TABLE OF CONTENTS EBLQ01-016AA6V3

Similar documents
TABLE OF CONTENTS EDLQ AA6V3

EEDEN technical data ERHQ AA. Altherma. Altherma

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERHQ BAV3

EEDEN technical data ERHQ AA

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

TABLE OF CONTENTS RMXS-E8V1B

EEDEN technical data. Altherma TM

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

DESIGN MANUAL Version 1.0

Air Conditioning Technical Data RZASG-MV1

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioners. Technical Data FBQ-C

Air Conditioning Technical Data RZAG-MV1

General Outline: Altherma

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioning Technical Data AZAS-MY1

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Service Manual. Air Cooled Refrigeration Condensing Unit

Air Conditioning. Technical Data EEDEN AZQS-BV1

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

EEDEN technical data EKSOLHWAV1

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

technical data air conditioning systems RZQ C7Y1B Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems Indoor Units FCQ-C8VEB

Daikin Altherma. : 11, 14, 16 kw. : 11, 14 and 16 kw

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

TABLE OF CONTENTS EKHWS

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Digital Inverter 4 series 8 & 10HP

EEDEN technical data EKRTR. Altherma. Altherma

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Industrial Application. Refrigeration

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Heating. Technical Data EEDEN ERRQ-AY1

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

EDUS Heat Pump - D-Series

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Advance Split

High temperature air-to-water heat pumps

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

Heating. Pricelist Heating PERFECT C MFORT. Catalogue. All seasons PERFECT C MFORT. Heating. Air Conditioning. Applied Systems.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

Heating - Domestic hot water - Cooling. THE AIR to WATER HEAT PUMPS

Blue Box Epsilon Echos +

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Heating - Domestic hot water - Cooling. the intelligent way to comfort

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

PUHZ-SHW140YHA PUHZ-SHW230YKA

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air Conditioners. Technical Data RZQG-L

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

Heating 2014 Pricelist

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

EEDEN technical data. Applied Systems. Air-cooled with heat recovery EWTP MBYN

Pricelist. Heating. All seasons Perfect c mfort

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

Transcription:

Monobloc EBLQ0-06AA6V TABLE OF CONTENTS EBLQ0-06AA6V Features............................................................. 2 2 Specifications....................................................... Nominal Capacity and Nominal Input............................... Technical Specifications............................................. Main components................................................... 4 Electrical Specifications............................................. 5 Options.............................................................. 7 4 Capacity tables..................................................... 9 Heating capacity tables.............................................. 9 Cooling capacity tables............................................. 0 5 Dimensional drawing & centre of gravity....................... Dimensional drawing................................................ 6 Piping diagram..................................................... 2 7 Wiring diagram..................................................... Wiring diagram...................................................... 8 Sound data......................................................... 6 Sound pressure spectrum........................................... 6 9 Installation.......................................................... 7 Service space....................................................... 7 0 Operation range................................................... 8 Hydraulic performance............................................ 9 Static pressure drop unit............................................ 9

6 ac0 o- r l e b0 h o t Ln lo Monobloc EBLQ0-06AA6V Features 6 A A m Q B M EA Reversible monobloc with bottom plate heater H2O piping between outdoor unit and indoor heating appliances Freeze protection of hydraulic parts Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort 2

