Dust Explosion Protection Consistent with North American Practice

Similar documents
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Combustible Dusts What do I do???

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

1. GENERAL TECHNICAL INFORMATION

Technical Data. Dimensions

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Understanding Hazardous Locations Concepts

ATEX, NOMENCLATURE AND CODING

PEPPERL+FUCHS GmbH

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Technical Data. Dimensions

Inductive slot sensor

Explosion-protected actuator Page 259 of 292

ATEX, NOMENCLATURE AND CODING

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Technical Data. Dimensions

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INSTRUCTION MANUAL (ATEX / IECEx)

Beamex Calibration White Paper. Calibration in hazardous areas

UL HAZARDOUS LOCATIONS SERVICES

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

MICROpeL 75 Combustible Gas Sensor Part Number: PM

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Overview of Hazardous Locations as They Relate to Solenoid Valves

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Drive systems for the chemical, oil and gas industry. Electric drives and systems

INSTRUCTION & SERVICE MANUAL

manual addendum DELPHI Ex

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Beamex. Calibration White Paper. Calibration in hazardous areas

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Rosemount 752 Fieldbus Remote Indicator

Technical Data. General specifications. Rated operating distance s n 5 mm

Guide to Explosion Protection and Plant Safety

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

INTERNATIONAL STANDARD

VSD AND SS DRIVING ATEX MOTORS February 2014

ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing motors for hazardous areas.

Guide for hazardous areas

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certificate of Compliance


HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

INSTRUCTION MANUAL (ATEX / IECEx)

S T R I T T & P R I E B E I N C.

4) Intrinsic Safety Certification

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Liquid Ring Vacuum Pumps, Compressors and Systems

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Annubar Flowmeter Series

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

ESSENTIAL EXPLOSION PROTECTION

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Certificate of Compliance

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

BINDER Scientific Product Catalog

Main switch current K: with main switch (optional)

IECEx Certificate of Conformity

C 319/6 Official Journal of the European Union

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Survey of electrical equipment installed in hazardous areas on tankers

Certification Supplement Manual

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Official Journal of the European Union

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Certification Supplement Manual

Integrated Solutions Low Voltage Systems

IRceL CH4 Methane (CH 4

IECEx Certificate of Conformity

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Apparatus Groups are sometimes referred to, erroneously, as Gas Groups.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Model 144H. Product Data Sheet , Rev DB February Content

OPTIBAR DP 7060 Supplementary Instructions

IECEx Certificate of Conformity

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Guide to Hazardous Location Approvals:

IECEx Certificate of Conformity

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Transcription:

Legislation, Standards and Technology Dust Explosion Protection Consistent with North American Practice now to EN 61241-1 as an option by Helmut Greiner Figure 1: ADM Grain Mill in Kansas City, USA after the explosion on 10 April 1979 (source: R. W. Schoeff, Kansas State University) The new European Standard EN 61241-1 [1] now provides an option referred to as Practice B which has already been in use in North America for seven decades. This report provides some background information on how this Standard came into being and describes individual details of the design and testing requirements and acceptance criteria. Practice B may be of interest as an alternative to Practice A for > manufacturers who wish to or have to supply this method of dust explosion protection to North America and > repair and servicing companies who are obliged to restore the original condition on explosion protected apparatus. Beyond this, users will be interested in the real meaning of the letters A and B for example, within the framework of a project.

Ex-Magazine 2005 50 51 1 How this Standard came into being Explosions caused by grain dust (Figure 1) were relatively frequent in the USA, as shown by the statistics for the years 1980 tru 1990 (Figure 2). In the decade under consideration here there were around 200 serious incidents involving of a total of 54 persons and 256 injuries, and also causing damage to property amounting to approx. 165 million dollars. Efforts to prevent such incidents, even as early as 1929, led to the first edition of Standard UL 674 (A) Electric motors and generators for use in hazardous locations, Class II, Groups E, F and G. When IEC standardisation work in relation to dust explosion protection began (around 1980), North American experts were able to point out the 50 years of experience they already had at the time with UL Standard 674 (A). Consequently, it was necessary then to standardise two Practices which had an equivalent technical-safety level but which differed fundamentally (Table 1) to the first edition of IEC 1241-1-1: 1993. When IEC 1241-1-1 was adopted as EN 50281-1-1: 1998, it was possible to eliminate Practice B since the work was being conducted solely at the European CENELEC level. The new Standards for type of protection td (IEC 61241-1 and EN 61241-1) were, however, elaborated on in parallel voting procedure between IEC and CENELEC and thus, once again contained a consensus with both Practices A and B. Figure 2: Number of explosions involving food and fodder dusts, recorded by the >Federal Grain Inspection Service< of the US Department of Agriculture Praxis A Table 1: Comparison values for Practices A und B in accordance with IEC and EN 61241-1 Praxis B Basic Standards EN 1127 UL 674 EN 60529 CSA C 222 No. 145 Dust layer during temperature test no yes Ignition temperature referred to dust layer thickness 5 mm 12.5 mm (1/2 Zoll) Criteria for thightness IP6X/IP5X Gap at sealing joint Test dust particle size < 75 µm < 150 µm Design requirements no special

