Home Heating, Cooling and Domestic Hot Water

FTQ. Daikin Inverter Ducted Heat Pump

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

THE HEAT PUMP CHOICE OF PROFESSIONALS

Daikin Inverter Ducted Systems

FREQUENTLY ASKED QUESTIONS

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Heating - Domestic hot water - Cooling. the intelligent way to comfort

Daikin Altherma hybrid heat pump. The natural combination

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Heat Pumps COMFORT NEED IT. When You

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Industrial Application. Refrigeration

DAIKIN Modular Inverter Air Cooled Chiller

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

The natural ombination

GEOTHERMAL DESIGN GUIDE

DES IGN I T ALI A N O

Do you want a versatile solution

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Pricelist. Heating. All seasons Perfect c mfort

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Outdoor Split Unit. Pure and Simple

AFFORDABLE RENEWABLE CLEAN

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Multi-Positional Vertical Combination

Split Type Air Conditioners

Heating - Domestic hot water - Cooling. THE AIR to WATER HEAT PUMPS

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Air Conditioners. Summer

White paper: New Ecodesign rules and energy labelling for space and water heaters

Heating. Catalogue. Climate comfort. All Seasons. For end users. Heating. Air Conditioning. Applied Systems. Refrigeration

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

All-in-one comfort for residential applications. Product catalogue Heating

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

EEDEN technical data ERHQ AA

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

MYSON. ivector. A NEW GENERATION OF INTELLIGENT FAN CONVECTORS. heatingthroughinnovation. NOW INCLUDING. the ivector 4-pipe

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Saving energy comes naturally to us.

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

HEATING COOLING HOT WATER PRODUCT LINE

JH Series Installation

Water cooled VRV IV W-series

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Daikin Altherma Low Temperature monobloc heat pump

Geothermal. Comfort Systems

Heating 2014 Pricelist

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Geothermal HIGH EFFICIENCY HEATING & COOLING. the logical choice for energy efficient residential heating and cooling

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Geothermal Comfort Systems

Air-to-water heat pump systems

Advance Split

DESIGN ITALIANO

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

About Daikin: WARNINGS:

C13-Series Engineering Guide

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Multi Inverter Air Conditioning Condensing Units - Summary

GEOTHERMAL: THE SMARTER CHOICE

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units


Residential Application/Design Manual

Heating Version 1. Pricelist

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Heating. Pricelist Heating PERFECT C MFORT. Catalogue. All seasons PERFECT C MFORT. Heating. Air Conditioning. Applied Systems.

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

TECHNICAL SPECIFICATIONS

Daikin Altherma. : 11, 14, 16 kw. : 11, 14 and 16 kw

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

QUANTUM. Reliable solar hot water, whenever you want it

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

TECHNICAL SPECIFICATIONS

Water Source Heat Pumps

EVI + INVERTER MODELS A Q U A P U R A

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

AHRI Certification Program Scopes - COOLING

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

Heating. Why choose a Daikin heating system? 20. Products overview 24. Combination tables 26. Options & accessories 74

Europe s new energy label: raising the bar on energy efficiency

The Future of Central Heating Today. Air source heat pump systems

Vertical Combination Unit. Pure and Simple

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

High temperature hydrobox for VRV

Transcription:

Split Type System Air to Water Heat Pump

EXPERTISE AND INNOVATION Daikin Altherma offers complete flexibility for new construction and deep energy refurbishment projects. Using a low temperature hydronic circuit, these systems can be applied to satisfy a whole host of applications and configurations and can satisfy all your heating, cooling and domestic hot water needs. An Integrated Solution Daikin Altherma is a highly efficient air to water heat pump, hydronic system that provides an integrated, all electric solution for heating, cooling, and domestic hot water with solar thermal connectivity. With the ability to be combined with under floor heating, fan coil units, low temperature radiators, a domestic hot water tank, solar connectors, or a room thermostat, Daikin Altherma provides excellent flexibility and maximum year round comfort. System Attributes Daikin Altherma is a powerful solution with key benefits for the environment, enhanced efficiency and use in diverse applications. Environment Efficiency 1. All Equipment contains materials that are fully recyclable. 2. Daikin Altherma system inherent design and operational features mean effective tie in to Grid Tied Solar PV (Low start up amps, operating amps, no locked rotor amps). 3. DHW Production via 3rd Party Solar Thermal solution and using the highly efficient Daikin Altherma serving as the Auxiliary Solution. 4. An air source Heating and DHW solution with NO Localized Gas or Oil consumption thus reduced CO2 emission, no Gas venting, no drilling, and no safety concerns. 1. Enhanced energy savings via Inverter Compressor operation where energy consumption matches the load. 2. Further savings via the Outdoor Reset Function to control water temperatures in relation to the current Ambient temperatures. 3. Operational efficiencies (COP up to 4.5) similar to or better than Geo Thermal WSHP solutions, but with no added cost of well drilling and land excavation. Application 1. Excellent flexibility for the architect / designer to apply the Daikin Altherma system to suit any residence design, scale or performance scope. 2. Unobtrusive, space saving and aesthetically satisfying complete Heating, Cooling and DHW solution. 3. Full utilization of hydronic circuit, giving small diameter piping, high heat transfer coefficient and the excellent comfort of Low Sound Levels from In Floor Radiant, Low Velocity Fan Convectors or Radiators.

DESIGN FOR IDEALCOMFORT Daikin Altherma components work together to provide the ideal comfort and water temperature. 1. Outdoor Unit: An efficient use of energy from the air Utilizing a natural source of energy, the outdoor unit extracts heat from the outside air and transfers it through refrigerant piping to supply heating. Installed as a split system consisting of an outdoor compressor unit and Hydrobox containing the hydronic components or a MonoBloc system with a single outdoor unit combining both the compressor and hydronic components, Daikin Altherma delivers an energy efficient system, compact and easily installed. 2. Hydrobox: A boiler from a heat pump source The Hydrobox heats the water that circulates through low temperature radiators, floor heating systems or fan coil units and provides domestic hot water. With optional cooling, the Hydrobox has the ability to reverse the cycle to provide chilled water. 3. Domestic Hot Water Tank: For low energy consumption Available in two sizes, the domestic hot water tank provides warm water primarily from the thermal energy from the outside air. With specially placed system components, a heat exchanger connected to the heat pump along with a supplemental electrical heating element to boost hot water temperature for any additional water heating needs, warm water is always provided with maximum energy efficiency. 4. Solar Thermal Connection Kit: Averaged over a year, the sun delivers half of the energy needed to bring domestic hot water up to the desired temperature for free. By connecting a solar boiler to the Daikin Altherma system, rays are transferred into heat and stored in the hot water storage tank. Room Thermostat: For convenient temperature regulation With the wired room thermostat, the ideal temperature can be conveniently regulated easily and quickly. Daikin Altherma Split Type System Capacity Nominal 1.5 Ton to 4.5 Ton Application Heating and (optional) cooling Domestic hot water Configuration R-410A Refrigerant Piping Water (H 2 O) Piping Installer s Advantages Field Supply Connectable Heating Emitters (5) Outdoor (compressor) unit Indoor (hydronic parts) unit Between outdoor unit and indoor unit Between indoor unit and indoor heating/cooling appliances No extra insulation of H 2 O piping required to protect from freezing up Under floor heating Low temperature radiators Overhead Radiant Cooling panels Fan coil units Fan convectors Combinable With Domestic hot water storage tank (3), Solar thermal connection kit (4) and field supply Solar thermal panels (6) for hot water production Third party thermostats

