Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS

Similar documents
INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS. DLFSDA and DLFLDA Ducted Style Ductless System Sizes 09 to 58

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

DLFSCA and DLFLCA Cassette Ductless System Sizes 9 to 48 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHRB Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12

Product Data. 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless Split System Size 18K, 24K, 30K, 36K, 42K, 48K and 56k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ / 38MAQ High- Wall Ductless Split System Sizes 09 to 30

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High- Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data. 38GVM / 40GVM Multi---Split High---Wall Ductless Split System 38GVM --- Size 18k, 24k, 30k, 36k and 42k 40GVM --- Size 9k, 12k, and 18k

Product Data. 38GXM / 40GXM Multi---Split High---Wall Duct Free Split System 38GXM --- Size 18k, 24k, and 30k 40GXM --- Size 9k, 12k, and 18k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High Wall Ductless Split System Sizes 09 to 18

Product Data. DLCERA Outdoor Unit Single Zone Ductless System Sizes 09 to 24 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K K

PERFORMANCE DATA Model Numbers Cooling High Heating 47 F Low Heating 17 F

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GXC / 38GXC 40GXQ / 38GXQ Inverter---Driven High Wall Duct---Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. DHCMA / DACMA DHQMA / DAQMA High Wall Ductless System Sizes 09 to 22

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MG / 40MA / 40MB Multi- Zone Ductless Split System Size 18k, 27k, 36k and 48k INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. High --- Wall Duct --- Free Split systems INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 INDUSTRY LEADING FEATURES / BENEFITS

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Installation Instructions

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Installation Instructions

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Installation Instructions

Installation Instructions

Owner s Manual TABLE OF CONTENTS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

Installation Instructions

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Installation Instructions

Residential and Light Commercial Ductless Systems Catalog

R4H4. Product Specifications

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION 619PB / 538PR HIGH-WALL DUCTLESS SPLIT SYSTEM SIZES 09 TO 30

Owner's Manual TABLE OF CONTENTS

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless System Sizes 09 to 22

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL SPECIFICATIONS

Owner's Manual TABLE OF CONTENTS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

R4H4. Product Specifications

Owner s Manual TABLE OF CONTENTS

Installation Instructions

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Hi - Wall Split Systems 12K - 18K - 24K

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

N4H4. Product Specifications

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Advance Product Data

Advance Product Data

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

PAJ3. Product Specifications

MULTI INVERTER SERIE H6M

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

General Description. Operation

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Transcription:

0MBDQ Ducted lim Ductless ystem izes 09 to 58 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFET BALANE BETWEEN BUDGET LIMIT, ENERGY AVING AND OMFORT. The 0MBDQ series ducted slim ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted in the ceiling. This selection of fan coils permits creative solutions to design problems such as: NOTE: Images for illustration purposes only. Actual models may be slightly different. TABLE OF TENT PAGE MODEL NUMBER NOMENLATURE... 3 TANDARD FEATURE AND AEORIE... DIMENI... 5 INTALLATI LEARANE... 7 MAINTENANE LEARANE... 7 PEIFIATI... 8 APPLIATI DATA... 9 WIRING... 9 WIRING DIAGRAM... 12 GUIDE PEIFIATI... 15 Add ons to current space (an office or family room addition) pecial space requirements When changes in the load cannot be handled by the existing system. Historical renovations or any application where preserving the look of the original structure is essential. These compact indoor fan coil units take up very little space above the ceiling. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW OUND LEVEL When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. EURE OPERATI If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather. FAT INTALLATI This compact ductless system is simple to install. A mounting bracket and duct work is needed for the indoor units, and only wire and piping need run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ducted style ductless systems the equipment of choice, especially in retrofit situations. IMPLE ERVIING AND MAINTENANE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. oils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy accessible service panels. In addition, these ducted systems have extensive self diagnostics to assist in troubleshooting. BUILT IN RELIABILITY Ducted style ductless system indoor and outdoor units are designed to provide years of trouble free operation. The ducted indoor units include protection against freeze up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over current protection and the high temperature protection. INDIVIDUAL ROOM OMFORT Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year round comfort can be provided with heat pumps. EOMIAL OPERATI The ducted style ductless system design allows individual or multi room heating or cooling when required. There is no need to run large supply air fans or chilled water pumps to handle a few spaces with unique load patterns. EAY TO UE TROL The ducted units have microprocessor based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote control provides the interface between user and the unit. BUILT IN DENATE LIFT PUMP Factory installed condensate lift pump on the ducted fan coil provides installation flexibility. OPTIAL WIRED TROLLER Timer Function TANDARD WIRED TROLLER 7 Day Programmable AGENY LITING All systems are listed with AHRI (Air onditioning, Heating & Refrigeration Institute), and ETL. 2

