SUPERCHILL Australia Pty Ltd

Similar documents
Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Privately held company

SECTION COOLING TOWERS

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

How about Savings in Time, Money, Energy and Longer Life?

SECTION COOLING TOWERS

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Evaporative Condensers

AT, MT & ES Series Super Low Sound Fan

QuadraFlow Cooling Tower

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

When you have a Bonaire ducted gas heater installed, you won t know it is winter until you look out the window Ducted Gas Heating Range

Efficient, Long Lasting Evaporative Condensers

What is Cooling S.Sen

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

VOLUME 2 (BOQ & Price Bid)

COUNTERFLOW COOLING TOWERS POLACEL CMDIF SERIES

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Closed Circuit Cooling Towers

Industrial cooling systems LT

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Who we are and what we do. The story of the world s leading manufacturer of axial impellers

What is a Closed circuit Cooling Tower (CCT)?

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOLING TOWERS EWK-D(A) TYPE

Remote Air Cooled Condensers C2 Series

JCseries EVAPORATIVE CONDENSER. engineering data

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Air Handling Units. Real HVACR people who understand your needs.

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

CONTENTS. B. System Design and Performance Requirements

Evaporative Condensers

PRODUCT RANGE: ROOFTOP PACKAGE

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

AIR HANDLING UNITS. Revision AG 16-07

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

DIVISION 15 MECHANICAL

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

DESCRIPTION OF COOLING TOWERS SERIES TAT

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

COMPANY PRESENTATION

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

TAH / TBH / TCH Series

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

Smoke extract fan SMHA HATCH

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Condensing Units CUS 15-60

Commercial Evaporative Air Conditioning


ECO-MASTER DRYER DRYING CONVEYING DRYING SEED PROCESSING ELECTRONIC SORTING STORAGE TURNKEY SERVICE

Series 1500 Cooling Tower Specification

Commercial Evaporative Cooling

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

/ Aquatower Fiberglass Cooling Tower /

Smarter Washing Solutions AGGST RM 150

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

ROOFTOP PACKAGED AIR CONDITIONERS

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

Bench Top Cooling Tower H893

AIR HANDLING UNITS MANDÍK

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

PCRAU0510. the. ultimate. heating and cooling guide

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Packaged Air Conditioning Custom Build Solutions

With the world-renowned SIGMA PROFILE

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

CP+ Gas & Oil Cabinet Heater Range

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

PFS Single stage axial fan The axial fan for modern boiler plants

Transformer oil coolers BETA & CETA

RAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw

Refrigeration Plant Information. We Speak Hockey 365

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

Transcription:

SUPERCHILL Australia Pty Ltd MODUPOL - Best Quality - Guaranteed Performance - Fibreglass Construction - Corrosion Proof - Compliance with AS3666 - All Applications - Made in Australia - Superchill is 100% Australian Owned SC Model Heavy Duty Mobile Unit Standard Low Noise Super Low Noise The right solution for any application Superchill & Sulzer* Cooling Towers * Former Sulzer-Escher Wyss GmbH is now AXIMA Refrigeration GmbH

Axima Cooling towers manufactured and used world-wide Wet bulb exceeds 5 C 10 C 15 C 20 C 25 C 30 C Licencees: You will find the addresses on www.axima.eu.com/refde (www.sulzerfrio.com) Made-to-measure by SUPERCHILL Australia, designed by the Axima Technology Corporation The World s leading Cooling Tower centre in Germany Axima, former Sulzer-Escher Wyss GmbH has been developing and manufacturing cooling towers since 1957. The reason for its success is that individually engineered solutions are offered for all the customer s requirements. Axima s research and development division also ensures the transformation of technical and scientific knowledge into customer friendly products and services. Please find more information about the products and the Axima technology group on the back page. Superchill Australia Pty Ltd 100% Australian owned was formed in 1997 on the basis of the former SULZER Australia Cooling Tower Division. As a dedicated Cooling Tower company, Superchill manufactures Axima (Sulzer) cooling towers in Australia for the local market as well as its own SC Cooling Tower range. All cooling towers are completely manufactured in-house in our Dandenong (Vic) factory, to the highest quality standards. Long service life with corrosionproof high quality cooling towers The corrosion-free plastic construction guarantees high quality and a long lifespan. Thanks to the wide range of models and capacities available, there is a type that is suitable for every requirement. Wide-ranging know-how, various accessories and possibilities to extend During design and tower selection Superchill s specialists also take into consideration further details such as noise levels and water treatment. We specialise in turnkey compact units which can be integrated in transportable standard containers. These are in demand at mine sites and for emergency situations when existing cooling systems break down. The wet bulb determines the achievable cold water The decisive factor for the cooling tower capacity is the wet bulb the relationship between ambient air and relative air humidity. Wet type cooling towers can reach a of approx. 2 to 3 C above this value. In Australia, the following wet bulb s are usually used for design conditions: Sydney 24 C, Melbourne 21.5 C, Adelaide 23 C, Perth 23 C, Brisbane 26 C, Hobart 19.5 C, Townsville 27.5 C. (Source: Airah Handbook, for critical processes, Summer, 0800-1800) On the above world map the wet bulb s are indicated in 5 C steps. 2

