The New Lux-Ray LED Emergency Lighting

Similar documents
Distributor Select LED Families

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

NYC Approved Product Series

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

NEMA-4X Series. Certified for Harsh Environment Applications

A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB

Power (max) Current (max)

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

Architectural / led luminaires

Exit/Emergency Lighting Guide

Nightfall. led emergency egress lighting

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Project. Comments. Prepared by

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

Pictogram Exit Signs Catalogue

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

IOTA Exit Signs. IOTA Emergency Fixtures

Emergency Lighting. Product Guide LED. The right source for the. right light

PRODUCT OFFERING QUALITY VALUE VERSATILITY

Hospitality. Emergency Lighting

High Lux Performance White LED MR16 Lamp

LED FIXTURE CATALOG. Shining light into the future

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Enhancing the Lighting Experience

Outdoor Emergency Lighting Application Guide

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

CHINESE NEW YEAR DEADLINE SOLUTIONS

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Catalog Number. Notes

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

BACKUP BATTERY INSTALLATION INSTRUCTIONS

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Dublin airport - Dublin, Ireland

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Bdl60u Fluorescent Emergency Ballast

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

For more information, please visit 3-form.com or call

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

New LED Product Offerings

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

CDL8 LED Architectural

12 inches to 120 inches

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

SURE-LITES. LEM PathLinx Series. LED Emergency Lighting

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

LIGHT CHANNEL 45 COMPLETE FIXTURE

Under Cabinet Lighting

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

EHT/EHTD. Electromechanical Closer-Holder Release Devices

5.0. Photoelectric Sensors. Technical Reference. Introduction

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

LINKABLE UNDERCABINET

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

LHBXD LED Linear High Bay

SURFACE Spec Guide. up to 105 lm/w performance

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Evolve LED Garage Light

CENTENNIAL BRASS 12V PRODUCT LINE

Welcome. Page 2. Iconic LED, LLC 1806 W Pinhook Rd. Lafayette, LA Main (337)

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

LUX PENDANT DIRECT/INDIRECT

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Altman Lighting Spectra Cyc UV 50 Specification

Applications. Standard Materials

THE RLC SERIES. NEW 2018 RESIDENTIAL AND LITE COMMERCIAL LINE SELENE BEACON DYAD NORTHSTAR CELESTIAL. eran industrial.

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

The Urban Farmer Store

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

FPLHB - Fidelux Premier Linear Highbay

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

THE UNITED LIGHTING GROUP

RECESSED Spec Guide. up to 111 lm/w performance

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Pioneering Petroleum Canopy Lighting Since 1976

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

L305. tambient LED. for single workstations. All-in-one task/ambient luminaire, slim profile outrigger design for open office workstations with VDTs

Transcription:

ON THE PROJECT, ON THE SHELF, ON THE JOB The New Lux-Ray LED Emergency Lighting RUGGED. VERSATILE. SOPHISTICATED

MINIATURIZATION The New Lux-Ray LED Emergency Lighting For first-class performance in emergency lighting, the Lux-Ray LED illuminates a 40-70 path of egress with a wide beam, and consumes less than 5W in stand-by mode. Optional dual-mode illumination provides lighting during power outages and in normal conditions. LED technology miniaturizes emergency lighting to be more environmentally friendly by providing more illumination with a smaller unit. The high-performance Lux-Ray LED reduces energy consumption, requires fewer units to install, and uses a compact, Lead-free & Cadmium-free battery. Photometry Performance Whether installed indoors or outdoors, with spacing measurements for a single unit or between two units center-tocenter, the Lux-Ray LED Series delivers a stable and consistent illumination making it easy to specify in a wide range of applications. The outstanding spacing of illumination ranges from 50 to 70 feet for standard units (wide beam) and from 40 to 50 feet with the forward-throw beam option. Average of 1 foot-candle Table A: Spacing for NFPA101 (average = 1fc, see Note) Model Type Mouting Height Width X Lenght (Ft) SINGLE UNIT CENTER-TO-CENTER Standard 9 6 X 50 6 X 50 With option -H 11 6 X 60 6 X 60 3 X 70 With option -FT 12 6 X 40 With option -FTH 15 6 X 50 Indoor reflectance: 80/50/20 and 10-ft wide corridor. Outdoor reflectance: 0/30/10 Note: The illumination level meets ALL the requirements of the Life Safety Code (NFPA 101): 1) Average of 1 foot-candle or more 2) Minimum at any point of 0.1 foot-candle or more 3) Maximum-to-minimum illumination uniformity ratio of 40:1 or less Minimum of 1 foot-candle Table B: Spacing for minimum illumination = 1fc model type mouting height Width x lenght (ft) single unit center-to-center Standard 9 4 x 28 4 x 32 With option -H 11 4 x 32 4 x 40 With option -FT 12 4 x 22 With option -FTH 15 4 x 27 Max./min. uniformity ratio less than 3:1 9 50 28 6 Wide Beam (Standard) 22 40 12 Forward Throw (Optional) 6

