ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Similar documents
ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Central Emergency Lighting Inverter Systems

Spectron LSN (Life Safety Network) Suggested Specifications

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

SECTION POWER SUPPLIES AND DISTRIBUTION

APC BC300 Series 40kW 208/450/480V User Guide

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

Guide Specification Model CTG Automatic Transfer Switch

» EN50171» Lighting» Reliable

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

HIGH BAY APPLICATIONS

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

DGC-1000 DIGITAL GENSET CONTROLLER

FLOAT BATTERY CHARGERS

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

LORAIN CIP 4890/48120 DC Power System

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Excel-EN Conventional Fire Control Panel

LORAIN CSP DC Power System

Power Protection Solutions

DGC-500 DIGITAL GENSET CONTROLLER

DIESEL Engine Fire Pump Controllers Features

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

DS7400Xi Addressable Control/ Communicator

SECTION AUTOMATIC TRANSFER SWITCHES

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Across-the-Line SERIES MP300 Combined Manual and Automatic

CALTECH Pasadena, CA

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ECC-50/100C. Emergency Command Center

SECTION EMERGENCY POWER SYSTEMS

Lumacell Series RSNVII, RSNVIII

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

SAFEPATH Mass Notification System (SPMNS)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Commercial and Light Industrial Fire Alarm Control Panel

CHAPTER 20 SERVICE EQUIPMENT

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ENGINE GENERATORS AND ACCESSORIES

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Soft Start Series MP700 Solid State, Reduced Voltage

SECTION ISOLATED POWER SYSTEMS

NYC Approved Product Series

Installation and Operation Manual

Addressable Fire Alarm Control Panel

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

ACP10 & ACP50 Security Systems

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Bulletin 1608N MiniDySC Dynamic Sag Corrector

LED RETROFIT SOLUTIONS

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

ECC-50/100(E) Emergency Command Center

June 10, 2002 DF C S2424

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PART 4 ELECTRICAL STANDARDS

TrueAlarm Fire Alarm Systems

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Specification/ Data Sheet

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Specification for On-Line UPS Battery Monitoring and Data Management System

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION LOW VOLTAGE LIGHTING CONTROLS

SP40S-D. Kingfisher Company, inc. Features: Description:

Two-Channel Gas Controller

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Autonomous control unit

Transfer Switch Features

Model 17A00 Expansion Enclosure

Variable Frequency Drive SERIES MP800 VFD

SECTION LIGHTING CONTROLS

The EN54 Part 2 & 4 Fire System

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

OPTIMUM APPLIED SYSTEMS,

Transcription:

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING ALSO AVAILABLE FROM MYERS POWER PRODUCTS: ILLUMINATOR SERIES CIII 4.8 kva TO 50 kva THREE PHASE ILLUMINATOR CM 500 VA TO 2000 VA SINGLE PHASE 44 South Commerce Way Bethlehem, PA 18017 Tel: (800) 526-5088 Fax: (610) 868-8686 www.myerspowerproducts.com ELP-0001-BR-0610

THE ILLUMINATOR ILLUMINATOR SERIES IE The Illuminator Series IE is an interruptible lighting inverter. It transfers to inverter mode (battery power) when utility power is interrupted for more than one line cycle. This series is capable of supporting full normally off load. The Series IE is designed for fluorescent, quartz, LED, and incandescent normally on and/or normally off lighting loads and applications that require large normally off (emergency only) lighting loads. ILLUMINATOR SERIES E The Illuminator Series E is an uninterruptible lighting inverter. It transfers to inverter mode (battery power) when utility power is interrupted for less than 1mS. The line inter-active design eliminates excessive transfers to battery power. The Series E is designed for HID lighting loads, mixed HID/incandescent/ quartz/led/fluorescent normally on loads and applications that do not require large normally off (emergency only) loads. H.I.D. Compatible V.T.D. Available Line Interactive Norm. Off Load Capability SERIES E Yes No Yes 20% Maximum of System Capacity SERIES IE No Yes No Full System Capacity APPLICATIONS 911 Facilities Airports Apartment/Condominium Complexes Assisted Living Centers, Nursing Homes Banks, Financial Institutions Casinos City, County, State, Federal Buildings Grocery Stores/Home Center Stores Hospitals Hotel, Motels Industrial Medical Offices Military Complexes Movie/Performing Art Theaters Office Buildings Parking Garages Prisons Race Tracks Railroad, Subway, Bus Stations Religious Facilities Restaurants Retail Department Stores Schools, Colleges, Day Care Centers Shopping Malls Sport Facilities Toll Booths Tunnels and Bridges Designed to work with all electronic power factor corrected ballasts. Central Inverters can eliminate unit equipment in architecturally sensitive applications. Eliminate maintenance costs of individual testing of unit equipment and battery powered ballasts. All tests and diagnostics are performed and recorded automatically. 1