Cooling towers save up to 97% Water Just like air, water is one of our most vital and precious resources. The economical use of this natural resource is therefore of major importance. Cooling towers are an economical and ecological way of re-cooling: up to 97 % of water can be saved compared to continuous-flow cooling. Air out Hot water inlet Water cooling systems Depending on the required cooling water we compare various systems. At cooling water s (in Australia) below approximately + 25 C generally refrigerating machines (chillers) are used and above this cooling towers. Types of cooling towers Cooling towers are distinguished according to various criteria: 1. The force of the airstream: Naturally ventilated cooling towers (natural draught cooling towers) Artificially ventilated cooling towers (mechanical draught cooling tower). Fans may be of the induced or forced draught type design. Operating principle of a wet-type cooling tower (EWK range) Fill material Ambient air in Cold water outlet 2. The relationship of the airstream to the water flow: Counter-flow cooling towers Cross-flow cooling towers Combinations of these two designs 3. Types of fill material: Open circuit cooling towers in which the water is cooled by direct contact with the surrounding air (wet-type cooling towers) Closed circuit cooling towers the medium to be cooled has no direct contact with cooling water Hybrid cooling towers a combination of open and closed systems Operating principle of cooling towers Wet type cooling towers reach s below the ambient. Significant for this is the wet bulb see page 2 for more details. Wet-type cooling towers The water to be cooled is sprayed and trickled over fill material by a water distribution system which, owing to its shape and position, guarantees high water and air contact times. At the same time, the surrounding air is drawn through the tower in counter-flow, thereby evaporating a small part of the circulating water. The heat required for this evaporation process is drawn off by the cooling water and provides the majority of the cooling capacity. The remainder of the cooling capacity is created by the convection of the warm water to the colder air. The re-cooled water collects in the basin from where it is fed back to the cooling points. The saving in terms of cooling water in comparison with continuous flow cooling can be up to 97% of the circulation water, the remainder being required to compensate for the water loss due to evaporation and bleed-off. Closed circuit cooling towers The medium to be cooled flows through a closed heat exchanger and does not come into direct contact with the surrounding air. Water is trickled over the heat exchanger by a water distribution system (secondary circuit). Dry-type coolers The medium to be cooled flows through a heat exchanger just as for closed cooling towers. Heat is removed by means of convection to the surrounding air thus allowing the system to attain cooling water s in excess of the ambient. 3

Cooling towers with long service life In-house production to a high level of quality In the assembly section the cooling towers are pre-assembled into transportable units. Spray coating of large-surface cooling tower parts made of FRP material The components are made ready for assembly A cooling tower for every application Choosing the "right" cooling tower is vital and should be based on computer analysis of the necessary criteria: cooling capacity, energy consumption and noise level. Our standard range of cooling towers covers almost all possible applications. Special models meet very particular demands for the cooling plant. Both experience and in-house fabrication are considerable advantages enabling Superchill to meet client s specific needs. Global planning On request, our project engineers will analyse the requirements, plan the details and supervise the installation, commissioning and operation. Fast installation Well and efficient planned preparatory work reduces installation time on site to a strict minimum. A vital advantage if your production plant has to be shut down during the installation phase. Factory assembly of cooling towers in our works saves time at the place of erection Years of experience in cooling tower construction In 1957 Sulzer (now AXIMA) built the first cooling tower prototype. Since then our design and manufacturing philosophy has not changed. All our cooling tower components are developed, tested and manufactured inhouse. This is the only way we can guarantee our customers a high quality, state-of-the-art product. Development and testing New product lines and one-off projects alike are developed in our design office. Existing lines are constantly revised and upgraded to optimise performance, energy consumption and operating noise levels. New research is incorporated into the cooling tower design programs and the results are subject to stringent testing on our own test stands. Reliable specifications are an essential prerequisite for the efficient planning and economical operation of cooling towers. Materials and manufacture Fibreglass reinforced polyester has proved an excellent construction material over decades of use in the manufacture of cooling towers. The material is heat resistant and practically indestructible some of our cooling towers have been in operation for over 30 years. However, the processing of large plastic components requires a good deal of specialist knowledge. In order to ensure that nothing is left to chance we have developed our own assembly line which produces finished cooling tower casings. Prompt service Our comprehensive after sales network provides a quick and efficient maintenance and spares service. We also offer a maintenance contract which ensures the regular servicing of your cooling system. AXIMA certifications Proven quality for technology and environment DIN/ ISO 9001 Quality Assurance Certification CEE-Eco-Audit Environmental Management System approved according to CEE Regulations Water Protection Act A specialised company within the meaning of the Water Resources Policy Act SUPERCHILL certification ISO 9001 QEC11383 Quality Assurance Certification 4

The right cooling tower for any application Superchill Manufacturing range view EWK range Induced draught counter flow open circuit wet-type cooling towers with axial fan in compact corrosion-proof fibreglass design. Water flowrates from 2 to 550 m 3 /h Page 6 / 7 MODUPOL range Continuation of the EWK range with very high specific cooling capacities due to modular construction. Water flowrates from 100 to 3600 m 3 /h Page 10 / 11 EWB range Open wet-type cooling tower with induced draught axial fan in corrosionprotected fibreglass design. Extendable construction can easily be upgraded. Water flowrates per unit from 65 to 2200 m 3 /h Page 12 / 13 Special cooling towers Closed circuit cooling towers: Cooling towers with closed primary circuit for cooling various liquids, either induced draught or forced draught. Page 16 EWK-D range Open wet-type cooling tower with forced draught centrifugal fans, low profile and low noise level. Water flow rate from 7 to 270 m 3 /h Page 14 / 15 Waste water cooling towers: Wet type cooling towers without fill material for cooling waste waters containing solids. Page 16 Crossflow cooling towers: Page 16 Cell cooling towers: High efficiency concrete cooling towers particularly for energy management. Information upon request. Compact and container units Compact units ready for connection on base frame or in container. The units are transportable and ready for use, immediately after pipework is connected at site. Page 15 SC Range cooling towers Induced draught counter flow open circuit wet-type cooling towers with axial fan in compact corrosion-proof fibreglass design. Water flowrates from 2 to 95 m 3 /h Page 8 / 9 Cooling tower fill, PP for up to 80 C (or HT up to 100 C) Water treatment units Information upon request. Heavy duty (mobile) Cooling Towers and Bulk Air Coolers Specially suited for surface and underground mine applications and other heavy duty environments. 5

