Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Similar documents
Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Series 5000 Hydrazine Analyzer Model 60002

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

SECTION Fluorescent Dissolved Oxygen Measuring System

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS

SECTION Free/Available Chlorine Analysis System

for Drinking Water Systems

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Turbimax CUE21 / CUE22

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

OMA-300 Process Analyzer

AS950 PORTABLE SAMPLERS

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

WASTEWATER Online UV%Transmission Analyzer

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Free Chlorine Measuring System

Process Alarm Module RTA 421

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

UDC100 Universal Digital Controller Specifications

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

APPLIED. OMA-406R Rackmount Process Analyzer

Turbimax CUE21 / CUE22

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

PUV, PIR and PFO Series BROCHURE

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

ACTIVE INFRARED BARRIER

GasGard 100 Control System

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Hydrazine Analyzer Series 2171 Specifications

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

/8 DIN Level Indicator

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Controllers. Instruction Manual WARNING

Multi-Gas-Controller MGC2

LIQUIDATOR Electronic Ionization System

SEC Signature Process Gas Analyzer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

HIGH CAPACITY PRODUCT LINE

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

UDC 700 Universal Digital Controllers and Indicator Specifications

Beacon 800 Gas Monitor Operator s Manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Guide Specification Model CTG Automatic Transfer Switch

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Pioneer-R16 Gas Monitor Operator s Manual

Alarm Tone Generator Model AG17

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

HIGH CAPACITY PRODUCT LINE

Nov 08 PRODUCT SPECIFICATION SHEET

Model Q45P/R. ph/orp Monitor...

Chillgard Refrigerant Monitor

Spectron LSN (Life Safety Network) Suggested Specifications

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

UDA2182 Universal Dual Analyzer

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Global Water Instrumentation, Inc.

900MAX PORTABLE SAMPLERS

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

SECTION AUTOMATIC TRANSFER SWITCHES

Model Q45P/R. ph/orp Monitor...

3500/61E & 3500/67E Temperature Monitor

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

Flame Detection Jon Sarfas

UDA2182 Universal Dual Analyzer

Instruction Manual WARNING

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

CLARITY II TURBIDIMETER

Rosemount 4500 Hygienic Pressure Transmitter. Start

GAS PLUS ALARM SYSTEM

Operating Instructions. For. Alarm Control Module. Model SSR 500

DIVISION FINNED WATER-TUBE BOILERS

HFID Heated Total Hydrocarbon Analyzer Module

SECTION ph/orp Sensors

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Specification for On-Line UPS Battery Monitoring and Data Management System

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

AirGard. Air Flow Monitors

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Transcription:

Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. Phosphate process analyzer for semi - continuous monitoring of phosphate in water. 1.2 Measurement Procedures The phosphate analyzer shall be a semi-continuous reading instrument, monitoring from 1, 2, or 4 channels, using either the ascorbic acid colorimetric method of analysis for low range measurement of phosphate at a wavelength of 880 nm or the molybdovanadate colorimetric method of analysis for high range measurement of phosphate at a wavelength of 480 nm. 1.3 Alternates A. Other methods of measurement such as UV absorbance, single parameter colorimetric, or amperometric analyzers are not allowed. 1.4 System Description A. Performance Requirements 1. Measurement Range a. 4 to 3 000 µg/l (parts per billion) as PO4 (Low Range model) or 200 to 50 000 µg/l (parts per billion) as PO4 (High Range model) 2. Detection Limit a. 4 μg/l PO4 (LR Model) ; 200 μg/l PO4 (HR Model) 3. Accuracy a. ± 4 μg/l or ± 4% (the larger value) (LR model) or ± 500 μg/l or ± 5% (the larger value) (HR model) 4. Repeatability a. ± 1% (LR model) or ± 500 μg/l or ± 5% (the larger value) (HR model) 5. Response time at T>90% a. 10 minutes at 25 C (77 F), but adjustable to 15 minutes to reduce reagents consumption 1.5 Certifications A. EMC: CE compliant for conducted and radiated emissions CISPR 11 (Class A limits), EMC Immunity EN 61326-1 (Industrial limits), and EN 61010-1 B. Safety: General Purpose UL/CSA 61010-1 with cetlus safety mark; CSA C22.2 No 61010-1:2012 C. NEMA 4x/IP56 dust and water ingress protection rating D. C-tick (EN 61326-1: 2006) E. KC (EN 61326-1: 2006) 1.6 Environmental Requirements A. Operational Criteria 1. Storage Temperature: -20 to 60 C (-4 to 140 F) 2. Operating Temperature: 5 to 45 C (41 to 113 F) 3. Relative Humidity: 5 to 95 %, non-condensing 1.7 Warranty A. Warranted from manufacturer defects for two years (Europe) or one year (all other geographies) from date of shipment. 1.8 Maintenance and Service A. Scheduled Maintenance