SYSTEM SPECIFICA TIONS SPECIFICATIONS SYSTEM DESIGN FEA TURES FEATURES Industrial Grade Enclosure Battery Fuse User Interface Display Input Breaker Output Distribution Input Terminal Block 76" 47" 3-Point Corbin 60 Locking Latch Front Access Batteries Installation Switch 25" 25" 30" 48" 6.0-16.7kVA Powder-Coat Paint 1.5-5kVA ELECTRONICS MODULE Battery Terminal Block BATTERIES (90 Minutes @ Full Load) 6.0-16.7kVA shown. Power Rating (kva) Power Rating (kw) Number of Batteries Efficiency (@ full load) Voltage (VDC) Audible Noise (dba @ 1m) Current (Amperes) Heat Loss (BTU)/HR Cabinet Dimensions 5 Width Height Depth Weight 90 Minute Batteries INVERTER Fourth generation IGBT-based inverter with dynamic pulse-bypulse current limiting and inrush protection. Short circuit and overload protected by microprocessor and PWM integration for maximum reliability. Total System Weight WAVEFORM Pure PWM sine wave, less than 3% THD with 0.5 leading and 0.5 lagging loads. Microprocessor and crystal controlled. THERMAL PERFORMANCE Bonded fin heat sink technology for maximum thermal performance. Fan energized only on inverter mode which increases reliability and reduces preventative maintenance. 1.5 2.25 3.0 1.5 2.25 3.0 102 153 204 215/ 230/105 235/107 296/135 444/200 592/266 4 6 8 48 72 96 39 38 38 511/230 674/306 827/372 3.75 5.0 6.0 3.75 5.0 6.0 255 340 408 240/109 280/128 605/272 740/330 888/400 1110/500 10 12 15 120 144 180 37 41 40 0/441 1168/525 1715/772 8.0 10.0 12.5 16.7 8.0 10.0 12.5 16.7 544 680 850 1135 640/288 785/353 805/362 885/3 1480/666 1776/800 2220/999 2960/1332 20 24 30 40 240 144 180 240 39 82 82 80 2120/954 2561/1153 3025/1361 38/1730 BATTERY CHARGER Integrated 3 step with equalize, temperature controlled, 24hour recharge for 90 minute system is standard. MODULAR Innovative modular sub-assembly design leads the industry with less than 15 minute MTTR. CONSTRUCTION Enclosure is cold-rolled steel with powder-coated surface. Hinged doors with security 3-point Corbin 60 locking system for easy access and maintenance. BATTERIES Front access, maintenance-free, sealed lead calcium VRLA batteries are standard. Significantly reduces installation and maintenance time and increases safety. SMALL FOOTPRINT 25" (depth) x 30" (wide) 1.5-5kVA, or 25" (depth) x 48" (wide) 6-16.7kVA. CONTROL PANEL Self-testing and self-diagnostics per NFPA and UL standards. Memory logs of over 1525 parameters contained in Test, Event and Fault Logs. Easy to read alpha-numeric display with userfriendly keypad integrates Systems Meter, Alarm, Control and Program functions. 2