EWK Compact all-composite, corrosion-proof, wet-type cooling towers Cooling tower components: Casing The casing which can be supplied with or without a water collecting basin is made of fibreglass reinforced polyester with stainless steel screw fittings. The standard colour is sky blue. Other colours are also available. Axial fan The fibreglass reinforced plastic or aluminium blades can be adjusted while the fan is at standstill. In models up to and including the EWK 900 the axial fan and the electric motor are directly connected. In models from the EWK 1260 upwards the fan is driven by geared motors. A protective grid is fitted above the fan. Drift eliminator High performance, tested and approved drift eliminators prevent water droplets being carried over by the air stream and minimize drift losses as required by AS 3666. Water distribution system The water distribution pipes are fitted with self-cleaning, none-clogging cone spray nozzles, made in ABS material. Fill material The fill material is made of corrosionproof, heat resistant polypropylene. Various grades or other materials are available to suit your application. Louvres The plastic air inlet louvres prevent water splashing. They are easy to remove for inspection and cleaning. Strainer basket The strainer basket is mounted in the basin upstream of the outlet and prevents foreign materials from entering the water circuit. Float valve The float valve controls the supply of make-up water. Quick fill, overflow, drain Fittings are included as standard. Optional Accessories Exhaust silencer Sound-absorbing matting to reduce water impact noise level in basin Aluminium ladder with protective cage and platform with railing External water distribution pipe Thermostat to regulate fan speed by monitoring of the cold water Heating system to keep water outlet zone free of ice in winter Thermostat to regulate heating by monitoring of the cold water Water treatment control unit Variable speed control for fan motor or two-speed fan motors for energy saving and noise reduction Induced draught cooling towers type EWK 450 for cooling injection moulding machines Special advantages of the EWK range Exact capacity selection thanks to the wide range of models available. The perfect cooling tower can be chosen to meet your specific requirements Corrosion-proof, durable, lightweight construction thanks to the all-plastic fibreglass reinforced polyester design Low energy consumption and low maintenance through the use of induced draught fans Extended maintenance intervals Simple and inexpensive installation thanks to our factoryassembled, transportable modules Attractive design in a choice of RAL colours allows your cooling tower to blend in with existing buildings Five induced draught cooling towers type EWK 900 for process cooling in food industry 6

Technical data Data for of the EWKrange cooling tower range Protective grid Fan with motor Drift eliminator Water distribution pipe with cone spray nozzles Fill material Cooling tower casing Inspection hatch Air inlet louvres Water collecting basin Galvanized steel base frame Cross-Sectional view of an EWK tower EWK Water flowrate Rated cooling capacity Motor- Dimensions Weight in m 3 /h in kw at t f = 20 C rating Length Width Height Empty In service min max 32/26 C 40/25 C kw mm mm mm kg kg 036/03 2 11 35 50 0.33/0.1 615 615 2030 40 100 036/06 2 11 45 65 0.33/0.1 615 615 2030 50 120 064/03 3 20 65 85 0.55/0.1 817 817 2473 100 220 064/06 3 20 80 110 0.55/0.1 817 817 2473 110 230 064/09 3 20 90 135 0.55/0.1 817 817 2473 115 250 144/03 7 45 140 190 1.5/0.35 1226 1226 3223 260 570 144/06 7 45 175 250 1.5/0.35 1226 1226 3223 275 610 144/09 7 45 200 295 2.2/0.55 1226 1226 3223 290 660 230/06 11 70 275 390 2.2/0.55 1620 1620 3168 380 1200 230/09 11 70 320 465 2.2/0.55 1620 1620 3468 400 1300 324/03 16 100 320 435 3.0/0.50 1825 1825 3673 575 1330 324/06 16 100 400 555 3.0/0.50 1825 1825 3673 610 1420 324/09 16 100 440 665 3.0/0.50 1825 1825 3673 645 1520 450/06 20 135 555 800 4.0/0.80 2220 2220 3683 850 2800 450/09 20 135 630 935 5.5/1.20 2220 2220 3683 900 3000 680/06 35 200 800 1140 5.5/1.40 3110 2360 4403 1350 4400 680/09 35 200 920 1350 9.5/2.40 3110 2360 4703 1450 4700 900/06 45 270 1100 1555 9.5/2.40 4345 2152 4869 1500 5500 900/09 45 270 1250 1840 11.0/3.0 4345 2152 4869 1600 5800 1260/06 65 380 1530 2175 11.0/3.0 4288 3138 5247 2325 8000 1260/09 65 380 1740 2590 14.0/3.5 4288 3138 5247 2450 8400 1800/06 90 540 2190 3110 18.5/4.5 4288 4336 5390 3225 11200 1800/09 90 540 2490 3710 22.0/5.5 4288 4336 5390 3400 11800 The rated cooling capacities given in the table apply to water cooled from 32 C to 26 C and resp. 40 C to 25 C at a wet-bulb of 20 C. The minimum and maximum water flowrates do not refer to the rated cooling capacities. For other design requirements please see the Quick Selection Chart on page 18 or contact us. Technical modifications reserved. 7

SC Compact all-composite, corrosion-proof, wet-type cooling towers designed in Australia Cooling tower components: Casing The casing which can be supplied with or without a water collecting basin is made of fibreglass reinforced polyester with stainless steel screw fittings. The standard colour is grey. Other colours are also available. Axial fan The fibreglass reinforced plastic blades can be adjusted while the fan is at standstill. The axial fan and the electric motor are directly connected. A protective grid is fitted above the fan. Drift eliminator High performance, tested and approved drift eliminators prevent water droplets being carried over by the air stream and minimize drift losses as required by AS 3666. Water distribution system The water distribution pipes are fitted with self-cleaning, non-clogging plastic spray nozzles. Fill material The fill material is made of corrosionproof, heat resistant polypropylene. Various grades or other materials are available to suit your application. Louvres The plastic air inlet louvres prevent water splashing. One side wall, including louvre, is completely removable for easy inspection and cleaning. Strainer basket The stainless steel strainer basket is mounted in the basin upstream of the outlet and prevents foreign material from entering the water circuit. Float valve The float valve controls the supply of make-up water. Quick fill, overflow, drain Fittings are included as standard. Optional Accessories Exhaust silencer Aluminium ladder Thermostat to regulate fan speed by monitoring of the cold water Heating system to keep water outlet zone free of ice in winter Thermostat to regulate heating by monitoring of the cold water Water treatment control unit Variable speed control for fan motor or two-speed fan motors for energy saving and noise reduction Water circulation pump Induced draught cooling towers type SC 35 and SC 45. Front panel removed for inspection Special advantages of the SC range Exact capacity selection thanks to the wide range of models available. The perfect cooling tower can be chosen to meet your specific requirements Corrosion-proof, durable, lightweight construction thanks to the all-plastic fibreglass reinforced polyester design Low energy consumption and low maintenance through the use of induced draught fans Extended maintenance intervals Simple and inexpensive installation thanks to our factoryassembled, transportable modules Attractive design in a choice of colours allows your cooling tower to blend in with existing buildings SC 75 cooling towers 8

