THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

Similar documents
Installation Instructions PP-AS20 Anti-Scale System

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Surna 25-Ton Chiller Operating & Maintenance Manual

Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

OPERATION & INSTALLATION MANUAL

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Installation, Operation, and Maintenance Manual

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

INSTRUCTION MANUAL HS-229G

OWNE R S MA N UA L. Made in USA. September 2015

OPERATION AND INSTALLATION

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

OWNER'S MANUAL T0140. Contents Page #

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

- 12 VDC. HHE M - 12 VDC.

MODEL (Single Door) MODEL (2 Door pass through)

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

Quest PowerHeat HFC 100 Pro

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Owner s Manual Phoenix Aquadry TX 200

professional the the the

INSTANT-FLOW C-MICRO WATER HEATER

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

INSTALLER S & OWNER S MANUAL

Installation and Operating Instructions

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

Multiple Boilers Electro TS Series Application EB-C-STG5

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

MODENA ZUHNE

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

BlueHeat Coolant Heater Car and Light Truck Auxiliary Heater

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

INSTRUCTIONS! DO NOT DISCARD!

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Indirect Water Heaters

ERGOMAX 7 INSTALLATION

Use and Care Manual VERONA 32 OM 16 GAUGE STAINLESS STEEL SINGLE BOWL OVERMOUNT SINK ZUHNE

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

Thermostat Remote Control & Receiver

OWNER S Manual PRINTED IN CANADA 10/2009

Indirect Fired Water Heaters

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

Note To The User: This product has updated features not yet mentioned in the product manual.

MODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

INSTALLER S & OWNER S MANUAL

AHE S -12 VDC AHE S - 24 VDC

Safety & Installation Instructions

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Owners Manual. 900 Series Drinking Water Appliance

Owner s Manual for Swimming Pool Heat Pump

Horizontal Bottle Cooler Installation and Operation Manual

RIGA ZUHNE

Owner s Manual PRINTED IN CANADA 05/2009

Superstor Pro Pool Heaters

WHY TANKLESS? HOW TANKLESS WORKS LONGER LASTING CONTINUOUS HOT WATER CLEAN & FRESH WATER ENERGY SAVINGS SPACE SAVINGS. Secondary Heat Exchanger

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

INSTANT-FLOW C-MICRO WATER HEATER

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

Installation & Operation Manual Models: TSU

Installation Instructions

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

ispring Whole House Water Filter Systems USER S MANUAL

INSTALLER S & OWNER S MANUAL

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTANT HOT WATER RECIRCULATING SYSTEM

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

EZ TANKLESS EZ DELUXE OPERATION & INSTALLATION MANUAL

2 Gallon Water Boiler

PRO SERIES IMPORTANT SAFETY INFORMATION

TECHNICAL INSTRUCTIONS

Flow Factor ~

professional the the the

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Installation, Operation & Service Manual

INSTALLATION AND OPERATING MANUAL

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

2. All connections are 24 volt AC. Verify all planned connections at TT thermostat connections, before turning on power

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

INSTRUCTIONS! DO NOT DISCARD!

Non-Programmable Digital Thermostat

Quest Dry 105, 155, and 205 Dual

Transcription:

THE HEATING BOX Training Manual Model KD-HBO100 & KD-HBC100 * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System) Automatic Hot Water Management System A Combination System for Domestic Water and Space Heating KyungDong America, Inc. Toll Free 800 519-8794 www.aqenergy.com

Table Contents INTRODUCTION... 3 WHAT IS A HEATING BOX... 3 HOW DOES IT WORK... 4 BENEFITS & SAFETY... 5 SPECIFICATIONS... 6 COMPONENTS... 7 PUMP SPECIFICATIONS... 8 INSTALLATION...9 PIPING CONNECTIONS......9 WIRING INSTALLATIONS...10 APPLICATIONS...11 IN-FLOOR RADIANT FLOOR HEATING SYSTEM...11 FAN-ASSISTED HYDRO HEATING SYSTEM...12 SNOW MELTING SYSTEM...13 SPA WATER HEATING SYSTEM...13 ADJUSTMENTS & FILLING/PURGING...14 FILLING & PURGING...14 DIP SWITCH SETTINGS...15 DOMESTIC TEMP ADJUSTMENTS...16 SPACE HEATING TEMP ADJUSTMENTS...17 QUICK REFERENCE...18 LIMITED WARRANTY...20 KyungDong America, Inc. reserves the right to change specifications and/or designs without prior notice in anytime and without incurring obligations. 2