2 Specifications Monobloc EBLQ0-06AA6V 2- NOMINAL CAPACITY AND NOMINAL INPUT EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Condition Heating Nominal kw.20 4.00 6.00 capacity Cooling Nominal kw 2.85 5.99 6.7 capacity Heating PI Nominal kw 2.47.20.79 Cooling PI Nominal kw.78 5.65 6.28 COP Nominal 4.54 4.7 4.22 EER Nominal.9 2.8 2.66 Condition 2 Heating Nominal kw 0.87.0 5.06 capacity Cooling Nominal kw 0.00 2.50.0 capacity Heating PI Nominal kw.22.9 4.62 Cooling PI Nominal kw.60 5.0 5.85 COP Nominal.7.5.26 EER Nominal 2.78 2.6 2.24 Notes Condition : cooling Ta 5 C - LWE 8 C (Dt=5 C); heating Ta DB/WB 7 C/6 C - LWC 5 C (Dt=5 C) Condition 2: cooling Ta 5 C - LWE 7 C (Dt=5 C); heating Ta DB/WB 7 C/6 C - LWC 45 C (Dt=5 C) 2 2-2 TECHNICAL SPECIFICATIONS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Casing Colour Ivory white Material Painted galvanised steel Dimensions Unit Height mm,48 Width mm,45 Depth mm 82 82 82 Packing Height mm,557 Width mm,500 Depth mm 40 40 40 Weight Unit kg 80 80 80 Packed unit kg 200 200 200 Packing Material Wood Carton Plastic foil Weight kg 20 20 20 Operation Range Sound Level (nominal) Sound Level (Night quiet) Heating - Ambient Heating - Waterside Cooling - Ambient Cooling - Waterside Domestic hot water -Ambient Domestic hot water - Waterside Heating Cooling Heating Cooling Min CDB -5-5 -5 Max CDB 5 5 5 Min C 5 5 5 Max C 55 55 55 Min CDB 0 0 0 Max CDB 46 46 46 Min C 5 5 5 Max C 22 22 22 Min CDB -5-5 -5 Max CDB 4 4 4 Min C 25 25 25 Max C 80 80 80 Sound Power Sound Pressure Sound Power Sound Pressure Sound Pressure Sound Pressure dba 64 64 66 dba 5 5 52 dba 65 66 69 dba 50 52 54 dba 42 42 4 dba 45 45 46

2 Specifications Monobloc EBLQ0-06AA6V 2 2-2 TECHNICAL SPECIFICATIONS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Refrigerant Type R-40A Charge kg 2.95 2.95 2.95 Control Electronic expansion valve Nr of Circuits Refrigerant Oil Type Daphne FVC68D Charged Volume l.0.0.0 Defrost Method Pressure equalising Defrost Control Sensor for outdoor heat exchanger temperature Capacity Control Method Inverter controlled Safety Devices High pressure switch Fan motor thermal protector Fuse Notes The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Conditions: Ta DB/WB 7 C/6 C - LWC 5 C (DT = 5 C) Conditions: Ta 5 C - LWE 7 C (DT = 5 C) 5-25 C: BUH only, no heat pump operation = during commisioning including piping + PHE + back-up heater / excluding expansion vessel E(D)(B)L* model can reach -20 C / E(D)(B)L*6W model can reach -25 C but without capacity guarantee 2- MAIN COMPONENTS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Air heat Specifications Length mm 857 857 857 exchanger Nr of Rows 2 2 2 Fin pitch mm.4.4.4 Nr of Passes 5 5 5 Face area m²... Nr of Stages 60 60 60 Tube type Hi-XSS Fin Type WF fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Quantity 2 2 2 Air Flow Rate Heating High m³/min 90 90 90 (nominal at 20V) Cooling High m³/min 96 00 97 Fan Discharge direction Horizontal Motor Quantity 2 2 2 Model Brushless DC Motor Speed Steps 8 8 8 (nominal) Heating rpm 760 760 760 Cooling rpm 780 780 780 Fan Motor Output W 70 70 70 Drive Direct drive Compressor Quantity Motor Model JT00G-VD Type Hermetically sealed scroll compressor Motor Output W 2,200 Starting Method Inverter driven Motor Crankcase Output W Heater Pump Type Water cooled Nr. of speed 2 2 2 Nominal ESP Heating kpa 52.5 4.5 5.0 unit Cooling kpa 55.9 49. 46.8 Power input W 20 20 20 4

2 Specifications Monobloc EBLQ0-06AA6V 2- MAIN COMPONENTS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Water side Heat exchanger Type Brazed plate Quantity Water volume l.0.0.0 Water flow rate Min. l/min 6 6 6 Water flow rate Heating l/min 2. 40. 45.9 Nom. Cooling l/min 6.8 45.9 48.0 Water flow rate Max. l/min 58 58 58 Insulation material Foamed synthetic elastomer Expansion Volume l 0 0 0 vessel Maximum water pressure bar Pre pressure bar.0.0.0 Water filter Diameter perforations mm Material Brass Water circuit Piping connections inch G5/4 (FEMALE) Piping inch 5/4" Safety valve bar Manometer Yes Drain valve / Fill valve yes Shut off valve yes Air purge valve yes Total water volume (6) l 5.5 5.5 5.5 2 2-4 ELECTRICAL SPECIFICATIONS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Power supply compressor component Current Power supply compressor component Power supply hydraulic component Current backup heater Running Current Current backup heater Main Power Name V Phase ~ Frequenc Hz 50 50 50 y Voltage V 20 20 20 Voltage range Minimum V -0% Maximum V +0% Current Minimum Ssc value kva Equipment complying with EN/IEC 6000--2(*) Maximum Cooling A 22.8 27.4.9 running current Current Wiring connections Current backup heater Recomen ded fuses For power supply compressor component Type A 2 2 2 See installation manual Power Supply Phase ~ Frequenc Hz 50 50 50 y Voltage V 20 20 20 Running Current Back-up heater + booster heater Z-max Minimum Ssc value Back-up heater A 26 26 26 +EK*V A 9(26+) Back-up heater Back-up heater + booster heater A 0.29 0.29 0.29 A 0.7 0.7 0.7 +EK*V kva Equipment complying with EN/IEC 6000--2(**) 6V 5