MODEL NUMBER NOMENLATURE INDOOR UNIT 0 MB D Q 09 - - - 3 0 = FAN OIL UNIT MB = MODEL VOLTAGE 3 = 208/230-1-60 INDOOR FAN OIL TYPE D = DUTED TYLE YTEM TYPE Q = HEAT PUMP NOMINAL APAITY 09-1/ T 12-1/ T 18-1-1/2 T 2-2 T 36-3 T 8 - T 58-5 T NOT UED NOT UED Use of the AHRI ertified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 3

TANDARD FEATURE AND AEORIE Ease Of Installation Mounting Brackets Low Voltage ontrols omfort Features Rear or Bottom Return (Bottom Return only sizes 09-8) Vertical or horizontal installation (Vertical only sizes 09-8) Microprocessor ontrols Wired Remote ontrol (7 Day Programmable KAN0501AAA) Wireless Remote ontrol Auto Restart Function old Blow Protection On Heat Pumps Freeze Protection Mode On Heat Pumps Turbo Mode Auto hangeover On Heat Pumps Follow Me (ense Temperature at remote) Energy aving Features Outside Air Intake leep Mode top/tart Timer 6 F Heating Mode (Heating etback) afety And Reliability Indoor oil Freeze Protection Indoor oil High Temp Protection in Heating Mode Aluminum Golden Hydrophilic pre-coated fins Ease Of ervice And Maintenance leanable Filters Diagnostics Liquid Line Pressure Taps Application Flexibility Built-in ondensate Lift Pump Legend tandard A Accessory AEORIE ORDERING NO. DERIPTI FOR MODEL KAN0101AAA Optional Wired Remote ontrol All izes with Timer Function KAIF001AAA Wi-Fi Kit All izes

DIMENI OUTLINE DIMENI AIR OUTLET OPENING IZE AIR RETURN OPENING IZE HANGER BRAKER REFRIGERANT PIPE LOATI ize Unit A B D E F G H I J K L M H1 H2 W1 W2 In. 27.6 7.9 19.9 17.7 5. 21.1 1.2 6 23.6 7.3 2 29.2 1.2 3.3 5.5 3.3 3.3 0 9 mm 700 200 506 50 137 537 30 152 599 186 50 71 360 8 10 8 8 18.1 In. 27.6 7.9 19.9 17.7 5. 21.1 1.2 6 23.6 7.3 2 29.2 1.2 3.3 5.5 3.3 3.3 0 12 mm 700 200 506 50 137 537 30 152 599 186 50 71 360 8 10 8 8 18.1 In. 3.65 8.27 26.5 23.62 5.57.80 1.97 5.35 30.79 7.8 1.57 36.22 20 3.07 5.83 3.6.1 5 18 mm 880 210 67 600 10 706 50 136 782 190 0 920 508 78 18 88 112 2.5 In. 3.31 9.8 30.7 27.56 5.51 36.6 1.97 6.89 39.1 8.98 0.2.88 23.5 3.15 5.91 5.12 6.1 87 2 mm 1100 29 77 700 10 926 50 175 10028 5 110 598 80 150 130 155 39. In. 53.5 9.8 30.7 27.56 5.51 6.69 1.97 6.89 9.65 8.98 0.2 55.12 23.5 3.15 5.91 5.12 6.1 106 36 mm 1360 29 77 700 10 1186 50 175 12628 5 100 598 80 150 130 155 8.3 In. 7.2 11.81 3.1 31.5.8 1.1 1.97 8.9 3.35 11.02 0.2 8.82 27. 3.15 5.91 7.28 8.27 120 8 mm 1200 300 87 800 123 10 50 227 11080 5 120 697 80 150 185 210 5.3 In. 55.12 17.32 33.78 30.31.17 6.81 1.1 15.16 6.5 11.02 1.57 56.57 27.56 8.15 10.75 5.67 5.67 163 58 mm 100 0 858 770 106 1189 28 385 1182 280 0 137 700 207 273 1 1 7 OPERATING WEIGHT lb (kg) Air filter Air inlet from rear side Outside air intake -install hanger Electric control box 0.98in (25mm) Drain pipe Gas connection Liquid connection Test mouth & Test cover 0.98in (25mm) Drain connecting pipe (for lift pump) Air filter Air inlet from bottom side Fig. 1 Indoor Unit izes 9K 8K 5

