Express Lavatory System SS-Series

Similar documents
SS-2N Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

FL-2H, FL-2L Frequency Lavatory System FL-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

AV60 Advocate Lavatory System AV-Series

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

AV90 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

WF2613 Classic Corner Washfountain with 9" Deep Bowl

AV60 Advocate Lavatory System AV-Series

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

LD-5010 OmniDeck with WashBar 5000 Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

FL-3H, FL-3L Frequency Lavatory System FL-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation Instructions OBSOLETE

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

LA45 DISCONTINUED IMPORTANT!

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

LA90 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

LVSD2 Verge Wash Basin LVS-Series

Washfountain Application Guide

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVSD2 Verge Wash Basin LVS-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVQD3 Verge with WashBar Technology LVQ-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

School Solutions Ideabook

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

PAT BASIN MODEL 9121, 9131, & 9141

MERIDIAN MODEL# 3793

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon Lav Decks WARNING

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

LVQD1 Verge with WashBar Technology LVQ-Series

A. Section Joint Sealants: Seal fixtures to walls and floors.

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Installation Instructions

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Installation Instructions

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Installation Instructions

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

Installation Instructions

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Ligature Resistant. ADA Compliant

Models: FM FM WARNING

Automatic Temperature Controller (ATC)

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

Installation S

HL45, HL80 Thermostatic High-Low Valves

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Transcription:

P L U M I N G F I X T U R E S Model SS-3N/IR3 (attery Infrared Control) ADA, ANSI and UFAS Compliant Serves One to Three Users at a Time Continuous owl is constructed of Vandal Resistant Terreon Solid Surface Material Standard Lavatory Spacing on Centers Available in 18 colors Reliable Infrared Activation, Pushbutton Air Valve, attery Operated Infrared or Touch Time Metering Control Optional Electric Tankless Water Heater Specifications Accommodates one to three users. These units handle washroom traffic quickly and economically while providing each user with their own personal space. The lavatories for the Express system are positioned on centers. The preassembled sprayhead module is equipped with independent streamformers that are each served by a separate infrared sensing module and solenoid valve (Model SS-3N/IR), a pushbutton air metering valve (Model SS-3N/AST), an independent battery IR sensor and batteries (Model SS- 3N/IR3) or a pushbutton Touch Time electronic metering valve (Model SS-3N/TT). Standard flow rate of.5 GPM meets industry standards for water conservation while providing enough water to rinse hands quickly and efficiently. Operating range is 20-80 PSI. Construction owl/sprayhead Cover Constructed of Terreon, a densified solid surface material composed of polyester resin. Terreon is resistant to chemicals, stains, burns, and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Pedestal/Scuff Panels Panels are composed of vacuum-formed acrylic laminate. Highly resistant to impact, abrasion, acid and corrosion. The panels will not dent, chip, peel or flake. Support Frame owl assembly and panel are secured to a heavy gauge stainless steel support frame mounted to the wall. Standard frame (floor unit) includes scuff base. Vandal Resistance The molded sprayhead is an integral part of the bowl module, Its concealed vandal resistant streamformers discourage abuse. The infrared sensor will automatically shut off water flow after 30-45 seconds if a vandal attempts to trigger constant operation by covering the sensor or by placing a stationary object in the sensor's detection area. Pushbuttons are secured to the unit from inside the sprayhead. Air valves, water supplies, control boxes, and waste are concealed within the pedestal/support frame assembly Model SS-3N/IR/WH/LSD Code Compliance and Certifications ANSI Standards: Terreon is NAH certified to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. UPC Approval: The Express Lav Systems are Uniform Plumbing Code (UPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Standard Frame The standard frame on the Express SS-Series includes a scuff base and is designed to comply with all ADA guidelines on reaches, clearances and operation for adult users. Wall-Hung Frame The wall-hung frame on the Express SS-Series (less scuff base above) is designed to mount at different heights (adult and children) to comply with guidelines on reaches, clearances and operation for various codes including, ADA Accessibility Guidelines for uildings and Facilities (ADAAG) and TAS (Texas Accessibility Standards). Always check your local and state codes. C U P C R TAS 2003 radley Corporation LS1025.1 P.O. ox 309, Menomonee Falls, WI 53052-0309 Phone 1-800-RADLEY FAX 262-251-5817 http://www.bradleycorp.com