2 Specifications Monobloc EBLQ0-06AA6V 2 2-4 ELECTRICAL SPECIFICATIONS EBLQ0AA6V EBLQ04AA6V EBLQ06AA6V Power supply hydraulic component Voltage range Minimum V -0% Maximum V +0% Wiring Connection type for power supply hydraulic compartment connections Quantity of wires G Select diameter and type according to national and local regulations Connection type for power supply connection to optional sanitary tank + Q2L Quantity of wires G Select diameter and type according to national and local regulations For more details on voltage range and current refer to installation manual Connection type for connection with R5T Quantity of wires Wire included in option EKHWS* Wire included in option EKHWS* Connection type for connection with AP Quantity of wires Depends on thermostat type, refer to installation manual Select diameter and type according to national and local regulations Voltage 20V / Maximum current: 00mA / Minimum 0.75mm² Connection type for connection with M2S Quantity of wires G Select diameter and type according to national and local regulations Voltage 20V / Maximum current: 00mA / Minimum 0.75mm² Connection type for connection with MS Quantity of wires G or 4G Select diameter and type according to national and local regulations Voltage 20V / Maximum current: 00mA / Minimum 0.75mm² Notes Power supply compressor compartment is for compressor, fan, pump and controller In accordance with EN/IEC 6000-- (), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys () smaller than or equal to Zmax. Installer can reduce capacity of the heater from 6 to kw. The current is then reduced from 26 to A. Instructions see installation manual. Installer can reduce capacity of the heater from 6 to.5kw. The current is then reduced from 8.7 to 5A. Instructions see installation manual. ()European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A. (2) European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 6A =< 75A per phase. () System impedance Power supply hydraulic compartment is for the electric heater. The optional domestic warm water tank has a separate power supply. Conditions: Ta DB/WB 7 C/6 C - LWC 5 C (DT = 5 C) 6

Monobloc EBLQ0-06AA6V Options EBLQ0-06AAV Kit availability for E(D/B)(H/L)Q0-06AA* Altherma Monoblock / Low temperature -Phase -Phase Zone 2 Zone Zone 2 Zone EDLQ***AA6V EDHQ***AA6V EDLQ***AA6W EDHQ***AA6W EBLQ***AA6V EBHQ***AA6V EBLQ***AA6W EBHQ***AA6W Reference Description 0 04 06 0 04 06 0 04 06 0 04 06 EKRPHB Digital I/O PCB V V V V V V V V V V V V EKBPHT6Y Bottom plate heater - - - V (2) V (2) V (2) - - - V (2) V (2) V (2) EKDK04 drain plug kit - - - V (2) V (2) V (2) - - - V (2) V (2) V (2) EKHWS50BV Stainless domestic hot water tank 50l 20V V V V V V V V V V V V V EKHWS200BV Stainless domestic hot water tank 200l 20V V V V V V V V V V V V V EKHWS00BV Stainless domestic hot water tank 00l 20V V V V V V V V V V V V V EKHWSU50BV Stainless domestic hot water tank 50l 20V V V V V V V V V V V V V EKHWSU200BV Stainless domestic hot water tank 200l 20V V V V V V V V V V V V V EKHWSU00BV Stainless domestic hot water tank 00l 20V V V V V V V V V V V V V EKHWS200BZ2 Stainless domestic hot water tank 200l 2 400V V V V V V V V V V V V V EKHWS00BZ2 Stainless domestic hot water tank 00l 2 400V V V V V V V V V V V V V EKHWE50AV Enamel domestic hot water tank 50l 20V V V V V V V V V V V V V EKHWE200AV Enamel domestic hot water tank 200l 20V V V V V V V V V V V V V EKHWE00AV Enamel domestic hot water tank 00l 20V V V V V V V V V V V V V EKHWE200AZ2 Enamel domestic hot water tank 200l 2 400V V V V V V V V V V V V V EKHWE00AZ2 Enamel domestic hot water tank 00l 2 400V V V V V V V V V V V V V EKHWET50AV Wallmounted enamel domestic hot water tank 50l 20V V V V V V V V V V V V V EKSOLHWAV Solarkit (4) V V V V V V V V V V V V EKRTW Wired room thermostat option kit V V V V V V V V V V V V EKRTR Wireless room thermostat option kit (incl. receiver) V V V V V V V V V V V V EKRTETS External temperature sensor option kit () V V V V V V V V V V V V Remark: Other combinations are not guaranteed. () Input/Output PCB that provides two additional output connections (remote alarm and remote ON/OFF signalisation). In EKSOLHWAV, the same digital I/O PCB as for EKRPHB is already included (2) It is not allowed to combine bottom plate heater and drain plug kit () EKRTETS can only be used in combination with EKRTR (4) Kit to be mounted on domestic hot water tank that provides connection to solar panels for additional water heating. Note: E(D/B)L* units include special equipment (insulation, heater sheet,... ) to ensure good operation in areas where low ambient temperature can occur together with high humidity conditions. In such conditions the E(D/B)H* models may experience problems with severe ice build-up on the aircooled coil. In case such conditions are expected, the E(D/B)L* must be installed instead. TW5809-7