Technical data Data for of the EWK SC cooling range tower range Tower Structure: Casing manufactured from high grade, high thermal resistant fibre reinforced polyester (FRP), and is durable, lightweight and corrosion free PVC Drift Eliminators: Designed to alter direction of airflow to provide maximum drift loss protection as required by AS 3666 Easy Access: to comply with AS 3666 the Superchill SC range is designed for fast and simple dismantling of interior components PVC Louvres: Designed for fast & simple removal. To comply with AS 3666, louvres configuration prevents splash out and minimises entry of light into the cold water basin Cold Water Basin: Single piece mould design so all surfaces slope to drain to comply with AS 3666 Exploded view of the SC Cooling Tower Protective Fan Grid, Mechanical Support & Hardware: Manufactured from stainless steel to conform to Superchill high design standards Strainer: prevents foreign materials from entering system, manufactured in stainless steel Fittings: include drain, inlet outlet, make-up, overflow and quick fill as standard Fan Motor: IP56 protection. 6 pole for low noise. Fan: High efficiency glass reinforced polypropylene fan with Adjustable pitch Fan Cylinder: Designed to provide optimum airflow and reduced air turbulence whilst providing even airflow through PVC fill Water Distribution: Consists of PVC header pipe & clog resistant spray nozzles PP Cooling tower heat transfer media: The Wet Deck consists of high efficiency Polypropylene fill-pack, configured to provide maximum air to water contact and low air pressure drop, to ensure efficient heat transfer and minimise power requirements Internal Surfaces: Smooth gel coat finish in basin to allow for easy cleaning SC Water flowrate Rated cooling capacity Motor- Dimensions Weight Tower in m 3 /h in kw at t f = 20 C rating Length Width Height Empty In service min max 32/26 C 40/25 C kw mm mm mm kg kg SC 10 2 11 35 48 0.16 720 740 1945 50 105 SC 15 2 11 45 65 0.67/0.1 720 740 1945 50 105 SC 20 6 25 80 105 0.55/0.1 1060 1060 2250 150 300 SC 35 6 25 101 145 0.75/0.2 1060 1060 2250 150 300 SC 45 8 32 135 195 0.75/0.2 1075 1360 2530 200 480 SC 60 11 43 180 260 1.1/0.25 1410 1410 2510 225 520 SC 75 13 54 225 325 2.2/0.5 1620 1320 2530 325 660 SC 95 16 68 285 405 2.2/0.5 1680 1620 2740 400 770 SC 110 16 68 325 475 3.0/0.75 1680 1620 2740 450 850 SC 115 L 20 81 335 485 3.0/0.75 1930 1690 2755 480 1045 SC 135 L 25 95 400 580 4.0/1.0 1930 1940 3000 620 1455 SC 135 25 100 410 590 4.0/1.0 1930 1940 3450 620 1455 SC 150 25 100 475 695 5.5/1.3 1930 1940 3750 720 1555 SC 180 in development SC 220 in development The rated cooling capacities given in the table apply to water cooled from 32 C to 26 C and resp. 40 C to 25 C at a wet-bulb of 20 C. The minimum and maximum water flowrates do not refer to the rated cooling capacities. For other design requirements please see the Quick Selection Chart on page 18 or contact us. Technical modifications reserved. 9

MODUPOL Open, all-composite, corrosion-proof cooling towers with axial suction fan Cooling tower components: Casing The modular casing which is made of fibreglass reinforced polyester, comes in three models with stainless steel screw fittings. The standard colour is sky blue. Other colours are also available. Axial fan The fibreglass reinforced plastic or aluminium blades can be adjusted while the fan is at standstill. The fan is driven by a one- (or two)-speed geared motor, and preferably controlled with a variable speed drive. A protective grid is fitted above the fan. Two cooling towers MODUPOL EWK 4500 with special fan and both intake and exhaust silencers for cooling process water in a paper mill Drift eliminator High performance, tested and approved drift eliminators prevent water droplets being carried over by the air stream and minimize drift losses as required by AS 3666. Water distribution system The water distribution pipes are fitted with self-cleaning, non-clogging cone spray nozzles made in ABS material. Fill material The fill material is made of corrosionproof, heat resistant polypropylene. Various grades or other materials are available to suit your application. Louvres The plastic air inlet louvres prevent water splashing. They are easy to remove for inspection and cleaning. Optional Accessories Exhaust silencer Intake silencer Sound-proof matting to reduce water impact noise level in basin Aluminium ladder with protective cage, platform with railings and direct access to geared motor External water distribution pipe Thermostat and variable speed drive control unit to regulate fan speed by monitoring of the cold water Heating system to keep water outlet zone free of ice in winter Thermostat to regulate heating by monitoring of the cold water Float valve to control supply of makeup water Strainer for water outlet Special advantages of the MODUPOL range Corrosion-proof, durable, lightweight construction thanks to the self-supporting all-plastic fibreglass reinforced polyester design Very high cooling capacity for cooling up to 3600 m 3 /h of water Individual "kit" solutions thanks to the range of models and modular design. Optional water collecting basin Low energy consumption and low maintenance through the use of induced draught fans Extended maintenance intervals Simple and inexpensive installation thanks to the individual, factory-assembled modules Attractive design in a choice of RAL colours allows your cooling tower to blend in with existing buildings Three cooling towers MODUPOL EWK 4500, erected in line, with air intake and exhaust silencer in automotive industry (AUDI Germany) 10