What is the Heating Box? The Heating Box is an integrated heat transfer control station that accepts hot water from a heat source and then re-directs it as required to provide domestic hot water and/or heat to hydronic applications. It works to direct hot water traffic in the most efficient and effective way to satisfy household demand. The Heating Box simplifies the design and installation of any combination domestic hot water and hydronic heating system. It facilitates the application of single source heating appliances, like tankless water heaters, with hydronics and offers the benefits of design time savings, easy installation, space savings and energy savings. The Heating Box is prefabricated with the highest quality components and guided by the computer precision control necessary to perfect domestic hot water and hydronics delivery. The Heating Box can also be used with any type of hydronic heating application including radiant in-floor heat, radiant baseboard, hydronic air handlers, snow melting systems and spa/pool heating application like towel warmers etc. A Heating Box makes perfect combination system for domestic hot water supply and space heating either in-floor or hydro heating application using one heater. 3

How Introduction Does It Work Domestic How Water Heating Only o Stand-by mode o Domestic mode is always in ready o Act like a normal water heater o 3-way valve is automatically set as Domestic hot water supply as needed Heating/Hot Water Supply o How water tap demand is ON o Priority switch activates o 3-way valve turn to domestic hot water supply mode o Pump and air handler fan stops o Hot water to tap is supplied o How water tap demand is off o Priority switch deactivates o 3-way valve goes back to heating mode o Pump and Fan is activated Heating Mode o Thermostat switch ON o 3-way valve turns to heating mode o Pump turns ON o Activates the Water Heater o All hot water supply is directed to the heating side 4

Introduction Benefits Save Time / Money o Designing Heating System o Installation / Labor Save Energy o Recycles heat from the Heat Source Save Space o Compact packaged in a tiny box Introduction Features Protect the Heat Source: (Hi-Limit Switch) Return water temperature is about 5 F higher than the water heater setting temperature: 3-way valve turns to the domestic hot water supply mode, keep circulation pump ON until supply temperature is 9 F below the setting temperature of a 3-way valve for the heating mode. Freezing Protection Heat Source and Heating Appliance When supply water temperature is less than 43 F, it automatically turns on the space heating mode for maximum 3 minutes or/and supply water temperature reaches 68 F, pump stop and it will go back to the stand by mode. 5

Specifications Introduction Minimum Flow Rate (activate priority device) Model KD-HBO100 Model KD-HBC100 Open system Close system 0.5 GPM 0.5 GPM Minimum Water Pressure 7 PSI 7 PSI Hot and Cold Water Connections 3/4" NPT 3/4" NPT Heat Source Supply & Return 3/4" NPT 3/4" NPT Space Heating Supply & Return 3/4" NPT 1 NPT Flat Heat Exchanger 80,000 Btu/Hour Each, Not Applicable (BTU/Hour) each Total 160,000 BTU/Hour Expansion Tank 1.8 Gallons 1.8 Gallons Electricity 120VAC, 60 Hz, Max. 5A, 120 VAC,60 Hz, Max 10A, Normal 2A Normal 4A Physical Size (W x H x D) 15 x 25 x 10 20 x 28 x 10 6

Components Domestic Hot water priority switch Pressure gauge for space heating Air separator and purge valve Heating Box controller Thermostatic mixing valve for space heating Flat heat exchanger Expansion Tank Space heating side circulator pump Heat source side circulator pump Thermostatic mixing valve for hot water 7

Pump Specifications Pump: Armstrong E9B o 3-way Valve: Actuator activation time 6 ~ 8 sec. o Thermostatic Mixing Valve: 86 F (30 C) ~ 140 F + (60 C+) o Expansion Tank: 1.8 Gallon o Flat Heat Exchanger: 80,000 BTU/Hour (Total 160,000 BTU) 8

Piping Connections Piping for Open-Loop System: Domestic hot water supply: ¾ Space heating connection: ¾ To water heater Outlet To City water To Space heat Return (out) Hot water supply To water heater Inlet To Space heat supply (IN) 120 VAC Piping for Closed-Loop System: Domestic hot water supply: ¾ Space heating connection: 1 To City water To Space heat Return (out) 120 VAC To water heater Outlet To water heater Inlet Hot water supply To Space heat supply (IN) 9

