ALTURA 619 EXTRA TECHNICAL SHEET

Similar documents
EUROSPRINT NEXT TECHNICAL DATA SHEET

SPEEDY CARBONIUM TECHNICAL DATA SHEET

Rhinoskin Spray On Insulation Ceramic Insulation Coating

PRODUCT DATA KEFA AIRLESS 8125 and 8125B

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

Instructions for Coating Fimbel Garage Door Panels

Page 1 - MAINTENANCE OIL

Care instructions. for wood floors

What you need to know...

Bonding teak ship decks with SABA Deckfast MS

Dry Ice Blasting Frequently Asked Questions

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

Maitenance guide N 3. for oiled DI LEGNO parquet floors white finishing

Ekopel 2k. 2K bathtub resurfacing coating. pabrec.com. Description. Package. Advantages. Technical data sheet

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Application Instructions

Reference Guide for DC 333

MAINTENANCE GUIDE RESIDENTIAL AREAS

E-ZION - AUTO SHAMPOO CONCENTRATED CAR SHAMPOO

Use a dry, soft-bristle brush to dust fabric weekly to remove dirt before it becomes embedded.

VELVET MARMORINO. Fine natural mineral lime finish

ST-1 Surface Treatment

IFU 005 CLEANING / PREPARATION OF OUTDOOR HEAT EXCHANGE SURFACES & COILS. Date Approved

Dehumidifier. Instruction Manual. Model DH-320/A

USED OIL RE-REFINING UNIT PRESENTATION. Manufactured by GADGIL & COMPANY PUNE

MAINTENANCE GUIDE RESIDENTIAL & COMMERCIAL AREAS

SpectraSeal 2.1 VOC Color Primer Sealer

REGULAR MAINTENANCE AND CARE

CARE AND MAINTENANCE INSTRUCTIONS version: date: subject to errors or modifications

Roofing Adhesive SARNACOL 2172 Spray

Instructions for Coating Cellular PVC Solid Color (brushing and spraying)

TECHNICAL DATA 3% AR-AFFF

GENERAL PRODUCT CARE

Specification Document # page 1

HIGH EXPANSION INTUMESCENT SEALANT Prevents the spread of smoke and fire

1542 Jefferson Street, Teaneck NJ TEL: FAX:

PULIZIA MANUTENZIONE PIANI

ARRAY MODULAR FURNITURE Installation and Aftercare Instructions

SpectraPrime Color Primer Surfacer

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Professional cleaning detergents

Protect any surface with a nano layer. SIO6 Glass / Ceramics / Mirrors. SIO7 Metal / Aluminium / Paintwork. SIO8 Wood / Stone. SIO9 Fabrics / Leather

UNSIGNED HARDCOPY NOT CONTROLLED

NCERT solution for Heat

Care and maintenance instructions for products supplied by VEKSØ A/S

Electron Microscopy Sciences

ICS PACIFIC. Installation Instructions & User Manual. G135L Medical Refrigerator

SPØ1 OUTDOOR CARE INSTRUCTIONS

GREY line. CE Series Hood dishwashers

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK.

Stainless Steel 201. Considerations about an important ingredient of the brewery plant

STUCCO ITALIANO DI POLISTENA GIOVANNI. Viale S. Agostino, 346/A Vicenza - Italia Tel

Ceramic Infrared Heaters

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

Buehler Cast N Vac 1000 Embedding System

Pot Belly Black. Overview. Suitable Surfaces

The most efficient oil separator

For routine maintenance of polished granite installations with a cleaner and protector:

HOW TO OPERATE THE REFRIGERATOR COMPARTMENT

Requests for Care and Maintenance

WELCOME TO TARKETT FLOORING CONCEPTS

INSTRUCTION MANUAL SILHOUETTE SOFA. By GamFratesi

VT-DESOL2 DESOLDERING STATION DESOLDEERSTATION STATION DE DESSOUDAGE ENTLÖTSTATION USER MANUAL GEBRUIKERSHANDLEIDING MANUEL D'UTILISATION

Pocket Hardmount. Preventative Maintenance.

Requests for Daily Care and Maintenance

Product Data Sheet. NeverStrip UV Resilient. Matte. A NeverStrip Instant Film Coating. UV Resilient Matte

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

BLANCO is one of the leading manufacturers of solutions for household kitchens:

Wallpaper Hanging Instructions

FOOD AREA SOLUTIONS Cleaning Spray & Wipe Disinfectant Skin Care Vegetable Cleaning Beerline Cleaning Sanitisers

maintenance guidelines

Operating instructions Wine storage cabinet Page 16

Introduction The following illustrated instructions are a generic guide to the internal installation of Safety and Security Films.

