Cable Actuated Sensor Industrial User Scalable 4 20mA

Similar documents
Cable Actuated Sensor Industrial User Scalable VDC Output

Cable Actuated Sensor Industrial Incremental Encoder Output

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

PT9420 (Extended Range)

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

PT9600. Cable Actuated Encoder Reel. General. Environmental

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

PT9150 (Extended Range)

DP86 Constant Voltage with Fitting

MODEL 4000A & 4001A ACCELEROMETER

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86BSD Digital Output

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Standard SPECIFICATIONS FEATURES APPLICATIONS

MSP100 Pressure Transducer

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

LOW PRESSURE Intrinsically Safe Transducer AST44LP

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

MSP100 Pressure Transducer

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

FC22 Compression Load Cell

Sub psi SPECIFICATIONS

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

D5100 Industrial Differential Pressure Transducer

86BSD Digital Output

OPERATION MANUAL Model 8011 & mA

86BSD Digital Output

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

FC23 Compression Load Cell

D5100 Industrial Differential Pressure Transducer

ELAF LOAD CELL SPECIFICATIONS FEATURES

M5800 Pressure Transducer with Rotatable Display

P125 High Pressure Sensor

OPERATION MANUAL MODEL & ACCELEROMETER

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

U5600. Wireless Pressure Transducer SPECIFICATIONS

OPERATION MANUAL MODEL 805 ACCELEROMETER

TE Connectivity's AMP NETCONNECT Cable Management

15203B 25203B 35203B Uniaxial Biaxia Triaxial

89BSD Digital Output

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

M5800 Pressure Transducer with Rotatable Display

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

MODEL 834M1 ACCELEROMETER

MODEL ACCELEROMETER

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

OPERATION MANUAL MODEL 4610 ACCELEROMETER

MSP340 Pressure Transducer

M7100 Pressure Transducer

MS4525 SPECIFICATIONS

HM1500LF Relative Humidity Module

U5300 Industrial Pressure Transducer

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

M5200 Industrial Pressure Transducer

LMM-H04 Mass Air FLow Sensor

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

TESS WIRELESS SENSOR TAG DEMO V1.1

OPERATION MANUAL MODEL 8102 ACCELEROMETER

HM1520LF Relative Humidity Module

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

The Importance of Pressure Sensors in HVACR Systems

TS105-10L5.5MM Thermopile Sensor

LMM-H03 Mass Air FLow Sensor

OPERATION MANUAL MODEL 3255A ACCELEROMETER

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

U5700 Submersible Liquid Level Pressure Transducer

MINIATURE ELECTRONIC PRESSURE SCANNERS ESP-16HD/32HD/64HD

DOG2 MEMS SERIES USB INCLINOMETER

TESS WIRELESS SENSOR TAG DEMO V1.1

Seal Kits for BUDI Enclosures

TSYS02S Digital Temperature Sensor

OPERATION MANUAL MODEL 3038 ACCELEROMETER

MSP300 Pressure Transducer

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

TSEV01S01C10 SPECIFICATIONS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Transcription:

Cable Actuated Sensor User Adjustable Stroke Range to 175 inches (3 meters) Easy Push-Button Zero and Span Adjust Designed for Outdoor & IP67 environments In Stock for Quick Delivery! 175-inch model shown Specifications Full Stroke Range, SR1M-125 Full Stroke Range, SR1M-175 Minimum Full Stroke Range Output Signal Settings Input Voltage Accuracy, full stroke range 10 inches (254 mm) 125 inches (3175 mm), maximum 175 inches (4445 mm), maximum 1 inches (25 mm) 4...20mA, 20...4mA 10-30 VDC.5% FS. The SR1M is part of a series of rugged, low-cost, high performance string pots built for wet environments and outdoor applications. Designed for the rigors of outdoor construction equipment or the demands of a factory floor, the SR1M is the perfect low-cost solution for OEM and stocking distributors. What sets this sensor apart from other string pots, is the internal programmable digital circuitry that gives the customer a one-size-fits-all approach for many applications. The SR1M ships factory calibrated to the full stroke range but the output signal can be easily re-scaled to match any stroke down to 1 inch (25 mm). Accuracy, full stroke range < 10 inches (254 mm) Repeatability Resolution Output Signal Update Rate Maximum Velocity Maximum Acceleration consult factory.1% FS..0015% FS. 1 msec 80 inches (2 meters) per second 10 g (retraction) Measuring Cable Tension 23 oz. (6,4 N) ±30% Sensor Cycle Life Enclosure Measuring Cable Electrical Connection plastic-hybrid precision potentiometer 250,000 (potentiometer) polycarbonate.034-inch dia. nylon-coated stainless M12 Connector (mating plug included) Environmental Suitability NEMA 6, IP67 Operating Temperature -40 to 185 F (-40 to 85 C) Weight 2.5 lbs. (1.3 Kg) Output Signal SENSOR SOLUTIONS /// SR1M 12//2015 Page 1