SYSTEM DISPLAY FUNCTIONS 3 NOTE: All displayed meter functions match the inverter. SYSTEM OPTIONS E-MAIL/MODEM User can enable/disable and program alarms that will trigger messages to e-mail destinations. User can set up specific alarm events that will alert service or maintenance personnel. The system will transmit monthly and yearly tests per NFPA requirements. Bidirectional communication eases system diagnostics and data retrieval through the RS-232 serial communication port. TIME DELAY Delays retransfer of inverter to continue supplying emergency power to the normally off output for 15 minutes after the return of utility power. OUTPUT CIRCUIT BREAKER Maximum output breakers available: 12 unsupervised (1-pole), 8 supervised (1-pole) for 1.5-5 kva, and 24 unsupervised (1-pole), 15 supervised (1-pole) for 6-16.7 kva. Additional output breakers available on 1.5-5kVA systems (additional 30 pole positions, 42 positions total; enclosure height increases to 62 ). OUTPUT TRIP ALARM An audible and visual alarm activates when an output distribution circuit breaker is open or has tripped. MAINTENANCE BYPASS This device is internally mounted in the system and permits maintenance personnel to easily bypass the inverter and connect directly to the AC utility power. The make before break switch isolates the electronics or inverter system to allow performance of routine maintenance or servicing. REMOTE METER PANEL Allows a second fully functional front meter panel to be mounted external to the inverter up to 150 feet away. (100 cable standard) BATTERY OPTIONS S - BATTERY (Sealed Lead-Calcium) (Standard) A maintenance free, valve regulated lead calcium battery. Constructed with a rugged polypropylene case. Does not require any special room ventilation. 10-year prorated warranty. METER FUNCTIONS AC Voltage Input AC Voltage Output AC Current Output Battery Voltage System Days PROGRAM FUNCTIONS Set Date Set Time Set Month Test Date/Time Set Yearly Test Date/Time Set Load Fault Reduction Setting Battery Current VA Output Inverter Watts Ambient Temperature Inverter Minutes Set Low Battery Alarm Set Near Low Battery Alarm Set Low AC Voltage Alarm Set High AC Voltage Alarm Set Ambient Temperature Alarm CONTROL FUNCTIONS Test Log & Event Log Alarm Log (75 Logs Stored): (75 Logs Stored): Date, Time, Date, Time, Alarm Type Duration, Output Voltage, Test Output Current, Ambient Buzzer On/Off Temperature and Alarms Present SUMMARY FORM C CONTACTS Form C contacts rated at 5 amps maximum at 25OVAC/ 3OVDC. Dry contacts will change state when any system alarm activates. Contacts change state with the following alarms: High/ low battery charger fault, near low battery, low battery, load reduction fault, output overload, high/low AC input volts, high ambient temperature, inverter fault, test failure, and optional circuit breaker trip alarm. FAST CHARGE This is a battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period. NORMALLY OFF OUTPUT (Standard on Series IE) This output circuit is dedicated for emergency-only equipment. Emergency-only equipment operates during power outages and when the system is on battery back up. This option leaves the selective load circuits off during normal utility power conditions. REMOTE SUMMARY ALARM PANEL A wall mountable box containing an audible alarm and light that will activate upon any system alarm with silence switch. INVERTER ON FORM C CONTACT Form C dry contacts that will change state when the inverter transfers to battery operation. STATUS MONITORING CONTACTS Form C dry contacts capable of monitoring system and option statuses (Inverter On, Inverter Off, AC Present, High Temperature, Summary Alarm, System Bypass*, and OTA*) *Requires purchase of Maintenance Bypass and/or Output Trip Alarm options. G - BATTERY (Sealed Lead-Calcium) A maintenance free, long life, valve regulated lead calcium battery. Constructed with a polypropylene jar installed in a steel container. Does not require any special room ventilation. 20-year prorated warranty.