Express Lavatory System SS-Series Model SS-3N/IR Model SS-3N/AST Model SS-3N/TT Model SS-3N/IR3 P L U M I N G F I X T U R E S 80" (2032) TOP VIEW 8" (203) Radius 10" (254) Radius 68-1/4" (1734) FRONT VIEW STANDARD FRAME 8" (203) 51-1/4" (1302) 58" (1473) 64" (1626) 68-1/4" (1734) FRONT VIEW WALL-HUNG FRAME 8" (203) 58" (1473) 64" (1626) radley Corporation reserves the right to make changes in design and material without formal notice and without incurring obligation. Verify all rough-in dimensions prior to installation. 1-19-2005 LS1025.2

P L U M I N G F I X T U R E S Express Lavatory System SS-Series Model SS-3N/IR Model SS-3N/AST Model SS-3N/TT Model SS-3N/IR3 Dimensions shown in parentheses are millimeters. STANDARD HEIGHT WALL HUNG MOUNTED AT STANDARD HEIGHT 34" (864) 13-1/4" (311) 3" (76) SCUFF ASE ON STANDARD HEIGHT ONLY 34" (864) 13-1/4" (311) WALL HUNG MOUNTED AT JUVENILE HEIGHT AGES: 6 THROUGH 12 35-1/2" (902) 31" (787) 27" (686) 10-1/4" (260) WALL HUNG MOUNTED AT TAS HEIGHT GRADES: 6 THROUGH 8 OR 9 WALL HUNG MOUNTED AT TAS HEIGHT GRADES: PRE-K THROUGH 5 OR 6 36-1/2" (927) 34-1/2" (876) 32" (813) 28" (711) 26" (660) 11-1/4" (286) TAS 9-1/4" (235) TAS radley Corporation reserves the right to make changes in design and material without formal notice and without incurring obligation. Verify all rough-in dimensions prior to installation. 1-19-2005 LS1025.3

Express Lavatory System SS-Series Model SS-3N/IR Model SS-3N/AST Model SS-3N/TT Model SS-3N/IR3 P L U M I N G F I X T U R E S Dimensions shown in parentheses are millimeters. MOUNTING FOR STANDARD AND WALL HUNG HEIGHTS ARE SHOWN 24-3/8" (619) 4" (102) 8" (203) 10" (254) 2-3/4" (70) 24-3/8" (619) A D D E F G H A 32" (813) 28-3/4" (730) 15" (381) C HOT SUPPLY COLD OR TEMPERED SUPPLY 5-5/8" (143) 18" (457) 27-1/2" (699) C 34" (864) RIM HEIGHT SEE CHART 1 24" (610) 23" (584) 3-1/2" (89) CHART 1 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS "A" FIXTURE STYLE THROUGH "H" 34" NONE STANDARD HEIGHT 34" NONE WALL HUNG 32" SUTRACT 2" TAS, GRADES 6 THROUGH 8/9 31" SUTRACT 3" JUVENILE HEIGHT SUTRACT 4" TAS, PRE-K THROUGH 5/6 CHART 2 CODE DESCRIPTION QTY. "A" 3/8" OWL WALL ANCHORS WITH A MINIMUM PULL OUT FORCE OF 1000 lbs. 2 "" 3/8" MAIN FRAME WALL ANCHORS WITH A MINIMUM PULL OUT FORCE OF 1000 lbs. 6 "C" 3/8" ASE FRAME WALL ANCHORS WITH A MINIMUM PULL OUT FORCE OF 1000 lbs. STANDARD FRAME OPTION ONLY. 2 "D" 1/2" NPT HOT/COLD SUPPLIES, STU OUT 2" FROM WALL. 2 "E" 1-1/2" NPT DRAIN, STU OUT 2" FROM WALL. 1 "F" 110V GFCI PROTECTED ELEC. OUTLET. I.R. AND TOUCH TIME ONLY. 1 "G" OPTIONAL HEATER, ELECTRIC OX LOCATION. 4" L X 4" W X 8" H - OPTION 1 1 "H" OPTIONAL HEATER, ELECTRIC OX LOCATION. 4" L X 4" W X 8" H - OPTION 2 1 radley Corporation reserves the right to make changes in design and material without formal notice and without incurring obligation. Verify all rough-in dimensions prior to installation. 1-19-2005 LS1025.4