Electrical Connection Factory Calibrated Stroke Range The full scale output signal is set at the factory to the maximum full stroke range of the sensor. The ZERO point (output = 4mA) is set at the beginning* of the stroke range (0 inches) and the SPAN point (output = 20mA) is set to the end of the range (125 inches or 175 inches depending on model). *Important The ZERO point is set at the factory with the measuring cable pulled out.125 inches from full retraction. If the measuring cable becomes fully retracted at any time when the sensor is under power, the output signal will begin to fluctuate. This is normal and fluctuation will stop as soon as the cable is extended greater than.125 inches. This is for the factory setting only and the ZERO may be reprogrammed at full retraction at any time. Cable Exit Direction Options Changing the Cable Exit Changing Measuring Cable Exit To change the direction of the measuring cable, remove the 4 mounting bracket screws and rotate bracket to one of four available positions. See figures 1-4 on the following pages for mounting dimensions. Changing Electrical Connector Direction To change the position of the electrical connector, remove the 4 rear cover screws and carefully separate rear cover from the sensor body. Rotate the rear cover to desired position being careful to not tangle the wiring harness that runs to the connector. SENSOR SOLUTIONS /// SR1M 12//2015 Page 2

Internal Controller Board Changing Output Signal Reprogramming ZERO and SPAN: The ZERO and SPAN points have been preset at the factory but can easily be changed to match any desired stroke within the full stroke limits of the sensor. To reprogram the SR1M to your own settings, remove the rear cover to gain access to the internal controller board. Locate the push-button on the circuit board and follow the instructions below. Please note that ZERO and SPAN points can be set independently. You can set one without setting the other. This operation must be performed with the sensor under power. Important: when you are finished, disconnect power for at least 2 seconds to permanently set your new settings. Setting Span: Set the cable to the desired SPAN point then depress and hold the button until the STATUS LED begins to flash RED. Release the button when the LED begins to flash RED (not GREEN). The flashing will then slow down to about two-second intervals to indicate that the SPAN value is being set into memory. When completed, the STATUS LED will turn off. Setting Zero: Set the cable to the desired ZERO point and then depress and hold the button until the STATUS LED begins to flash GREEN. Release the button when the LED begins to flash GREEN (not RED). The flashing will then slow down to about two-second intervals to indicate that the ZERO value is being set into memory. When completed, the STATUS LED will turn off. Remove power for 2 seconds then reconnect. Reversing the Output Signal The SR1M leaves the factory set with a 4...20 ma full scale output signal. The signal can be reversed (see illustration) by simply changing a dipswitch located on the controller board. This may be done without resetting the zero and span points. Remove the rear cover to gain access to the board. SENSOR SOLUTIONS /// SR1M 12//2015 Page 3

Fig. 1 - Outline Drawing (as shipped) Fig. 2 - Up Cable Exit Direction SENSOR SOLUTIONS /// SR1M 12//2015 Page 4

SPD SPD Compact, High-Performance Dual Ouput to 50" Fig. 3 - Down Cable Exit Direction Fig. 4 - Rear Cable Exit Direction SENSOR SOLUTIONS /// SR1M 12//2015 Page 5

SPD SPD Compact, High-Performance Dual Ouput to 50" Ordering Information Measurement Specialties, Inc., a TE Connectivity company 20630 Plummer Street Chatsworth, CA 91311 Tel +1 800 423 5483 Tel +1 818 701 2750 Fax +1 818 701 2799 info@celesco.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SR1M 12/01/2015 SENSOR SOLUTIONS /// SR1M 12//2015 Page 6