Monobloc EBLQ0-06AA6V Options EBLQ0-06AA6V Bivalent system Space heating with an auxiliary boiler (alternating operation) Space heating application by either the altherma indoor unit or by an auxiliary boiler connected in the system. An auxiliary contact decides whether either the EKHB* indoor unit or the boiler will operate. This auxiliary contact can e.g. be an outdoor temperature thermostat, an electricity tariff contact, a manually operated contact, etc. Sanitary warm water in such an application is always provided by the sanitary water tank which is connected to the indoor unit, including when the boiler is in operation for space heating. The auxiliary boiler can be integrated in the pipework and in the field wiring according to the illustrations below. Field wiring Boiler thermostat Boiler thermostat C th KA K2A Boiler thermostat Auxiliary contact (normal closed) Heating only room thermostat Auxiliary relay for activation of EKHB* unit (field supply) Auxiliary relay for activation of boiler (field supply) Operation When the room thermostat (th) closes, either the EKHB* unit or the boiler starts operating, depending on the position of the auxiliary contact ( C ) Make sure that auxiliary contact ( C ) has sufficient differential or time delay so as to avoid frequent changeover bethween the EKHB* unit and the boiler. If the auxiliary contact ( C) is an outdoor temperature thermostat, make sure to install the thermostat in the shade, so that it is not influenced or turned ON/OFF by the sun. Frequent switching may cause corrosion of the boiler in an early stage. Contact the manufacturer of the boiler. During heating operation of the EKHB* unit, the Altherma unit will operate so as to achieve the target leaving water temperature as set on the user interface. When weather dependent operation is active, the water temperature is determined automatically depending on the outdoor temperature. During heating operation of the boiler, the boiler will operate so as to achieve the target leaving water temperature as set on the boiler controller. Never set the target leaving water temperature setpoint on the boiler controller above 55 C. Make sure to only have expansion vessel in the water circuit. An expansion vessel is already premounted in the Altherma unit. Outdoor unit 2 Indoor unit Heat exchanger 4 Pump 5 Shut-off valve 6 Collector (field supply) 7 Shut-off valve 8 Motorised -way valve (field supply) 0 Booster heater Heat exchanger coil 2 Sanitary water tank 5 Boiler (field supply) 6 Aquastat valve (field supply) 7 Shut-off valve (field supply) 8 Non-return valve (field supply) FHL... Floor heating loop (field supply) Make sure to configure the DIP switch SS2- on the PCB of the EKHB* switch box correctly. Refer to Room thermostat installation configuration in the installation manual supplied with the unit. Make sure that return water to the EKHB* heat exchanger never exceeds 55 C. For this reason, never put the target leaving water temperature setpoint on the boiler controller above 55 C and it required, install an aquastat(*) valve in the return water flow of the EKHB* unit. Daikin shall not be held liable fo any damage resulting from failure to observe this rule. (*)The aquastat valve must be set for 55 C and must operate to close the return water flow to the EKHB* unit when the measured temperature exceeds 55 C. When temperature drops to a lower level, the aquastat valve must operate to open the return water flow to the EKHB* unit again. TW57759-4A 8