ORDERING GUIDE Example Model Number: 1-E-4-S-BA2007-F-T-S-M-N-2YW SYSTEM TYPE E - Illuminator Series E IE - Illuminator Series IE VOLTAGE (INPUT/OUTPUT) 1 1-120-120 2-120-120/277 3-208-120 4-240-120/240 5-277-120 6-277-277 7-277-277/120 8-208-120/240 9-347-347 A - 208-120/208 Z - Other Voltages KVA/KW 2 1-1.5 2-2.25 3-3.0 4-3.75 5-5.0 6-6.0 7-8.0 8-10.0 9-12.5 10-16.7 BATTERY TYPE S - Standard (VRLA) G - VRLA 20-Year 1) Only single phase voltages available. 2) KVA = KW 3) Standard battery run time is 90 minutes. 4) Normally off loads on Series E cannot exceed 20% of total KVA rating with any combination of H.I.D. Loads. 5) Maximum output breakers available: 12 unsupervised (1-pole), or 8 supervised (1-pole) for 1.5-5 kva, and 24 unsupervised (1- pole), or 18 supervised (1-pole) for 6-16.7 kva. Breakers provided are 20 Amps unless specified otherwise. A 2-pole breaker occupies 2 positions. 6) Maintenance bypass switch is a make before break. 7) Standard one year warranty. 8) Requires Factory Start-up and E-mail/Modem options. This program will provide monitoring of the lighting inverter system by our factory service department. All monthly and yearly system tests will be reviewed by our factory service department for early warning signs of any system malfunction. Any system alarms and monthly/yearly test results will automatically be E-mailed to our service department where corrective action can be taken and while under warranty, if necessary, a factory authorized service technician will be scheduled to complete any necessary repairs. This monitoring program will require a dedicated telephone line. 9) 15 minute retransfer time delay of normally off circuit after return of utility. RUNTIME 3 (Other than 90 minutes) R15-15 Minutes R30-30 Minutes R60-60 Minutes R120-120 Minutes R180-180 Minutes R240-240 Minutes OUTPUT BREAKERS 5 Example: B A 20 07 OUTPUT B - Normally On N - Normally Off 4 VOLTAGE A - 120 B - 208 C - 240 D - 277 Z - Other AMP RATING 10, 15, 20, 25, 30, 40, 50, 60 QUANTITY 01-24 5 (List all circuit breaker requirements separately, ex: BA2007 - NA1001 ) WARRANTY 7 2YW - Factory Start-Up Extended 2-Year Warranty 5YP - 5-Year Preventative Maintenance Plan, Start-Up Included 5YW - 5-Year Extended Electronics Warranty SMP 8 - Service Monitoring Plan OPTIONS A - Remote Summary Alarm Panel C - Status Monitoring Contacts E - E-Mail Modem F - Fast Charge I - Inverter On Dry Contact M - Maintenance Bypass 6 R - Remote Meter Panel S - Summary Fault Form C Contacts T - Output Trip 5 (Supervised) Alarm V - Time Delay 15 min. Z - Seismic Zone 4 ACCESSORIES MOD- Modem EMBP A,6 - External Maintenance Bypass Switch A) Cannot purchase External Maintenance Bypass Switch with Branch Circuit Breaker options. 4

SYSTEM SPECIFICA TIONS SPECIFICATIONS SYSTEM DESIGN FEA TURES FEATURES Industrial Grade Enclosure Battery Fuse User Interface Display Input Breaker Output Distribution Input Terminal Block 76" 47" 3-Point Corbin 60 Locking Latch Front Access Batteries Installation Switch 25" 25" 30" 48" 6.0-16.7kVA Powder-Coat Paint 1.5-5kVA ELECTRONICS MODULE Battery Terminal Block BATTERIES (90 Minutes @ Full Load) 6.0-16.7kVA shown. Power Rating (kva) Power Rating (kw) Number of Batteries Efficiency (@ full load) Voltage (VDC) Audible Noise (dba @ 1m) Current (Amperes) Heat Loss (BTU)/HR Cabinet Dimensions 5 Width Height Depth Weight 90 Minute Batteries INVERTER Fourth generation IGBT-based inverter with dynamic pulse-bypulse current limiting and inrush protection. Short circuit and overload protected by microprocessor and PWM integration for maximum reliability. Total System Weight WAVEFORM Pure PWM sine wave, less than 3% THD with 0.5 leading and 0.5 lagging loads. Microprocessor and crystal controlled. THERMAL PERFORMANCE Bonded fin heat sink technology for maximum thermal performance. Fan energized only on inverter mode which increases reliability and reduces preventative maintenance. 1.5 2.25 3.0 1.5 2.25 3.0 102 153 204 215/ 230/105 235/107 296/135 444/200 592/266 4 6 8 48 72 96 39 38 38 511/230 674/306 827/372 3.75 5.0 6.0 3.75 5.0 6.0 255 340 408 240/109 280/128 605/272 740/330 888/400 1110/500 10 12 15 120 144 180 37 41 40 0/441 1168/525 1715/772 8.0 10.0 12.5 16.7 8.0 10.0 12.5 16.7 544 680 850 1135 640/288 785/353 805/362 885/3 1480/666 1776/800 2220/999 2960/1332 20 24 30 40 240 144 180 240 39 82 82 80 2120/954 2561/1153 3025/1361 38/1730 BATTERY CHARGER Integrated 3 step with equalize, temperature controlled, 24hour recharge for 90 minute system is standard. MODULAR Innovative modular sub-assembly design leads the industry with less than 15 minute MTTR. CONSTRUCTION Enclosure is cold-rolled steel with powder-coated surface. Hinged doors with security 3-point Corbin 60 locking system for easy access and maintenance. BATTERIES Front access, maintenance-free, sealed lead calcium VRLA batteries are standard. Significantly reduces installation and maintenance time and increases safety. SMALL FOOTPRINT 25" (depth) x 30" (wide) 1.5-5kVA, or 25" (depth) x 48" (wide) 6-16.7kVA. CONTROL PANEL Self-testing and self-diagnostics per NFPA and UL standards. Memory logs of over 1525 parameters contained in Test, Event and Fault Logs. Easy to read alpha-numeric display with userfriendly keypad integrates Systems Meter, Alarm, Control and Program functions. 2

