Fire Alarm System Inspection and Testing Report

Similar documents
EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

Unified Fire Authority - Fire Prevention Bureau

INSPECTION AND TESTING FORM

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Fire Alarm Testing and Inspection Report

FIRE ALARM SYSTEM INSPECTION

Fire Alarm System Fundamentals

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Florida Building Code 2010

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Functional Performance Test

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

The 2013 National Fire Alarm and Signaling Code

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

Fire Alarm and Life Safety System Inspection Certificate

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Ventura County Community College District 761 E. Daily Drive, West Stanley Avenue, St. 200, Camarillo, CA Purchasing Department

Fire Alarm and Life Safety System Inspection Certificate

2018 NICET Code Transition Changes

Bold items are particular to the City of Euless

NFPA Changes

NFPA 72 Code Changes vs 2013

Fire Alarm and Life Safety System Inspection Certificate

SP40S-D. Kingfisher Company, inc. Features: Description:

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Fire Alarm and Life Safety System Inspection Certificate

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Questions/Comments for Richard Roux from Webinar on 7/11/13

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

System Test Report CLEAN AGENT

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

1.3 REFERENCE STANDARDS

OKLAHOMA STATE UNIVERSITY

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

Applying Performance-based Fire Alarm System Design Part 4

Changes in NFPA

Fire Alarm and Life Safety System Inspection Certificate

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

ECC-50/100C. Emergency Command Center

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Advanced Fire Alarm Systems Training Program Outline (5 Day)

Full Service Central Station Fire Alarm Listing Evaluation

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

17 Fire Alarm Systems Standards 354th Civil Engineering Squadron OPR: CES/CEOFA ISSUED: 12 September 2017 EIELSON AIR FORCE BASE DESIGN GUIDELINES

ECC-50/100(E) Emergency Command Center

SAFEPATH Mass Notification System (SPMNS)

SECTION FIRE ALARM INTEGRATED AUDIO VISUAL EMERGENCY COMMUNICATION SYSTEM

July 14, 1999 DF C-100.

1. The fire detection and alarm system (including the conduit) shall be a separate bid item and not part of the general electrical contract.

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.


SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

NFPA Changes

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Facilities Management

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SAFEPATH SAFEPATH. Emergency communications system

EIELSON AFB FIRE SYSTEMS STANDARDS 354 TH CIVIL ENGINEER SQUADRON ALARM MAINTENANCE SHOP

2019 COURSE CATALOG (rev )

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

VSC Fire & Security, Inc.

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

FIRE & LIFE SAFTEY STANDARD

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Specification/ Data Sheet

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Environmental Health & Safety

SECTION : FIRE ALARM & DETECTION SYSTEMS

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Transcription:

Fire Alarm System and ing Report Date of : Time of : 1. PROPERTY INFORMATION: Name of Property: Address: of property: Occupancy Type: Name of property representative: Address: Phone: Fax: E-mail: Local authority having jurisdiction over this property: Phone: Fax: E-mail: 2. TESTING CONTRACTOR INFORMATION: ing organization for this equipment: Address: Phone: Fax: E-mail: Service technician or tester: Qualifications of technician or tester: A contract in accordance with NFPA 72-2010, 14.2.2.3 is in effect as of: Contract expires: Contract number: frequency: Monitoring organization for this equipment: Address: Phone: Fax: E-mail: Entity where alarms are re-transmitted: Phone: 3. TYPE OF SYSTEM OR SERVICE Fire alarm system (non-voice) Fire alarm with in-building fire emergency voice alarm communication system (EVACS) Mass notification system (MNS) Combination system, with the following components: Fire alarm EVACS MNS Two-way, in-building, emergency communication : NFPA 72 edition used to conduct this test: Additional description of system:

3.1 Control Unit Manufacturer: Model: 3.2 Mass Notification System System Type: In-building MNS combination In-building MNS stand alone Wide-area MNS Distributed recipient MNS : System Features: Comb. fire alarm/mns MNS/ACU only Wide-area MNS to alerting interface Local operating console (LOC) Direct recipient MNS (DRMNS) Wide-area MNS to DRMNS interface Wide-area MNS to high-power speaker array (HPSA) interface In-building MNS to wide-area MNS interface : 3.3 System Documentation An owner s manual, a copy of the manufacturer s instructions, a written sequence of operation, and a copy of the record drawings are stored on-site, at the following location: 3.4 System Software This system does not have alterable site-specific software Software revision number: Last updated: A copy of the site-specific software is stored on-site, at the following location: 4. SYSTEM POWER 4.1 Control Unit Input voltage of control panel: Control panel amps: Location of generator: This system does not have a generator Location of fuel storage: Type of fuel: Equipment powered by an UPS system: This system does not have an UPS Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: Battery locations: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 2