Wiring Installations Wiring: Power Supply: KD-HBO100, Open-Loop System 120 VAC 5A KD-HBC100, Closed-Loop System 120 VAC 10A Thermostat: Air Handler: Four wire connection 240 VAC power from air handler Radiant Heating or Spa Water Re-Heating (ON/OFF switch) Toggle switch: OFF mode Two wires connected to W and R only 10

Applications There are many applications you can apply with the Heating Box including radiant infloor, radiant baseboard, hydronic air handlers, snow melting system and more. In-Floor Radiant Space Heating System Recommended application specifications: 1. ½ PEX or other comparable products with maximum 9 space 2. 150 ~ 350 feet tube length per loop 3. 0.75 ~ 1.25 GPM in each loop in depend on loop length 4. 6 ~ 8 Maximum loop 5. 20 F temperature drop in each loop recommended 6. Recommended size of space is about 2000 sq ft maximum. 7. Recommended heat source (water heater) temperature is 180 F and radiant heating supply temperature sets between 100 ~130 F depend on applications. Radiant Heating Manifold Water heater set temperatures: 140, 160, 180 F Radiant heating supply temperatures: 120 F 11

Fan-Assisted Hydro Heating System Recommended application specifications: 1. 2.5 ~ 5 GPM flow rate 2. 30 ~ 35 F temperature drop at 140 F hot water supply to the air handler 3. Maximum 5 ton air handler for 2000 sq ft space Fan Coil Water heater set temperature: 140, 160, 180 F Hydro heating supply temperature: 140 F 12

Snow Melting System Snow Melting System s format and specifications are very similar to other heating applications. As a working media, Glycol (propylene or ethylene glycol) can be used and recommended to mix with water in this system. Recommended application specifications: 1. ½ PEX or other comparable products with maximum 9 space 2. 150 ~ 250 feet tube length per loop 3. 0.75 ~ 1.25 GPM in each loop depend on the loop length 4. 6 ~ 8 Maximum loop 5. 20 F temperature drop in each loop recommended 6. Recommended size of space is about 2000 sq ft maximum. 7. Recommended heat source (water heater) temperature is 180 F and radiant heating supply temperature sets between 100 ~130 F depend on the application. Spa Water Heating System The spa water heating system has also a similar format to the snow melting system except the glycol mixture. It is not encouraged adding any chlorine mixture to our system. The recommended set temperature for spa water should be below 105 F. 13

Water Filling and Purging System Please follow the steps below: 1. Make sure all electrical power is turned off before filling the system with water. 2. Double check all domestic hot water faucets are fully closed. 3. Conduct pressure & water leak test with/without pressurizing pipe system. Shut off the valve to the expansion tank must be closed to prevent damage to the expansion tank. When conducting test with pressurized air, test pressure must not exceed 50 PSI, before testing, check the pressure relief valve and see if it is within the test pressure range. 4. Pre-Purge; open main cold water supply valve and slowly open the purge until water leaks and shut the purge valve this clears the air out of the system. 5. Turn on power to the heating unit and built-in thermostat. 6. System Purge: This Heating Box will start circulating water. Please check with the purging valve by slowly opening until water leaks and shut the valve again to see whether there is any air left in the system. Keep repeating this step until there isn t any air left in the entire piping system. Open-Loop System Closed-Loop System 14

Dip Switch Settings * Above picture shows Space Heating s return temperature and Dip Switches. 1 2 3 Heat Source Temperature 4 OFF OFF OFF 158 (70 ) 5 ON OFF OFF 122 (50 ) 6 OFF ON OFF 140 (60 ) 7 OFF OFF ON 181 (83 ) 8 ON OFF ON OFF ON OFF ON OFF CLOSE TYPE OPEN TYPE EXTRA PUMP ON EXTRA PUMP OFF CELSIUS( ) FAHRENHEIT( ) EXTRA POWER ON EXTRA POWER OFF 15

Temp Adjustment Domestic Hot Water Supply WARNING Over 122 F (50 C) water temperature is dangerous to human body and it cause scalds and burns resulting in serious personal injury and/or death. Typical factory set temperature for domestic hot water is 120 F. 16

Space Heating Space heating water temperature is typically recommended at 120 F for a radiant space heating and above 140 F for a fan coil space heating. The Heating Box continuously monitors the temperature of space heating and returning water temperatures. The temperature of space heating side can be adjusted from 86 F (30 C) to 140 F+ (60 C+). 17