Technical data for the MODUPOL cooling tower range Fan with motor Protective grid Drift eliminator Water distribution pipe with cone spray nozzles Fill material Version 1 MODUPOL with air intake frame and sitebuilt concrete basin Fan inlet cowling Inspection hatch Cooling tower casing Air intake louvres Site-built concrete basin MODU- Water flowrate Rated cooling capacity Motor- Dimensions* Weight* POL in /h in kw at t m3 f = 20 C rating Length Width Height Empty In service EWK min max 32/26 C 40/25 C kw mm mm mm kg kg 2100/06 105 630 2700 3860 14/3.5 4622 4740 5550 3700 5700 2100/09 105 630 3090 4560 18/4.5 4622 4740 5550 3700 5700 3100/06 155 930 3980 5700 22/5.5 4622 7040 5895 4900 7400 3100/09 155 930 4560 6740 30/7.5 4622 7040 5895 4900 7400 4500/06 225 1350 5780 8280 36/9.0 6950 7040 6355 7200 10900 4500/09 225 1350 6620 9780 36/9.0 6950 7040 6355 7200 10900 6100/06 310 1860 7840 11250 50/10.0 9226 7040 7550 10500 15700 6100/09 310 1860 9020 13160 58/12.6 9226 7040 7550 10500 15700 4200/06 210 1260 5400 7720 2x14/3.5 9280 4740 5500 7300 10700 4200/09 210 1260 6180 9120 2x18/4.5 9280 4740 5500 7300 10700 6200/06 310 1860 7960 11400 2x22/5.5 9280 7040 6195 9800 14800 6200/09 310 1860 9120 13480 2x30/7.5 9280 7040 6195 9800 14800 9000/06 450 2700 11560 16560 2x36/9.0 13900 7040 6655 14300 21900 9000/09 450 2700 13240 19560 2x36/9.0 13900 7040 6655 14300 21900 12200/06 610 3660 15610 22340 2x50/10.0 18500 7040 7850 21200 31600 12200/09 610 3660 18030 25810 2x58/12.6 18500 7040 7850 21200 31600 one cell two cells Version 2 MODUPOL - Standard version with site-built concrete basin and air intake through top of basin Air in Air in Version 3 MODUPOL with air intake frame and integrated fibreglass reinforced plastic water collecting basin * Dimensions and weights shown are for Version 1. Specifications for Versions 2 and 3 are available upon request. The rated cooling capacities specified in the table apply to water cooled from 32 C to 26 C resp. from 40 C to 25 C at a wet-bulb of 20 C. The minimum and maximum water flowrates do not refer to the rated cooling capacities. For other design requirements please see the Quick Selection Chart on page 18 or contact us. Technical modifications reserved. 11

EWB Extendable corrosion-protected, wet-type cooling towers Cooling tower components: Casing The casing, which can be supplied with or without a water collecting basin, consists of a galvanised profiled steel frame, panels and supports for the fill material. The panels are made of profiled fibreglass reinforced polyester. The standard colour is sky blue. Other colours are also available. Cooling tower deck The walk-on cooling tower deck comes in two versions: non-slip fibreglass or aluminium plates. Axial fan The hydrodynamic fibreglass reinforced plastic or aluminium blades can be adjusted while the fan is at a standstill. A protective grid is fitted above the geared motor-driven fan. Drift eliminator High performance, tested and approved drift eliminators prevent water droplets being carried over by the air stream and minimize drift losses as required by AS 3666. Water distribution system The water distribution pipes are fitted with self-cleaning, non-clogging cone spray nozzles, made in ABS material. Fill material The fill material is made of corrosionproof, heat resistant polypropylene. Various grades or other materials are available to suit your application. Louvres The plastic air inlet louvres prevent water splashing. They are easy to remove for inspection and cleaning. Water collecting basin The water collecting basin is usually a site-built concrete basin. It is possible to offer a fibreglass reinforced polyester basin. Optional Accessories Outlet strainer basket Intake silencer Sound-proof matting to reduce water impact noise level from basin Exhaust silencer Aluminium ladder with protective cage Handrails at top of tower Thermostat to regulate fan speed by monitoring of the cold water Heating system to keep water outlet zone free of ice in winter Thermostat to regulate heating in function of the cold water Walk-on protective grid for maintenance EWB 5750 cooling tower in a Steel manufacturing Plant in SA Soft starter or VSD or reverse running protection for the fans Oil level control Special advantages of the EWB range Flexible extension for future expansion needs and exact sizing of the cooling units thanks to the modular design and wide range of models Corrosion-protected, durable, light-weight construction thanks to hard-wearing corrosion-resistant plastic/steel industrial design Low energy consumption and low maintenance through the use of induced draught fans and lowspeed geared motors Easy access for maintenance and inspection work thanks to the removable side panels and walk-on cooling tower deck Extended maintenance intervals A range of RAL colours is available to allow your cooling tower to blend in with existing buildings A new twin-cell cooling tower EWB 4600 in front of several older EWB cooling towers, for cooling process water in a Titanium Dioxide Plant in WA 12

Technical data for the EWB cooling tower range Fan with motor Water distribution pipe with cone spray nozzles Drift eliminator Fill material Concrete basin or fibreglass reinforced plastic water collecting basin Protective grid Cooling tower panels Air intake louvres Cross-sectional view of an EWB tower EWB Water flowrate Rated cooling capacity Motor- Dimensions Weight in m 3 /h in kw at t f = 20 C rating Length Width Height Empty In service min max 32/26 C 40/25 C kw mm mm mm kg kg 1300/06 65 390 1700 2400 11/3.0 3700 3700 4900 2900 3900 1300/09 65 390 1950 2850 14/3.5 3700 3700 4900 2900 3900 1730/03 85 520 1800 2400 14/3.5 4900 3700 4900 3500 4900 1730/06 85 520 2250 3200 22/5.5 4900 3700 4900 3500 4900 1730/09 85 520 2550 3800 22/5.5 4900 3700 4900 3500 4900 2300/03 115 690 2350 3200 22/5.5 4900 4900 5100 4700 6600 2300/06 115 690 2950 4200 22/5.5 4900 4900 5100 4700 6600 2300/09 115 690 3400 5000 22/5.5 4900 4900 5100 4700 6600 2875/03 140 865 2950 3950 22/5.5 6100 4900 5150 6800 9200 2875/06 140 865 3700 5300 30/7.5 6100 4900 5150 6800 9200 2875/09 140 865 4250 6250 30/7.5 6100 4900 5150 6800 9200 3600/06 180 1080 4650 6600 36/9.0 6150 6150 5100 8600 11500 3600/09 180 1080 5300 7900 36/9.0 6150 6150 5100 8600 11500 3460/03 170 1040 3300 4600 2 x 14/3.5 7350 4900 4900 6800 9500 3460/06 170 1040 4100 5850 2 x 22/5.5 7350 4900 4900 6800 9500 3460/09 170 1040 4650 6900 2 x 22/5.5 7350 4900 4900 6800 9500 4600/03 230 1380 4700 6350 2 x 22/5.5 9750 4900 5100 8800 12300 4600/06 230 1380 5900 8450 2 x 22/5.5 9750 4900 5100 8800 12300 4600/09 230 1380 6750 10050 2 x 22/5.5 9750 4900 5100 8800 12300 5750/03 285 1730 5900 7900 2 x 22/5.5 9750 6100 5150 11500 16300 5750/06 285 1730 7400 10550 2 x 30/7.5 9750 6100 5150 11500 16300 5750/09 285 1730 8450 12500 2 x 30/7.5 9750 6100 5150 11500 16300 7200/06 360 2160 9250 13250 2 x 36/9.0 12250 6150 5100 16000 21200 7200/09 360 2160 10600 15650 2 x 36/9.0 12250 6150 5100 16000 21200 one cell two cells The rated cooling capacities given in the table apply to water cooled from 32 C to 26 C and resp. 40 C to 25 C at a wet-bulb of 20 C. The minimum and maximum water flowrates do not refer to the rated cooling capacities. For other design requirements please see the Quick Selection Chart on page 18 or contact us. Technical modifications reserved. 13

