QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Similar documents
Blue-flame Detectors

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

Infrared Flame Detectors

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame detector. Building Technologies Division Infrastructure & Cities Sector

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

QRA10... QRA53... QRA55...

Infrared Flame Detectors

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

QRA10... QRA53... QRA55...

LAE10 LFE10. Use. Series 02

RAR... Photocell Detectors. Building Technologies Division

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

QRA10... QRA53... QRA55...

Oil Burner Controls LMO24... LMO44...

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

UV Flame Supervision System

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

LGA... Gas Burner Controls. Building Technologies Division

Burner Management System

Oil Burner Controls LOA3... Building Technologies Division

QRA10... QRA53... QRA55...

C Note! LGI16... Burner Controls. Building Technologies

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Basic unit with integrated air-fuel ratio control for forced draft burners

Burner Management System

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

Burner Management System

Heating Element. Building Technologies HVAC Products

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Burner controls. Building Technologies HVAC Products

Building Technologies Division

Gas Burner Controls. Building Technologies HVAC Products

Burner Controls. Building Technologies HVAC Products

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

LFL Series Burner Flame Safeguard Control

for relative humidity and temperature

UV - flame detector dual fuel burners for intermittent burner operations

for relative humidity and temperature

EUROBOX SERIES TYPES CM... SM... MM...

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Use. The burner controls are certified to EN 230 and EN 298.

Room Air Quality Sensors

for relative humidity and temperature with calibration certificates

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

EUROBOX SERIES TYPES CM...N SM...N MM...N

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

MICROFLAT SERIES TYPES C.../U T X

Room Temperature Controller

EUROFLAT SERIES TYPES C... S... M...

Product Range Overview

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Duct Air Quality Sensors

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Silicon UVAB Sensor E xxx

Flame detector FD 2011 / FD 2012

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room Temperature Sensors

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Building Technologies Division

COMPACT FLAME CONTROLLER CFC 100

PRELIMINARY EDITION

MMG Gas burner safety control

Description Control Box, type LOA 24 Control Box, type LOA 26 Control Box, type LMO Β2/C2 Control Box, type LMO B2 Control Box, type

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Room air quality sensors

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Use. Functions. Key function. Other functions

CATALOGUE PRODUITS - CSA - CSI - CSM - CSS - CSS2 - P16 - P19 - P20 - P25 - UV DETECTOR

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Duct Temperature Sensors

Forced draught gas burner

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

DATASHEET. Burner control unit FDA 601x

COMPACT FLAME CONTROLLER CFC 1000

Building Technologies

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

COMPACT FLAME CONTROLLER CFC 2000

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

QUICKTRONIC INTELLIGENT QTi (DALI) DIM

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Transcription:

7 716 QRC1... for frontal illumination Blue-flame Detectors QRC1... for lateral illumination QRC1... Blue-flame detectors for the supervision of ue- or yellow-burning oil or gas flames. Blue-flame detectors are used primarily in connection with burner controls for small-capacity burners in intermittent operation. The QRC1... and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products! Use The QRC1... is a compact UV-sensitive ue-flame detector with an integrated preamplifier. It is designed for frontal and lateral (90 ) illumination. This type of flame detector is suited for use with burner controls LOA2... (except LOA25...), LOA3..., LOA44..., LMOx4..., LGB3..., LAL1... and LAL4... and in terms of plug-in facility is compatie with the photoresistive detectors QRB1... The spectral sensitivity of the QRC1... is a maximum of approximately 300 nm so that it optimally covers the range of UV radiation of ue-burning oil or gas flames. Since the QRC1... also detects UV fractions of the radiation spectrum of other luminous sources (e.g. from boiler house illumination or sunlight), the standard regulations for extraneous light still apply. The QRC1... must not detect UV radiation from ignition sparks, as otherwise lockout occurs during the prepurge time, due to extraneous light. 09.07.2003 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not open, interfere with or modify the flame detector! Before performing any wiring changes, completely isolate the burner control from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the connection terminals Check to ensure that wiring is in an orderly state Fall or shock can adversely affect the safety functions. Such flame detectors may not be put into operation, even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulations are complied with Mounting work must be carried out by qualified staff Locate the ignition electrode such that the QRC1... cannot detect ignition sparks, as otherwise lockout occurs due to extraneous light Fit the flame detector with the help of a plug inserted in a hole on the burner. For hole on the burner, refer to «Dimensions». The securing and sealing lips of the plug give the QRC1... a firm hold in the hole, even in the case of viations, also allowing the detector to be removed for maintenance work Locate the QRC1... such that it can detect the most radiation-active zone of the flame For the precise adjustment of the distance between the most radiation-active range of the flame and the converging lens of the UV-sensitive diode, the QRC1... can be displaced in its plug by about 10 mm in both longitudinal directions (refer to «Dimensions») Installation notes Installation work must be carried out by qualified staff Observe the permissie length of the detector cae (refer to «Technical data») It is important to achieve practically disturbance- and loss-free signal transmission: - Line capacitance reduces the magnitude of the flame signal - Use a separate cae Always run the detector caes separately while observing the greatest possie distances from other caes and units Commissioning notes Commissioning work must be carried out by qualified staff Prior to commissioning, check to ensure that wiring is in an orderly state 2/8

Norms and certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Directive for gas appliances - Low-voltage directive 89 / 336 EEC 90 / 396 EEC 73 / 23 EEC ISO 9001: 2000 Cert. 00739 ISO 14001: 1996 Cert. 38233 Only in connection with the burner control Service notes Maintenance work must be carried out by qualified staff Each time a flame detector has been replaced, check to ensure that wiring is in an orderly state When cleaning the detector, always use a clean cloth Do not use any burner cleansing sprays Disposal notes The flame detector contains electrical and electronic components and may not be disposed of together with household waste. Local and currently valid legislation must be observed. Mechanical design The detector s housing is made of ack plastic and has a displaceae plug with stops. The 3-core connecting cae is firmly connected to the QRC1... and features strain relief. The front of the detector has a protective glass to ensure protection against accidental contact and dust. QRC1... with mirror fixture In the case of burner designs that do not allow the QRC1... to be illuminated from the front, the detector is also availae with a mirror attachment for lateral illumination. 3/8

Type summary Type code Q R C 1 A 1. 1 0 1 C 2 7 Voltage / mains frequency: 27: AC 230 V / 50...60 Hz 17: AC 110 V / 50...60 Hz (on request) Series Availae cae length "L" (refer to "Dimensions"): 00: 200 mm (on request) 01: 350 mm 02: 420 mm (on request) 03: 500 mm 04: 700 mm 05: 1000 mm (on request) Plug: 1: With plug 7716t02e/1299 Level of sensitivity: 1: Normal 2: Medium 3: High Direction of illumination: A: Front C: Lateral Standard types Type reference Frontal illumination Lateral illumination Level of sensitivity QRC1A1.101C27 x 1 QRC1A1.103C27 x 1 QRC1A2.101C27 x 2 QRC1A2.103C27 x 2 QRC1A2.104C27 x 2 QRC1A3.101C27 x 3 QRC1A3.103 C27 x 3 QRC1C2.103C27 x 2 Ordering When ordering, please give type reference according to «Standard types» or «Type summary». 4/8