Reference Design Reference for Heat Loss Calculation This section gives a general idea to design a space heating system; it can vary system to system and case by case. Initial step in any heating system design is to determine the heating requirements (same as heat loss ) of each individual room or area. More accurate heat loss calculation is to assure the potential of maximum energy savings and to achieve maximum level of comfortness. By using the conventional heat loss calculations for radiant heating design can result to over size the system. As an example, when desired room temperature is 65 F ~ 70 F and ambient temperature is -10 F at seasonal low temperature, following resistance to heat flow values can be used for basic heat loss calculations in each construction site. Constructed Components and Sections R Factor at -10 F Seasonal Temperature Ceiling R-19 Insulation 5 R-30 Insulation 3 R-38 Insulation 2.5 Interior above Heated Ceiling 0 Walls R-11 Insulation 8 R-19 Insulation 5 Interior wall between rooms 0 Floor Un-insulated wood frame over a crawl space 18 R-11 insulation 8 R-19 Insulation 5 R-30 Insulation 3 Un-insulated slab on grade 13 R-10 insulated slab on grade 4 Interior between heated spaces 0 Window Single Glazed 80 Double Glazed 40 Door 1-1/2 Wood 35 * More detail heat loss data can be collected from the heating design software and heating design engineers. 18

From above table, factor in areas as square feet to figure out heat loss calculation (or required heat calculation and unit for the heat requirement is BTU/hr in each section. Pipe spacing in a radiant floor heating installation can directly affect the heat output. The commonly recommended pipe spacing is 8 ~ 9 with ½ PEX pipe. Also the typical pipe lengths are from 150 to 450 in each loop where pipe lengths can be calculated (in each loop, heating area times by 1.3). For an example, if heating area is 200 square feet, pipe lengths are approximately 260. Finally calculating the each loop requires flow rate divides by the total required heat output (BTU/Hour) by 500 times the design T of the system. A design T of 28 F is considered optimum for on-demand tankless water heaters. Required heat output (BTU/Hr) each loop Flow Rate = --------------------------------- 500 X T This is very rough formula to design a radiant heating system, please consult you re your heating design engineer for more accuracy of your heating system design. 19

Limited Warranty THE HEATING BOX LIMITED WARRANTY The limited warranties contained within this document are the only warranties given with your Heating Box Model KD-HBO100 and supersede any prior warranties. All other warranties, expressed or implied, including the implied warranty of merchantability or the implied warranty of fitness for a particular purpose are hereby disclaimed. Our sole obligation under this warranty, and the purchaser s sole remedy, is limited to repair or replacement of the Heating Box Model KD-HBO100, Model KD-HBC100, or one of its parts. The owner will be responsible for any other costs incurred including labor costs for servicing or replacing the part or unit, shipping, delivery and handling of the replacement part or unit, costs for permits or materials necessary for the repair, or incidental costs resulting from damage external to the unit resulting from the failure. The Heating Box Model KD-HBO100 or Model KD-HBC100 warranty coverage will be limited to the original purchaser of the unit, in its original installation location, and only if the installation is made in North America. In addition, the warranty will only apply if the unit is installed in accordance with all state, local and federal codes, and if the installation, service and maintenance are performed following the installation and Operation Manual included with the unit. The Heating Box Model KD-HBO100 or Model KD-HBC100 you have purchased is warranted to be free of defects and materials and workmanship for a period of five years from the date of purchase. Your warranty registration card must be completed and mailed to KyungDong America to establish your installation date. EXCLUSIONS FROM WARRANTY Any for the following actions shall void this limited warranty: 1. Abuse, alterations, neglect, misuse or misapplications. 2. Improper maintenance. 3. Use in conjunction with any unapproved device or devices. 4. Installation in an area with a corrosive atmosphere. 5. Incorrect water supply pressure. 6. Incorrect sizing. 7. Use with an improper Electric Power. The following are not covered by this warranty: 1. Damage resulting from fire, flood, accidents or other Acts of God. 2. Damage resulting from water freezing inside the unit or the piping. 3. Damage resulting from use with well water and water with high ph and/or high hardness levels. TO SUBMIT A CLAIM Report claims to KyungDong America, Inc. by calling 1-800-519-8794. 20