Project Name Page 2 1. Bi or Tri-Monthly (depending on chosen cycle time) a. Replace the reagent(s), standard(s), and cleaning solution; may be extended depending on chosen cycle time 2. Quarterly a. Clean the instrument b. Clean sample cells and stir bar c. Clean sample holder 3. Semi-annually a. Replace the stir bar 4. Annually a. Replace internal and external sample filter b. Replace the fan filter c. Replace the reagent air filter d. Replace tubing e. Replace the check valve on the colorimeter f. Replace the sample cell B. Unscheduled Maintenance 1. Depending on sample composition, sample cells and sample holder may need more frequent cleaning PART 2 PRODUCTS 2.1 Manufacturer A. Hach Company, Loveland, Colorado 1. Hach 5500sc Phosphate Analyzer 2.2 Manufactured Unit A. The Hach 5500sc Phosphate analyzer consists of a microprocessor controlled analyzer designed to continually monitor concentration of Phosphate (PO4) in a sample stream. The analyzer also has the capability to intake grab samples for internal measurement and dispense grab samples for external verification. 2.3 Equipment A. Analyzer 1. The display screen shall be a colored 5.7 LCD screen, and shall include a dashboard view, with measurements recent calibration information, reagent status, and Prognosys indicators. 2. The display screen shall be capable of graphing all available parameters on a scalable time. 3. The analyzer shall be capable of a continual measurement of every 9 minutes or a user selectable interval between measurements of 4.5 to 240 minutes. 4. The analyzer shall be capable of grab sample IN (from external source to the analyzer) and grab sample OUT (from the analyzer to external source) to save time, without interrupting continuous sample flow to the analyzer. 5. The analyzer shall have Link2sc capability to communicate measurements and provide calibration information between the analyzer and laboratory spectrophotometers. 6. The analyzer must operate using 110-240VAC, 50/60 Hz power 7. The analyzer must be able to conduct 1-point automatic calibration using installed standards. 8. The analyzer shall operate with an LED light source at a peak wavelength of 815nm. 9. Four electromechanical, UL rated, SPDT relays (Form C) are provided for user-configurable contacts rated 100 to 230 Vac, 5 Amp at 30 VDC resistive maximum.

Project Name Page 3 a. The following can be programmed: 1) Alarm 2) Warning 3) Scheduler 4) Feeder control 5) Event control 6) Specific event alarm (defined in analyzer) b. The following parameters can be assigned to a relay: 1) Silica measurement 2) Real time clock 10. Four analog 0/4-20 ma outputs (with possibilities to extend to eight (8x)) are provided with a maximum impedance of 500 ohms. a. The following can be programmed: 1) Alarms: i. Low alarm point ii. Low alarm point deadband iii. High alarm point iv. High alarm point deadband v. Off delay vi. On delay 2) Controls: i. Linear i. Bi-linear ii. Logarithmic iii. PID b. The following parameters can be assigned to a 4-20mA output: 1) Phosphate Measurement 11. The analyzer shall have Prognosys capability to provide self and predictive diagnostics and provide preventive maintenance alerts and reminders 12. The analyzer shall provide the user with built in help screens 13. The analyzer shall provide for continuous purge of sample to drain to assure fresh sample to the analyzer and reduce analysis lag time 14. Sample shall be delivered to the analyzer at the pressure of 2 87 psi to preset pressure regulator 15. The analyzer shall provide separate discharge lines for unchanged (bypass) and contaminated sample (waste) 16. Software updates and data extraction shall be completed via an SD card B. Reagents and Standards 1. The analyzer shall use quick connect reagent bottles with pre-installed tubing. 2. Reagents shall be pressurized using a built-in air compressor 3. The analyzer shall include a 90 days supply of reagents (using a 15 minute cycle time) 4. The reagents usage shall be 2L of each reagent for every 90 days with a 15 minute cycle time 5. Manufacturer shall provide certified pre-mixed reagents and standards 2.4 Components A. Standard Equipment 1. 5500sc Phosphate Analyzer 2. Installation Kit 3. Installation Manual 4. Operations Manual 5. Maintenance and Troubleshooting Manual

Project Name Page 4 6. Three month supply of reagents, standards, and cleaning solution B. Dimensions: 804 mm x 452 mm x 360 mm (31.65 in x 17.79 in x 14.17 in) C. Weight: 21 kg (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents, standards and cleaning solution 2.5 Optional Accessories A. Reagents/Standards Replacement Kit B. Annual Maintenance Kit C. Sample Filtration Kit D. Colorimeter Cleaning Kit E. RS232/RS485 Modbus output card F. 4x 4-20mA analog output card G. US Power Cord Kit H. EU Power Cord Kit PART 3 EXECUTION 3.1 Preparation 3.2 Installation 1. Mounting a. Bench, panel, or wall mount 2. Sample Inlet a. 6mm OD quick connect fitting 3. Drain Outlet a. 11mm (7/16 in.) ID slip-on fitting 4. Sample Flow a. 55 to 300 ml/minute 5. Sample Pressure a. 2 to 87 psi (0.17 to 6 bar) 6. Sample Temperature a. 5 to 50 C (41 to 122 F) A. Contractor will install the analyzer in strict accordance with the manufacturer s instructions and recommendations. B. Manufacturer s representative will include a half-day of start-up service by a factory-trained technician, if requested. 1. Contractor will schedule a date and time for start-up. 2. Contractor will require the following people to be present during the start-up procedure. a. General contractor b. Electrical contractor c. Hach Company factory trained representative d. Owner s personnel e. Controls Technician (as required) 3.3 Manufacturer s Service and Start-Up

Project Name Page 5 A. Contractor will include the manufacturer s services to perform start-up on instrument to include basic operational training and certification of performance of the instrument. B. Contractor will include a manufacturer s Service Agreement that covers all the manufacturer s recommended preventative maintenance, and any necessary repairs beginning from the time of equipment startup through to end user acceptance / plant turnover and the first 12 months of end-user operation post turnover. C. Items A and B are to be performed by manufacturer s factory-trained service personnel. Field service and factory repair by personnel not employed by the manufacturer is not allowed. D. Use of manufacturer s service parts and reagents is required. Third-party parts and reagents are not approved for use. END OF SECTION