EWK-D Low-noise, wet-type, corrosion-proof cooling tower in all-composite design Cooling tower components: Casing The casing and water collecting basin are made of fibreglass reinforced polyester. The standard colour is sky blue. Other colours are also available. A stainless steel filter is fitted upstream of each water outlet. An inspection hatch provides access for float valve adjustment and filter and water collecting basin cleaning. Centrifugal fan A high performance, double-action, low-noise centrifugal fan made of galvanised steel plate. The fan is driven by a three-phase motor and V-belts. All moving parts are protected by guards. Drift eliminator High performance, tested and approved drift eliminators prevent water droplets being carried over by the air stream and minimize drift losses as required by AS 3666. Water distribution system The water distribution pipes are fitted with self-cleaning, non-clogging cone spray nozzles, made in ABS material. Fill material The fill material is made of corrosionproof, heat resistant polypropylene. Various grades or other materials are available to suit your application. Vibration isolated fan motor unit The fan motor unit is totally vibrationisolated from the main structure and connected with flexible connections and vibration dampers. This prevents the EWK-D 324 and EWK-D450 forced draught cooling towers transmission of structure-borne noise. Optional Accessories Sound attenuation: Fan cladding in the form of an air intake chamber, intake and exhaust silencers with fibreglass reinforced polyester casing Flexible ducting for connecting the air supply and evacuation ducts Louvre flaps at intake and exhaust Thermostat to regulate the fan speed by monitoring the cold water Heating system to keep water outlet zone free of ice in winter Thermostat to regulate the heating by monitoring the cold water External water distribution pipe Water treatment control unit Variable speed control for fan motor or two-speed fan motors for energy saving and additional noise reduction Special advantages of the EWK-D range Low-noise operation aided by the use of centrifugal fans and totally enclosed water casing Super Low Noise design by further reduction of noise emission with sound attenuators Simple and inexpensive installation thanks to our factoryassembled modules built as fully completed skid-mounted units Exact thermal capacity selection thanks to the wide range of models available allowing selection of the perfect cooling tower to meet your specific requirements Corrosion-proof, durable, lightweight construction thanks to the all-plastic fibreglass reinforced polyester design No water splashing and totally waterproof housing thanks to the enclosed fibreglass reinforced polyester casing (No air intake louvres are necessary) Forced draught cooling towers EWK-DA 680 with air intake and exhaust silencer in a noise sensitive area Suitable for use in enclosed spaces due to low noise emission levels and low overall heights Easy maintenance due to access from ground level and extended maintenance intervals A range of colours is available 14

Technical data for the EWK-D cooling tower range Inspection hatches Outlet silencer Cooling tower casing Drift eliminator Flexible connection Centrifugal fan Inlet silencer Water distribution pipe with ABS cone spray nozzles Fill material V-belt drive Inspection hatch Water collecting basin Motor Cross-sectional view of an EWK-DA tower Galvanized base frame EWK-D Water flowrate Rated cooling capacity Motor- Dimensions Weight Standard in m 3 /h in kw at t f = 20 C rating Length Width Height Empty In Service design min max 32/26 C 40/25 C kw mm mm mm kg kg 144-06 7 45 175 250 1.0/3.8 2440 1310 2303 450 1100 144-09 7 45 200 295 1.4/5.5 2440 1310 2603 450 1100 225-06 11 70 275 390 1.4/5.5 2900 1620 2303 620 1610 225-09 11 70 320 465 1.4/5.5 2900 1620 2603 620 1610 324-06 16 100 400 555 2.2/9 3450 1900 2303 880 2380 324-09 16 100 440 665 3.0/11 3450 1900 2603 880 2380 450-2 20 135 525 760 2.2/9 3960 2125 2653 770 2870 450-3 20 135 575 870 3.5/14 3960 2125 2653 770 2870 680-2 35 200 820 1170 3.0/11 5096 2280 2693 1500 4300 680-3 35 200 950 1390 3.5/14 5096 2280 2693 1500 4300 930-2 45 280 1130 1600 3.5/14 6330 2280 2693 2100 5500 930-3 45 280 1280 1890 5.5/20 6330 2280 2693 2100 5500 EWK-DA Water flowrate Rated cooling capacity Motor- Dimensions Weight with sound in m 3 /h in kw at t f = 20 C rating Length Width Height Empty In Service attenuation min max 32/26 C 40/25 C kw mm mm mm kg kg 144-06 7 45 175 250 1.4/5.5 3705 1310 3233 800 1510 144-09 7 45 200 295 1.4/5.5 3705 1310 3533 800 1510 225-06 11 70 275 390 1.7/7.0 4110 1620 3233 1230 2290 225-09 11 70 320 465 1.7/7.0 4110 1620 3533 1230 2290 324-06 16 100 400 555 3.0/11 4590 1885 3233 1530 3130 324-09 16 100 440 665 3.5/14 4590 1885 3533 1530 3130 450-2 20 135 525 760 3.5/14 5114 2125 3703 1500 3700 450-3 20 135 575 870 5.5/20 5114 2125 3703 1500 3700 680-2 35 200 820 1170 3.5/14 6266 2280 4033 2450 5410 680-3 35 200 950 1390 5.5/20 6266 2280 4033 2450 5410 930-2 45 280 1130 1600 6.0/24 7540 2280 4033 3250 6850 930-3 45 280 1280 1890 7.0/28 7540 2280 4033 3250 6850 The rated cooling capacities given in the table apply to water cooled from 32 C to 26 C and resp. 40 C to 25 C at a wet-bulb of 20 C. The minimum and maximum water flowrates do not refer to the rated cooling capacities. For other design requirements please see the Quick Selection Chart on page 18 or contact us. Technical modifications reserved. 15