VVIVID VINYL INSTALLATION GUIDE

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

METAL CERAMIC FAN HEATER

Cleaning and Maintenance Guide.

Guide for Thin Film Evaporation Edited 7/22/13 by Stephen Albright, BJAM & Steven Palefsky

Index. + Kleen Kote 200 Concentrate. + Kleen Krete. + Real Pump Power Spraying System. + Real Pump EXPRESS Portable Power Spraying System

Coatings for protection of FRP structures with heavy rain erosion loads

INSTALLATION & MAINTENANCE

EY

KARCHERS POLISHERS OPERATOR MANUAL

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

USING THE REFRIGERATOR COMPARTMENT

Pilkington Insulight Activ SPECIAL APPLICATIONS. Insulating glass units incorporating the world s first self-cleaning glass.

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U)

Metal, ceramic, plastic package products

Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5. Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10. Fig. 11 Fig. 12 Fig. 13. VL Super Pro - M0S Edizione 1L08

Turbo Circulating Fan (DC)

STEP BY STEP MAKEREADY PROCEDURES FOR A DUPLICATOR

The cutting-edge in environmentallyconscious industrial parts washing

2. PROCEDURE DESCRIPTION AND PROCESS FLOW

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

Adam stool H50. Specifications. Toke Lauridsen. Design Year 2010 Typology Collection Origin Material Tops

Maintenance Guide. for your Mercier prefinished floor PRINTED IN CANADA SP-CAREGUBIL 04-15

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

Request for daily care

Handheld Training Manual

Surface Preparation For Coatings

Transcription:

Product description Highly effective long-life anti-fouling paint, free from organostannic biocides, with very high copper content that, thanks to its peculiar formula, protects wooden, iron and fibreglass hulls for multiple seasons respecting the biological balance of the sea. The product meets the requirements of and is certified by the Rina and Lloyd s Register boards. It contains active substances compliant with the BPR regulation ((UE) regulation nr. 528/2012). Only the white colour is suitable for light alloy hulls. Product information Finish Matt Colour Black.201, Dark blue.118, Light blue.111, Red.171, Iron grey.165, White.001 The colour of the antifouling paint after diving may be slightly different. Small tinting differences may occur between different production batches: in case mix them before the application. Solids (by volume) ASTM D2369 50 ± 2 % 46 ± 2 % (white) Specific gravity UNI EN ISO 2811-1 1,90 2,00 g/cm³ 1,60 1,70 g/cm³ (white) Flash point UNI EN ISO 13736 38 C Typical Shelf life 3 years VOC (calculated average content) ISO 11890-2/2006 373 g/l Packaging 2,5 5 15 Lt 1

Application and use SURFACE PREPARATION Surfaces with old antifouling Good condition: remove contaminants and any vegetation through high pressure wash with fresh water. Sanding with 120-180 grain paper. If the old antifouling is unknown or of a different nature apply a coat of an insulator like Mistral Fondo. Bad conditions: remove contaminants, possibly vegetation and non-adherent material through high pressure wash with fresh water. Sanding with 80-120 grain paper or with a slight sandblasting, paying attention not to damage the paint system underneath the old antifouling. Apply coat of DEFENDER or MISTRAL FONDO primer onto the entire treated area before proceeding with the antifouling application. New surfaces or brought to new Fiberglass: Degrease the surface to be treated with solvent or with a suitable detergent. Wash with fresh water and remove any traces of oil and grease. All surfaces to be painted must be clean, dry and free of contaminants. Sandpaper with abrasive paper no. P180 - P220 and apply the primer onto the treated surface. Before proceeding with the application of the products, blow with clean and dry air to remove any residual sanding and dirt. Steel: Wash with fresh water and remove any traces of oil and grease (in case washing with the specific solvent). All surfaces to be painted must be clean, dry and free of contaminants. Perform a sandblasting treatment of grade Sa 2½ or, after consultation with our technicians, mechanical cleaning degree St 3. Overcoat with the proper primer the treated metal before oxidizing principles are present. Before proceeding with the application of the products, blow with clean and dry air to remove any residual sanding and dirt. New wood: The moisture content of the support must not exceed 18%. All surfaces to be painted must be clean, dry and free of contaminants. Sandpaper with paper no. P80 - P120. Before proceeding with the application of the products, blow with clean and dry air to remove any residual sanding and dirt. Lead: Wash with fresh water and remove any traces of oil and grease (in case washing with the specific solvent). All surfaces to be painted must be clean, dry and free of contaminants. Waxing with large grain disks (mechanical cleaning) the surface layer of metal must be completely and uniformly renewed, removing any oxidation residue and coated with the primer provided on the same day of preparation. Be careful not to exceed the incision. Before proceeding with the application of the products, blow with clean and dry air to remove any residual sanding and dirt. 2