ENERGYSAVINGS FOR PEACE OF MIND Reduced operating costs with Daikin Altherma Heat Pumps Daikin Altherma is a domestic heating and hot water system based on air water heat pump (AWHP) technology. It represents a flexible and cost effective alternative to a fossil heating solution. How does a heat pump work? Air passes through the heat exchanger and absorbs latent heat from the outside air and evaporates. Vapor passes into the compressor and is compressed, concentrating the heat. Hot vapor is condensed where heat is rejected and the vapor condenses back into a liquid. The rejected heat passes into the central heating and hot water system, ready for use in the home. Liquid refrigerant passes through an expansion valve, ready to start the cycle again. The Heat Pump Advantage The Energy Challenge How Energy is Used in Residences (2005)* Heating and Hot Water account for the largest portion of monthly utility costs The Daikin Difference The inverter compressor in combination with outdoor reset set point control results in excellent operating COP s. T LW = water temperature from Altherma to the floor heating loops T LW 78 F T LW 86 F 14 F The Savings Benefit Typical Savings 20% or more The Daikin Altherma heat pump boiler works more efficiently and saves more energy than a traditional heating systems using fossil fuel. Typical Operating Costs: T LW 93 F T LW 100 F Example 61 F *2005 is the most recent year for which data is available. Source: U.S. Energy Information Administration, Residential Energy Consumption Survey 2005 (*) Comparison for the same ambient temperature (36 F) Conditions: Required annual heating energy: 20,000 kwh. Source: Energy prices based on EUROSTAT statistics [first semester 2007]. Leading Product Warranty Daikin offers industry leading comprehensive standard warranties for extra peace of mind with your investment. Extended warranties are also available.