Special cooling towers EWK-C Closed circuit cooling tower, induced draught EWK-DC Closed circuit cooling tower, forced draught Induced-draught, wet type cooling tower in corrosion-proof plastic construction with closed primary circuit for recooling various liquids. The internal heat exchanger is made of hot dipped galvanised steel tube bundles with smooth wall tubes or finned tubes for low-steam hybrid operation. Copper tube or SS bundles can also be supplied. Forced-draught wet type cooling tower with identical features to the induced draught model. The low-noise, high performance centrifugal fan is manufactured in galvanised steel and is driven by means of a three-phase motor and V-belts. EWA Wet-type cooling tower for waste water This cooling tower can cope with waste waters with high solid or fat concentration, with acids, lyes or residues from chemical processes. Also sea or brackish water can be cooled. The standard cooling tower is built without fill material. Water is distributed by natural flow through main and secondary channels with plastic splash plates. EWX Low-noise cross-flow cooling tower A low-noise induced draught cooling tower in cross-flow construction with easy access for maintenance work. Air inlet through short side only, so that several cooling towers can be erected in line for increasing the capacity. 16

Compact and container units Turnkey compact units, the economical alternative Compact units are suitable for small- and medium-scale operations. All components are tubed and cabled on a galvanised base frame. Only the connections to the cooling tower and consumer have to be completed. Another version is compact units integrated in containers. These containers can easily be transported and replace the need for a plant room. Potential plant diagrams for single and dual circuit systems 1 Cooling tower 2 Pumps 3 Fresh water supply 4 Emergency water supply 5 Level control 6 Partial current filter 7 Differential pressure gauge 8 Rinse water line 9 Controlled volume pump 10 Conductivity meter 11 ph meter 12 Desalting unit 13 Outlet channel 14 Drainage 15 Storage basin 16 Water treatment 17 Cooling points 18 Overflow valve 19 Chemical dosing tank 20 Thermostat 17

Quick Selection Chart Temperatures in deg C Hot Water 35 35 35 35 35 35 35 35 35 35 37 38 Cold Water 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 32 33 Wet Bulb 19 20 21 22 23 24 25 25.5 26 27 27 28 EWK & SC towers Water flow in l/s SC10 2.4 2.2 2.0 1.9 1.7 1.5 1.4 1.3 1.2 0.9 1.7 1.8 SC15 2.6 2.5 2.4 2.2 2.0 1.8 1.6 1.5 1.4 1.2 2.0 2.1 SC20 5.3 4.9 4.6 4.2 3.9 3.5 3.1 2.8 2.6 2.1 3.9 4.1 SC35 6.1 6.1 5.6 5.2 4.8 4.3 3.9 3.6 3.4 2.8 4.8 5.1 SC45 8.1 8.1 7.5 7.0 6.4 5.8 5.2 4.8 4.5 3.8 6.5 6.7 SC60 10.8 10.8 10.0 9.3 8.5 7.7 6.9 6.4 6.0 5.0 8.6 9.0 SC75 13.5 13.5 12.6 11.6 10.6 9.6 8.6 8.0 7.5 6.3 10.8 11.2 SC95 16.9 16.8 15.7 14.5 13.3 12.1 10.8 10.0 9.3 7.8 13.4 14.0 SC110 16.9 16.9 16.9 16.2 15.0 13.7 12.2 11.5 10.7 9.1 15.1 15.8 SC115 20.3 20.2 18.8 17.4 16.0 14.5 12.9 12.0 11.2 9.4 16.1 16.9 SC135 27.0 24.2 22.6 20.9 19.2 17.4 15.5 14.5 13.4 11.3 19.4 20.2 SC150 27.0 27.0 27.0 25.8 23.9 21.9 19.7 18.6 17.2 15.0 24.4 25.8 EWK450/06 36.8 36.6 34.2 31.6 29.0 26.3 23.4 21.9 20.3 17.1 29.3 30.6 EWK450/09 36.8 36.8 36.8 35.4 32.6 29.7 26.6 25.0 23.3 19.8 33.0 34.4 EWK630/06 52.5 52.3 48.8 45.1 41.4 37.5 33.5 31.2 29.0 24.4 41.8 43.7 EWK630/09 52.5 52.5 52.5 50.5 46.6 42.5 38.0 35.7 33.3 28.2 47.1 49.2 EWK680/09 57.0 57.0 57.0 55.5 51.1 47.0 42.2 39.8 37.2 30.8 51.4 53.1 EWK900/06 75.0 74.8 69.7 64.4 59.1 53.6 47.8 44.6 41.4 34.9 59.7 62.4 EWK900/09 75.0 75.0 75.0 72.2 66.5 60.7 54.2 51.1 47.5 40.3 67.3 70.3 EWK1260/06 105.0 104.7 97.6 90.2 82.8 75.0 66.9 62.5 58.0 48.8 83.6 87.4 EWK1260/09 105.0 105.0 105.0 101.1 93.2 84.9 75.9 71.5 66.6 56.4 94.2 98.4 MODUPOL EWK2100/06 163.6 155.0 145.6 135.8 125.3 114.4 102.8 96.4 90.0 76.4 125.0 129.2 EWK2100/09 180.0 175.0 165.8 155.3 143.9 131.9 118.9 111.9 104.7 89.2 143.9 148.9 EWK3100/06 233.6 220.8 207.2 193.1 178.3 162.5 145.8 136.9 127.8 108.1 177.8 183.9 EWK3100/09 260.0 258.3 244.4 228.6 211.9 193.9 174.7 164.4 153.9 130.8 211.9 219.2 EWK4500/06 345.8 326.7 306.7 285.8 263.9 240.6 215.6 202.5 189.2 160.0 263.1 271.9 EWK4500/09 380.0 372.5 351.1 328.3 303.9 278.1 250.6 236.1 220.8 187.8 304.2 314.7 EWK6100/06 479.7 453.3 425.8 396.7 366.1 333.9 299.4 281.1 262.5 222.2 365.0 377.5 EWK6100/09 515.0 508.3 479.4 448.3 415.3 380.0 342.2 322.2 301.7 256.4 415.3 429.4 EWB 1730/09 144.2 144.2 144.2 138.8 127.9 116.6 104.2 98.1 91.4 77.5 129.4 135.1 2300/09 191.7 191.7 191.7 184.5 170.1 155.1 138.6 130.5 121.5 103.0 172.0 179.5 2875/09 239.6 239.6 239.6 230.6 212.6 193.8 173.2 163.1 151.9 128.8 215.0 224.4 3600/09 300.0 300.0 300.0 288.7 266.2 242.7 216.9 204.2 190.2 161.3 269.2 281.0 EWKD EWKD144-0.6/4 11.9 11.9 11.8 10.8 10.0 9.0 8.1 7.5 6.9 5.8 9.9 10.1 EWKD225-0.6/5.5 18.6 18.6 17.5 16.3 14.9 13.5 12.1 11.3 10.6 8.9 14.6 15.1 EWKD324-0.6/5.5 25.3 23.8 22.2 20.6 18.9 17.1 15.1 14.3 13.2 11.1 18.5 19.0 EWKD324-0.9/7.5 26.8 26.8 26.7 24.7 22.8 20.6 18.6 17.4 16.3 13.8 22.4 23.2 EWKD450-2.4/5.5 32.8 30.8 28.9 26.9 24.7 22.8 20.3 19.2 17.8 15.0 24.7 25.6 EWKD450-2.7/7.5 36.4 34.4 32.2 30.0 27.5 25.0 22.5 21.1 19.6 16.7 27.2 28.1 EWKD450-3.1/11 36.7 36.7 36.1 33.3 30.8 28.1 25.1 23.6 21.9 18.6 30.3 31.4 EWKD680-2.1/5.5 45.3 42.5 39.7 36.9 33.9 30.8 27.5 25.8 24.4 20.8 33.1 34.2 EWKD680-2.5/9.2 53.1 50.0 46.9 43.3 40.0 36.7 32.8 30.8 28.6 24.4 39.7 41.1 EWKD680-3.0/15 56.7 56.7 54.4 50.6 46.7 42.5 38.1 35.6 33.3 28.3 46.1 47.5 EWKD930-2.4/11 66.9 63.1 58.9 55.0 52.8 47.8 42.8 40.3 37.5 31.7 51.7 53.1 EWKD930-2.7/15 73.6 69.2 64.7 62.8 57.8 52.5 47.2 44.4 41.4 35.0 56.9 58.6 EWKD930-3.0/22 78.1 77.2 75.3 70.3 64.7 58.9 52.8 49.4 46.1 38.9 63.3 65.0 EWKD930-3.3/30 78.1 78.1 78.1 76.9 70.8 64.4 57.8 54.2 50.6 42.8 69.7 71.9 For other Models contact Superchill 18 Technical modifications reserved Above data, especially on larger towers, do vary according to selected motor power, fan type and air intake height. The information is for preliminary sizing only. For guaranteed performance data contact Superchill.

