IQAN-LC5-C02 Input Devices. Catalog HY /US for North America

Similar documents
Electronic Control Systems Sensors

Hydraulic Remote Controllers Build Program Joysticks PCL401 Stackables PCL402 Foot Pedals PCL402

IQAN-LC5-C01 Input Devices. Electronic Control Systems

IQAN-LC5-C01 Input Devices. Electronic Control Systems

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Beckhoff short profile

DESCRIPTION FEATURES WARNINGS APPLICATIONS

C6097A,B Pressure Switches

PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Harrier + Smart Controller & Chemical Management System

ecostar Variable Operation Cycling Refrigerated Air Dryers ( scfm)

STT 3000 Series STT250 /150 Surge Protection Device Specifications

STAUFF STAUFF. Local solutions for individual customers worldwide. Laser Particle Monitor - LPM 1 FILTRATION TECHNOLOGY

APA501. Series AMPSS. Heatsinks for Power Modules Technical Reference Manual. Series Highlights

DWYER AROUND THE GLOBE CONTACT INFORMATION DWYER INSTRUMENTS, INC. P.O. Box 373. Michigan City, IN Return Service Requested

WH EN IGH T T C LO SED

G3 Electric Lubrication Pump

More Precision. indusensor Linear inductive displacement sensors

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Intelligent Paint Kitchen

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

More Precision. indusensor // Linear inductive displacement sensors

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

More Precision. indusensor // Linear inductive displacement sensors

G3 Electric Lubrication Pump For Series Progressive and Injector-based Systems

MTL1000 range of signal conditioners. For reliable, high quality process communications

PROFIBUS-PA Display RID 261 PROFIBUS-PA

The SharpEye 40/40I (IR3) Flame Detection

New Recognition Certification for Access Hardware INDUSTRY ARTICLE

Surface and Ambient Sensing Thermostats VE and C8 Series

XYR 6000 SmartCET Wireless Corrosion Monitoring Transmitter

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

ACCS-30. Multipoint commercial heat-tracing control system

We Manufacture Critical Service Valves For The Worlds Industries

Return loss measurement of fiber optic components

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

Functional Safety incremental encoders

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Switches & Sensors FOR VALVES & ACTUATORS

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Control Panel Basics Volume 1

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Rugged, compact, lightweight Connectors and cable assemblies. Expertise Reliability Innovation.

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

Datasheet: K-22 LO Sensor

Quadrature Speed and Direction Sensors

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

201 Series Dryers Features and Benefits...3 Dimensions...4 How to Order...5 Product Specifications...5

Touchpoint Pro Flexible Gas Control System

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

Ceiling Microwave presence/absence detector 12-24V AC/DC

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

XP-hf. Plural Component Sprayers for the Highest Demand Protective Coating Applications 1 PROVEN QUALITY. LEADING TECHNOLOGY.

MW9070B Optical Time Domain Reflectometer

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

Applications. Port Dock Marine. Border Sports Stadium Golf Course

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

Annubar Flowmeter Series

OVERVIEW SWITCHES & PROXIMITY SENSORS MICROSWITCHES LIMIT SWITCHES MANUALLY OPERATED SWITCHES PROXIMITY SENSORS. switches.crouzet.

WILDLIFE AND ASSET PROTECTION PRODUCTS

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT

The SharpEye 40/40R (IR) Flame Detection

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

HP970 and TP970 Series Standard Covers and Accessories

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

V-Basic Standard V15 Series

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

FIRELOCK NXT AUTOMATIC VALVE SYSTEMS NOT JUST VALVES SIMPLICITY.

Autocalibration Systems for In Situ Oxygen Analyzers

Refrigerants. Refrigerants with the Future in Mind

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

DESCRIPTION. 42 mm. 125 mm

Mors Smitt Railway Technology. N.S1 Signalling and vital relays

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

CPS V Cabinet Power System

Transcription:

IQAN-LC5-C02 Input Devices Catalog HY33-8405/US for North America

Application The IQAN-LC5-C02 is a large, coordinate joystick that incorporates ruggedness, functionality, light weight, and has high flexibility for mobile market applications. The unit is extremely robust, able to withstand aggressive conditions during outdoor use and in outdoor installations, including EMI, vibrations and a wide temperature range. The IQAN-LC5-C02 features a compact ergonomic design making it ideal for armrest and panel installations in mobile equipment. The IQAN-LC5-C02 is intended to replace fourth generation IQAN-LL joystick versions. An adapter cable is available to allow plug and play replacement in existing installations. Design and function The mechanical life is greatly increased over previous generations of joysticks. Full stroke force in any direction is > 100 Nm. The torsional strength has more than doubled, compared to the previous generation. The IQAN-LC5-C02 is designed for outdoor use. The housing is rated IP65 above the flange, and has integrated Deutsch connectors. The handle cable may be routed completely through the main housing. This makes field mounting of new handles or replacing a bellow very easy to accomplish. In case of water ingress (i.e. a damaged bellow), the built-in drainage from this design will protect the electronics. The base material was chosen for its non-corrosive properties. All sensors are of contactless Hall effect type with dual sensors to provide redundancy for high safety and reliability. The IQAN-LC5-C02 levers are connected to other modules through a CAN bus which makes data exchange more efficient, simplifies installation and increases noise immunity. The high number of inputs makes the base an excellent input module for external signals. The joystick has a heavy duty stem and tough base material for long life. The precise force configuration makes it easy to feel X and Y direction. The wide operating voltage range allows the IQAN-LC5-C02 to connect to both 12 VDC and 24 VDC systems. All inputs and outputs are protected against short circuit to ground and to main power supply. LED indicators show supply voltage and internal operation. The IQAN-LC5-C02 is made using selected components and conforms to strict international requirements. General (Lever base) Weight.40 kg Voltage supply 9-32 Vdc Current consumption 45mA @ 14VDC 30mA @ 28VDC CAN (ISO 11898) CAN 2.0b Protocol ICP (IQAN CAN Protocol) Mechanical (Lever base) Angle of movement ±18 Expected life (full stroke cycles) 5 million Lever force in neutral, XY 0.6 Nm Full actuated, XY direction 1.4 Nm One time loading (max.) 100 Nm Environmental (Lever base) Temperature range Operating, ambient Storage, ambient Sealing (above flange) -40 to +85 C -40 to +100 C IP65 Electrical (Lever base) Addressing idtag (address 0-7 without termination) Termination idtag (address 0-7 with termination) Connection Electrical connection Inputs Voltage inputs 2 Signal range 0-5 VDC Resolution 5 mv Digital inputs 9(10) 1 Signal high >4 VDC Signal low <= 1 VDC Deutsch DTM, 2x 6 pos., 1x 12 pos. Outputs Digital output (1) 1 Type high side switch Max load 200 ma 1) Channel is defined using IQAN software. 2 Parker Hannifin Corporation

N handle The N handle option provides a variety of control interfaces in an ergonomic, multi-function handle that comfortably fits your hand. The handle is designed for operations where a firmer control grip is desired. The ergonomic design gives good support to the arms and wrists and assures a comfortable grip from several angles. The compact design allows operators to quickly become familiar with the joystick. The handle has the capability to have a maximum of 4 buttons in the faceplate. The N handles are offered to replace previous IQAN-LL joystick versions, which used the N handle. Design and function The N handle is made to fit either the right or left hand, reducing inventory part numbers. The options are flexible and include combinations of buttons, and trigger to satisfy a variety of operator interface requirements. The N handle itself is not sealed and is recommended for in-cab use. The button switches are sealed, with gold contacts, which makes the handle satisfactory for applications in off-road equipment. The cable is routed completely through the base housing making field mounting of new handles very easy to accomplish. Connection of the handle functions is simple to accomplish by plugging the handle cable connector into the receptacle in the IQAN-LC5-C02 base. General (handle) Weight.17 kg Temperature range -40 to +85 C Sealing IP44 Buttons/Trigger switches Expected life (mechanical) 5 million Expected life (electrical) 0.2 million min. Travel 0.6 mm Actuating force 2 Nm Sealing IP65 N standard configurations 1 2 1 2 3 4 N2/N2T N4/N4T No Trigger Trigger 3 Parker Hannifin Corporation

Model code IQAN - LC5 - C02 - Code Description Code Description Code Description L lever C02 repl. IQAN-LL U1 no handle, without bellow C co-ordinate U2 no handle, with bellow, Ø40mm [Ø1.57 ] 5 fifth generation U3 no handle, with bellow, Ø10mm [Ø.39 ] N2 N handle, 2 buttons N2E N handle, 2 buttons (E2 replacement) N2T N handle, 2 buttons + trigger button N4 N handle, 4 buttons N4T* N handle, 4 buttons + trigger button * this handle option uses pins from the C2 (12 pos. Deutsch DTM) connector, which are typically reserved for external signals. Ordering part numbers (base only) IQAN-LC5-C02-U1 20076333 IQAN-LC5-C02-U2 20076334 IQAN-LC5-C02-U3 (A06) 20077644 Ordering part numbers (acc.) LC5 to -LL adapter cable 2830018 Ordering part numbers IQAN-LC5-C02-N2 20077690 IQAN-LC5-C02-N2E 20077686 IQAN-LC5-C02-N2T 20077685 IQAN-LC5-C02-N4 20077688 IQAN-LC5-C02-N4T 20077687 4 Parker Hannifin Corporation

80 (Ø 108) Alternative mounting holes 49 80 Ø 6 (8x) 105 stem detail M12 x 1.25 10 12 28 90 105 units=mm IQAN-LC5-C02 to IQAN-LL adapter cable 5 Parker Hannifin Corporation

80 (Ø 108) Alternative mounting holes 49 80 Ø 6 (8x) 240 90 105 units=mm 6 Parker Hannifin Corporation