T H R O U G H Remote Control Patent-Pending Emergency Lighting Normal lighting with switch & dimming Mounting Wall Mount 1/2 rigid conduit entry provision on the top of the unit U niversal knock-outs to mount to any standard 4 junction box P atent-pending design for easy installation: wall-mount back-plate includes electrical wire box with snap-on connector Product is shown

at actual size T E C H N O L O G Y Compact, Lead-free & Cadmium-free Nickel-Metal Hydride battery AC quick connect snaps on to the back cover providing energy to the unit in a more compact version than the conventional model Printed Circuit Board with micro-controller driven battery charger and LED driver Colors Off-white Platinum Gray Emergency Lighting Transformer Normal Lighting Transformer Integrated head sink & LED engine support Dark Bronze Patent-Pending cross-beam LED engine with 4 LEDs and individual collimators Clear, High Impact, UV-Resistant (3 X 1.5 ) Polycarbonate lens) Black

NEMA-3R Patent-Pending Lux-Ray LED Series The Lux-Ray LED Series represents a two-in-one solution of accent lighting and emergency lighting for indoor or outdoor architectural spaces. Equipped with a patent-pending light engine (4 LED lamps with redundant connections and offers very wide beam), the Lux-Ray LED brings first-class performance in emergency lighting (40 to 70 feet of illuminated path of egress) and consumes less than 5W in stand-by mode. With generous accent lighting providing up to 640 lumens, the Lux-Ray LED is available with several options like: photo-switch for dusk-to-dawn operation and infrared remote control. Designed and UL listed for wet and damp locations; optional cold-weather package (-40 F/-40 C). Mounting Die-Cast aluminum housing, available in four finishes: dark bronze, off-white, black, and platinum gray Nema-3R rated for indoor / outdoors wet and Damp locations: 0-40 C (32-104 F) Wall-mount installation on various junction boxes or via rigid conduit Patent-pending design for easy installation: wall-mount back-plate includes electrical wire box with snap-on connector Patent pending light engine: four power LEDs with redundant connections and very wide beam Clear polycarbonate lens of reduced size (3 X 1.5 ), shockabsorbent and UV-resistant Battery: environmentally friendly high-temperature rated, Nickel-Metal Hydride technology Power consumption in stand-by: less than 5W Optional self-test and diagnostic functions, operated by micro-controller 5-year limited warranty Optional Features Cold-weather: -40 F / -40 C Forward-throw light distribution, for applications of outdoor exit discharge (OSHA 1910.36) High-lumen output: 25 to 50% additional level of illumination compare to the regular unit Dual-mode operation: normal lighting and/or emergency lighting with separate AC inputs Photo-switch: dusk-to-dawn control of normal lighting Remote test: infrared remote control (keypad ordered separately) Time delay: 5, 10, 15 minutes Dimensions Dimensions are approximate and subject to change. 3 [7.5 cm] 6-5/8 [16.8cm] 3 [7.5 cm] Power Consumption Chart 9-1/2 [24 cm] Window for photo-switch (optional) AC SPECS: 120/277VAC Model Type Normal lighting Emergency lighting 6-12VDC remote Current (max) Power Current Power (max) (max) (max) Power (max) AC, 2AC, ACDC, DC 0.12/0.08A 12W 0.11/0.08A 12W 8W AC, 2AC, ACDC, 0.18/0.11A 18W 0.18/0.11A 18W 14W DC, -H ACSD, SD, SD-H 0.12/0.06A 12W 0.05/0.02A 5W n/a* SD-CW - - 0.15/0.07A 16W ACSD-CWP, -CWRC n/r* 0.22/0.10A 24W *Note: Only unswitched AC input; normal lighting with photo-switch or remote control How to Order Battery Unit Color Series Model Options B= Black BZ= Dark bronze OW= Off-white PG= Platinum gray LUX= Lux-Ray LED SD= Self-Powered & diagnostic (0 50 C) ACSD= Dual-mode AC / Self-Powered (0 40 C) -CW= Cold weather (-40 30 C; N/A with option -H) -D1= Time delay: 5 minutes -D2= Time delay: 10 minutes -D3= Time delay: 15 minutes Example: BZLUXACSD-RC -FT= Forward throw lighting -H= High lumen output (max. 30 C; model SD only) -P= Photo-switch, normal lighting (ACSD only) -RC= Remote control - infrared* * Remote control keypad (TB-RC1-E) ordered separately Remote Fixture Color Series Model [-40 C... +50 C (-40 F... +122 F)] Options B= Black BZ= Dark bronze OW= Off-white PG= Platinum gray LUX= Lux-Ray LED AC= AC-only ACDC= AC/6-12VDC remote DC= 6-12VDC remote fixture 2AC= AC-only two circuits: 120/120 or 277/277V -FT= Forward throw lighting -H= High lumen output (-40 30 C) -P= Photo-switch, normal lighting (AC, ACDC only) -RC= Remote control - infrared* (AC, ACDC only) * Remote control keypad (TB-RC1-E) ordered separately Example: BZLUXDC-FTH

ON THE PROJECT, ON THE SHELF, ON THE JOB www.emergi-lite.com All information and specifications contained in this flyer are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this flyer may vary from actual products. 2013. Thomas & Betts Limited. All rights reserved. Printed in Canada 04/13/4500. Order no. EL-LUXRAYFLYER-US.