LEADING TECHNICAL PERFORMANCE Split System Outdoor Unit ERLQ018BAVJU ERLQ024BAVJU ERLQ030BAVJU ERLQ036BAVJU ERLQ048BAVJU ERLQ054BAVJU Nominal capacity Heating Btu/h 19,620 23,340 28,760 38,200 47,800 54,600 Cooling Btu/h 24,570 27,840 28,560 47,600 59,100 60,600 COP 4.25 4.12 3.81 4.55 4.42 4.18 EER 10.41 9.7 9.33 12.4 10.2 8.9 ERLQ018,024,030BA Dimensions (Net) HxWxD in. 28-9/10 x 32-1/2 x 11-8/10 46 1/6 x 35 7/16 x 12 5/8 Heating F ( C) -4-77 (-20-25) -4-95 (-20-35) Operation range Cooling F ( C) 50-110 (10-43) 50-114.8 (10-46) DHW F ( C) -4-110 (-20-43)* -4-109.4 (-20-43) Min ft. 10 10 10 16.4 16.4 16.4 Refrigerant Piping Max ft. 98 98 98 246 246 246 Height ft. 66 66 66 98.4 98.4 98.4 Power Supply 208-230V/1Ph/60Hz ERLQ036,048,054BA MCA A 18 18 MOP A 20 30 Indoor Unit EKHB_030BA_VJU EKHB_054BA_VJU Dimensions HxWxD in. 36 5/16 x 19 3/4 x 14 7/32 36 5/16 x 19 3/4 x 14 7/32 Leaving Water Temp Heating F ( C) (59) 77-131* ((15) 25-55) (59) 77-131* ((15) 25-55) Range Cooling F ( C) 41-71.6 (5-22) (If using EKHBX030) 41-71.6 (5-22) (If using EKHBX054) Water Volume gal. 0.18 0.26 Water Flow Rate Min./Max GPM 3.17 / - 4.23/15.32 Back Up Heater Power Supply 208-230V/1Ph/60Hz 208-230V/1Ph/60Hz Capacity kw 3kW 3kW Single Stage Back MCA A 14.3 A 14.3 A Up Heater (BA3VJU) MOP A 20 A 20 A EKHB BA Optional Fan Coil Unit EFWT A Model Number EFWT024 EFWT036 EFWT048 EFWT060 Heating Btu/h 25,000 34,800 50,200 60,900 Nominal Cooling (T) Btu/h 28,600 32,000 42,700 52,400 Capacity Cooling (S) Btu/h 22,400 25,800 34,700 42,400 Dimensions HxWxD in. 40x20x20 40x23x20 48x21-1/4x28 Nominal Air Flow Rate CFM 800 1200 1600 1825 EWT Range Heating F ( C) 100-125 (37-52) Cooling F ( C) 42-50 (5-10) Nominal Water Flow Rate gpm 4.5 6 8 10 Nominal Pressure Drop Ft Hd 5.5 5.5 5.4 7.9 Power 120V/1Ph/60Hz AEVLU MCA 6 10 14 15 (ECM) MOP 15 15 15 15 Power 120V/1Ph/60Hz APVLU MCA 3.8 7.5 10 13.1 (PSC) Electrical MOP 15 15 15 15 Power 208-230V/1Ph/60Hz MCA 3 4 6 9 MOP 15 15 15 15 AEVJU (ECM) Elec. Heat Options 5, 10kW 5, 10kW 15,20,25kW 15,20,25kW Notes: 1. Cooling Capacity is based on 50 F Entering Water Temp and 80 F DB/67 F WB Entering Air Conditions. 2. Heating Capacity is based on 110 F Entering Water Temp and 70 F DB Entering Air Conditions. 3. Refer to detailed capacity tables for further information pertaining to the entire entering water temperature range and for flow rates and pressure drop. 4. Refer to engineering data book for further information on electric heat options. 5. Std efficiency models with PSC motor are available on request. Optional Solar Kit Two Stage Back Up Heater (BA6VJU) Measuring conditions: Heating Ta DB/WB 44.6 F/42.8 F (7/6 C) - LWC 95 F (35 C) (DT=9 F (5 C) - Cooling Ta 95 F (35 C) - LWE 64.4 F (18 C) (DT=9 F (5 C) * Booster heater operation from 95 F (35 C) onwards (1) These conditions are based on under floor heating/cooling application Capacity kw 6kW 6kW MCA A 28.6 A 28.6 A MOP A 30 A 30 A EKSOLHWBAVJU Pressure Drop gal. 3.12 Max. Inlet Temp F ( C) 230 (110) Heat Exchanger Heat Exchange Capacity W/K 1,400 Logarithmic Mean Temperature Difference (LMTD) K 5 Pump Number of Speeds 3 Power Input W/K 46 Water Circuit Piping Connections Diameter in. 3/4 FBSP Ambient Max. F 95 (35) Temperature Min. F 33.8 (1) Power Supply 208-230V/1 ph/60 Hz Power Supply Intake from indoor unit Dimensions (Net) H x W x D in. 30-1/32 x 12 x 10-1/32 Features State of the art technology. Utilize renewable energy to heat your home and your hot water. High Efficiency for savings on operating costs. Configurable with Fan Coil Units, Fan Convectors, Under Floor Radiant Heating and Low Temperature Radiators. Low Sound Levels. Advanced Energy Saving Features. Outdoor Reset Function as Standard. 30 50% reduction in CO2 emissions. Optional Domestic Hot Water Model Number EKHWS050 EKHWS080 Water volume gal. 52.8 79.2 Max. water temperature F 185 Max. water pressure PSI 145 Insulation (Polyurethane foam) Min. thickness in. 39452 Height in. 45-3/8 63 Diameter in. 22-7/8 Booster heater kw 3 MCA A 14.3 MOP A 20 Power supply 208-230V/1Ph/60Hz EKHWS BA3 Material inside tank Stainless steel (DIN 1.4521) - 316L Material outside casing Epoxy-coated mild steel Currently there is no appropriate U.S. recognized testing and rating standard for technology that is of Air to Water design and can solve Hydronic Heating, Domestic Hot Water and Cooling requirements in a single packaged solution. As such, the U.S. Department of Energy (DOE) has issued Daikin with Waivers (Case number: CAC-024, as published from page no. 34,731 in the DOE Federal Register on June 18th, 2010, and Case number CAC- 028 as published from page no. 11,438 in the DOE Federal Register on March 2nd, 2011) and assigned an "Alternate Test Procedure" detailing testing requirements to establish full load COP and EER values.

WARNINGS: Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local Daikin sales office. Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES. Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM. All of the Daikin Group's business facilities and subsidiaries in Japan are certified under the ISO 14001 International standard for environmental management. 2012 Daikin Industries, Limited. Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD. www.daikindifference.com Distributor or Dealer Information: Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 www.daikinac.com/altherma 866.4DAIKIN 972.245.1510 CCFAWSSUSE12-05R For all equipment installation & application limitations please refer to the specific Engineering Data Books. Daikin s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.