DIMENI (T) Fig. 2 Indoor Unit izes 58K 6

> 11.8in(30c m) (When no ceiling) INTALLATI LEARANE Left side >in(10cm) Maintenance space trong and durable ceiling Indoor unit MAINTENANE LEARANE >11.8in(30cm) Right side Fig. 3 Installation learances >0.8in(2cm) >0.8in(2cm) ervice access Floor eiling >11.8in(30cm) > 8.2in(250cm) Width of the Unit Unit ervice access OIL NETI AREA DENATE DRAIN PIPING AREA DENATE PUMP ERVIE LEARANE ENOR ERVIE LEARANE > i n(1 0 c m ) B ervice access >11.8in 30cm PB BOARD ERVIE LEARANE FILTER ERVIE LEARANE Fig. Maintenance learances apacity (Kbtu) 9K 12K 18K 2K 36K 8K 58K Table 1 Maintenance learances B 11.81in.(30cm) 11.81in.(30cm) 11.81in.(30cm) 11.81in.(30cm) 11.81in.(30cm) 15.75in.(0cm) 15.75in.(0cm) 7

PEIFIATI ystem Electrical ontrols Operating Range Piping Indoor Heat Pump ize 09K 12K 18K 2K 36K 8K 58K Indoor Model 0MBDQ09---3 0MBDQ12---3 0MBDQ18---3 0MBDQ2---3 0MBDQ36---3 0MBDQ8---3 0MBDQ58---3 Voltage, Phase, ycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Power upply Indoor unit powered from outdoor unit MA A. 1.11 1.11 1.2 1.2 2.5 3.2 3.65 Wireless Remote ontroller tandard tandard tandard tandard tandard tandard tandard ( F/ onvertible) Wired Remote ontroller tandard tandard tandard tandard tandard tandard tandard ( F/ onvertible) ooling Indoor DB Min-Max F ( ) 63~90(17~32) 63~90(17~32) 63~90(17~32) 63~90(17~32) 63~90(17~32) 63~90(17~32) 63~90 (17~32) Heating Indoor DB Min-Max F ( ) 32~86 (0~30) 32~86 (0~30) 32~86(0~30) 32~86(0~30) 32~86(0~30) 32~86(0~30) 32~ 86 (0~ 30) Pipe onnection ize-liquid in (mm) 1/ (6.35) 1/ (6.35) 1/(6.35) 3/8(9.52) 3/8(9.52) 3/8(9.52) 3/8 (9.52) Pipe onnection ize-uction in (mm) 3/8 (9.52) 1/2 (12.7) 1/2(12.7) 5/8(16) 5/8(16) 5/8(16) 3/ (19) Unit Width in (mm) 27.559(700) 27.559(700) 3.65(880) 3.31(1100) 53.5(1360) 7.2(1200) 55.12 (100) Unit Height in (mm) 7.87(200) 7.87(200) 8.27(210) 9.8(29) 9.8(29) 11.81(300) 17.32 (0) Unit Depth in (mm) 19.92(506) 19.92(506) 26.5(67) 30.7(77) 30.7(77) 3.1(87) 33.78 (858) Net Weight lbs (kg) 3.56(19.8) 3.56(19.8) 5(2.5) 86.86(39.) 106.8(8.3) 119.71(5.3) 163 (7) Fan peeds 3 3 3 3 3 3 3 Airflow (lowest to highest) FM 17/211/26 177/283/353 300/00/80 0/700/780 700/910/1080 720/1030/1230 1260/1710/2150 ound Pressure (lowest to highest) db(a) 30/3/38 35/37/38 35/37/39 35.5/0/ 38.5/2/5.5 6/9.5/50.5 51/5/57 Max tatic Pressure In.WG. 0.2 0.2 0.0 0.6 0.6 0.6 0.80 Field Drain Pipe ize O.D. in (mm) 1(25.) 1(25.) 1(25.) 1(25.) 1(25.) 1(25.) 1 (25.) Performance may vary based on the outdoor unit matched to. ee the compatible outdoor units product data for Performance Data. OMPATIBILITY Unit ize 0MBDQ09---3 0MBDQ12---3 0MBDQ18---3 0MBDQ2---3 0MBDQ36---3 0MBDQ8---3 0MBDQ58---3 Outdoor Unit ingle Zone 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB2R--3 38MBRQ36A--3 38MBRQ8A--3 38MBRQ58A--3 38MGRQ2--3 Outdoor Unit Multi-zone 38MGRQ30D--3 38MGRQ36D--3 38MGRQ8E--3 NOTE: Backward compatible with ingle Zone ystems 38MAQ sizes 09 2, 38MBQ izes 36 8 and Multi zone ystems 38MGQ. 8