Environmental Protection EMI ISO 13766/ISO 14982 (radiated emission) EN 55025:2003 (conducted emission) ISO 11452-4:2005 (conducted susceptibility) ISO 11452-2:2004 (radiated susceptibility) ISO 7637-3:2007 (immunity vs supply transients) ISO 7637-2:2004 (conducted transient susceptibility) ESD ISO 10605:2001, (Handling) Climate Environment IEC 60529:2001 IP65 (water) 1 IEC 60068-2-78:2001 (damp heat, steady state) IEC 60068-2-30:1985 Db (var1,damp,cyclic) IEC 60068-2-14:1984 Nb (change of temp.) IEC 60068-2-2:1993 Bb (dry heat) IEC 60068-2-1:1993 Ab (cold) Mechanical IEC 60068-2-29:1987 Eb (bump) IEC 60068-2-64:1993 Fh, Fh (random vibration) Chemical environment IEC 60068-2-52:1996 Kb (salt,mist,cyclic) 1) with sealed handle and bellow WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale Please contact your Parker representation for a detailed Offer of Sale. 7 Parker Hannifin Corporation

Sales Offices Worldwide North America Hydraulics Group Headquarters 6035 Parkland Boulevard Cleveland, OH 44124-4141 USA Tel: 216-896-3000 Fax: 216-896-4031 Parker Hannifin Canada Parker Canada Division Milton 160 Chisholm Drive Milton Ontario Canada L9T 3G9 Tel: 905-693-3000 Fax: 905-876-1958 Mexico Parker Hannifin de México Av eje uno norte num 100 Parque Industrial Toluca 2000 Toluca, Mex C.P. 50100 Tel: 52 722 2754200 Fax: 52 722 2799308 Europe Europe Hydraulics Group Parker Hannifin Corporation Parker House 55 Maylands Avenue Hemel Hempstead, Herts HP2 4SJ England Tel: 44 1442 458000 Fax: 44 1442 458085 Latin America Brazil Hydraulics Division Parker Hannifin Ind. e Com. Ltda Av. FredericoRitter, 1100 Cachoeirinha RS, 94930-000 Brazil Tel: 55 51 3470 9144 Fax: 55 51 3470 3100 Chile Parker Hannifin Chile Ltd.a Av. Americo Vespucio 2760-E, Conchali - Santiago, Chile Tel: 56 2 623 1216 Fax: 56 2 623 1421 Pan American Division 7400 NW 19th Street, Suite A Miami, FL 33126 USA Tel: 305-470-8800 Fax: 305-470-8808 Mobile Sales Mobile Sales Organization and Global Sales 850 Arthur Avenue Elk Grove Village, IL 60007 USA Tel: 847-258-6200 Fax: 847-258-6299 Industrial Sales Great Lakes Region 3700 Embassy Parkway Suite 260 Fairlawn, OH 44333 USA Tel: 330-670-2680 Fax: 330-670-2681 Southern Region 1225 Old Alpharetta Road Suite 290 Alpharetta, GA 30005 USA Tel: 770-619-9767 Fax: 770-619-9806 Chicago Region 1163 E. Ogden Avenue Suite 705, #358 Naperville, IL 60563 USA Tel: 630-964-0796 Fax: 866-473-9274 Pacific Region 8460 Kass Drive Buena Park, CA 90621 Tel: 714-228-2510 Fax: 714-228-2511 Eastern Region 100 Corporate Drive Lebanon, NJ 08833 USA Tel: 908-236-4121 Fax: 908-236-4146 Gulf Region 20002 Standing Cypress Drive Spring, TX 77379 USA Tel: 317-519-8490 Fax: 866-390-4986 Asia Pacific Asia Pacific Headquarters Parker Hannifin Hong Kong Ltd 8/F, Kin Yip Plaza 9 Cheung Yee Street HK-Cheung Sha Wan, Hong Kong Tel: 852 2428 8008 Fax: 852 2425 6896 Australia Headquarters Parker Hannifin Pty Ltd. 9 Carrington Road Castle Hill, NSW 2154, Australia Tel: 612 9634 7777 Fax: 612 9842 5111 China Headquarters Parker Hannifin Motion & Control (Shanghai) Co., Ltd 280 Yunqiao Road, Jin Qiao Export Processing Zone CN-Shanghai 201206, China Tel: 86 21 5031 2525 Fax: 86 21 5834 3714 Korea Headquarters Parker Hannifin Korea Ltd 6F Daehwa Plaza 169 Samsung-dong, Gangnam-gu KR-Seoul, 135-090, Korea Tel: 82 2 559 0400 Fax: 82 2 556 8187 South Africa Parker Hannifin Africa Pty Ltd Parker Place 10 Berne Avenue Aeroport P.O. Box 1153 ZA-Kempton Park 1620, Republic of South Africa Tel: 27 11 961 0700 Fax: 27 11 392 7213 Middle East Egypt Parker Hannifin Corporation 8B Zahraa Maadi Region 17F Cairo, Egypt Tel: 20 2 519 4018 Fax: 20 2 519 0605 2010-2011 Parker Hannifin Corporation. All rights reserved. Parker Hannifin Corporation 1651 N. Main Street Morton, IL 61550 USA phone 309 266 2200 fax 309 266 6674 www.parker.com/ecd HY33-8405/US 06/2011 Your Local Authorized Parker Distributor