SYSTEM SPECIFICATIONS INPUT OUTPUT Voltage 120 or 277VAC 1-phase 2-wire +10% -20% on Series E, and +10% -15% on Series IE. Contact factory for all other voltages. Input Power Walk-in Limiting inrush current to less than 125% of full rated load. Input Frequency 60Hz, +/- 3%. Synchronizing Slew Rate 1Hz per second nominal. Protection Input Circuit Breaker. AIC Rating 65k RMS symmetrical ampere short-circuit rating. Power Factor 0.5 lag/lead. Voltage 120 or 277VAC 1-phase 2-wire. Contact factory for all other voltages. Static Voltage Load current change +/-2%, battery discharge +/-12.5% Dynamic Voltage +/- 2% for +/-25% load step change, +/-3% for a 50% load step change, recovery within 3 cycles. Harmonic Distortion < 3% THD for linear load. Overload Fuse protected. Output Frequency 60Hz +/- 0.05Hz during emergency mode. Load Power Factor 0.5 lag to 0.5 lead. Inverter Overload 115% for 10 minutes. 280% for 12 line cycles. Protection Optional Distribution Circuit Breakers. BATTERY Type Charger Protection Disconnect Optional Runtimes Valve-regulated sealed lead-calcium; Consult factory for additional battery types. Microprocessor controlled for various battery types and temperature compensating (recharge per UL924 spec). Automatic low-battery disconnect; automatic restart upon utility return. Fuse Extended runtimes available. Consult factory for additional information. ENVIRONMENTAL Operating Temperature 20 to 30 C (68 to 86 F) per UL 924. Storage Temperature -20 to 70 C (-4 to 158 F) (electronics only). Relative Humidity < 95% (non-condensing) GENERAL Efficiency Design Output Circuits Generator Input Control Panel Metering Alarms Communications Manual Maintenance Bypass Alarm Contacts Warranty Factory Start-up 5-Year Maintenance Plan % while on utility. PWM inverter type utilizing IGBT technology with 2mS transfer time on Series E and 50mS on Series IE. Series E - Normally On Circuit standard; Normally Off Circuit optional. Series IE - Normally On and Normally Off Circuits standard. Compatible with generators. Microprocessor controlled 4 x 20-character vacuum fluorescent display with touchpad controls/functions scrolling system status. Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage. High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature, Inverter Fault, Output Fault, Test Failure, and Optional Circuit Breaker Trip. RS-232 port (DB9 standard). E-mail/fax modem optional. Optional internal or optional external without internal distribution breakers. Optional Summary Alarm Form "C" Contacts. 1 year standard warranty includes all parts, labor, & travel expenses within 48 contiguous states. 10 years prorated warranty on batteries. Extended warranties, preventative maintenance and customized service plans are available. Purchase factory start-up & receive 1 additional year of electronics warranty. Purchase 5-year preventative maintenance plan & receive free factory start-up. PHYSICAL Cabinet Freestanding NEMA Type 1. Cooling Forced Air, during emergency mode. Cable Entry Top or sides on 1.5-5kVA; Sides only on 6-16.7kVA. Access Front. 6

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING ALSO AVAILABLE FROM MYERS POWER PRODUCTS: ILLUMINATOR SERIES CIII 4.8 kva TO 50 kva THREE PHASE ILLUMINATOR CM 500 VA TO 2000 VA SINGLE PHASE ELP-0001-BR-0610