Dust Explosion Protection Consistent with North American Practice 2 Requirements applicable to joint dimensions The joint seals in the case of Practice B are comparable with the design principle of Flameproof Enclosures without being targeted at or tested for avoidance of flame transmission (explosion propagation). Certain values are outlined in extract form below and where possible compared with the requirements, as in the case of Flame proof Enclosures (Figures 3 to 6), using the original diagrams of the Standard from US sources. G W 5. Plaine joint Plaine joint at a contact surface EEx d Verfahren B Width of joint 5 mm 22 mm Max. clearence G 0.05 mm 0.22 mm

Ex-Zeitschrift 2005 52 53 Figure 7: Comparison of the permitted diametrical clearances in the case of joint width 25 mm for Explosion Groups I, IIA, IIB and IIC in the case of type of protection EEx d (Flameproof Enclosures) with the particle sizes of ignitable dusts and with the gap in accordance with IEC and EN 61241-1 Practice B (td B 21 in the case of Zones 21 and 22) 3 Testing dust-tightness Breathing of a housing as the result of the heating cycle is simulated in the IP test in accordance with EN 60529 [2], applied in the case of Practice A, by generating an artificial partial vacuum in the housing that may be up to twice the natural partial vacuum [3]. In the case of Practice B, the partial vacuum is produced by heating during operation at rated power and then cooling. Testing with heat cycle 1) The apparatus shall be mounted in a test chamber of sufficient size in order to permit free circulation of the dust-air mixture around the sample (Figure 8) during the test period. A mixture of suitable dust and air shall be circulated by auxiliary equipment and introduced continuously into the test chamber during the entire test period. The particle size of the dust shall be such that it passes through a No. 100 ASTM sieve (approx. mesh width 0.15 mm) with approx. 22 % passes through a No.200 ASTM sieve (mesh width approx. 0.075 mm). 2) Quote from EN 61241-1:»For the test specified above, the apparatus shall be operated at rated load until maximum temperatures are reached and then disconnected from the supply until it has cooled to approximately room temperature. The number of cycles of heating and cooling shall be at least six and shall last for a minimum of 30 hours«. Acceptance criteria The dust is gently removed by sweeping after the test. Under no circumstances shall the dust be removed by an air blast or vacuum cleaning. The housing is then opened and checked thoroughly for any dust which has penetrated. No visible dust may have penetrated the housing. Dust in joints may not be assessed as a fault. Restricted sealing effectiveness of gaps or diametrical clearances Practical experience to the effect that gaps or diametrical clearances without additional sealants have only a restricted Figure 8: Testing dust-tightness by six heating/cooling cycles in accordance with Practice B in IEC and EN 60241-1 (Source: Danfoss Bauer on the occasion of a previous UL acceptance testing procedure)

Dust Explosion Protection Consistent with North American Practice sealing effectiveness (Figures 9 and 10) was confirmed in a fundamental series of tests. The complete series of tests can be found in [3]. Figure 3 and the acceptance testing conditions confirm that even Standard UL 674 does not fully rely on the sealing effectiveness of gaps or diametrical clearances. 4 Thermal tests The basic conditions for the temperature rise test are defined in IEC and EN 61241-0 for the two Practices A and B: these have been adopted from EN 60079-0 for gas explosion protected apparatus. However, in the case of Practice B, there is an additional requirement to the effect that the apparatus must be covered with the maximum dust quantity remaining on it. Alternatively, a 12.5 mm thick layer of dust paste may be applied to the top of the apparatus in order to simulate the dust layer. This paste should consist of the following percentages-by-weight: 45 % dust (e.g. wheatmeal flour) and 55 % water. The temperature value should be measured after the paste has dried (Figure 11). 5 Marking The two examples of marking below in the case of Practices A and B are based on Section 9 of IEC and EN 61241-1. The difference between the Practices results from the letters prefixed for the Zone in this case Zone 21. Unfortunately, the specifically European stipulations were not allowed for in the Standards which originated on the basis of a parallel voting procedure. These result from EU Directive ATEX 94/9/EC. CENELEC TC 31, responsible for the essential regulations for marking, unfortunately dealt with uniform definitions only at a very late point. Figure 9: Adjustment of a gap (e.g. 0.5 mm) between the metallically bare faces of terminal box and cover ABC company Serial-No. 987654 N.A. 01/99999 Ex td A21 T120 C V A Hz kw r/min Type RST Figure 11: Testing temperature rise with dust covering on the upper side in the case of Practice B (dust blanket test) in accordance with IEC and EN 61241-1 (source: Danfoss Bauer on the occasion of an earlier UL acceptance test) Bibliography ABC company Serial-No. 123456 N.A. 01/99999 Ex td B21 T170 C V A Hz kw r/min Figure 12: Markings Type KLM Figure 10: Test result with the gap reduced to 0.05 mm, test period approx. 200 minutes 1 EN 60241-1: Electrical apparatus for use in the presence of combustible dust, Part 1: Protection by enclosures >td< 2 EN 60529/: Degrees of protection by enclosures (IP Code) 3 Greiner, H.: IP degrees of protection Publication SD 101E by Danfoss Bauer Gmbh