Engineering Highlights Polypropylene Fill Up to 80ºC (or 100ºC) resistant material. Tougher material than PVC, less brittle and therefore outlasts PVC. Extruded directly from molten virgin PP (not vacuum formed) into final form ensuring optimised material thickness of foil, see foil profile below. Welded Fill Blocks The foils are welded together to form a rigid block. Compared to glued blocks, welding is a permanent and much stronger bond. Above picture shows the hitech welding machine. Best available drift eliminators Our drift eliminators comply with the Australian Standards. The above shown honeycomb drift eliminator, with three changes in air direction has a drift loss of less than 0.001% Low Maintenance Our direct-coupled fans to the motor shaft, prevent problems with belt drives in the wet air stream, such as slipping of belts combined with the squeaking noise and wearing out of belts, also improving efficiency. High efficiency, low noise fans Our high performance, low noise fans are constructed using the same technology as seen in modern aerofoil design. The wing tip at the end of the blade reduces turbulence. This increases efficiency and reduces noise. Glass reinforced PP fans are also available Special Units & Bulk Air Coolers Superchill is a specialist in designing and manufacturing bulk air coolers. Purpose-built units for any location (even for underground mining) or for total mobility can be designed and built according to the customer s needs. MODUPOL module As the name implies, our MODUPOL cooling towers are made of factory completed modules. This guarantees high quality assembly and reduces site installation time. Installation of a Module The photo shows a module being lifted into place. This cooling tower is equipped with a shallow fibreglass basin which is installed over an older existing concrete basin. Four EWK6100 MODUPOL Cooling Towers 19

Cooling tower CD to assist with your selection and layout Kühltürme von Kälteanlagen. Kälteaggregate. Kühltürme. Service CD-Version 1.0 / 2.2000 On the CD-ROM you will find a program for the calculation of the Sulzer/AXIMA cooling towers for engineers and architects. Please contact Superchill Australia to order your copy of the CD-ROM. SUPERCHILL Australia Superchill Australia Pty Ltd ACN 079 755 329 ABN 95 961 691 625 Australia Superchill Australia Pty Ltd P.O. Box 2634 256 Princes Highway Dandenong Vic 3175 Phone +61(0) 3 9793 6166 Fax +61(0) 3 9793 6050 www.superchill.com e-mail sales@ superchill.com Branch offices in Sydney, Brisbane Representatives in Perth, Adelaide, Townsville AXIMA Refrigeration GmbH, the former Sulzer Industrial Refrigeration can offer Customized refrigeration from a single source As the clear European leader in Industrial Refrigeration, AXIMA s products are at the leading edge of technology. Clients are supplied with individual solutions for all applications of industrial refrigeration and cooling. A wide advisory and service network is part of AXIMA s and Superchill s extensive range of services and products. Planning Overall planning including the supervision of smooth and efficient project management. Refrigeration plants and cooling units For processing foodstuffs, process technology, ice-skating rinks, and largescale heat pumps. Cooling towers and cooling tower plants For trade and industry as well as for cooling waste water. Service Inspection, maintenance, repair, modernization, modifications. Operation of plants, changing over to environmentally friendly refrigerants. Call for more detailed information regarding our products and the address of your nearest technical office or check out our internet web side: www.axima.eu.com www.superchill.com Worldwide AXIMA Refrigeration GmbH Former Sulzer-Escher Wyss GmbH Kemptener Strasse 11 15 D-88131 Lindau Phone +49 (0) 8382 706-1 Fax +49 (0) 8382 706-410 e-mail info-refde@axima.eu.com www.axima.eu.com/refde www.axima.eu.com Superchill is a 100% Australian-owned Company and is a member of CTI and AIRAH 2002/2/ Technical modifications reserved. Superchill Cooling Towers Pty LTd