APPLIATI DATA UNIT ELETI elect equipment to either match or that can handle slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part load operation. For units used in spaces with high sensible loads, base equipment selection on unit sensible load, not on a total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing equipment. UNIT MOUNTING (INDOOR) Refer to unit Installation Instructions for further details. Unit leveling For reliable operation, units should be level in all planes. learance Provide adequate clearance for airflow as shown in Fig. 3. Unit location elect a location which provides the best air circulation for the room. These units should be positioned as accessible as possible above the ceiling. The unit return and discharge should not be obstructed by furniture, curtains, or anything which may cause unit short cycling or air recirculation. Duct the unit in the middle of the selected wall (if possible). Duct towards an outside wall, if available, to make piping easier, and place the unit so it faces the normal location of room occupants. UNIT MOUNTING (OUTDOOR) Refer to unit Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. For those applications, contact your ductless representative. MOUNTING Refer to unit s Installation Instructions for further details. UPPORT Adequate support must be provided to support the weight of all fan coils. Refer to the Physical Data section for fan coil weights, and the base unit dimensional drawings for the location of mounting brackets. YTEM OPERATING DITI OPERATING RANGE Min / Max F ( ) ooling Heating Indoor DB 63 / 90 (17 / 32) 32 / 86 (0 / 30) Indoor WB 59 / 8 (15 / 29) NOTE: Reference the product Installation Instructions for more information. DRAIN NETI Install drains to meet local sanitation codes. The standard ducted fan coil unit condensate lift pump has a maximum lift of 29.5 in. (750mm). WIRING All wires must be sized per NE (National Electrical ode) or E (anadian Electrical ode) and local codes. Use Electrical Data table MA (minimum circuit amps) and MOP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Recommended onnection Method for Power and ommunication Wiring: The main power is supplied to the outdoor unit. The field supplied 1/3 stranded wire with ground with a 600 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four () wires and provides the power for the indoor unit. Two wires are line voltage A power, one is communication wiring () and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended. If installed in a high Electromagnetic field (EMF) area and communication issues exists, a 1/2 stranded shielded wire can be used to replace L2 and () between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only.! AUTI EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Wires should be sized based on NE and local codes.! AUTI EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Be sure to comply with local codes while running wire from the indoor unit to the outdoor unit. Every wire must be connected firmly. Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Ensure all wiring is tightly connected. No wire should touch the refrigerant tubing, compressor or any moving parts. Disconnecting means must be provided and shall be located within sight and readily accessible from the air conditioner. onnecting cable with conduit shall be routed through the hole in the conduit panel. 9