Technical data General detector data Environmental conditions Mains voltage AC 230 V 15 / +10 % Mains frequency 50...60 Hz ±6 % Power consumption 0.35 VA Tolerated flame signal interruptions approx. 300 ms Length of connecting cae max. 1 m Length of auxiliary detector cae max. 20 m (only in case of separate cae runs, refer to «Max. detector cae length») Detector cae 3 x 0.5 mm²; 5.45 mm dia. Degree of protection IP40 Safety class II Viations to IEC 68-2-6 max. 1 g, 10...500 Hz Weight incl. 350 mm cae approx. 0.029 kg Mounting position optional Transport DIN EN 60 721-3-2 Climatic conditions class 2K2 Mechanical conditions class 2M2 Temperature range -25...+80 C Humidity < 95 % r.h. Operation DIN EN 60 721-3-3 Climatic conditions class 3K5 Mechanical conditions class 3M1 Temperature range -20...+60 C short-time (max. 1 min) up to 75 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted! Detector current at AC 230 V Type of burner control Min. detector current required During operation (typically) Max. permissie detector current Without flame (dark current) LMO... 70 µa 5.5 µa LOA2..., LOA3... 70 µa 5.5 µa LOA44... 58 µa 5.5 µa LGB3... 50 µa 5.5 µa LAL1..., LAL4... 80 µa 12 µa Function The QRC1 has a special UV-sensitive diode with a quartz-glass lens which concentrates the flame s radiation on the active part of the diode. A filter ensures that fractions of radiation of longer wave lengths will be eliminated. A preamplifier is used to amplify the signal of the diode to the level required for the flame signal amplifier of the respective burner control. Flame signal interruptions of short duration are tolerated (refer to «Technical data» under «Tolerated flame signal interruptions»), thus ensuring more stae detector currents and more stae operation of the burner in the event of strongly flickering flames. 5/8

Maximum detector cae length If the maximum cae length of 1 m is not sufficient, the burner manufacturer can extend the cae by a maximum of 20 m. In that case, the following rule must be observed when laying the cae: To minimize the coupling capacitances of the detector signal lines to the live conductor, live conductor «L» (own core) must be laid separately or segregated from the detector signal line. 7716m04/1299 max. 1m Z = max. 20m Legend Z Auxiliary cae Blue core = neutral conductor «N» Brown core = live «L» Black core = signal line 6/8

Spectral curves Extraneous light Is/% 100 90 80 70 60 50 40 30 1 2 3 20 10 0 200 300 400 500 600 700 800 900 1000 λ / nm 7716d01/9602 Flames Is/% 100 QRC1 40 20 10 4 2 1 4 5 0,1 0,01 0,001 7716d04/9602 0,0001 200 300 400 500 600 700 800 900 1000 λ / nm Sensitivity of light detector Es/% 100 90 80 6 7 9 70 60 8 50 40 30 20 10 7716d02/9602 0 200 300 400 500 600 700 800 900 1000 λ / nm Legend Is / % Relative intensity of radiation in % λ / nm Wave length in nm ES / % 2856 K-radiation QRC1... Spectral sensitivity of QRC1... 1 2856 K-radiation 2 2000 K-radiation 3 Solar radiation 4 Yellow-burning oil flame 5 Blue-burning oil flame 6 UV photocell 7 QRC1... photo diode 8 Selenium cell 9 QRB... photo resistance 7/8

Measuring circuit / connection examples Measurement of detector current For the detector currents required, refer to «Detector current» under«technical data». LMOx4... LOA2...*, LOA3..., LOA44... 1 11 12 LGB3... 12 2 1 LAL1... / LAL4... 1 22 23 + µa + + µa µa A A A 7716s04/0300 Connection examples For normal operation, remove the microammeter from the detector current measuring circuit. Dimensions Dimensions in mm Frontal illumination + - 0,1 14,2 2,2 S 7 15,8 13,5 LANDIS & GYR QRC1 A 2. 1 0 3 C 2 7 7716m01/0300 A 40...60 5 82 L 70 Lateral illumination + - 0,1 14,2 2,2 A S 7 15,8 13,5 LANDIS & GYR QRC1 A 2. 1 0 3 C 2 7 7716m02/0300 57...77 5 99 L 70 Legend * Except LOA25... Blue µa DC microammeter Brown (internal resistance Ri = max. 5 kω) Black A Incidence of illumination L Availae cae length (refer to «Type summary») S Range of displacement of plug produces a change in the dimensions......40...60 mm (front) 50 mm as supplied...57...77 mm (side) 67 mm as supplied 8/8 2003 Subject to change!