Monobloc EBLQ0-06AA6V 4 Capacity tables 4 - Heating capacity tables EBLQ0-06AA6V Maximum Heating Capacity (Peak values) Model LWC [ C] 0 5 40 45 50 55 Tamb HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] HC [kw] PI [kw] 4 Maximum Heating Capacity (integrated values) Model LWC 0 5 40 45 50 55 Tamb HC PI HC PI HC PI HC PI HC PI HC PI CC HC PI LWE LWC Tamb (a) SYMBOLS : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/00-2006 (kw) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/00-2006 (kw) : Power input (kw), measured acc. Eurovent 6/C/00-2006 (kw) : Leaving Water Evaporator temperature ( C) : Leaving Water Condensor temperature ( C) : Ambient temperature ( C) RH=85% : only E(D/B)L* NOTES TW5802-A Cooling capacity Capacity is according to Eurovent rating standard 6/C/00-2006 and valid for chilled water range Dt = 8 C Capacity values may not be extrapolated below 7 C leaving water temperature 2 Heating capacity Capacity is according to Eurovent rating standard 6/C/00-2006 and valid for chilled water range Dt = 8 C Power input Power input is total of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/00-2006. Pump power input to be added = 90 W (according EN45). For E(D/B)LQ* models only:if Tamb < 4 C: bottom plate heater power input to be added = 95W 9

Monobloc EBLQ0-06AA6V 4 Capacity tables 4-2 Cooling capacity tables EBLQ0-06AA6V 4 Maximum Cooling Capacity Model Tamb 20 25 0 5 40 45 LWE [ C] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] CC [kw] PI [kw] TW5802-A CC HC PI LWE LWC Tamb (a) SYMBOLS : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/00-2006 (kw) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/00-2006 (kw) : Power input (kw), measured acc. Eurovent 6/C/00-2006 (kw) : Leaving Water Evaporator temperature ( C) : Leaving Water Condensor temperature ( C) : Ambient temperature ( C) RH=85% : only E(D/B)L* NOTES Cooling capacity Capacity is according to Eurovent rating standard 6/C/00-2006 and valid for chilled water range Dt = 8 C Capacity values may not be extrapolated below 7 C leaving water temperature 2 Heating capacity Capacity is according to Eurovent rating standard 6/C/00-2006 and valid for chilled water range Dt = 8 C Power input Power input is total of indoor and outdoor unit, except the circulation pump; according to Eurovent rating standard 6/C/00-2006. Pump power input to be added = 90 W (according EN45). For E(D/B)LQ* models only:if Tamb < 4 C: bottom plate heater power input to be added = 95W 0

Monobloc EBLQ0-06AA6V 5 Dimensional drawing & centre of gravity 5 - Dimensional drawing EBLQ0-06AA6V Hole for anchor bolt Center of gravity. Drain outlet 2. Waterpiping outlet. Waterpiping inlet 4. Power supply cables intake 5. Field wiring intake 6. Service door switchbox 7. Service door hydraulic module 8. Service port 9. Service door compresor module 0. Pump. REMOCON kit (to be installed indoors). Shut off valve 4. Blow off valve 5. Blow off drain (flexible base) 6. Pressure gauge 7. Water filter 8. loadup ctrl motor + (8a) nipple 9. Switchbox terminals 20. Switchbox terminals option sanitary warm water tank 2. Drain & fill valve Center of gravity 5 Cutaway2 Cutaway Cutaway TW5804-