TROL YTEM The indoor unit is equipped with a microprocessor control to perform two functions: 1. Provide safety for the system 2. ontrol the system and provide optimum levels of comfort and efficiency The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor also) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. WIRELE REMOTE TROL WIRED REMOTE TROL P/N KAN0101AAA (optional available as an accessory) P/N KAN0501AAA (included with the Unit) 1. Wired remote controller used for system operation of all ducted units. 2. Kit includes a wired remote controller and a connecting cable. NOTE: Extension wire available through RD (KAN0101AAA Part Number: 170120001601; KAN0501AAA Part Number: 170120000769). 3. onnect with wire terminal between remote controller and indoor unit.. Display in F or and temperature increments every 1 F or every 1. Fig. 5 Wireless Remote ontrol 1. A wireless remote control is supplied for system operation for system operation of all ducted units. 2. Each battery operated wireless (infrared) remote control may be used to control more than one unit. Fig. 6 KAN0101AAA (Timer Function) AIR FLOW DATA Fig. 7 KAN0501AAA (7 Day Programmable) ystem ize 9K 12K 18K 2K 36K 8K 58K High 26 353 80 780 1080 1230 2150 Indoor (FM) Medium 2182.5 00 700 910 1030 1710 Low 17 176.5 300 0 700 720 1260 OUND PREURE ooling operation Indoor ound Pressure Heating operation Indoor ound Pressure ystem ize dba at (High/Med/Low FM) dba at (High/Med/Low FM) 9K 12K 18K 2K 36K 8K 58K 38/3/30 39/37/35 39/37/35 /0/35.5 5.5/2/38.5 50.5/9.5/6 58.3/57.3/53.9/51.2 39/35/31 37/36/3 37/36/3 1.9/39.2/36.7 5./3/39. 50.1/8.5/5.3 56.9/56.9/53.7/50.6 OUND PREURE TETING METHOD Unit Outlet Indoor Unit 3.2 ft (1m) x 3.2 ft (1m) Microphone Fig. 8 ound Pressure Testing Method 10

OUND POWER ystem size ooling Operation Indoor ound Power Heating Operation Indoor ound Power ooling Operation Indoor ound Power (Turbo Mode) Heating Operation Indoor ound Power (Turbo Mode) dba (@ High FM) dba (@ High FM) dba (@ High FM) dba (@ High FM) 9K 12K 18K 2K 36K 8K 58K 55. 59.5 6 66.9 69.6 70. 76.2 60.2 63.3 62.6 68.2 70.8 71.6 7.1 5. 58.5 63 65.9 68.6 69. 75.2 59.2 62.3 61.6 67.2 69.8 70.6 73.1 FAN AND MOTOR PEIFIATI 9K 12K 18K 2K 36K 8K 58K Ducted Material Plastic Plastic Metal Metal Metal Metal Metal Indoor Fan Type LX-15*158* 15-1J LX-15*158* 15-1J FLBJ-150*158* 12-1 FLBJ-200*198* 12-6 FLBJ-200*266* 12.7-6 FLBJ-230*26* 12.7-0 FLBJ-227*23* 12.7-3 Diameter inch 5.9 5.9 6.06 inch 7.87 inch 7.87 inch 9.06 inch 8.9 Height inch 5.9 5.9 6.22 inch 7.80 inch 10.7 inch 10.39 inch 9.21 Indoor Fan Motor Model ZKFN-55-8-22 ZKFN-55-8-22 ZKFN-160-8-1-2 ZKFN-160-8-1-2 ZKFN-300-8-1 ZKFN-560-8-1-1 ZKFN-700-8-1 Volts V 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Type D D D D D D D Phase 3 3 3 3 3 3 3 FLA 1.11 1.11 1.65 1.65 2.5.1 3.65 Insulation class E E E E E E B afe class IPX0 IPX0 IPX0 IPX0 IPX0 IPX0 IPX0 Input W 130 130 200 200 20 560 1000 Output W 55 55 160 160 300 560 700 Range of Amps 1±10% 1±10% 1.2±10% 1.2±10% 2.5±10% 3.2±10% 3.65±10% current Rated current Amps 1.11 1.11 1.2 1.2 2.5 3.2 3.65 Rated HP HP 0.18 0.18 0.27 0.27 0.56 0.75 0.952 peed rev/ min 1100-1350 1100-1350 850/700/50 880/820/690 1130/1050/990 890/820/80 1060/910/790 Rated RPM Max. input rev/ min 1350 1350 1300 1300 1280 1020 1060 W 130 130 160 160 20 560 1000 11