4.2 In-Building Fire Emergency Voice Alarm Communication System or Mass Notification System This system does not have an EVACS or MNS Input voltage of EVACS or MNS panel: EVACS or MNS panel amps: Location of generator: This system does not have a generator Location of fuel storage: Type of fuel: Equipment powered by an UPS system: This system does not have an UPS Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: Battery locations: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: Batteries are marked with date of manufacturer 4.3 Notification Appliance Circuit (NAC) Extender Panels This system does not have NAC panels Input voltage of NAC panel: NAC panel amps: Location of generator: This system does not have a generator Location of fuel storage: Type of fuel: Equipment powered by an UPS system: This system does not have an UPS Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: Battery locations: Type: Nominal voltage: Amp/hour rating: Calculated capacity of batteries to drive the system: Batteries are marked with date of manufacturer 5. ANNUNCIATORS Location and of Annunciators Annunciator 1: Annunciator 2: Annunciator 3: Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 3

6. NOTIFICATIONS MADE PRIOR TO TESTING Monitoring organization contact: Time: Building management contact: Time: Building occupants contact: Time: Authority having jurisdiction contact: Time: Other, if required contact: Time: 7. TESTING RESULTS Control Unit and Related Equipment Control unit Lamps/LEDs/LCDs Fuses Trouble signals Disconnect switches Ground-fault monitoring Supervision Local annunciator Remote annunciator NAC panels Isolation modules Control Unit Power Supplies 120-volt power Generator or UPS Battery condition Load voltage Discharge test Charger test In-Building Fire Emergency Voice Alarm Communications Equipment Control unit Lamps/LEDs/LCDs Fuses Primary power supply Secondary power supply Trouble signals Disconnect switches Ground-fault monitoring Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 4

Panel supervision System performance Sound pressure levels Occupied Yes No Ambient dba Alarm dba System intelligibility CSI STI NAC Panels Lamps/LEDs/LCDs Fuses Primary power supply Secondary power supply Trouble signals Ground-fault monitoring Panel supervision Provide a complete inventory of all NAC panels tested. Mass Notification Equipment test Rest/power down test Fuses Primary power supply UPS power test Trouble signals Disconnect switches Ground-fault monitoring CCU security mechanism Prerecorded message content Prerecorded message activation Software backup performed backup software Fire alarm to MNF interface MNS to fire alarm interface In-building MNS to wide-area MNS MNS to direct recipient MNS Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 5

Sound pressure levels Occupied Yes No Ambient dba Alarm dba System intelligibility CSI STI Two-Way Communications Equipment Phone handsets Phone jacks Off-hook indicator Call-in signal System performance System audibility System intelligibility Radio communications enhancement system Area of refuge communication system Elevator emergency communication system Combination Systems Fire extinguishment monitoring devices/system Carbon monoxide detector/system Combination fire/security system Special Hazard Systems (specify) Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 6

Emergency Communication Systems Pass Fail Simulated operation Monitored Systems Ensure pre-discharge notification appliances of special hazard systems are not over- ridden by the MNS. See NFPA 72-2010, 24.4.1.7.1 Engine-driven generator Fire pump Special suppression sys Auxiliary Functions (Interface Relays) Door-release devices Fan shutdown Kitchen hood suppression Elevator recall Magnetic locks Fire pump Smoke dampers Clean agent suppression Dry-pipe/Pre-action Overhead fire doors Elevator shunt trip MNS over-ride of FAS Provide a complete inventory of all devices tested. Alarm Initiating Devices Device test result sheet attached listing all devices tested and the results of the testing Supervisory Alarm Initiating Devices Device test result sheet attached listing all devices tested and the results of the testing Alarm Notification Appliances Appliance test result sheet attached listing all appliances tested and the results of the testing Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 7

Supervisory Station Monitoring Yes No Time Alarm signal Alarm restoration Trouble signal Trouble restoration Supervisory signal Supervisory restoration 8. NOTIFICATIONS THAT TESTING IS COMPLETE Monitoring organization contact: Time: Building management contact: Time: Building occupants contact: Time: Authority having jurisdiction contact: Time: Other, if required contact: Time: 9. SYSTEM RESTORED TO NORMAL OPERATION Date: Time: 10. CERTIFICATION Inspector Certification: This system, as specified herein, has been inspected and tested according to NFPA 72-2010 standards cited herein. Signed: Printed Name: Date: Organization: Title: Phone: Acceptance by Owner s Representative: The undersigned has a service contract for this system in effect as of the date shown below. Signed: Printed Name: Date: Organization: Title: Phone: This form is based on Figure 14.6.2.4 of NFPA 72-2010. Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 8

DEVICE TEST RESULTS Device Type Address Location Results Date Make as many copies of this page as necessary to provide a complete inventory of all components of the fire alarm system. Keyes Life Safety Compliance, LLC www.keyeslifesafey.com Page 9