6 Piping diagram Monobloc EBLQ0-06AA6V EBLQ0-06AA6V 6 Safety valve Air purge Expansion vessel Pressure gauge Evaporator Condenser Filter Filter Distributor Heat exchanger Outlet Pump Shut off valve Electric heater body Service port 5/6 Capillary tube Flowswitch Filter Inlet Shut off valve Drain & fill valve Accumulator Stop valve (with service port 5/6 flare) RT : Thermistor (Air) R2T : Thermistor (discharge) RT : Thermistor (Suction) R4T : Thermistor (Liquid ) R5T : Thermistor (middle) R6T : Thermistor (Liquid 2) SNPH : Pressure sensor YE : Electronic expansion valve EHC : Crankcase heater YS YS SPH M*F M*C RT R2T RT R4T : 4-way valve : Injection valve : High pressure switch : Fan motor : Compressor : Outlet water heat-exchanger thermistor : Outlet water backup heater thermistor : Refrigerant liquid side thermistor : Inlet water thermistor Heating Cooling TW585-A EBLQ0-06AA6V Expansion vessel Pressure gauge Filter Filter Heat exchanger Safety valve Air purge Evaporator Condenser Distributor Outlet Pump Shut off valve Electric heater body Service port 5/6 Flowswitch Filter Inlet Shut off valve Drain & fill valve Accumulator Stop valve (with service port 5/6 flare) RT : Thermistor (Air) R2T : Thermistor (discharge) RT : Thermistor (Suction) R4T : Thermistor (Liquid ) R5T : Thermistor (middle) R6T : Thermistor (Liquid 2) SNPH : Pressure sensor YE : Electronic expansion valve EHC : Crankcase heater YS YS SPH M*F M*C RT R2T RT R4T : 4-way valve : Injection valve : High pressure switch : Fan motor : Compressor : Outlet water heat-exchanger thermistor : Outlet water backup heater thermistor : Refrigerant liquid side thermistor : Inlet water thermistor Heating Cooling TW5805-A 2

Monobloc EBLQ0-06AA6V 7 Wiring diagram 7 - Wiring diagram EBLQ0-06AA6V Power supply Reactor terminal position Position of compressor terminal Only for E(D/B)LO* Compressor module switchbox To hydromodule switchbox (8.5 Page 2 Notes: This wiring diagram only applies to the compressor module switchbox 2 L: Live N:Neutral g: Field wiring D : Terminal strip F : Connector T : Connection R : Protective earth (screw) : Connector p : Noiseless earth G : Terminal 4 NOT APPLICABLE 5-6 Do not operate the unit by short-circuiting protection device SPH 7 Colors: BLK: black, RED: red, BLU: blue, WHT: white, YLW: yellow, ORG: orange, BRN: brown, GRN: green 8 Confirm the method of setting the selector switches (DS) by service manual. Factory setting of all switches: OFF. AP A2P AP BS BS4 C C4 DS EHC EH FU F2U FU F4U F5U F6U F7U F8U, F9U HP 7P (AP) HAP (AP) HAP (A2P) KM K2M KR (AP) KR (A2P) K2R (AP) KR (AP) LR LR L4R MC MF M2F PS QDI R R4 RT R2T RT R4T R5T R6T R7T SNPH SPH VR, V2R VR XM YE YS YS ZC Z9C ZF Z4F Optional connector X6A X77A XY Printed circuit board (Main) Printed circuit board (INV) Printed circuit board (Noise filter) Push button switch Capacitor DIP switch Crankcase heater Bottomplate heater Fuse (T,5A/250V) Fuse (T,5A/250V) Fuse (T 6.A/250V) Fuse (T 6,A/250V) Fuse (T 6,A/250V) Fuse (T 6,A/250V) Fuse (T 5,0A/250V) Fuse (T,0A/250V) Pilotlamp (service monitor - orange) Pilotlamp (service monitor - green) Pilotlamp (service monitor - green) Magnetic contactor Magnetic relay (YS) Magnetic relay Magnetic relay (Y2S) Magnetic relay (EHC) Reactor Reactor (For outdoor fan motor) Motor (Compressor) Motor (Fan) (upper) Motor (Fan) (lower) Switching power supply Earth leakage protector Resistor Thermistor (Air) Thermistor (Discharge) Thermistor (Suction) Thermistor (Heat exchanger) Thermistor (heat exchanger middle) Thermistor (Liquid) Thermistor (Fin) Pressure sensor Pressure switch (High) Power module Diode module Terminal strip Electronic expansion valve Solenoid valve (4 way valve) Solenoid valve Noise filter Noise filter Connector Connector Connector 7 Option Wiring dependent on model Reactor box El. comp. Assy (Position of elements) Arrow A Arrow B 2TW586-