APPLICATION METHODS Professional use Application methods (spray application is permitted using individual protective devices in suitable environments) Conventional Pressure 3.5 bar Nozzle 1.7-1.9 mm Airless Pressure 150 bar Nozzle 0.3-0.6 mm 3

APPLICATION DATA Thinner/Cleaning tools 703 Dry film thickness Wet film thickness Theoretical coverage at the recommended thickness N coats Recommended primers Standard application range 40-60 µm Recommended 60 µm 80-120 µm (colours) Standard application range 90-130 µm (white) 120 µm (colours) Recommended 130 µm (white) Application range at 8,3 m 2 /liter (colours) recommended thickness 7,7 m 2 /liter (white) 2 coats for a seasonal protection. Apply an extra coat in areas subjected to higher consumption/friction DEFENDER suitable for all substrates MISTRAL FONDO usable as primer on wood, iron, fiberglass or as insulator on old antifouling paints (Anticorrosiva CR Delta 3000 Delta UC HB - Anchorprimer) Drying time 10 15 20 30 Temperature C Min Max Min Max Min Max Min Max Overcoating interval 18 hrs N.L. 12 hrs N.L. 6 hrs N.L. 4 hrs N.L. (60 µm) 1-6 1-3 1-3 1-2 Launching 24 hrs 18 hrs 12 hrs 8 hrs months months months months N.B. The drying times and the overcoating intervals increase with higher thickness of the applied film. Always check that the existing painting film is perfectly dry before applying a further product coat. 4

CONDITIONS DURING THE APPLICATION ALTURA 619 EXTRA To avoid the formation of condensation, the temperature of the surface should be at least 3 C above dew point. During the application and curing the min. ambient temperature must not be lower than 10 C or higher than 30 C; substrate temperature must not be lower than 5 C, since curing is remarkably reduced at lower temperatures. Application is not advisable when relative humidity exceeds 80%. The term-hygrometric survey should be carried out near the surface to be coated. Make sure there is enough ventilation when the application takes place in closed areas. Storage It is recommended to avoid exposure to air and extreme temperatures. To maximize the shelf life in the can, it is good to check that the container is well closed during the storage and the temperature is between 5 C and 35 C. Avoid exposure to direct sunlight. Safety rules Observe the provisions of DPR 303 and 547. Avoid contact with the skin, for example. Operate in wellventilated places and, if in closed areas, use vacuum cleaners, fans and air conveyors. During the application use appropriate protections (masks, gloves, glasses, etc.). Before using, read sections 7-8 of the SDS. INSTRUCTIONS FOR THE DISPOSAL OF THE BIOCIDAL AND PACKAGING PRODUCT Empty packagings containing biocidal products: Dispose of empty packagings according to the requirements of the waste disposal law, for example by conferring them in the recycling center. Packages containing the unused biocidal product: Dispose of the product not used in accordance with the law of disposal of such waste, for example by conferring it in a recycling center, recycling of packaging is prohibited in this case. Do not empty into drains or watercourses. INSTRUCTIONS FOR THE SAFE SECURITY OF THE BIOCIDAL AND PACKAGING PRODUCT. Empty containers and containers still containing the biocidal product: Packaging must be disposed of as hazardous waste under the full responsibility of the holder of such waste. Do not empty into drains or watercourses. 5

Notes The values indicated in the present technical sheet can have slight variations from one batch to another. The applied product must not come in contact with water, chemicals or subjected to mechanical stress before the curing is complete. The wet film thickness is referring to the undiluted product. In case of dilution, this value increases. The above information is the result of accurate laboratory tests and practical experience, however, since the product is predominantly used outside the manufacturer's control, Boero Bartolomeo S.p.A. can only guarantee their quality. The information contained in this sheet may be subject to revision by the Company. For clarification, updates or further information, it is recommended to contact Boero Bartolomeo S.p.A. directly. The present datasheet annuls and replaces every other precedent to this one. Recommendations After the application of the last coat the maximum launching period of the antifouling is one month; with top quality copper oxide based products and with the agreement with our technical staff, the launching time may extend up to 3 months, providing that the hull is protected from moisture, rain or atmospheric agents with plastic or similar material. 6