P L U M I N G F I X T U R E S Model SS-3N/IR3 (attery Infrared Control) Standard Equipment owls owl with three lavatories, pedestal, stainless steel mounting frame (as described above), and the following fittings: P-trap; tailpiece; two flexible stainless steel supply connections; and Vernatherm thermostatic mixing valve with stop, strainer, check valves, and 110/24 VAC plug-in transformer (model SS- 3N/IR and SS-3N/TT only). atteries are included in Model SS-3N/IR3 only. Optional Equipment Express Lavatory System Thermostatic Electric Tankless Water Heater The optional tankless electric water heater is equipped with a microprocessing temperature control capable of maintaining outlet temperature accuracy of +/- 1 F. Factory preset at 105º F. Flow switch activates heater only on demand with 99% efficiency. For easy service, the heater features a replacement cartridge element. Model KW VAC Amps Temp Rise @ 1.5 GPM EX95TML 9.5 240/208* 40 43 F EX100TML 10 277 36 46 F * 240 volt can also be rated 208 volts with a 25% reduction in power. Activation Controls Infrared Sensor (Model SS-3N/IR) Each of the streamformers is controlled by a separate solenoid valve. Hands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from one stream former. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conical shaped transmitting beam, having a detection area adapted to, but not exceeding the bowl perimeter. The detection area projects forward 15 to each side and 15 below horizontal. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transformer as standard equipment: Solenoid - 24V, 50/60 Hz, 3/8" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low Voltage Transformer - Class II UL/CSA listed, 110/24 VAC plug-in transformer. Plugs into a standard GFCI electrical outlet. Air Valve Hand Control (Model SS-3N/AST) Each push-button pneumatically actuates a non-hold-open, air metering, single temperature valve with field adjustable timing from 0-45 seconds. Factory preset at 10 seconds. Each pushbutton activates one valve which, in turn, activates one station (streamformer). Touch Time Metering Control (Model SS-3N/TT) Each low voltage pushbutton actuates a non-hold-open, slow closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each pushbutton activates one valve, which, in turn, activates one station (streamformer). Touch Time controls water flow at each station through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. attery Operated Infrared Sensor (Model SS-3N/IR3) Each battery powered sensor uses a zone-focused infrared transmitting beam, creating a large detection area not exceeding the bowl perimeter. The sensor is not affected by varying skin tones or darkness. When hands enter the detection area, the sensor starts water flow by opening the valve electronically. When hands leave the detection area, the sensor stops the flow of water by closing the electronically activated solenoid valve. The 6-volt DC, electronically activated solenoid valve has few moving parts providing reliable operation that is unaffected by most chemicals and minerals often present in municipal water supplies. Each station is powered by a single lithium battery. attery type is Duracell DL 223A or equivalent (batteries included). Flow Control Rate Operating range 20-80 psi. Flow restrictor keeps flow rate constant at all pressures. Flow rate: 0.5 GPM. Sample Specification Express Model SS-3N/IR washing stations, with the centerline of each station located on centers, perpendicular to the mounting wall. Each hand washing station shall comply with ANSI and ADA accessibility standards. constructed of NAH Certified Terreon, complying with ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. owl and sprayhead cover finish shall be a decorative stone. LS1025.5 P.O. ox 309, Menomonee Falls, WI 53052-0309 Phone 1-800-RADLEY FAX 262-251-5817 http://www.bradleycorp.com