7 Wiring diagram 7 - Wiring diagram Monobloc EBLQ0-06AA6V 7 EBLQ0-06AA6V Power supply N-50Hz 20V Only for E(D/B)LO* Compressor module switchbox To hydromodule switchbox (8.5 Page 2 AP A2P AP A4P BS BS4 C C4 DS EH EHC FU, FU, F4U F6U F7U, F8U HP 7P (A2P) HAP (AP) KR K4R K0R KR LR MC MF M2F PS QDI R R2 RT R2T RT R4T R5T R6T RC R0T SNPH SPH TC VR V2R, VR VT XM YE YS ZC ZC ZF Z4F Optional connector XY Printed circuit board (Main) Printed circuit board (INV) Printed circuit board (Noise filter) Printed circuit board Push button switch Capacitor DIP switch Bottomplate heater Crankcase heater Fuse (T 6.A/250V) Fuse (T 5.0A/250V) Fuse (F,0A/250V) Light Emit. Diode (Serv. Monitor-Orange) Prepare, Test --------- Flickering Malfunction Detection -- Light up Light emitting diode (service monitor green) Magnetic relay (YS) Magnetic relay (EHC) Magnetic relay Magnetic relay Reactor Motor (Compressor) Motor (Fan) (upper) Motor (Fan) (lower) Switching power supply Field earth leakage breaker (00mA) Resistor Resistor Thermistor (Air) Thermistor (Discharge) Thermistor (Suction) Thermistor (Heat exchanger) Thermistor (heat exchanger middle) Thermistor (Liquid) Signal receiver circuit Thermistor (Fin) Pressure sensor Pressure switch (High) Signal transmission circuit Power module Diode module IGBT Terminal strip (Power supply) Electronic expansion valve Solenoid valve (4 way valve) Noise filter (ferrity core) Noise filter Connector Position of compressor terminal Wire entrance Notes: This wiring diagram only applies to the compressor module switchbox 2 L: Live N:Neutral g: Field wiring D : Terminal strip F : Connector T : Connection R : Protective earth (screw) : Connector p : Noiseless earth G : Terminal 4 NOT APPLICABLE 5-6 Do not operate the unit by short-circuiting protection device SPH 7 Colors: BLK: black, RED: red, BLU: blue, WHT: white, YLW: yellow, ORG: orange, BRN: brown, GRN: green 8 Confirm the method of setting the selector switches (DS) by service manual. Factory setting of all switches: OFF. Option Wiring dependent on model El. comp. Assy (Position of elements) 2TW5806-4

7 Wiring diagram 7 - Wiring diagram Monobloc EBLQ0-06AA6V EBLQ0-06AA6V 7 Domestic hot water tank Only forekhws*v Option See note 7 For *KHWSU*V Option Power supply 20V N 50Hz >> See note 2 << Standard 6kw (_) See note 0 Reduced kw See note 0 Outdoor unit From compressor module switchbox (B.7 PageA) Alarm output Cooling/heating on/off output Solar input Only for EKRPHB & EKSOLHWAV Option See note 8 heating cooling Example field supply thermostat Only for EC/BLQOption Only for EKSOLHWAVOption 20V AC supply from PCB Only for *KRTW* Option Only for *KRTR* Option wiretype(spst) Only for *KHW(S/E)* Option Only for EKRTETS* Option Solar pump connection See note 9 NO valve NC valve Domestic hot water tank Only for *KHWE*Option Only for *KHW(S/E)*Option See note 7 For *KHWSU*V Option Only for EKHW Option Wiring dependent on model Field wiring Only for EKSOLHWAV Option Option Field wiring PCB FB Wire colour Only for *KHW Option Electric heater fuse 2A *KHW kit fuse F2B 20A User interface AP : Main PCB A2P : User interface PCB AP (*KRTW) : Thermostat (PC=power circuit) A4P (EKRTR) : Solar/remote alarm PCB A4P (*KRTR) : Receiver PCB EH-E2H-EH : Backup heater element -2- (6 kw) E4H : Booster heater (kw) E5H : Switchbox heater E6H : Expansion vessel heater FB : Fuse backup heater FT : Thermal fuse backup heater F2B : Fuse booster heater F8U, F9U : Fuse,0A F 250V FU : Fuse,5A T 250V for PCB FU2 : Fuse 5A T 250V FuS, FuR : Fuse 5A 250V for solar/remote alarm PCB KM : Contactor backup heater step KM : Contactor booster heater K4M : pump relay K5M : Contactor for backup heater all-pole disconnection K7M : Relay for solar pump MP : Pump M2S : 2 way valve for cooling mode MS : way valve: floorheating/domestic hot water PHC : Optocoupler input circuit QDI : Earth leakage protector QL : Thermal protector backup heater Q2L : Thermal protector /2Booster heater RH (*KRTR) : Humidity sensor RT (*KRTW/R) : Ambient sensor R2T (EKRTETS) : External sensor (floor or ambient) RT : Outlet water heat-exchanger thermistor R2T : Outlet water backup heater thermistor RT : Refrigerant liquid side thermistor R4T : Inlet water thermistor R5T (*KHW*) : Domestic hot water thermistor SL : Flowswitch SS : Solar pumpstation relay S2S : benefit kwh rate power supply contact SS : DIP switch ST : thermostat switchbox heater S2T : thermostat expansion vessel heater TR : Transformer 24V for PCB VS, V2S : Spark suppression, 2 XM-X0M : Terminal strips X2Y : Connector Domestic hot water tank Only for *KHWE*V Option Notes: This wiring diagram only applies to the compressor module 2 Use one and same dedicated power supply compressor module switchbox, hydromodule switchbox and *KHW* option :Field wiring No/Nc normal open/normal closed SPST - single pole single throw. 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting any protection device. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet 7 For *KHWSU*V, refer to option manual 8 Option PCB works with an external 20V AC power supply unit. (N,L) 9 For EKSOLHWAV, refer to option manual 0 Backupheater kw reduction, refer to installation manual 2TW5806-5