WIRING DIAGRAM Fig. 9 Wiring Diagram ize 9K 2K ode N1 N2 N3/N26 N5 N6 N8/N18 N9 N10(N10A) N12 N13 N15 N23 N33 N0 N3 Indoor Unit Part Name Input: 230VA High Voltage onnection of the terminal Input: 230VA High Voltage onnection of the terminal Output: 0V onnection of the earth Output: 0-5VD onnection of the water level switch Output: 5VD onnection of the room and pipe temperature Output: 320VD High Voltage onnection of the reactor Output: 5VD onnection of the M Output: 12VD onnection of the display board Output: 220VA High Voltage onnection of the electrical heater Output: 220VA High Voltage onnection of the pump Output: 320VD High Voltage onnection of the fan board Output 1-12VD onnection of the remote switch Output: 0V onnection of the alarm Output: 12VD onnection of the wire controller Output: 220VA High Voltage onnection of the fresh air suction fan 12

WIRING DIAGRAM (T) Fig. 10 Wiring Diagram ize 36K 8K ode N1 N2 N5 N6 N8/N18 N9 N10(N10A) N13 N15 N23 N33 N0 Indoor Unit Part Name Input: 230VA High Voltage onnection of the terminal Input: 230VA High Voltage onnection of the terminal Output: 0-5VD onnection of the water level switch Output: 5VD onnection of the room and pipe temperature Output: 320VD High Voltage onnection of the reactor Output: 5VD onnection of the M Output: 12VD onnection of the display board Output: 220VA High Voltage onnection of the pump Output: 320VD High Voltage onnection of the fan board Output 1-12VD onnection of the remote switch Output: 0V onnection of the alarm Output: 12VD onnection of the wire controller 13

WIRING DIAGRAM (T) 16023000007021 WIRING DIAGRAM FOR ANTI-OLD WIND W1 EN1 ODE POWER FOR ETTING NETADDRE 1+2 ODE FOR ETTING POWER(D MOTOR MODEL LY) NETADDRE 0 8 3 FATORY ETTING 0 3 0 8 3 0 0 8 3 3 0 8 5 7 8 9 A B 53 5~71 72~90 91~105 106~10 11~160 161 FATORY ETTING AORDING TO RELATED MODEL. TEL0 2 15 8 FATORY ETTING FOR ETTING AUTO-RETART W3 FATORY ETTING 1 EEPROM AULT MODE AUTO-RETART NOT AUTO-RETART FOR MAIN-LAVE ETTING W5 MAIN MODE NO LAVE MAIN FATORY ETTING MAIN 1 LAVE FOR TEMP. OMPENATI(HEATING) W6 FATORY ETTING 3 0 0 8 8 8 8 0~F 0~F 0~F 0~F 0~15 16~31 32~7 8~63 FAN M 5 3 Y/G WHITE WHITE (GRAY) BLAK AP BROWN 3 0 8 3 0 8 3 ODE 6 2 3 3 FAN FOR THE FREH AIR ALARM FAN OR ANI OUTPUT GENERATOR M FAN1 D MOTOR RED DRIVER MODLE 2 Y/G N1 1 RED 3 REATOR 3 0 8 EEPROM AULT 3 N3 N P2 P1 N5 HB HA WIRE TROLLER N15 INDOOR UNIT MAINBOARD N0 WIRE TROLLER N9 X Y E To M omm.bus Fig. 11 Wiring Diagram ize 58 N3 ALARM /OFF J7 N33 N23 2 N13 M PUMP Y/G N20 2 1 N10 N6 N7 N5 TO OUTDOOR OMM.BU REMOTE TROL N18 MAGNETI RING Y/G 10 N2 N1 MAGNETI RING NOTE: 1.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. DIPLAY BOARD BLAK RED 5 WIRE TROLLER T2 BLAK INDOOR OIL TEMP. ENOR WHITE T2B T1 ROOM TEMP. ENOR INDOOR OIL OUTLET TEMP. ENOR L1 L2 WATER LEVEL WITH TO OUTDOOR UNIT FOR OUTDOOR POWER UPPLY L1 L2 MAGNETI RING L1 L2 Y/G POWER ode N1 N2 N3/N26 N5 N6 N7 N8/N18 N9 N10(N10A) N13 N15 N23 N33 N20 N1 N3 Indoor Unit Part Name Input: 230VA High Voltage onnection of the terminal Input: 230VA High Voltage onnection of the terminal Output: 0V onnection of the earth Output: 0-5VD onnection of the water level switch Output: 5VD onnection of the room and pipe temperature Output: 5VD onnection of the indoor coil outlet temperature sensor T2B Output: 320VD High Voltage onnection of the reactor Output: 5VD onnection of the M Output: 12VD onnection of the display board Output: 220VA High Voltage onnection of the pump Output: 320VD High Voltage onnection of the fan board Output 1-12VD onnection of the remote switch Output: 0V onnection of the alarm Output: 2VD between N2 onnection of the signal Output: 2VD between N2 onnection of the signal Output: 220VA High Voltage onnection of the fresh air suction fan 1