P L U M I N G F I X T U R E S Model SS-3N/IR3 (attery Infrared Control) each hand washing station shall have a streamformer served by an independent solenoid valve and actuated by an infrared sensing module with a single conical beam not exceeding the bowl perimeter. Each sensor shall have a 2-3 second turn-off delay; and automatic shut-off after 30-45 of continuous operation. and pre-wired and shall provide dry surface ledge above water spray area. lavatory system shall include plug-in transformer, all waste and supply connections to wall, and thermostatic mixing valve with stop, strainer, and check valves. Express Model SS-3N/AST washing stations, with the centerline of each station located on centers, perpendicular to the mounting wall. Each hand washing station shall comply with ANSI and ADA accessibility standards. constructed of NAH Certified Terreon, complying with ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. owl and sprayhead cover finish shall be a decorative stone. each hand washing station shall have a streamformer served by an independent air metering valve which is actuated by a push-button. and shall provide dry surface ledge above water spray area. lavatory system shall include all waste and supply connections to wall, and thermostatic mixing valve with stop, strainer, and check valves. Express Model SS-3N/TT washing stations, with the centerline of each station located on centers, perpendicular to the mounting wall. Each hand washing station shall comply with ANSI and ADA accessibility standards. constructed of NAH Certified Terreon, complying with ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. owl and sprayhead cover finish shall be a decorative stone. each hand washing station shall have a streamformer served by a pushbutton and independent Touch Time electronic metering valve. and pre-wired and shall provide dry surface ledge above water spray area. lavatory system shall include all waste and supply connections to wall, and thermostatic mixing valve with stop, strainer, and check valves. Express Model SS-3N/IR3 washing stations, with the centerline of each station located on centers, perpendicular to the mounting wall. Each hand washing station shall comply with ANSI and ADA accessibility standards. constructed of NAH Certified Terreon, complying with ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. owl and sprayhead cover finish shall be decorative stone. individual infrared controls powered by lithium batteries (batteries included) concealed inside a battery holder with electronically activated solenoid valve. and pre-wired and shall provide dry surface ledge above water spray area. lavatory system shall include all waste and supply connections to wall, and thermostatic mixing valve with stop, strainer, and check valves. * a lavatory system does not include items such as; fasteners, wall anchors, or other components that are job specific. LS1025.6 P.O. ox 309, Menomonee Falls, WI 53052-0309 Phone 1-800-RADLEY FAX 262-251-5817 http://www.bradleycorp.com

P L U M I N G F I X T U R E S Model SS-3N/IR3 (attery Infrared Control) Models Model No. SS-3N/IR SS-3N/AST SS-3N/TT SS-3N/IR3 Other Options: Description Express Lavatory System w/infrared Control Express Lavatory System w/air Valve Metering Express Lavatory System w/touch Time Metering Express Lavatory System w/attery Operated Infrared Control Model No. Description P-Trap: S-CHROME Single Chrome Plated P-Trap Waste Receptacle Holes: WRH Waste Receptacle Mounting Holes * * For more information on Terreon Waste Receptacles for the Express SS-Series see Document No. 1100. Standard Selections Must select one from each category Pedestal (Select One): STD Standard Frame (includes Scuff ase) WH Wall-Hung Frame Soap Dispenser (Select One): LSD Liquid Soap Dispenser (Two Integral Dispensers) NSD No Soap Dispenser Water Supply (Select One): TMA Vernatherm Thermostatic Mixing Assembly (Hot and Cold Supplies) TL Single Tempered Line Heaters Not Available with IR3 Activation HEAT277 Electric Tankless Water Heater, 277 volts HEAT240-208 Electric Tankless Water Heater, 240/208 volts Color of Terreon owl/sprayhead Cover (Select One): Standard Colors E-GRAY Empire Gray CHAR Charcoal Gray SAND Sandtrap GRAPH Graphite JADE Jade COLE Cobblestone ONE Mesa one PEP-WHT Peppered White DS-WHT Designer White LANNON Lannonstone WHT-SAND White Sand FIESTA Fiesta Designer Colors ARC-CHIP S-SAGE RIVER MYSTIC-M STAR-D COFFEE Arctic Chip Summer Sage Riverstone Mystic Moss Stardust Coffee ean Color of Access Panel/Sprayhead ody (Select One): GRAY Gray PUTTY Putty COAL Coal LS1025.7