8 Sound data Monobloc EBLQ0-06AA6V 8 - Sound pressure spectrum EBLQ0-06AA6V E(D/B)(H/L)Q0* HEATING E(D/B)(H/L)Q04* HEATING E(D/B)(H/L)Q06* HEATING EBLQ0-06AA6V E(D/B)(H/L)Q0* HEATING E(D/B)(H/L)Q04* HEATING E(D/B)(H/L)Q06* HEATING 8 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Notes: Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) TW5807-4 Measuring location (discharge side) TW5807-2 EBLQ0-06AA6V E(D/B)(H/L)Q0* COOLING E(D/B)(H/L)Q04* COOLING E(D/B)(H/L)Q06* COOLING EBLQ0-06AA6V E(D/B)(H/L)Q0* COOLING E(D/B)(H/L)Q04* COOLING E(D/B)(H/L)Q06* COOLING Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Notes: Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa 4 If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) TW5807- Measuring location (discharge side) TW5807-6

9 Installation 9 - Service space EBLQ0-06AA6V A. Non stacked installation Monobloc EBLQ0-06AA6V Legend Unit: mm Suction side obstacle Discharge side obstacle 9 Left side obstacle Right side obstacle Top side obstacle Obstacle is present In these cases, close the bottom of the installation frame to prevent discharged air from being bypassed. 2 In these cases, only 2 units can be installed. This situation is not allowed. B. Stacked installation Figures between ( ) indicate the dimensions only for the 00-25-40 class models.. Obstacles exist in front of the outlet side 2. Obstacles exist in front of the air inlet Do not stack more than one unit. About 00mm is required as the dimension for laying the upper outdoor unit s drain pipe. Get the portion A sealed so that air from the outlet does not bypass. C. Multiple-row installation. Installation of one unit per row 2. Installing multiple units (2 units or more) in lateral connection per row Relation of dimensions of H, A, and L are shown in the table below. L H H < L L A 0<L /2 H 50 (250) /2 H < L 200 (00) Installation impossible TW2679-4 7

0 Operation range Monobloc EBLQ0-06AA6V EBLQ0-06AA6V 0 only EB(H/L)* Cooling mode Outdoor temp. ( CDB) Leaving evaporator Water temperature ( C) No heat pump operation, back up heater only Heating mode Outdoor temp. ( CDB) (*) E(D/B)L* units include special equipment (insulation, heater sheet,...) to ensure good operation in areas where low ambient temperature can occur together with high humidity conditions. In such conditions the E(D/B)H* models may experience problems with severe ice build-up on the aircooled coil. In case such conditions are expected, the E(D/B)L* must be installed instead. Both E(D/B)L* and E(D/B)H* models have a freeze prevention function using the pump and back up heater to keep the water system safe from freezing in all conditions. In case accidental or intentional power shutdown is likely to happen we recommend to use glycol. (**) only E(D/B)L* Leaving condenser water temperature Booster heater operation only (**) only E(D/B)L* Sanitary mode Outdoor temp. ( CDB) Water temperature sanitary tank (C ) 4TW580-A 8

Monobloc EBLQ0-06AA6V Hydraulic performance - Static pressure drop unit EBLQ0-06AA6V ESP (kpa) I High speed II medium speed ESP: External static pressure Flow: waterflow through the unit Flow (l/min) WARNING. Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrange in the technical specifications. 2. Water quality must be according to EN directive EC 98/8 EC. 4TW5809-2 9