GUIDE PEIFIATI INDOOR DUTED LIM DUTLE UNIT ize Range: 1/ to 5 Ton Nominal ooling and Heating apacity Model Number: 0MBDQ PART 1 GENERAL 1.01 ystem Description Indoor, slim ducted, direct expansion fan coils are matched with a heat pump outdoor unit. 1.02 Agency Listings Unit is rated per AHRI tandards 210/20 and listed in the AHRI directory as a matched system. 1.03 Delivery, torage, And Handling Units are stored and handled per unit the manufacturer s recommendations. 1.0 Warranty (For Inclusion By pecifying Engineer) PART 2 PRODUT 2.01 Equipment A. General: Indoor, direct expansion, ceiling mounted fan coil. The unit is complete with cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and integral temperature sensing. B. Unit abinet: Unit cabinet is constructed of galvanized steel. The cabinet is fully insulated for improved thermal and acoustic performance.. Fans: The fan is tangential direct drive blower type with air intake at the rear or bottom of the unit and discharge at the front. D. oil: The coil is a copper tube with aluminum fins and galvanized steel tube sheets. The fins are bonded to the tubes by mechanical expansion and specially golden hydrophilic pre coated for enhanced wet ability. A drip pan under the coil has a factory installed condensate pump and drain connection for hose attachment to remove condensate. E. Motors: The motors has an open drip proof, permanently lubricated ball bearing with inherent overload protection. Fan motors are 3 speed. F. ontrols: The controls consist of a microprocessor based control system which controls the space temperature, determines optimum fan speed, and runs self diagnostics. The temperature control range is 62 F to 86 F (17 to 30 ) in increments of 1 F or 1, and has a 6 F Heating Mode (Heating etback). The wireless remote controller can act as the temperature sensing location for room comfort. The unit has the following functions as a minimum: 1. An automatic restart after power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 2 hour timer cycle for system Auto tart/top. 3. Temperature sensing controls sense return air temperature.. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Dehumidification mode provides increased latent removal capability by modulating system operation and set point temperature. 7. Fan only operation to provide room air circulation when no cooling is required. 8. Diagnostics provide continuous checks of unit operation and warn of possible malfunctions. Error messages appear on the unit. 9. The fan speed control is user selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes. 10. Automatic heating to cooling changeover in heat pump mode. The control includes deadband to prevent rapid mode cycling between heating and cooling. 11. Indoor coil high temperature protection is provided to detect an excessive indoor discharge temperature when unit is in the heat pump mode. G. Electrical Requirements: The indoor fan motor operates on 208 230V. Power is supplied from the outdoor unit. H. Operating haracteristics: The 0MBDQ system has a minimum EER (easonal Energy Efficiency Ratio) and HPF at AHRI conditions, as listed on the specifications table. I. Refrigerant Lines: All units have refrigerant lines that can be oriented to connect from the side of the unit. Both refrigerant lines need to be insulated. 15

opyright 2018 arrier orp. 7310 W. Morris t. Indianapolis, IN 6231. Edition Date: 0/18 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. atalog No: 0MBDQ-02PD Replaces: 0MBDQ-01PD 16